Skip to main content
. 2024 Nov 20;15:1482099. doi: 10.3389/fpls.2024.1482099

Table 3.

Direct measurement of Cd and Mn content for selected OsNramp5 mutants.

Construct Mn/Cd
ratio
Cd content Mn content
Relative uptake
value (%)
Mean
(ng/mg)
± SD p-value Relative
uptake
value (%)
Mean
(ng/mg)
± SD p-value
Mock 0.0 15.5 ± 1.9 ** 0.0 7.5 ± 0.8 **
WT 1.0 100.0 129.9 ± 10.0 100.0 17.0 ± 2.4
A512T 0.5 90.4 118.9 ± 19.6 48.7 12.2 ± 1.5 **
M235A 3.5 17.2 35.3 ± 3.5 ** 60.2 13.2 ± 1.2 *
M235C 5.0 10.9 28.0 ± 3.3 ** 54.8 12.7 ± 1.0 *
M232C+M235A 7.4 13.9 31.4 ± 4.9 ** 103.3 17.3 ± 0.7
M232S+M235A 3.7 22.3 41.0 ± 5.0 ** 82.8 15.4 ± 0.8
M232S+M235C 4.6 13.5 31.0 ± 7.1 ** 62.5 13.5 ± 2.1 *

The Cd/Mn content of the yeast was measured using ICP-OES. The results were analyzed based on the relative Cd/Mn uptake (%) and Mn/Cd ratio. Relative uptake values were calculated using the apparent metal content of the empty plasmid and WT as 0% and 100%, respectively. The mean and standard deviation (SD) are shown (N=3) with the statistical evaluation compared to the WT using Dunnett’s test (*p<0.05, ** p <0.01).