PZS deviation comparison between experimental and analytical (FEA) results under static loading conditions.

Time Load PZS Deviation comparison for experiment vs. analytical (FEA) under static loading condition
mm
minutes kN Experiment (S1E) Analytical (FEA) (S1A) Total deviation S1 (S1E–S1A) Experiment (S2E) Analytical (FEA) (S2A) Total deviation S2 (S2E–S2A) Experiment (S3E) Analytical (FEA) (S3A) Total deviation S3 (S3E–S3A) Total Deviation Average (S1, S2, S3)
0 0 0.00 0 0 0.00 0 0 0.00 0 0 0
1 10 1.12 0.812 0.308 2.31 0.812 1.508 1.20 0.773 0.407 0.741
2 20 1.80 1.523 0.277 2.94 1.608 1.332 1.76 1.568 0.192 0.600333
3 30 2.15 2.384 0.234 3.26 2.405 0.855 2.23 2.248 0.018 0.369
4 40 2.93 3.081 0.151 4.18 3.201 0.979 2.85 2.926 0.076 0.402
5 50 3.35 3.484 0.134 4.92 3.998 0.922 3.34 3.846 0.506 0.520667
6 60 4.17 4.679 0.509 5.87 4.795 1.075 4.27 4.540 0.270 0.618
7 70 4.98 5.416 0.436 6.77 5.592 1.178 4.89 5.384 0.494 0.702667
8 80 5.72 6.254 0.534 7.60 6.388 1.212 5.75 6.189 0.439 0.728333
9 90 6.53 7.120 0.590 8.87 7.185 1.685 6.45 6.842 0.392 0.889
10 100 7.15 7.818 0.668 9.98 7.981 1.999 7.23 7.695 0.465 1.044
Total average % 0.601364