Skip to main content
. 2024 Nov 18;24:419. doi: 10.1186/s12871-024-02807-z

Table 2.

Anesthesia records by traditional and observative fiberoptic scope

Traditional fiberoptic intubation
n = 51
Observative fiberoptic intubation
n = 53
P value
Anesthesia time (min) 229.7 ± 114.6 235.7 ± 139.5 0.81
Duration of intubation (min) 214.4 ± 115.4 227.2 ± 138.2 0.62
Tube size 6.0/6.5/7.0/7.5/8.0 (n) 5/19/17/9/1 5/21/22/5/0 0.42
Intubation attempt 1/2/3 (n) 43/7/1 47/4/2 0.77
Fentanyl (µg) 251.5 ± 136.2 293.4 ± 188.6 0.19
Remifentanil (µg) 2320.0 ± 1716.0 2405.6 ± 1630.5 0.79
Sore throat (n) (yes/no) 14/37 (27.4%) 16/37 (30.1%) 0.61
Hoarseness (n) 1 (7.1%) 2 (12.5%) 0.44

Values are means ± standard deviation or number, Fisher’s exact test between groups

A P value < 0.05 is considered significant