Table 3.
Determination of ERG, PRO, CAF, CAM, and MEC in pharmaceutical preparation by the suggested chemometric methods and application of standard addition technique
| Preparation | %Recovery ± %RSDa | |||
|---|---|---|---|---|
| CLS | PLS | MCR-ALS | ||
| ERG | Application | 99.22 ± 0.673 | 99.68 ± 0.491 | 99.95 ± 0.261 |
| Standard addition | 100.69 ± 0.825 | 100.86 ± 0.603 | 100.98 ± 0.381 | |
| PRO | Application | 101.31 ± 0.957 | 101.17 ± 0.735 | 101.05 ± 0.513 |
| Standard addition | 98.43 ± 0.926 | 99.31 ± 0.704 | 99.84 ± 0.482 | |
| CAF | Application | 98.11 ± 0.963 | 99.13 ± 0.741 | 99.79 ± 0.519 |
| Standard addition | 101.97 ± 0.994 | 101.63 ± 0.772 | 101.31 ± 0.550 | |
| CAM | Application | 101.21 ± 0.999 | 101.85 ± 0.777 | 101.51 ± 0.555 |
| Standard addition | 99.22 ± 0.673 | 99.68 ± 0.491 | 99.95 ± 0.261 | |
| MEC | Application | 98.76 ± 0.892 | 99.48 ± 0.670 | 99.89 ± 0.448 |
| Standard addition | 101.31 ± 0.957 | 101.17 ± 0.735 | 101.05 ± 0.513 | |
aAverage of three determinations