C. difficile carriers (1”x 0.9” polycarbonate, ReadyNowTM Test Carriers, Stratix Labs Corporation, Saint Paul, MN) and calibrated radiometers (ILT1270, International Light Technologies, Peabody, MA) were mounted on an aluminum stand at three positions (A = center of stand, B = left of center of stand, C = right of center of stand) and at a height of 47.5 inches from the floor, center of bulbs. The stand was positioned at 9 feet from three low-pressure mercury gas UV-C emitters that were positioned in a row, each rotating 5 degrees. The test carriers and adjacent radiometers were exposed to an increasing dose of UV-C energy from 126.55-580.77 (mJ/cm2). Log reductions (LR) were calculated by comparing the average of treatment samples (final CFU) for a given dose to the average of positive controls (initial CFU), log10 (initial CFU/final CFU). Following treatment at each target dose, carrier and control slides were removed from the cartridge and processed identically to enumerate colony-forming units (CFU). Log reductions (LR) were calculated by comparing the average of treatment samples (final CFU) for a given dose to the average of positive controls (initial CFU), log10 (initial CFU/final CFU).