Skip to main content
. 2024 Oct 24;12(11):2443. doi: 10.3390/biomedicines12112443

Table 1.

Monocular descriptive preoperative data. CMT: central macular thickness; D: diopters; Km: mean keratometry; ERM: epiretinal membrane; FCP: foveal center point; IOP: intraocular pressure; µm: microns; mm: millimeters; mmHg: millimeters of mercury; SD: standard deviation; SE: spherical equivalent; RNFL: retinal nerve fiber layer. * Statistically significant difference.

Eyes with ERM
Mean ± SD
(Range)
Eyes Without ERM
Mean ± SD
(Range)
p-Value
Preoperative SE (D) 0.90 ± 1.56
(−3.75 to 3.50)
0.85 ± 1.36
(−1.75 to 3.50)
0.995
Preoperative Km (D) 43.67 ± 1.50
(40.84 to 45.78)
43.95 ± 1.62
(40.94 to 46.84)
0.208
Axial length (mm) 23.43 ± 0.69
(22.30 to 25.17)
23.40 ± 0.71
(22.02 to 24.81)
0.907
Anterior chamber depth (mm) 3.05 ± 0.28
(2.66 to 3.69)
3.09 ± 0.29
(2.60 to 3.64)
0.803
Implanted IOL (D) 21.77 ± 1.93
(18.50 to 27.00)
21.09 ± 1.01
(20.00 to 23.50)
0.07
Preoperative IOP (mmHg) 14.18 ± 2.92
(10.00 to 20.00)
14.27 ± 2.60
(10.00 to 21.00)
0.507
Pre-CMT (µm) 423.32 ± 80.87
(289.00 to 564.00)
282.45 ± 30.59
(185.00 to 337.00)
<0.001 *
Pre-RNFL (µm) 103.74 ± 12.46
(81.00 to 126.00)
99.16 ± 9.06
(79.00 to 111.00)
0.353
Pre-FCP (µm) 399.91 ± 101.41
(211.00 to 567.00)
236.36 ± 36.44
(146.00 to 337.00)
<0.001 *
Pre-volume (mm3) 9.85 ± 1.25
(8.42 to 12.81)
8.57 ± 0.46
(7.73 to 9.42)
<0.001 *