Skip to main content
. 2024 Oct 25;17(21):5213. doi: 10.3390/ma17215213

Table 8.

Comparison of SCAPS and wxAMPS [201].

Voc (V) Jsc (mA/cm2) FF (%) FPE (%)
Cell Configuration SCAPS AMPS Exp. SCAPS AMPS Exp. SCAPS AMPS Exp. SCAPS AMPS Exp.
FTO/TiO2/CH3NH3PbI3/Spiro/Au 1.12 1.27 1.02 24.32 21.58 21.20 81.86 79.00 77.60 22.35 20.00 18.70
FTO/TiO2/CH3NH3PbI3/Au 0.85 0.90 0.82 20.19 22.95 18.10 82.88 81.49 78.20 1770 17.01 12.60
FTO/TiO2/CH3NH3PbI3/CuSCN/Au 1.21 1.24 1.10 20.62 23.19 19.70 79.79 77.72 75.00 20.00 22.38 18.40
FTO/TiO2/CH3NH3PbI3/CiI/Au 1.01 1.07 0.95 21.31 23.08 19.80 80.77 78.64 76.00 17.54 19.60 15.50
FTO/TiO2/CH3NH3PbI3/NiO/Au 1.01 1.13 0.93 20.23 22.00 18.90 81.46 79.38 77.00 17.28 19.89 16.20
FTO/ZnO/CH3NH3PbI3/NiO/Au 0.99 1.04 25.62 26.02 80.03 79.45 21.87 20.67
FTO/SnO2/CH3NH3PbI3/NiO/Au 0.99 1.02 25.73 25.87 75.45 74.83 19.36 18.69