Table 5.

Nocturnal hypoglycemia warning results of different models on the OhioT1DM dataset

Early warning model Accuracy Recall Missed False F1-score Training time
(Unit: Seconds)
FLOPs
(Unit: K)
Proposed model 98.4% 94.12% 5.88% 1.43% 96.21% 50.02 175.58
Threshold warning 98.87% 75.74% 24.26% 0.24% 85.77% 0.33 1.16
RF 98.43% 87.5% 12.5% 1.15% 92.64% 1.21 18.8
SVM 98.13% 92.65% 7.35% 1.66% 95.31% 1.13 18.6
Traditional features 98.61% 89.71% 10.29% 1.05% 93.95% 33.00 115.05