Skip to main content
. 2024 Oct 23;249:10333. doi: 10.3389/ebm.2024.10333

TABLE 7.

Statistical analysis of TR-OCTA compared to GT-OCTA for 6 mm dataset from UIC.

OCTA
Dataset
Dataset (no. Of scans) BVD (Mean ± St.d) BVC (Mean ± St.d) BVT (Mean ± St.d) VPI (Mean ± St.d)
TR-OCTA Complete (258) 214.75 ± 25.5 37.30 ± 0.93 1.084 ± 0.0059 25.66 ± 2.86
GT-OCTA 199.76 ± 15.05 39.54 ± 0.87 1.089 ± 0.0069 27.14 ± 2.46
TR-OCTA Control (59) 211.57 ± 21.79 37.35 ± 0.72 1.085 ± 0.0064 28.55 ± 2.19
GT-OCTA 197.61 ± 12.83 39.40 ± 0.74 1.088 ± 0.0062 27.43 ± 2.027
TR-OCTA Mild (143) 218.19 ± 22.93 37.12 ± 1.067 1.084 ± 0.0056 25.86 ± 2.74
GT-OCTA 199.29 ± 14.16 39.60 ± 0.80 1.088 ± 0.0070 26.76 ± 2.30
TR-OCTA Moderate (69) 209.54 ± 29.57 37.64 ± 0.83 1.084 ± 0.0060 27.00 ± 2.42
GT-OCTA 204.29 ± 14.62 39.41 ± 0.93 1.089 ± 0.0072 27.81 ± 2.31
TR-OCTA Severe (123) 216.41 ± 25.25 37.14 ± 0.81 1.083 ± 0.0057 26.12 ± 2.44
GT-OCTA 201.34 ± 14.96 39.34 ± 0.84 1.089 ± 0.0072 26.72 ± 2.52