TABLE I.

Major Clinical Trials, by Left Ventricular Ejection Fraction Subpopulation, Comparing BVP, His Bundle Pacing, and Left Bundle Branch Area Pacing for CRT and Their Primary End Points

Left ventricular ejection fraction ≤35% Left ventricular ejection fraction 36%-49% Left ventricular ejection fraction ≥50%
CSP-SYNC [NCT05155865]
(CSP vs BIVP) (N = 60)
End points: left ventricular ejection fraction, left ventricular volume, New York Heart Association classification, 6-minute walk test, quality of life
His-PACE [NCT04672408]
(His bundle pacing vs right ventricular pacing) (N = 50)
End point: left ventricular ejection fraction
HIS-alt_2 [NCT04409119]
(CSP vs BIVP) (N = 125)
End points: left ventricular end-systolic volume, QRS duration
HIS-PrEF [NCT04529577]
(His bundle pacing vs right ventricular pacing) (N = 40)
End point: left ventricular ejection fraction
HIS-CRT [NCT05265520]
(His bundle pacing vs BIVP) (N = 120)
End point: left ventricular ejection fraction
LEAP [NCT04595487]
(Left ventricular septal pacing vs right ventricular pacing) (N = 470)
End points: death, HF hospitalizations, left ventricular ejection fraction decrease by 10%
His-SYNC [NCT02700425]
(His bundle pacing vs BIVP) (N = 41)
End point: QRS duration
LEFT HF [NCT05015660]
(Left bundle branch area pacing vs right ventricular pacing) (N = 1,280)
End points: cardiovascular death, HF events
LeCaRT [NCT05365568]
(Left bundle branch area pacing vs BIVP) (N = 170)
End points: composite death, HF hospitalizations, worsening HF, implant failure, cardiac implantable electrical device re-intervention
OptimPacing [NCT04624763]
(Left bundle branch area pacing vs right ventricular pacing) (N = 683)
End points: death, HF hospitalizations, pacemaker-induced cardiomyopathy
LIT-HF [NCT05572957]
(CSP vs guideline-directed medical therapy) (N = 50)
End point: left ventricular ejection fraction
PROTECT-HF [NCT05815745]
(His bundle pacing vs right ventricular pacing) (N = 2,600)
End points: cardiovascular death, HF events
Left-Bundle CRT [NCT05434962]
(Left bundle branch area pacing vs BIVP) (N = 176)
End point: CRT response
REINVENT-CRT [NCT05652218]
(Left bundle branch area pacing vs BIVP) (N = 20)
End point: myocardial perfusion imaging
PhysioSync-HF [NCT05572736]
(CSP vs BIVP) (N = 304)
End points: death, HF hospitalizations, left ventricular ejection fraction
CONSYST-CRT [NCT05187611]
(CSP vs BIVP) (N = 130)
End points: composite death, cardiac transplant, HF hospitalizations, and left ventricular ejection fraction
LBB Pacing Versus Conventional Pacing in Atrioventricular Block [NCT05722379]
(Left bundle branch area pacing vs right ventricular pacing) (N = 27)
End point: global work efficiency
HIPPOS [NCT05491655]
(His bundle pacing vs backup right ventricular pacing) (N = 34)
End point: left ventricular ejection fraction
RHYSPAVB [NCT05214365]
(His bundle pacing vs right ventricular pacing) (N = 200)
End point: pacemaker-induced cardiomyopathy
LBBAP-AFHF [NCT05549544]
(Left bundle branch area pacing vs BIVP) (N = 60)
End point: left ventricular ejection fraction
Vanguard [NCT05015660]
(Left bundle branch area pacing vs right ventricular pacing) (N = 100)
End points: death, HF events, left ventricular end-systolic volume, changes in lead parameters, quality of life; and safety
LBB Pacing in Patients with Cardiac Dysfunction and AV Block [NCT05553626]
(Left bundle branch area pacing vs BIVP) (N = 160)
End point: left ventricular ejection fraction
Left vs Left [NCT05650658]
(CSP vs BIVP) (N = 2,136)
End points: death, HF hospitalizations, quality of life

BIVP, biventricular pacing; CRT, cardiac resynchronization therapy; CSP, conduction system pacing; HF, heart failure.