Skip to main content
. 2024 Nov 27;121(12):e20240430. [Article in Portuguese] doi: 10.36660/abc.20240430

Table 1. – Baseline characteristics of the included studies.

Authors Year Study design N Condition Imaging method Segmentation software 3D Printer Model Printing materials Costs Study purpose
Bhatla et al.9 2016 Case series 6 VSD, DORV MRI or CT scans Materialise Mimics - - - Perioperative planning
Garekar et al.10 2016 Case series 5 DORV MRI or CT scans - 3D Systems Projet 660 pro full color PLA filament - Perioperative planning and Education
Han et al.11 2019 Control study 12 (6/6) interrupted aortic arch, VSD, DORV, hypoplasia of aortic arch, aortic atresia, aortic coarctation CT scans - Formlabs Photopolymer resin - Performance
He et al.12 2019 Case series 5 ASD With an Inferior Sinus Venosus Defect CT scans Materialise Mimics ZRapid SLA450 RAPID Photosensitive Resin - Perioperative planning
Hoashi et al.13 2018 Case series 20 DORV, TGA, interrupted aortic arch, TOF CT scans - SOUP2 600GS and SCS-8100 Photopolymer resin 2000–3000 USD/model Perioperative planning
Kappanayil et al.14 2017 Case series 5 complex DORV, two patients with criss‐cross atrioventricular connections, CCTGA MRI or CT scans Materialise Mimics - Photopolymer resin or PLA - Perioperative planning
Matsubara et al.15 2019 Control study 11 (4/7) PDA CT scans Ziostation2 and OsiriX UP Plus2 3D printer ABS filament 90 USD/model Planning and Performance
Nam et al.16 2021 Control study 6 TOF; complex pulmonary stenosis CT scans Materialise Mimics Stratasys Object500 Connex Photosensitive Resin 100 USD/model Performance
Olivieri et al.17 2016 Case series 10 Multiple CHD MRI or CT scans Materialise Mimics Stratasys Object500 Connex Photosensitive Resin 200 USD/model Education and knowledge
Ryan et al.18 2018 Control study 146 (33/113) Pulmonary atresia, TOF, DORV, truncus arteriosus, vascular rings, single ventricle MRI or CT scans Geomagic and 3-matic zPrinter 650 Photosensitive Resin - Perioperatorive planning, performance and acceptance
Shi et al.19 2021 Control study 23 (10/13) Balanced ventricular and Imbalanced ventricular group CT scans Materialise Mimics BQ Witbox PLA filament - Planning and performance
Sun et al.20 2017 Case series 5 Kommerell’s diverticulum CT scans Medraw Pangu V4.1 PLA filament - Perioperative planning
Tiwari et al.21 2021 Crossover study 10 DORV with VSD and other CHDs of ventriculoarterial discordance CT scans Materialise Mimics - PLA or PVA filament 350 USD/model Perioperative planning
Valverde et al.22 2017 Crossover study 40 Multiple CHD, predominatly DORV with VSD MRI or CT scans ITK-SNAP Software BQ Witbox TPU filament 300-500 USD/model Perioperative planning
Wang et al.23 2016 Case series 6 ASD with rim deficiency CT scans Materialise Mimics ZRapid SLA450 RAPID Photosensitive Resin - Perioperative planning
Xu et al.24 2019 Case series 15 Multiple CHD CT scans Materialise Mimics ISLA650 Photosensitive Resin - Perioperative planning
Xu et al.25 2019 Case series 17 Abnormal pulmonary venous drainage CT scans Materialise Mimics ISLA650 Photosensitive Resin - Perioperative planning
Yan et al.26 2018 Case series 35 ASD with rim deficiency CT scans - Objet350 Connex3 Photosensitive Resin 1200–1300 USD/model Training and Performance
Yan et al.27 2018 Case series 7 ASD with no right pulmonary vein rim CT scans Materialise Mimics Objet350 Connex3 Photosensitive Resin - Perioperative planning
Zhao et al.28 2018 Control study 25 (8/17) DORV CT scans Materialise Mimics ZPrinter 650 Photosensitive Resin - Planning and Performance

ASD: atrial septal defect; TOF: Tetralogy of Fallot; DORV: double outlet right ventricle; TGA: transposition of great arteries; VSD: ventricular septal defect; CCTGA: congenitally corrected transposition of great arteries; CT: computed tomography; MRI: magnetic resonance imaging; PLA: Polylactic Acid; ABS: Acrylonitrile Butadiene Styrene; PVA: Polyvinyl Alcohol; TPU: Thermoplastic Polyurethane; CHD: congenital heart disease; PDA: Patent ductus arteriosus.