Skip to main content
. 2024 Dec 13;20(24):10886–10898. doi: 10.1021/acs.jctc.4c01240

Table 3. Metrics for CMA-2A Performance of the 1501 CCSD(T)/cc-pVTZ Benchmark Frequencies as a Function of the ξ Cutoff and the Choice of Level Ba.

  B = MP2/cc-pVTZ
B = CCSD(T)/cc-pVDZ
B = B3LYP/6-31G(2df,p)
ξ Cutoff MAE ϵ ϵmax σϵ ϵMAX η (%) MAE ϵ ϵmax σϵ ϵMAX η (%) MAE ϵ ϵmax σϵ ϵMAX η (%)
0.11 0.54 0.49 9.34 0 0.22 0.74 0.45 3.96 0 0.16 0.59 0.36 3.42 0
0.20 0.099 0.45 0.40 7.12 0.6 0.22 0.73 0.45 3.96 0.5 0.16 0.58 0.36 3.42 7.7
0.18 0.099 0.45 0.40 7.12 0.7 0.22 0.73 0.45 3.96 0.5 0.16 0.58 0.36 3.42 7.8
0.16 0.093 0.40 0.37 7.12 0.8 0.22 0.73 0.45 3.96 0.6 0.16 0.58 0.36 3.42 7.9
0.14 0.093 0.40 0.37 7.12 0.8 0.22 0.73 0.45 3.96 0.9 0.16 0.58 0.35 3.42 8.1
0.12 0.081 0.33 0.25 3.67 1.0 0.22 0.72 0.45 3.96 1.0 0.16 0.58 0.35 3.42 8.4
0.10 0.080 0.32 0.25 3.67 1.3 0.21 0.72 0.44 3.96 1.4 0.16 0.56 0.35 3.42 8.8
0.08 0.079 0.32 0.25 3.67 1.9 0.21 0.73 0.44 3.96 1.8 0.15 0.55 0.35 3.42 9.3
0.06 0.070 0.27 0.21 3.55 4.3 0.21 0.71 0.44 3.96 3.1 0.15 0.55 0.35 3.42 11
0.04 0.059 0.22 0.18 2.78 11 0.19 0.62 0.39 2.87 8.2 0.15 0.53 0.34 3.42 14
0.02 0.047 0.17 0.15 1.81 33 0.13 0.40 0.28 2.56 29 0.12 0.39 0.28 2.77 33
0.01 0.036 0.14 0.13 1.81 76 0.10 0.29 0.23 2.66 63 0.08 0.25 0.20 2.77 71
0.005 0.022 0.10 0.11 1.81 135 0.07 0.24 0.20 2.68 121 0.06 0.20 0.18 2.77 132
a

See footnotes to Tables 1 and 2 for definitions of the metrics. Level C = HF with the same basis used for Level B.