Skip to main content
. 2024 Dec 18;24:337. doi: 10.1186/s12880-024-01453-8

Table 13.

Comparison of the proposed model with existing works

Ref Accuracy Sensitivity Precision MCC F1 score
[19] 79.4 79.45 78.95 74.8 79.1
[46] 93.6 - - - -
[24] 95.69 96.28 94.02 94.19 95.08
[47] 96.85 96.66 97.12 - 96.88
[48] 96 - - - -
[49] 94
Our 98.07 98.12 98.18 96.15 98.10