Skip to main content
. 2025 Jan 2;15:18. doi: 10.1038/s41598-024-84605-8

Table 6.

IESO four-season typical day operating scenario for each equipment.

Typical day Electricity (kW) Heat (kW) Cold (kW)
WT PV GT EC FC ESS Buy WHB GB FC HSS AC AC EC
Spring 14,515 6063 14,328 − 4266.5 61.2 940.8 0 22,087 2061.1 61.2 1220.9 − 1780.9 2137.1 13,652
Summer 9700 5960 18,030 − 1551.5 50.7 850.6 2385.4 27,792 0 50.7 818.9 − 15690 18,828.1 4964.9
Autumn 12,942 6431 14,120 − 3311 19.7 1130.3 0 21,765 1118 19.7 736.8 − 4440.4 5328.5 10,595.3
Winter 17,162 3893 14,413 − 2986 73.8 1013.1 0 22,217 7045.7 73.8 1184.9 − 635.9 763.1 9556.6