Skip to main content
. 2024 Oct 2;20(50):2406619. doi: 10.1002/smll.202406619

Table 2.

Test conditions for the low‐pressure experiments.

Absolute pressure (kPa) ≈99 54.3 36.3 30.3 24.3
Orifice diameter (mm) N/A 0.838 0.711 0.635 0.584
Gas mean free path (nm) 65.7 129.7 161.0 212.4 252.8
Mass flow rate (ls min−1) a) 10.9 5.9 3.9 3.3 2.6
Face velocity (cm s−1) 10.5 10.5 10.5 10.5 10.5
a)

Standard liters per minute referenced to 21.1 °C and 101.3kP absolute pressure.