Table 5. Viscosities μ of Aqueous Solutions Containing MEA (2), HEIA (3), and CO2 (4)a.

            μ/(mPa s)
x2 x3 x4 α0 α1 α2 298.15 K 303.15 K 313.15 K 323.15 K 333.15 K 343.15 K 353.15 K
0.1128 0 0 0 0 0 2.418 2.089 1.614 1.281 1.043 0.866
0.1102 0 0.0235 0.213 0 0 2.988 2.615 2.012 1.618 1.334 1.092
0.1091 0 0.0271 0.248 0 0 3.053 2.079 1.138
0.1076 0 0.0459 0.426 0 0 3.618 3.139 2.430 1.945 1.583 1.317
0.1062 0 0.0527 0.496 0 0 3.674 2.531 1.652
0 0.2722 0 0 0 0 21.946 17.339 11.266 7.862 5.687 4.282 3.337
0 0.1173 0 0 0 0 4.443 3.767 2.836 2.182 1.766 1.438 1.182
0 0.0419 0 0 0 0 1.667 1.483 1.175 0.960 0.798
0.1111 0.0130 0 0 0 0 2.770 2.390 1.814 1.432 1.155 0.950
0.1078 0.0127 0.0297 0.275 0.248 0.225 3.765 2.382 1.288
0.1047 0.0123 0.0576 0.55 0.495 0.450 4.694 2.955
0.1101 0.0278 0 0 0 0 3.334 2.825 2.137 1.665 1.338 1.099
0.1064 0.0266 0.0245 0.233 0.19 0.16 4.249 3.635 2.758 2.135 1.730 1.424
0.1067 0.0270 0.0304 0.285 0.228 0.19 4.389 2.748 1.379
0.1038 0.0259 0.0488 0.467 0.37 0.31 5.309 4.576 3.447 2.709
0.1036 0.0262 0.0596 0.57 0.456 0.380 5.336 3.546
a

xi is the mole fraction of component i in aqueous solution, T is temperature, and αi (i = 0, 1, 2) are measures of the CO2 loading as determined from the definitions in Table 3. Expanded uncertainties at 95% confidence are U(T) = 0.02 K, U0) = 0.03, U(x2) = 0.0002, and U(μ) = 0.05 mPa s. Expanded uncertainties at 95% confidence are U(T) = 0.02 K, U(x3) = 0.0002, and U(μ) = 0.05 mPa s. Expanded uncertainties at 95% confidence are U(T) = 0.02 K, U0) = U1) = 0.01, U2) = 0.0098, U(x2) = U(x3) = 0.0002, and U(μ) = 0.01 mPa s. All measurements were performed at a pressure of 0.1 MPa.