Table 5. Comparisons of the mean values of the impulses recorded by the Lameness detector 0.1 on its three axes according to the lame hindleg of the assessed horses, regardless of their lameness scores, before and after intra-articular anesthesia.
Lameness leg | Number of horses | Mean number of impulses before joint block Mean ± SD (Median) |
Mean number of impulses after joint block Mean ± SD (Median) |
p |
---|---|---|---|---|
In the right hindleg, X axis | ||||
Right hindleg only | 8 | 90.18 ± 2.81 (89.00) | 85.25 ± 7.87 (88.00) | 0.121 |
Left hindleg only | 9 | 66.03 ± 0.48 (66.00) | 69.07 ± 9.36 (66.00) | 0.360 |
Both hindlegs | 25 | 93.68 ± 6.57 (94.00) | 86.12 ± 7.67 (89.00) | <0.001* |
In the left hindleg, X axis | ||||
Right hindleg only | 8 | 66.25 ± 0.46 (66.00) | 66.13 ± 0.35 (66.00) | 0.351 |
Left hindleg only | 9 | 93.67 ± 7.65 (93.00) | 86.00 ± 7.55 (89.00) | 0.030* .<< |
Both hindlegs | 25 | 93.76 ± 7.68 (93.00) | 83.84 ± 9.16 (89.00) | <0.001* |
In the right hindleg, Y axis | ||||
Right hindleg only | 8 | 65.13 ± 1.73 (65.50) | 66.50 ± 0.53 (66.50) | 0.064 |
Left hindleg only | 9 | 66.30 ± 0.45 (66.0) | 65.16 ± 1.68 (66.00) | 0.131 |
Both hindlegs | 25 | 64.86 ± 1.40 (65.00) | 66.96 ± 3.92 (67.00) | 0.010* |
In the left hindleg, Y axis | ||||
Right hindleg only | 8 | 66.00 ± 1.07 (66.00) | 64.38 ± 3.46 (66.00) | 0.311 |
Left hindleg only | 9 | 64.11 ± 1.36 (64.00) | 66.11 ± 1.69 (67.00) | 0.028* |
Both hindlegs | 25 | 64.28 ± 1.46 (64.00) | 65.98 ± 1.33 (67.00) | <0.001* |
In the right hindleg, Z axis | ||||
Right hindleg only | 8 | 63.78 ± 1.17 (64.00) | 63.38 ± 0.92 (64.00) | 0.530 |
Left hindleg only | 9 | 62.23 ± 0.38 (62.00) | 62.33 ± 1.00 (62.00) | 0.701 |
Both hindlegs | 25 | 64.01 ± 1.32 (64.20) | 63.60 ± 1.19 (64.00) | 0.099 |
In the left hindleg, Z axis | ||||
Right hindleg only | 8 | 61.88 ± 0.35 (62.00) | 61.88 ± 0.35 (62.00) | - |
Left hindleg only | 9 | 63.33 ± 1.58 (64.00) | 63.56 ± 0.73 (64.00) | 0.753 |
Both hindlegs | 25 | 63.48 ± 1.48 (64.00) | 63.36 ± 1.04 (64.00) | 0.768 |
Note: * For p-values <0.05, the difference between the mean impulse values is significant.
The missing p values were due to identical mean values of impulses before and after the intra-articular anesthesia (t could not be calculated).