Skip to main content
. 2024 Dec 30;24:1571. doi: 10.1186/s12903-024-05395-z

Table 3.

Volume and surface area measurements after crown-root fusion with IOS and CBCT compared to laser scanning

Voxel size (mm) Thresholds
(HU)
Volume Surface Area
Mean Vol ± SD(mm3) Difference ± SD(mm3) Deviation%(%) P-value Mean SA ± SD(mm3) Difference ± SD(mm2) Deviation%(%) P-value
0.3 mm 800 544.96 ± 202.20 42.82 ± 16.52 8.77% 0.000 433.42 ± 112.06 16.52 ± 4.90 4.15% 0.000
1000 535.11 ± 198.25 32.90 ± 12.13 6.83% 0.000 429.53 ± 112.21 12.63 ± 4.11 3.16% 0.000
1200 525.73 ± 195.56 23.52 ± 9.85 4.88% 0.000 425.11 ± 111.56 8.21 ± 3.92 2.07% 0.000
1400 516.64 ± 193.10 14.43 ± 7.27 2.96% 0.000 420.90 ± 111.08 4.00 ± 3.95 1.01% 0.000
1600 508.69 ± 190.92 6.48 ± 5.40 1.29% 0.000 417.38 ± 110.98 0.48 ± 3.68 0.12% 0.197
0.15 mm 800 527.17 ± 195.77 24.96 ± 7.67 5.10% 0.000 427.42 ± 112.24 10.53 ± 3.05 2.59% 0.000
1000 519.54 ± 193.36 17.33 ± 5.62 3.54% 0.000 424.16 ± 111.63 7.26 ± 2.64 1.79% 0.000
1200 512.91 ± 191.38 10.70 ± 4.13 2.17% 0.000 420.80 ± 111.01 3.90 ± 2.05 0.97% 0.000
1400 505.64 ± 189.44 3.43 ± 3.41 0.67% 0.000 416.99 ± 110.17 0.10 ± 2.40 0.05% 0.513
1600 498.05 ± 187.19 -4.15 ± 4.03 -0.90% 0.000 414.19 ± 110.01 -2.71 ± 2.26 -0.66% 0.000
laser model 502.21 ± 188.75 416.90 ± 110.95

P-value: Mean crown-root fusion model volume/surface area vs. mean laser model volume/surface area