Table 1.
Parameters of the considered HTGS.
Parameter | Value |
---|---|
(Time constant of upstream surge tank) | 475.948(s) |
(Time constant of downstream surge tank) | 2500(s) |
(Time constant of diversion tunnel) | 3.220(s) |
(Relative head loss of diversion tunnel) | 0.026 |
(Sum of the time constants of penstock and draft tube) | 0.82(s) |
(Relative head loss of the pipe) | 0.010 |
(Time constant of tailrace tunnel) | 0.26(s) |
(Relative head loss of tailrace tunnel) | 0.015 |
(Time constant of servo-mechanism system) | 0.2(s) |
(Time constant of synchronous generator-motor) | 8.5(s) |
(Transfer coefficients of turbine) | −1.000,1.500,1.000 |
(Transfer coefficients of turbine) | 0.5,1.000,0 |
(Self-regulation factor of synchronous generator-motor) | 0.210 |