Skip to main content
. 2024 Dec 19;24:307. doi: 10.1186/s12874-024-02426-9

Table 8.

Validation sample results for AF detection

FSM AUC Sensitivity Specificity NSF Runtime (s)
FULL 95.48 91.26 99.7 16 0.00
CFS 99.51 98.61 96.33 3 0.11
CHI2 95.28 90.90 99.67 15 0.83
GAMMA_BACK 98.74 95.08 97.40 7 2.12
GAMMA_BF 98.74 95.08 97.40 7 0.91
GAMMA_FORW 98.74 95.08 97.40 7 0.80
LASSO 91.27 82.87 99.66 7 20.84
RFI 66.22 56.52 79.36 1 178.29
STEP 98.27 94.75 98.07 6 52.84
SU 95.28 90.90 99.67 15 0.87
SVM-RFE 93.46 87.17 99.75 14 43.97

The best value of each indicator is highlighted with bold and underline. The second-best value is highlighted in bold. The indicators for the FULL model are not highlighted in the table since the focus of the study is to compare the feature selection methods

Abbreviation: NSF Number of Selected Features