Abstract
Operated tendons are impacted by an inciting trauma and the subsequent treatment and will never again appear as they were prior to the insult. Post-operative tendons have unique ultrasound (US) findings that can be helpful to the surgeon in evaluating the success of repair, status of healing and confirmation that the repair remains intact. The advantage of US over physical exam or other imaging modalities is that it offers both static and dynamic assessment. The latter is of particular benefit in evaluating tendon function and gliding, which are meant to be visualized dynamically in order to provide information for the hand surgeon in defining the post-operative course. The goal of the pictorial review is to comprehensively present the US findings for postoperative complications in this field including tendon rupture, gapping, adhesion, suture granuloma and pulley disruption. Competence with ultrasound-assisted diagnosis in these domains can provide prompt feedback for providers and insight to improve patient care.
Keywords: Ultrasound, Tendon, Suture, Rupture
1. Introduction
The role of US imaging in the diagnosis of hand and upper extremity pathology continues to gain ground, and US is now routinely used for a wide range of disorders.1 Benefits of the technology in this domain are that it is noninvasive, well-suited for superficial anatomy in the hand and useful for visualizing dynamic processes.2 Static imaging modalities such as magnetic resonance imaging (MRI) can delineate areas of tendon scarring, but without dynamic assessment to fully interrogate the degree of limitation from the scar formation, it may be difficult to determine the clinical impact and whether the patient will require occupational therapy or surgical intervention. US is uniquely able to clarify some of these points as it can be employed to visualize the tendon repair during physical exam maneuvers. As compared to MRI, US is also more easily accessible both with regards to cost and speed of the assessment, since US can be performed in a point-of-care fashion. US is better tolerated by young children and adults with claustrophobia. While physical exam can be beneficial for gross assessment, it fails to reliably differentiate between scar adhesion and tendon disruption, since there is no ability to visualize the internal structures. For these reasons, ultrasonography is a powerful tool for investigating tendon function in the hand and wrist.3,4 In the case of operated tendons, US is a reliable first-line modality for exploring pathology and complications such as adhesions or rupture.5,6 Particularly in such cases, clinical correlation and background are paramount to establishing the diagnosis. In some cases of operated tendons where ultrasound imaging leads to equivocal conclusions, MRI can provide additional information due to the enhanced resolution when a paramagnetic contrast agent is used.5
Lacerations of the distal upper extremity tendons result in significant hand dysfunction and require prompt and diligent repair. The lacerated tendons within the hand and forearm can lose all mechanical advantage when a specific percentage of the tendon is disrupted. Such injuries necessitate suture repair with simultaneous attention to both the repair strength to reduce gapping with motion as well as the ability of the tendons to freely glide within their sheath.7 With the above in mind, it is possible for the trained ultrasonographer to monitor clinical evidence of healing as well as any aberrancies. The purpose of this pictorial review is to provide radiographic insight into this process along with clinical correlation from the perspective of hand surgery. The operated field leaves behind suture and a gradual process of scarring that distorts normal anatomy. The ability to differentiate pathologic from physiologic healing is fundamental to guiding further surgical or therapeutic care after trauma to the upper extremity. The cases highlight the importance of the clinical context and provide the surgical background to better understand the underlying issues. In particular, suture material can be visualized by the ultrasonographer as an echogenic curvilinear structure, and its interplay with the surrounding tendon ends and soft tissue is helpful in establishing a diagnosis. Early intervention may correct the dysfunction and could help to improve outcomes.
2. Physiologic tendon healing
Traumatized and repaired tendons are permanently altered structurally from their native anatomy. Swelling, scarification and dissolution of tendon fibrillar alignment are common within the first few months postoperatively, and these changes are often irreversible.5,8,9 There is a thickening around the suture material that is sometimes called a “tendon callus” and is a reliable sign of an intact repair where the tendon edges are fused centrally with suture material.5 Certain “normal” findings that are apparent over the first 3–6 months postoperatively include hypoechoic areas around the suture material and a heterogeneous morphology of the tendon structure.5 This is highlighted in the case in Fig. 1. Excessive thinning or loss of the callus can be a sign of impending rupture as the ends pull away from one another, allowing the suture material to slip through the frayed ends. Due to the superficial position of the tendons in the hand and wrist, US is a reliable method for correctly differentiating flexor tendon rupture from adhesive scarring, with a reported accuracy between 53 and 97 % in the literature.10, 11, 12
Fig. 1.
Sonographic Image of Physiologic Postoperative Tendon Healing
Figure I. Case of physiologic healing following primary suture repair of the third digit common extensor tendon at the level of the metacarpal head. Longitudinal sonographic image showing that the proximal (thin arrows) and distal (thick arrows) portions of the tendon are united without a gap. Echogenic material (curved arrow) within the tendon is consistent with suture material. This is compatible with successful tendon repair.
3. Complete rupture
Cases of complete failure or rupture of the surgical repair can appear with many of the distinguishing features of complete tendon laceration including tendon discontinuity, retraction of the tendon ends, and fluid within the tendon sheath.13 The primary difference between those entities is the presence of suture material left behind in one of the tendon ends as seen in Fig. 2. This is what is visualized when there is incomplete suture purchase in one of the tendon ends, such that when force is applied across the repair, the suture threads slip through the longitudinal fibers and out of the end of the tendon. Details on surgical repair and techniques are reviewed in the literature but are beyond the scope of the current study.14, 15, 16, 17
Fig. 2.
Sonographic Images of Complete Tendon Rupture
Figure II. Case of tendon rupture following repair of a fifth digit flexor digitorum profundus (FDP) tendon that had been repaired primarily 2 weeks prior. The patient had removed her splint and felt a popping sensation in the digit. Transverse (A) and longitudinal (B) US images of the surgical area confirm the diagnosis. On the right, the proximal stump (thin arrows) and distal stump (thick arrows) are separated by a gap (G) measuring 9 mm long. Echogenic material in the distal stump (curved arrow on the left-hand image) is consistent with suture material. This is compatible with complete tendon rupture and retraction after failed repair. The imaging findings were later confirmed intraoperatively during a re-repair.
4. Suture gapping
There exists an in between state between the first two entities of normal healing versus complete rupture where the repair begins to pull apart but remains loosely connected through the spanning suture threads. When this gap between the cut ends exceeds more than a few millimeters, there can be a loss of mechanical advantage and absence of movement across the target joint. Usually this signifies impending complete rupture, and when this is picked up on US imaging, there may be a short window of time until the sutures pull through the tendon ends. Treatment is often prophylactic in both suture choice and surgical repair technique from the outset.18 In cases of impending rupture as in the case in Fig. 3, operative re-repair was determined to be essential to correct the issue and restore functional integrity.
Fig. 3.
Sonographic Images of Suture Gapping
Figure III. Case of a woman who lacerated her fourth digit FDP tendon after breaking a glass cup. She had the tendon repaired primarily in the operating room. Approximately a month and a half afterwards, she demonstrated an inability to flex her distal phalanx. Longitudinal (A) and transverse (B) US images show a gap at the repair site. The sharp edges of the proximal (thin arrow) and distal (thick arrow) transected tendon are displaced by 1.1 cm. On the left, there is a hypoechoic gap (G) filled with fluid between the tendon margins. The echogenic sutures still attached to the tendons are clearly visible crossing the gap and in the tendon margin (curved arrows in both images). An echogenic linear structure deep to the tendon is the middle phalangeal cortex (arrow heads).
5. Scar adhesion
One of the critical questions that arises in the postoperative period following flexor tendon repair begins with the presentation of an inability to flex or extend across a target joint. Often, there is little accompanying evidence, and patients may not be able to identify a change in therapy or compliance with a post-operative protocol. The clinician is then tasked with determining whether there is a rupture of the repair or an intact repair that is scarred in place to the surrounding tissue. US is sensitive in this regard and can ensure that a repair is in continuity, as is the case in Fig. 4.10 Dense scar tissue can present as a peritendinous hypoechoic mass of soft tissue abutting or encasing the tendon, and there is a lack of any gliding.10 Additionally, synovial sheath thickening or fluid can be a sign of inflammation and synovitis that can persist for the first few postoperative months.5 Differentiating normal from abnormal requires clinical correlation, but the clues above can clarify an ambiguous process.
Fig. 4.
Sonographic Image of Postoperative Scar Adhesion
Figure IV. Case of a young woman who accidently cut the volar aspect of her thumb with a knife and severed the flexor pollicis longus (FPL) tendon. She underwent primary suture repair of the tendon. Several weeks after the repair, she was unable to flex the tip of her thumb and was sent for evaluation. Longitudinal US image reveals restriction in gliding of the FPL tendon at the level of the proximal phalangeal base after repair. Sutures (curved arrows) are visualized in the mid substance of the tendon (straight arrows). A hypoechoic mass (arrow heads) is slightly compressing the superficial surface of the tendon and is consistent with restricting adhesions.
6. Suture granuloma
Suture granulomas represent prolonged inflammatory reactions to suture material that is treated as a foreign body. In severe cases, the suture material is encased in an inflammatory shell and can occasionally cause extrusion of the material through the skin that is broken down by the persistent inflammation. This can be painful and functionally limiting. Complications result from certain types of nonabsorbable suture material, since absorbable materials are typically hydrolyzed or enzymatically dissolved before they can generate granulomas. In one study on flexor tendon repairs, the rate of suture granuloma formation was 3.5 % with braided polyethylene and 0.0 % with braided polyester.19 At the same time in a biomechanical study, braided polyethylene produced a stronger and stiffer repair than did braided polyester, monofilament nylon or monofilament polypropylene.20 The treatment when this occurred following Achilles tendon repairs involved the excision of the foreign body reaction tissue and repair with absorbable material.21 Additionally, prophylactically burying the knot between the tendon ends may help to prevent the reaction such as can be formed with an external knot as seen in Fig. 5.
Fig. 5.
Sonographic Images of a Repair-site Suture Granuloma
Figure V. Case of a patient who lacerated a common extensor tendon from a piece of broken glass. She underwent uneventful primary suture repair. A few months later, she noticed a palpable, occasionally tender dorsal hand mass overlying the metacarpophalangeal (MCP) joint. She was referred for sonographic analysis. Longitudinal (A) and transverse (B) US images demonstrate a curved echogenic structure with a braided texture (curved arrows). This is consistent with a suture knot from the repaired tendon ends (between the thin arrows) at the MCP joint level. The superficial portion of the suture is curving within the hypoechoic mass (between the arrow heads) suggestive of a suture granuloma.
7. Pulley disruption
One of the less-commonly suspected etiologies for the loss of mechanical function in a patient who is recovering from tendon repair is the loss of the pulley system. There are both annular ligaments and cruciate pulleys that work in concert to optimize the mechanics of flexion while allowing gliding of the tendons closely apposed to the phalanges. Loss of both the A2 and A4 pulleys can allow for bowstringing where the contracted tendon lifts from the surface of the bone and tents against the skin, thereby preventing full flexion across each of the digital joints. It is possible to visualize the A2 and A4 pulleys using US, and one can similarly diagnose ruptures of these pulleys with the appropriate clinical context in cases where the distance from the tendon to bone exceeds a certain threshold.22,23 The case in Fig. 6 highlights the lifting of the tendon from the surface of the phalanx. It is possible and sometimes advised to prophylactically vent either or both the A2 and the A4 pulley in a bulky tendon repair to ensure seamless gliding of the tendon through the sheath.24 Even where venting is performed, this is done conservatively to prevent compromise of flexion dynamics. In one recent study, the authors show that the loss of a contiguous length of 2.25 cm or greater of the pulley system, such as would occur with loss of the A1 and A2 pulleys, contributes to significant loss of tendon excursion.25
Fig. 6.
Sonographic Image of Pulley Disruption
Figure VI. Case of a patient who sustained a laceration to the fifth digit FDP tendon and underwent primary suture repair in the operating room. Several weeks following the repair, she noticed only minimal flexion across the distal interphalangeal joint, and there was no appreciable change with therapy. Rupture of the repair was suspected, and she was sent for US. Longitudinal US image demonstrates that the repaired FDP tendon (between the long arrows) was lifted from the volar surface of the phalanx (arrow heads) consistent with tendon bowstringing. This is concerning for tear of the pulleys. Echogenic material in the distal aspect of the tendon (curved arrow) is consistent with suture material.
8. Conclusions
US is a valuable tool for the monitoring and diagnosis of complications in patients who have undergone repair of lacerated hand and forearm tendons. The trained sonographer can distinguish across a wide differential of issues including tendon rupture, suture gapping, adhesions, suture granuloma or pulley disruption. Key takeaway points in these regards to monitor for appropriate healing are as follows:
-
1.
Ensure that a repair is intact by visualizing the caliber of the tendon at the repair site, which should appear thicker than uninvolved tendon due to loss of the tight fibrillar array.
-
2.
Echogenic suture material can localize the repair site within the substance of the tendon ends and should not bridge across a fluid-filled gap.
-
3.
A hypoechoic mass abutting or encasing the tendon near the repair can be a marker of scar adhesion limiting the tendon gliding.
-
4.
An extrinsically-positioned suture knot with a surrounding hypoechoic mass corresponding to inflammatory tissue signifies a suture granuloma.
-
5.
Lifting of the tendon from the surface of the phalanges during flexion can indicate loss of the pulley array within the digit and subsequent bowstringing.
As a non-invasive modality, US provides prompt feedback in these situations to guide management decisions and improve outcomes.
Declaration of competing interest
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Footnotes
The plan for the retrospective review was submitted to and granted exemption from further IRB review, along with waiver of consent.
References
- 1.Bodor M., Fullerton B. Ultrasonography of the hand, wrist, and elbow. Phys Med Rehabil Clin. 2010;21(3):509–531. doi: 10.1016/j.pmr.2010.04.003. [DOI] [PubMed] [Google Scholar]
- 2.Lee J.C., Healy J.C. Normal sonographic anatomy of the wrist and hand. Radiographics. 2005;25(6):1577–1590. doi: 10.1148/rg.256055028. [DOI] [PubMed] [Google Scholar]
- 3.Rosskopf A.B., Martinoli C., Sconfienza L.M., et al. Sonography of tendon pathology in the hand and wrist. J Ultrason. 2021;21(87):e306–e317. doi: 10.15557/JoU.2021.0052. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ravnic D.J., Galiano R.D., Bodavula V., Friedman D.W., Flores R.L. Diagnosis and localisation of flexor tendon injuries by surgeon-performed ultrasound: a cadaveric study. J Plast Reconstr Aesthetic Surg. 2011;64(2):234–239. doi: 10.1016/j.bjps.2010.04.035. [DOI] [PubMed] [Google Scholar]
- 5.Cohen M. US imaging in operated tendons. J Ultrasound. 2011;15(1):69–75. doi: 10.1016/j.jus.2011.11.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Al-Hourani K., Gamble D., Armstrong P., O'Neill G., Kirkpatrick J. The predictive value of ultrasound scanning in certain hand and wrist conditions. J Hand Surg Asian Pac. 2018;23(1):76–81. doi: 10.1142/S2424835518500108. [DOI] [PubMed] [Google Scholar]
- 7.Ishak A., Rajangam A., Khajuria A. The evidence-base for the management of flexor tendon injuries of the hand: review. Ann Med Surg (Lond). 2019;48:1–6. doi: 10.1016/j.amsu.2019.10.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Rupp S., Tempelhof S., Fritsch E. Ultrasound of the Achilles tendon after surgical repair: morphology and function. Br J Radiol. 1995;68(809):454–458. doi: 10.1259/0007-1285-68-809-454. [DOI] [PubMed] [Google Scholar]
- 9.Andarawis-Puri N., Flatow E.L., Soslowsky L.J. Tendon basic science: development, repair, regeneration, and healing. J Orthop Res. 2015;33(6):780–784. doi: 10.1002/jor.22869. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Budovec J.J., Sudakoff G.S., Dzwierzynski W.W., Matloub H.S., Sanger J.R. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair. J Hand Surg Am. 2006;31(4):524–529. doi: 10.1016/j.jhsa.2006.01.003. [DOI] [PubMed] [Google Scholar]
- 11.Bezirgan U., Acar E., Erdoğan Y., Armangil M. The diagnostic value of ultrasonography and magnetic resonance imaging in missed hand tendon injuries. Ulus Trauma Acil Cerrahi Derg. 2023;29(4):530–537. doi: 10.14744/tjtes.2023.78622. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Wu T.S., Roque P.J., Green J., et al. Bedside ultrasound evaluation of tendon injuries. Am J Emerg Med. 2012;30(8):1617–1621. doi: 10.1016/j.ajem.2011.11.004. [DOI] [PubMed] [Google Scholar]
- 13.Lee S.M., Ha D.H., Han S.H. Differential sonographic features of the extensor pollicis longus tendon rupture and other finger tendons rupture in the setting of hand and wrist trauma. PLoS One. 2018;13(10) doi: 10.1371/journal.pone.0205111. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Pan Z.J., Pan L., Xu Y.F., Ma T., Yao L.H. Outcomes of 200 digital flexor tendon repairs using updated protocols and 30 repairs using an old protocol: experience over 7 years. J Hand Surg Eur. 2020;45(1):56–63. doi: 10.1177/1753193419883579. [DOI] [PubMed] [Google Scholar]
- 15.Tang J.B., Zhang Y., Cao Y., Xie R.G. Core suture purchase affects strength of tendon repairs. J Hand Surg Am. 2005;30(6):1262–1266. doi: 10.1016/j.jhsa.2005.05.011. [DOI] [PubMed] [Google Scholar]
- 16.Wu Y.F., Tang J.B. Recent developments in flexor tendon repair techniques and factors influencing strength of the tendon repair. J Hand Surg Eur. 2014;39(1):6–19. doi: 10.1177/1753193413492914. [DOI] [PubMed] [Google Scholar]
- 17.Stein T., Ali A., Hamman J., Mass D.P. A randomized biomechanical study of zone II human flexor tendon repairs analyzed in an in vitro model. J Hand Surg Am. 1998;23(6):1046–1051. doi: 10.1016/S0363-5023(98)80014-2. [DOI] [PubMed] [Google Scholar]
- 18.Savage R. The search for the ideal tendon repair in zone 2: strand number, anchor points and suture thickness. J Hand Surg Eur. 2014;39(1):20–29. doi: 10.1177/1753193413508699. [DOI] [PubMed] [Google Scholar]
- 19.Arner M., Unge L., Franko M.A., Svingen J. Inflammatory reaction to suture materials after flexor tendon repair. A retrospective study of 594 patients. Case Reports Plast Surg Hand Surg. 2023;10(1) doi: 10.1080/23320885.2023.2222807. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Lawrence T.M., Davis T.R.C. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair. J Hand Surg Am. 2005;30(4):836–841. doi: 10.1016/j.jhsa.2005.03.011. [DOI] [PubMed] [Google Scholar]
- 21.Kim J., Kang H.J., Kim B.S., et al. Clinical features and treatment of intra-tendinous suture reaction following Achilles tendon repair using nonabsorbable suture material: a retrospective case series study. Int J Environ Res Publ Health. 2022;19(19) doi: 10.3390/ijerph191912897. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Schöffl I., Hugel A., Schöffl V., Rascher W., Jüngert J. Diagnosis of complex pulley ruptures using ultrasound in cadaver models. Ultrasound Med Biol. 2017;43(3):662–669. doi: 10.1016/j.ultrasmedbio.2016.10.005. [DOI] [PubMed] [Google Scholar]
- 23.Iruretagoiena-Urbieta X., De la Fuente-Ortiz de Zarate J., Rodríguez-López E.S., et al. Ultrasonographic diagnosis of A2 or A4 flexor tendon pulley injury: a systematic review. Wilderness Environ Med. 2020;31(4):498–505. doi: 10.1016/j.wem.2020.07.007. [DOI] [PubMed] [Google Scholar]
- 24.Zafonte B., Rendulic D., Szabo R.M. Flexor pulley system: anatomy, injury, and management. J Hand Surg Am. 2014;39(12):2525–2532. doi: 10.1016/j.jhsa.2014.06.005. [DOI] [PubMed] [Google Scholar]
- 25.Cox H.G., Hill J.B., Colon A.F., Abbasi P., Giladi A.M., Katz R.D. The impact of dividing the flexor tendon pulleys on tendon excursion and work of flexion in a cadaveric model. J Hand Surg Am. 2021;46(12):1064–1070. doi: 10.1016/j.jhsa.2021.05.013. [DOI] [PubMed] [Google Scholar]