Skip to main content
. 2024 May 17;54:110523. doi: 10.1016/j.dib.2024.110523

Table 3.

The comparison between the measured and compensated phase when a chirp signal with a frequency range of 10,000 to 40,000 Hz and duration of 1 s was excited into the room - high pass filter is activated in this example.

Frequency interval [Hz] Compensated phase [deg.] Measured phase [deg.]
20,000 57.36 57.36
21,000 77.90 83.75
22,000 135.31 146.83
23,000 102.37 119.37
24,000 48.42 70.72
25,000 80.56 107.97
26,000 82.95 115.29
27,000 153.29 −169.64
28,000 5–112.60 −70.97
29,000 −142.17 −96.17
30,000 53.88 104.05
31,000 −85.16 −30.98
32,000 −90.60 −32.62
33,000 1.57 63.17
34,000 −56.32 8.72
35,000 133.02 −158.69
36,000 −3.314 68.04
37,000 153.75 −132.01
38,000 130.37 −152.70
39,000 −99.61 −20.18
40,000 164.93 −113.30