Skip to main content
. 2024 Dec 2;24(23):7704. doi: 10.3390/s24237704

Table 3.

Microchannel slab thickness optimization.

Thickness (mm) Flow Rate Consistent? Observation
0.96 Yes Fluidic flow occurred, but the slab ruptured and caused a leak in the microchannel during the fifth cycle.
2.11 Yes Fluidic flow occurred. No rupture observed. Structural integrity preserved even after 10 cycles.
2.94 Yes Fluidic flow occurred. No rupture observed. Structural integrity preserved even after 10 cycles.
4.07 -NA- No fluidic flow. Slab too thick to deflect under solenoid push.