Filtering results and indicators of different filtering algorithms for incomplete penetration.

Type Filtering Result MSE PSNR (dB) SSIM Filtering Time (s)
Gaussian filtering graphic file with name sensors-24-07649-i001.jpg 0.39 52.18 0.9956 0.1009
Bilateral filtering graphic file with name sensors-24-07649-i002.jpg 2.74 43.75 0.9656 0.8810
Median filtering graphic file with name sensors-24-07649-i003.jpg 3.10 43.22 0.9684 0.0154