Testing results of the novel reinforcement method of grouting sleeve connection.

No. Ultimate Load
(kN)
Tensile Strength
(MPa)
fmst0/fstk Failure Type
RM1-1 122.13 607.43 1.12 P
RM1-2 122.56 609.57 1.13 P
RM1-3 121.56 604.60 1.12 P
RM2-1 121.12 602.41 1.12 P
RM2-2 123.11 612.30 1.13 P
RM2-3 122.32 608.38 1.13 P
RM3-1 127.34 633.22 1.17 P
RM3-2 92.86 - 0.86 M
RM3-3 84.13 - 0.77 N
RM4-1 90.32 586.72 1.09 P
RM4-2 98.18 637.78 1.18 P
RM4-3 95.69 621.61 1.15 P
RM5-1 165.52 650.45 1.20 P
RM5-2 161.48 634.57 1.18 P
RM5-3 160.06 628.99 1.16 P
RM6-1 123.45 614.00 1.14 P
RM6-2 122.76 610.56 1.13 P
RM6-3 124.16 617.53 1.14 P
RM7-1 123.01 611.81 1.13 P
RM7-2 122.76 610.56 1.13 P
RM7-3 121.98 606.68 1.12 P
RM8-1 123.11 612.30 1.13 P
RM8-2 122.67 610.12 1.13 P
RM8-3 122.78 610.66 1.13 P
RM9-1 130.58 649.33 1.20 P
RM9-2 130.28 647.84 1.20 P
RM9-3 122.64 609.85 1.13 P
RM10-1 95.93 623.16 1.15 P
RM10-2 95.68 621.54 1.15 P
RM10-3 91.11 591.85 1.10 P
RM11-1 161.93 636.34 1.18 P
RM11-2 162.60 638.98 1.18 P
RM11-3 162.03 636.74 1.18 P
RM12-1 124.12 617.33 1.14 P
RM12-2 123.11 612.30 1.13 P
RM12-3 122.71 610.32 1.13 P
RM13-1 127.66 634.81 1.18 P
RM13-2 130.18 647.34 1.20 P
RM13-3 131.02 651.52 1.21 P
RM14-1 161.98 636.54 1.18 P
RM14-2 161.12 633.16 1.17 P
RM14-3 164.96 648.25 1.20 P
RM15-1 90.13 - 0.83 M
RM15-2 130.07 646.79 1.20 P
RM15-3 130.75 650.17 1.20 P