Skip to main content
. 2024 Nov 22;14:29016. doi: 10.1038/s41598-024-80565-1

Table 4.

Ablation: weighted average F1-score on the test set of the different model architectures.

Model architecture weighted average F1-score (%) Absolute added value
Visual encoder only 44.0 N/A
Visual encoder + sequence model 60.7 +16.7
Visual encoder + sequence model + HMM 66.3 +5.6