Skip to main content
. Author manuscript; available in PMC: 2025 Jan 5.
Published in final edited form as: Med Phys. 2023 Jul 14;50(9):5375–5386. doi: 10.1002/mp.16625

TABLE 1.

Summary of mean clinical target volumes and mean numbers of spots and simulated particles for patients with different treatment sites.

Head and neck Lung Prostate
Clinical target volume (CTV) 164.1 ± 209.9 cm3 302.2 ± 114.3 cm3 48.1 ± 23.5 cm3
Numbers of beams 5a 3b 3c
Numbers of spots 2119 ± 1274 3036 ± 1554 3368 ± 1304
Numbers of simulated particles 2.03 × 108 ± 9.28 × 107 1.43 × 108 ± 2.96× 107 1.68 × 108 ± 7.50 × 107
Range uncertainty 3.5% 5.0% 3.5%
Positional uncertainty 3 mm 5 mm 5 mm
a

Median number. For HN treatment, six plans used five beams and the other two plans used four and six beams.

b

Median number. For lung treatment, three plans used three beams and two plans used four beams. The remaining two plans used two and five beams.

c

Median number. For prostate treatment, all plans used three beams.