Skip to main content
. 2024 Nov 29;10(1):274. doi: 10.1038/s41524-024-01464-7

Table 1.

CPU time in core hours needed by the original and hybrid TOR-TILD method and the newly proposed approach for computing the ab initio free energy surface of liquid TaCrVW on a 5 × 6 (V, T) grid using LDA

Original Hybrid New

potential

fitting

t(solid EAM) 15,360 15,360 15,360
t(liquid EAM) 15,360
t(liquid lowMTP) 15,360 15,360
t(liquid highMTP) 36,000

free energy

calculation

t(Step 1) 630 630 630
t(Step 2) 25 110 110
t(Step 3) 52 2319 2319
t(Step 4) 5,526,720 990,960 23
t(Step 5) 360,000 360,000 216,000
t(total) 5,918,147 1,384,739 285,802