Skip to main content
. 2024 Aug 3:23969873241263418. Online ahead of print. doi: 10.1177/23969873241263418

Table 4.

Comparison of the diagnostic value of DWI-FLAIR mismatch after consensus review between realFLAIR and synthFLAIR to estimate stroke onset time within 4.5 h.

Statistic realFLAIR synthFLAIR p Value
Sensitivity 60/71 (85) 59/71 (83) 0.56
Specificity 65/70 (93) 65/70 (93) >0.99
Positive predictive value 60/65 (92) 59/64 (92) 0.97
Negative predictive value 65/76 (86) 65/77 (84) 0.57

Diagnostic value was computed in the 141 MRI datasets when stroke onset-to-MRI delay was available. Data are expressed as number of MRI sets, with corresponding percentages in parentheses. Sensitivity and specificity were compared using the McNemar test. Predictive values were compared using the relative predictive value method.