Skip to main content
. 2024 Nov 6;13(22):6660. doi: 10.3390/jcm13226660

Table 6.

Diagnostic accuracy measures for quantitative MRI features and age at diagnosis based on neuroblastic tumours included in the retrospective study.

Feature Sensitivity
(95% CI)
Specificity
(95% CI)
Positive LR (95% CI) Accuracy
(95% CI)
DOR and Log DOR
ADC cut-off small ROI,
1.06 × 10−3 mm2/s
0.83
(0.68, 0.98)
0.75
(0.54, 0.98)
3.33
(1.40, 7.94)
0.80
(0.64, 0.91)
DOR = 15.14
Log DOR = 2.71
ADC cut-off large ROI,
1.22 × 10−3 mm2/s
0.79
(0.63, 0.94)
0.83
(0.62, 1.00)
2.44
(1.28, 4.65)
0.80
(0.64, 0.91%)
DOR = 18.33
Log DOR = 2.91
Tumour volume cut-off, 56 cc 0.50
(0.29, 0.71)
0.63
(0.35, 0.85)
1.33
(0.63, 2.83)
0.55
(0.38, 0.71)
DOR = 1.67
Log DOR = 0.51
Age at diagnosis cut-off, 48 months 0.96
(0.79, 1.00)
0.81
(0.54, 0.96)
5.11
(1.84, 14.22)
0.90
(0.76, 0.97)
DOR = 99.66
Log DOR = 4.60

Abbreviations: DOR = diagnostic odds ratio; ADC = apparent diffusion coefficient; LR = likelihood ratio; Log = logarithmic (natural). Legend: All cut-off values were determined by Youden’s Index, and accuracy measures were calculated to 95% confidence intervals, p < 0.05.