Skip to main content
iScience logoLink to iScience
. 2024 Dec 4;28(1):111533. doi: 10.1016/j.isci.2024.111533

Modeling virus filtration: Materials, applications, and mechanism

Hironobu Shirataki 1,∗, Linda Gudex 2, Sumith Ranil Wickramasinghe 3,4,∗∗
PMCID: PMC11728907  PMID: 39807163

Summary

While various methods are employed to ensure the virus safety of finished products, virus filtration (VF) stands out as the preferred method for virus removal and purification of a wide variety of products owing to its capability of separating product molecules with more than 90% recovery and no change in molecule characteristics. The modeling of the virus removal process for VF membranes is based on the principles of microfiltration (MF) and ultrafiltration (UF), but with modifications for the much narrower separation difference, which is less than 2-fold for the separation of product molecules and virus particles. In this review, we introduce the materials and application of VF highlighting the unique characteristics properties of VF membranes through the steps of invention and subsequent development. We examine the virus removal mechanism and filtration models for VF to reproduce and predict the filtration behavior and virus reduction.

Subject areas: Materials application, Materials science, Membranes

Graphical abstract

graphic file with name fx1.jpg


Materials application; Materials science; Membranes

Introduction

Various methods have been employed to remove and inactivate viruses in biopharmaceutical products. Chemical treatment by the solvent/detergent (S/D) method, which is widely used to reduce microbial load, is also effective for inactivating enveloped viruses.1,2,3,4 It should be noted that S/D treatment is effective for inactivating only enveloped viruses but not nonenveloped viruses. Physical treatment by UV exposure is effective for inactivating virus in water or air,5,6,7 but the high likelihood of protein denaturation makes this method unsuitable for biopharmaceuticals.8 Likewise, virus inactivation by low pH or high temperature, which is regularly used during biopharmaceutical production mostly to target enveloped virus, increases the likelihood of forming protein aggregates or denatured products.9,10 Chromatography relies on specific interactions between virus and the resin, limiting removal to virus species with certain physicochemical characteristics.11,12,13

Unlike acid, heat, or UV treatments, virus filtration (VF) reliably removes almost all types of viruses based on size difference without denaturing the target protein. Furthermore, unlike S/D treatment, VF can remove viruses whether they are enveloped or nonenveloped, and, unlike chromatography, removal performance is independent of specific interactions. Owing to a multilayer membrane structure, which is different from normal ultrafiltration (UF) membranes, VF membranes can reliably remove viruses by a size exclusion mechanism while maintaining a high protein recovery and stable flux.14,15 Based on these advantageous properties, virus removal by filtration has been recognized by the Food and Drug Administration as an essential process for the virus safety of plasma protein and recombinant protein processes.16

Biopharmaceutical applications

In biopharmaceutical production, microfiltration (MF) is effective for bioreactor clarification by removing precipitates and solids, and UF is used for solution concentration and buffer replacement. However, since MF and UF cannot simultaneously provide high protein recovery and virus removal, VF is an essential downstream process for biopharmaceutical processes.17,18

Plasma proteins

Plasma-derived medicinal products (PDMPs) are produced by chromatographic isolation of target plasma proteins from fractionated plasma followed by multiple steps of virus inactivation and virus removal to ensure the safety of the pharmaceuticals.15,19 As there is a risk of viral contamination through infected blood donors, the manufacturing process for PDMPs is required to demonstrate a high degree of removal of HIV, hepatitis B and hepatitis C viruses. Virus inactivation methods for these products include heat treatment,20 S/D treatment,21,22,23 low pH treatment,24 and caprylic acid inactivation.25

In the 1990s, nanofiltration by virus filter was incorporated into PDMP manufacturing processes as a complementary step to ensure virus removal by a size exclusion-based mechanism.19,26,27,28,29 The first virus filter having a nominal pore size of 35 nm was developed by Asahi Kasei and became available for virus removal in plasma protein processes in 1989. Subsequently developed virus filters with nominal pore sizes of 15 and 20 nm (small virus-retentive filters) and 35 and 50 nm (large virus-retentive filters) from multiple manufacturers have become integrated as an essential part of PDMP manufacturing processes,30,31,32,33 and VF is now recognized as the most important and robust process for removing viruses from PDMPs. Today, VF is a standard operation in the manufacturing processes of PDMPs, such as immunoglobulins (immunoglobulin G [IgG]),34,35,36,37 inhibitors alpha1-protease inhibitor (A1PI),38,39 antithrombin (ATIII),40 and C1-esterase inhibitor,41,42,43 and coagulation factors von Willebrand factor,44 Factor VIII,45,46 Factor IX, and prothrombin complex.28,47

Recombinant proteins

In addition to purifying proteins from human plasma, many therapeutic proteins are produced using genetically modified cells in vitro. Originally produced using bacterial cells, this technology has also been extensively developed to utilize mammalian and other animal cell lines. For all products from animal cell lines, there are regulatory requirements that the manufacturing processes include steps that remove or inactivate viruses.48 VF is one of the most effective and robust means to achieve this goal as shown for a typical monoclonal antibody (mAb) purification process (Figure 1).

Figure 1.

Figure 1

Schematic showing recombinant protein production process representative of mAb production

Early recombinant purification trains utilized large virus-retentive filters with a focus on the removal of retroviruses and retrovirus-like particles, which are endogenously produced by many animal cells, including the Chinese hamster ovary cells used to produce most recombinant biotherapeutics.49,50 However, in parallel, small virus-retentive filters (15 and 20 nm) were being introduced to the marketplace, as there was evidence that parvoviruses, which are about 22 nm in diameter, posed a significant risk of contaminating mammalian cell cultures.51,52 Since these nonenveloped viruses are also highly resistant to inactivation, incorporation of small virus-retentive filters became common as a solution to ensure removal of these potential contaminants. Given the importance of this step in product safety, many members of the pharmaceutical industry have actively engaged in workshops and symposiums to share their experiences with VF and other viral clearance operations.53,54,55,56 Those studies confirmed that small virus-retentive filters are able to simultaneously remove both retroviruses (large viruses) and parvoviruses (small viruses) in biopharmaceutical manufacturing processes; consequently, newer manufacturing facilities rely only on small virus-retentive filters.

Although recombinant therapeutics include many different types of proteins, the vast majority of recombinant protein products on the market and in development are mAbs. With a hydrodynamic diameter of approximately 9–12 nm, the size of these molecules is close to that of the 20 nm pores of small virus-retentive filters.

Membrane morphology

Products and materials for major commercial virus filters

Utilizing technological advances to control membrane pore size,57 Asahi Kasei launched the first commercial filter (large virus-retentive filter) with a porous hollow fiber membrane made of cuprammonium regenerated cellulose in 1989 and enabled “virus removal from protein solution by membrane filtration.” Since the launch of the first filters, VF for removal of viruses from protein solutions has become one of the critical modern technologies to assure robust virus safety of biological products.58 In subsequent years, many other types of virus filters have been developed as shown in Table 1 to target removal of different types of viruses. Figure 2 shows the recent lineup of hollow fiber-type Planova virus filters. These filters have porous hollow fiber membranes, and the pore size distribution of each membrane is designed to trap viruses based on size while allowing the target protein product to pass through.

Table 1.

Launch and characteristics of commercially available virus filters

Manufacturer Brand name Product name Market launch Structure Material Virus-retentive capability
Asahi Kasei Planova 35N 1989 hollow fiber (assymmetric) cellulose large
15N 1993 small
20N 2001
BioEX 2009 PVDF
S20N 2021 cellulose
MilliporeSigma Viresolve NFR 2002 flat sheet
2- or 3-layer laminate
PVDF large
NFP 2001 small
Pro 2008 PES
Pall Ultipore DV50 1989 flat sheet
2-layer laminate
PVDF large
DV20 2000 small
Pegasus SV4 2012
Sartorius Virosart CPV 2004 flat sheet
2-layer laminate
PES small
HC 2010
HF 2013 hollow fiber

PVDF, polyvinylidene fluoride; PES, polyethersulfone.

Figure 2.

Figure 2

Planova 20N, BioEX, and S20N filters in various sizes showing the structure of hollow fiber filters

Micrographs are included for purposes of showing the detail of the structure not technical specifications of the filter membrane.

Virus filters composed of hollow fibers or flat sheets made from various materials with differing pore sizes59 are currently available on the market (summarized in Table 1) and are adopted with high effectiveness in many pharmaceutical processes, particularly for plasma proteins and recombinant protein production. These virus filters can be separated into two classes: large virus-retentive filters that remove viruses with diameters of 50 nm and greater and small virus-retentive filters that remove viruses with diameters of 20 nm and greater. The hollow fiber type is characterized by good scalability across filter sizes, generally lower fouling, and the ease of removing air from the filter for more stable filtration, while the flat sheet type is characterized by good dead space control and lower capital cost per device, although hollow fiber modules may be more economical overall due to higher capacity.

Filters are constructed from either a single layer or up to three-layer laminates from either hydrophilic polyvinylidene fluoride (PVDF), hydrophilic polyethersulfone (PES), or regenerated cellulose polymers. PVDF and PES polymer materials are naturally hydrophobic and are modified to be more hydrophilic to decrease protein binding.60,61 These polymer materials have relatively high mechanical strength and chemical resistance, while cellulose has particularly high biocompatibility. In addition, membranes can be formed by phase inversion using the combination of good and poor solvents, making it easy to form porous materials with controlled pore size. Hollow fibers are basically single-layer structures as they are produced by a wet spinning process, while flat sheet membranes often employ a laminated membrane structure in which a thin active layer that captures viruses is strengthened by a thicker support layer having relatively large pore size.

The membranes may be symmetric or asymmetric in structure.62 The thin active layer of laminated membranes tends to have a symmetric structure, while hollow fiber membranes generally have an asymmetric structure, mainly due to differences in the phase inversion process during membrane formation. Membrane fouling, mainly caused by protein aggregates, can significantly reduce filterability. Flat sheet membrane virus filters having a thin active layer often experience a significant reduction in flux due to fouling. In such cases, the use of a prefilter such as Viresolve Pro Shield (MilliporeSigma) or Virosart Max (Sartorius) is essential for removing fouling material from the feed stream and maintaining filterability of the virus filter.

The performance of virus filters is closely linked to the pore structure of the membrane, but, while filter structure and material are disclosed by manufacturers, membrane thickness and pore size distribution are typically not disclosed. It is important to note, however, that, although differences between different filter types can impact performance, published data support the high degree of effectiveness and robustness of virus removal across a broad range of users and products for all vendors.63

Currently, work in the field of VF is focused on developing additional filter types to better satisfy demands for increased process efficiency and capability with varied product streams while maintaining robust virus safety. To aid in filter development and to better predict the outcome of filtration processes, models based on the filtration mechanism are being developed.

Mechanisms of viral clearance by filtration

While VF and UF membranes have a similar nominal pore size, VF needs to be capable of both robust virus removal and high target protein recovery. As shown in Figure 3,64 high virus LRV (logarithmic reduction value) for representative viruses on Planova 20N and BioEX filters shows that LRV of 4 or higher can be achieved based on the size exclusion mechanism.65,66,67 Notably, VF is able to achieve LRV of 4 and higher while allowing a protein that is almost half the size of the representative virus particles to pass through. This capability is an important feature of VF membranes that is not available for UF.

Figure 3.

Figure 3

Reported virus LRV for viruses of various diameter on two different filters

(A) Virus LRV using Planova 20N filters.

(B) Virus LRV using Planova BioEX filters.

Planova filters and other filters with similar moderately asymmetric membrane structures achieve a high level of performance due to their complex interconnected three-dimensional structures described by the “void and capillary model.” Normal positive scanning electron microscopy (SEM) imaging of the membrane (Figure 4A) shows the membrane material as bright regions, and, in the negative SEM image (Figure 4B) produced by embedding an epoxy resin into the cellulose membrane followed by dissolving the membrane with cuprammonium solution, the voids and capillaries are shown as the bright region. The connectedness shown in Figure 4B suggests that the VF membrane has a 3-dimensional interconnected network structure represented schematically in Figure 4C as a “void and capillary structure.”68,69

Figure 4.

Figure 4

SEM image and schematic of virus filter membrane structure

(A) Positive image SEM.

(B) Negative image SEM.

(C) Schematic of the complex void and capillary structure. Micrographs are included for purposes of showing the detail of the structure not technical specifications of the filter membrane.

The void and capillary structure effectively describes the virus filter structure, but this is not a sufficiently detailed model for numerically representing virus reduction by the virus filter. To conceptually understand the robust virus reduction, the “multilayer model” or “multi-step filtration” as shown in Figure 5 is proposed.14,15

Figure 5.

Figure 5

Schematic of the multilayer model showing the trapping of virus particles but not protein across numerous layers of the virus removal filter

In the multilayer model, feed solution is forced to pass through several hundred layers, each with a porous structure with a particular pore size distribution, and, at each layer, a subset of virus particles is trapped while the slightly smaller target protein passes through the membrane unimpeded. Even if only a portion of the virus particles are trapped in each layer, a membrane that consists of many layers will achieve very high removal of virus particles. For example, even if 90% of the virus passes through one layer, the virus concentration will decrease to 0.9100 = 2.65 × 10−5 by passing through 100 layers. Virus filters with multilayer membrane structures have been proven to show robust virus removability.18,65,70

The structural properties of membranes have been postulated to have important impacts on filter fouling.71 For membranes with an asymmetric structure,72,73,74,75 the feed solution enters the feed side of the membrane that has larger pores, and, as the solution moves through the membrane with gradually decreasing pore size, product impurities or aggregates are removed from the feed solution. As impurities are largely removed by the larger pores, the smaller pores responsible for virus entrapment remain available, and this process permits robust viral reduction while maintaining high protein recovery and stable filterability. Membranes with relatively symmetric pore structure capture most of the virus near the entry to the membrane, while membranes with highly asymmetric pore structure capture virus at a skin-like layer near the membrane exit.71,72 Although the filtration mechanisms of these different membrane types have not been studied in sufficient detail, membrane structures along with membrane material are likely to result in a wide range of performance characteristics observed for different virus filters.

Filtration models for VF

Analyzing, reproducing, and predicting the performance of membranes, that is, pressure rise in constant flux filtration and flux decay in constant pressure filtration, are important for understanding and designing filtration processes. The following section presents the main models that have been published to quantitatively express the filtration or virus removal properties of VFs (blocking models, internal polarization model, and multilayer models).

Blocking model

Classical blocking model

The blocking model is an effective filtration model that is still widely used today, and it has been continuously improved over the years. The classical blocking model assumes that the pores of the membrane are a collection of cylinders with a uniform pore diameter and a circular pore cross-sectional shape and that the surface layer with uniform structure is the active layer of the membrane. The initial blocking model concept, which was based on the Hagen-Poiseuille equation and was formally proposed in 1936 by Hermans and Bredée,76 classified the causes of filterability decrease during separation processes into three models (or categories): cake, standard, and complete. In 1956, Grace77 systematized the blocking model by introducing the Kozeny-Carman equation by which filtration behavior for all blocking mechanism is expressed by two characteristic equations, one for constant pressure filtration (Equation 1) and the other for constant flux filtration (Equation 2):

d2tdv2=k(dtdv)n (Equation 1)
dpdv=k′pn (Equation 2)

where t is filtration time, v is filtrate volume, p is filtration pressure, k is characteristic form coefficient, and n is blocking index. The filtration can be characterized as one of four blocking models, i.e., complete blocking, standard blocking, intermediate blocking, and cake filtration with a blocking index, n, of 2, 1.5, 1, and 0, respectively.

The filtration equations for each model can be expressed as simple equations with flux as a function of filtration volume (Equations 3 to 6 in Table 2) for constant pressure control or with pressure as a function of filtration volume (Equations 7 to 10 in Table 2) for constant flux control with k for each model designated by subscript b for complete blocking, s for standard blocking, i for intermediate blocking, and c for cake filtration and the prime symbol distinguishing k for constant flux filtration equations. The filtration equations in Table 2 represent the blocking mechanism of each filtration model. Furthermore, differentiating the equations reduces all models to the same characteristic form; i.e., Equations 3 to 6 reduce to Equation 1 and Equations 7 to 10 reduce to Equation 2.77,78

Table 2.

Equations and characteristic form coefficients for filtration models for constant pressure and constant flux filtration of Newtonian fluids-solids mixtures

Filtration model Complete blocking Standard blocking Intermediate blocking Cake filtration
Blocking mechanism accumulation at pore entrances even decrease of the available pore diameter accumulation on already trapped substances at pore entrances adherence to pore surfaces forms new flow paths
Blocking index, n 2 3/2 1 0

Constant pressure filtration: Evaluating performance based on a decrease in flux

J=f(v) kbv=J0–J (Equation 3) J=J0(1−ks2v)2 (Equation 4) J=J0exp(−kiv) (Equation 5) kcv=1J−1J0 (Equation 6)
k in Equation 1 k=kb k=J01/2ks k=ki k=kc

Constant flux filtration: Evaluating performance based on a rise in pressure

p=f(v) p0p=1−kb′J0v (Equation 7) (p0p)1/2=1−ks′2v (Equation 8) ln(pp0)=ki′v  (Equation 9) pp0=kc′J0v+1  (Equation 10)
k′ in Equation 2 k′=kb′J0p0 k′=p0−1/2ks′ k′=ki′ k′=J0p0kc′

Bolded letter in filtration model name is used to distinguish k, characteristic form coefficient, in filtration equations.

Note that the k and k′ are specific to each model. The relationship between the characteristic form coefficient k and k' for constant pressure (Equation 1) and constant flux (Equation 2), respectively, and that for each of the filtration models is shown in Table 2.

By determining specific n and k or k' values that reproduce the filtration behavior, it is possible to classify the filtration mechanism and predict the filtration behavior when the filtration volume is increased. However, since k' cannot be determined from k, it is not possible to predict constant pressure filtration behavior from constant flux data, or vice versa.

This model is frequently used to describe MF and UF, though the accuracy depends on how well the underlying assumptions are met. The blocking model systematized by Grace has been applied to the analysis of many filtration phenomena due to its easy-to-understand concept and ease of analyzing filtration data. In further development for application to non-Newtonian liquids79 or to account for cross-sectional pore shapes other than circular,80,81 it has been shown that n can take any positive value while the characteristic form coefficient remains unchanged.

In 2022, Zydney82 derived equations for a strict blocking model for membranes having a three-dimensionally interconnected pore structure rather than a collection of uniform cylinders. Incorporating consideration of membrane morphology into characteristic form (Equation 1) for the blocking model results in Equation 11.

d2tdv2=kbJ02/3(1−β)[23+βJ0(dtdv)](dtdv)5/3 (Equation 11)

where β is the ratio of the permeabilities of the dispersed and continuous phases.

Although the blocking model systematized by Grace has been developed in various ways, the conventional classical blocking model formula is still widely used to analyze filtration due to its simplicity and ease of handling. In 1995, Badmington et al.83 introduced the concept of Vmax as the maximum filtration volume of MF and proposed that Vmax can be calculated from the initial filtration behavior based on the standard blocking model. Bolton et al.84 extended this concept of Vmax to VF membranes, which have a much denser structure than MF membranes, and showed that the maximum filtration volume can be estimated even for VF. Specifically, when applying the standard blocking filtration model Equation 4 in Table 2 to constant pressure VF operation, the filtration volume v at which J = 0 is Vmax = 2/ks. In 2020, Emami et al.85 reported the analysis of the fouling phenomenon of normal flow in MF using a conventional blocking model and developed a new model based on the intermediate pore blockage phenomenon taking into account the highly interconnected pore structure of the membrane.

Combined blocking models

For actual filtrations, n from the classical blocking model does not necessarily classify the filtration into any of the four filtration mechanisms of the classical blocking model.79,80,81 This suggests that actual filtration phenomena do not necessarily fit only one particular model but may be better described by a combination of model mechanisms.

Ho and Zydney86 proposed a combined model that expresses the simultaneous occurrence of filtration behavior in accordance with the complete blocking and cake filtration models, showing that multiple filtration behaviors can coexist. In this combined model approach, n at t = 0 is expressed by three resistance parameters as

n=d[log(d2tdv2)]d[log(dtdv)]=3−Rm+Rp0Rp0+2Rm2Rp02(Rm+Rp0)⋅f'R'α (Equation 12)

where Rm is the resistance of the clean membrane, Rp0 is the resistance of a single protein aggregate, R′ is the specific protein layer resistance, f’ is the fractional amount of total protein that contributes to deposit growth, and α is the pore blockage parameter. Rp0 is considered to correspond to complete blocking, and R′ corresponds to cake filtration.

Calculations with this combined model for the constant pressure filtration of protein (BSA) on UF showed good agreement with experimental data, indicating that the flux decrease was caused by initial fouling due to pore blockage and subsequent fouling due to growth of a protein cake layer. Application of this combined model approach by Peles et al.87 to investigate the effect of pressure on the rate and mechanism of fouling formation in constant pressure filtration of IgG with Viresolve Pro showed that the extent of fouling (evaluated in terms of overall resistance at a given throughput) decreases and the filter capacity (evaluated using the Vmax model) increases with increasing pressure, and the flux decrease by fouling showed good agreement with the combination of complete blocking and cake filtration models. The same approach was applied to constant flux filtrations,88 and fouling data were confirmed to be well described by the same mechanistic model based on sequential pore blockage and cake filtration.

Bolton et al.89 further developed this idea and proposed five new fouling models to account for the combined effects of two different individual fouling mechanisms. As shown in Table 3, filtration equations for both constant pressure and constant flux filtration for these five models were derived from Darcy’s law. Each equation has two blocking constants corresponding to the fouling mechanism, and the value of n is incorporated in the equation. These blocking constants are fitting parameters, and experimental filtration data can be reproduced by fitting these two parameters. Applying these five filtration models to the filtration of BSA on Viresolve 180 showed that the combined cake-complete model was the best fit. Evaluation of these five models over a range of constant pressures and flow rates showed good model fit for the flow rate dependence of capacity.90 Furthermore, fitting these combined models to data obtained in the constant flow or constant pressure modes allowed prediction of capacity in the other mode.

Table 3.

Summary of the five combined fouling models

Constant pressure filtration: Evaluating performance based on a decrease in flux
Model Equation Fitted parameters
Cake-complete v=J0Kb(1−exp(−KbKcJ02(1+2KcJ02t−1))) Kc, Kb
Cake-intermediate v=1Kiln(1+KiKcJ0((1+2KcJ02t)1/2−1)) Kc, Ki
Complete-standard v=J0Kb(1−exp(−2Kbt2+KsJ0t)) Kb, Ks
Intermediate-standard v=1Kiln(1+2KiJ0t2+KsJ0t) Ki, Ks
Cake-standard v=2Ks(βcos(2π3−13arccos(α))+13)
α=827β3+4Ks3β3KcJ0−4Ks2t3β3Kc,β=49+4Ks3KcJ0+2Ks2t3Kc
Kc, Ks

Constant flux filtration: Evaluating performance based on a rise in pressure

Model Equation Fitted parameters

Cake-complete pp0=1(1−Kbt)(1−KcJ02Kbln(1−Kbt)) Kc, Kb
Cake-intermediate pp0=exp(KiJ0t)(1+KcJ0Kiexp(KiJ0t)−1) Kc, Ki
Complete-standard pp0=1(1−Kbt)(1+Ks′J02Kb′ln(1−Kb′t))2 Kb, Ks
Intermediate-standard pp0=exp(KiJ0t)(1−Ks2Ki(exp(KiJ0t)−1))2 Ki, Ks
Cake-standard pp0=((1−KsJ0t2)2+Kc′J02t) Kc, Ks

Generalized blocking model

As described in the previous section, when analyzing actual filtration phenomena, n does not necessarily fall into the classifications of any of the four classical blocking models, and, in cases where filterability is high, negative n values have even been reported.65,80,91,92,93,94 To develop a rigorous method for determining n and k, Shirataki65 proposed a generalized blocking model calculation method to apply experimental data directly to Equation 1 or Equation 2 regardless of the blocking model mechanism. The modified characteristic forms to determine parameters for constant pressure filtration and for constant flux filtration are derived as Equation 13 and as Equation 14, respectively.

ln(−dJdv)=(2−n)lnJ+lnk (Equation 13)
ln(dpdv)=nlnp+lnk (Equation 14)

From these equations, n and k are obtained from the slope and intercept of the ln(-dJ/dv) vs. ln J plot for constant pressure filtration and the ln(dp/dv) vs. ln p plot for constant flux filtration.

Equations to fit the filtration behavior using the obtained values of n and k are derived by integrating Equation 1 for constant pressure filtration and Equation 2 for constant flux filtration as follows.65

The generalized filtration equations for constant pressure filtration are

J=(J0n−1−(n−1)kv)1(n−1)forn≠1 (Equation 15)
J=J0exp(−kv)forn=1 (Equation 16)

The generalized filtration equations for constant flux filtration are

p=(p01−n+(1−n)kv)11−nforn≠1 (Equation 17)
p=p0exp(kv)forn=1 (Equation 18)

The generalized filtration equations are independent of the four classical blocking mechanisms, and these equations can be used to theoretically reproduce the experimental filtration behavior using the determined n and k using Equations 15 and 16 for constant pressure and constant flux filtrations, respectively.

Figure 6 shows experimental data for constant pressure filtration93 and curves calculated using Equation 15. In the experiment, IgG solutions prepared to have different filterability by controlling the level of aggregates were filtered on hollow fiber virus filters (Planova BioEX). Similarly, Figure 7 shows the experimental data and the curve calculated using Equation 17 for constant flux filtration94 in which highly purified mAb solution was filtered through a Planova BioEX filter. In both cases, the determined n values are noted in the figure and are shown along with ln k in Table 4. The curve calculated using the generalized filtration equation is in good agreement with experimental data in both cases.65 Figure 6 shows that filtration runs with a stable filtration curve and low flux decrease have a negative n value (n = −2.26 for the no aggregates addition and n = −4.36 for the high aggregates removal runs), whereas conditions with higher flux decrease have a positive n value and are approximately classified as intermediate mechanism (n = 1.20 for the less aggregates removal run) or complete blocking mechanism (n = 2.49 for the aggregates addition run). Similarly, the filtration behavior for a highly purified mAb solution was quite stable with an extremely small pressure increase (Figure 7) and had a rather large negative n value (n = −32.0). Thus, stable filtration behavior with a high filterability filter tends to have a negative n that is constant throughout the filtration process.

Figure 6.

Figure 6

Constant pressure filtration behavior of various plasma IgG solutions with differing filterability

Symbols, experimental results; solid line, curve calculated by Equation 15.

Figure 7.

Figure 7

Constant flux filtration behavior of mAb solution showing experimental results and calculation by Equation 17

Table 4.

n and ln k obtained for various solutions for constant flux and constant pressure filtration

Filtration Solution n ln k
Constant pressure (11 mg/mL plasma IgG) no aggregates addition −2.26 −21.0
aggregates addition 2.49 4.55
high aggregates removal −4.36 −33.0
less aggregates removal 1.20 −3.93
Constant flux (10 mg/mL mAb) purified by column flowthrough −32.0 −84.2

As shown in Table 4, negative n values are associated with highly negative ln k, i.e., significantly small k values, and smaller ln k values are considered to correspond to smaller amounts of fouling materials.65 Negative n values also correspond with the run showing a decrease in fouling rate over the course of filtration, which can occur when the fouling mechanism changes sequentially during the filtration from a higher n mechanism (i.e., complete blocking) to a lower n mechanism (i.e., cake filtration), and this is the reason for the effectiveness of the combined model approach. Another possible explanation for a negative n value is that the fouling rate is less than that of any of the four mechanisms of the conventional blocking model and the existing blocking models, which are based on the membrane structure being characterized as a collection of uniform pore size cylinders, are not adequate to explain the fouling mechanism that produces the negative n.

Internal polarization model

LRV is the most important parameter of VF, and it cannot be obtained with the various blocking model approaches described here. Through observation of the retention distribution of fluorescently labeled PP7 in a virus filter (Ultipor DV20, Pall) using confocal microscopy, Jackson et al.95 showed that virus particles are not trapped in a highly concentrated polarization layer on the surface of the membrane as for MF and UF but, rather, a polarization layer is formed inside the membrane with a concentration distribution in the VF membrane. Therefore, they concluded that the virus removal mechanism of VF is that virus particles accumulate in the “reservoir zone” of the membrane upper layer and particles not captured in that layer are continuously transferred to the “rejection zone” in the lower layer by convective flow. Thus, they introduced the concept of a sieving model and mass balance and proposed an internal polarization model, which assumes that virus particles accumulate in the upper layer (reservoir zone or layer) within the membrane and, as the amount of virus particles transferred to the lower layer (rejection layer) increases, the particle trapping ability of the membrane decreases. This concept enables to quantitatively expresses virus LRV.

In this internal polarization model, the virus particle rejection layer of the virus filter is assumed to have a constant virus sieving constant, S, with S equal to the transmittance of virus passing through the rejection layer. It is also assumed that the virus filter reservoir layer has a constant volume, VR, and a uniform virus concentration, C. Here, C is the concentration of virus particles that freely move within the reservoir layer. The transient mass balance of virus particles that freely move within the reservoir layer is expressed by Equation 19.

VRdCdt=xqCF−qSC (Equation 19)

where q is the flux, CF is the concentration of virus particles in the feed solution, and x is the proportion of uncaptured viruses in the solution that enters the reservoir layer. In other words, if x = 1, no virus particles are captured and all stay in the reservoir layer, and, if x = 0, all virus particles are trapped in the pores in the reservoir layer by size exclusion and are no longer able to move freely. By integrating Equation 19 with CF, x, S, and VR as constants, virus LRV is given by the following equation.95,96

VirusLRV=−log10(CFiltrateCFeed)=−log10(S∗CCF)=−log10×−log10[1−exp(−SVVR)] (Equation 20)

where CFiltrate and CFeed are the virus particle concentrations in the permeate and feed, respectively.

Jackson et al.95 applied this internal polarization model to the results of a filtration in which PP7 was loaded on a virus filter and showed that the change in virus LRV by filtration volume can be well reproduced by optimizing and determining S and x using experimental results.

In experiments with bacteriophage ϕX174 on a virus filter (Pegasus SV4, Pall), Afzal et al.96 added a process disruption midway through the filtration such that the solution supply was stopped and restarted after a set period of time, and virus LRV was determined. In addition, virus LRV was determined for multiple filtrations conducted at different flow rates. The longer the process disruption duration and the lower the average flux, the smaller the virus LRV value. Changes in virus LRV were well reproduced by applying the internal polarization model and optimizing the parameters under each condition.

Although the internal polarization model cannot be used as a filtration model that analyzes filtration behavior in the same way as the blocking model, it is possible to analyze and reproduce the experimental results for virus LRV and it is useful for comparing and examining the effects of process disruption, flux, protein, etc. on virus LRV.

Multilayer models

Multilayer concept applied to the blocking model

The structure underlying the blocking model does not necessarily correspond to the actual structure of the virus filter. Therefore, it may not be appropriate to consider the mechanism of the negative n values only in the blocking model concept. To better represent VF membranes, multilayer models may be useful in order to incorporate the structure of the virus filter as (1) consisting of multiple active layers with a pore size distribution and (2) utilizing size exclusion as the primary mechanism for virus reduction.

Shirataki65 applied the multilayer model concept to the generalized blocking model and showed that the negative n value of the blocking model in the previous section obtained for a virus filter with high filterability can be explained. For simplicity in the multilayer model, it is assumed that each layer has two pore sizes, r1 and r2, with r1 small enough to capture the particle to be removed and the target protein size small enough to permeate both r1 and r2. The multilayer membrane consists of ℓ layers, all of which are identical.

From the Hagen-Poiseuille equation, flux, J, is expressed as J = πr4pN/8 μL, where N is the total number of pores. Using this relationship, p of one layer is approximated by the following equation for a membrane with pores of sizes r1 and r2.

p=8μLπ(r14N1+r24N2)J (Equation 21)

Where, N1 and N2 are number of pores of r1 and r2 in one layer, respectively. Here, f is defined as the probability of a particle being trapped in one layer. Since only r1 pores are blocked and the flux is the same for all layers, the transmembrane pressure of i-th layer, pi, is described by f and particle density, x, as

pi=8μLπJr14(N1−xvf(1−f)i−1)+r24N2 (Equation 22)

By differentiating 1/pi by v and accumulating from i = 1 to ℓ, a formula similar to Equation 2 is derived as follows.

dpdv=xπr148μLJ∑i=1lpi2(1−f)i−1 (Equation 23)

Equation 23 coincides with Equation 2 for the conventional complete blocking model (n = 2) when ℓ = f = 1. In Equation 2, for the complete blocking of membrane structure, constant k’ can be expressed as xπra4/8 μLJ where ra is average pore radius based on the pore cross-sectional area as ra2 = (r12N1 + r22N2)/(N1 + N2). Comparing Equations 2 and 23, n is related to ℓ and f as

pn=r14ra4∑i=1lpi2f(1−f)i−1 (Equation 24)

with p being the summation of pi for i = 1 to ℓ. Equation 24 suggests that n can be a negative value for a membrane with a multilayer structure with dependance on r1, r2, ℓ, and f. For example, assuming ℓ = 200, f = 0.1, r1 = 10 nm, ra = 50 nm, and p = 200 kPa with pi = 1 kPa for all the layers, n = −1.23 is calculated from Equation 24. LRV for f = 0.1 and ℓ = 200 is evaluated as 9.15 (=−log (0.9200)) for this simple model.

In this way, a negative value of n can be rationally explained by introducing a multilayer structure and non-uniform pore size to the complete blocking model in which particles are captured by size exclusion.

Homogeneous multilayer model

Shirataki and Wickramasinghe66 proposed a calculation method based on the homogeneous multilayer model to reproduce the filtration behavior. In this model, the VF membrane is considered to be composed of multiple layers each having an identical lognormal distribution of pore sizes.

Since the pore size distributions of UF and MF membranes are effectively described by a lognormal distribution,97,98 the pore size distribution of VF membranes is also assumed to be lognormal.

The lognormal distribution is given by97

Ni(0)=N(0)ƒ(ri)=N(0)1σ∗ri2πexp(−[ln(ri)−ln(R∗)]22σ∗2) (Equation 25)

where the initial number of pores is Ni(0) with equivalent pore radius ri (i = 1 to n). In Equation 25, N(0) is the initial total number of pores per unit membrane area, σ∗and R∗ are parameters expressed by variance, σ, and mean pore radius ra as follows:

ln(R∗)=12ln(ra4σ2+ra2) (Equation 26)
σ∗=ln(σ2+ra2ra2) (Equation 27)

The schematic representation of the homogeneous multilayer membrane and particles to be removed is shown in Figure 8.66 Solution is filtered from top to bottom, through layers with different configurations of pores but identical pore size distributions, and particles are removed by the size exclusion mechanism. The target protein is assumed to be smaller than all the pores in each layer and is not shown in the figure. In this model, the trapped particles are assumed to be spherical and uniform in size with a radius of Rp (virus, product aggregates, etc.) and are trapped by pores that are not assumed to be circular but that have effective openings less than twice Rp. Actually, the pore shapes are usually stretched from circular by the extension process during membrane formation. In other words, particles with diameter D (=2Rp) are trapped by the pores with openings less than D (sieving factor is 1) and pass through the pores with openings larger than D (sieving factor is 0).

Figure 8.

Figure 8

Schematic of the homogeneous multilayer membrane model

(A) Multilayer membrane with pore size distribution and particle removal.

(B) Multiple particles captured by a non-circular single pore with larger cross-section area than individual particles.

Thus, r is the “equivalent” radius of a non-circular pore with a cross-sectional area of πr2, and the opening of the pore may be less than 2r such that a particle can be trapped even when r > Rp. To define the maximum pore size that captures a particle, equivalent radius rB is introduced as the capture limit pore radius. Particles are trapped by pores with cross-sectional areas less than or equal to πrB2.

Given that pores have non-circular cross-section with a pore size distribution, the number of particles that can be captured by a pore depends on the cross-sectional area of the pore as shown in Figure 8B. The number of particles trapped by one pore is calculated as the cross-sectional area ratio of the pore to the particle. Based on these assumptions, when the filtration volume increases from v to v + Δv, the change in the number of i-th pores in the membrane is given by Equation 28.66

Ni(v+Δv)=Ni(v)−(RPri)2(πri2Ni(v)∑i=1nπri2Ni(v))cΔv (Equation 28)

Here, ri is the equivalent radius of the i-th pore according to the lognormal distribution, c is particle concentration (m−3), and cΔv is the total number of particles in volume Δv. It is assumed that, for pores with a larger radius (ri>rB), no particles are trapped and all particles pass through to the permeate, and, in this case, the number of pores in Equation 28 with radius ri>rB does not change during filtration. Therefore, for i > B,

Ni>B(v+Δv)=Ni>B(v)=Ni>B(0) (Equation 29)

By relating the decrease in the number of pores due to particles being trapped as the filtration progresses for the membrane using the Hagen-Poiseuille equation, change in flux, J(v), for constant pressure filtration and pressure, p(v), for constant flux filtration is given by

J(v)=∑i=1nNi(v)ri4∑i=1nNi(0)ri4J0 (Equation 30)

and

p(v)=∑i=1nNi(0)ri4∑i=1nNi(v)ri4p0 (Equation 31)

where, J0 is the initial flux for constant pressure filtration and p0 is the initial pressure for constant flux filtration.

Aggregates present in the feed solution are the particles that block pores in the multilayer membrane, thus reducing the available pore number and the filtration performance of the membrane. That is, from the decrease in the number of pores as the filtration volume increases, the flux decrease in the case of constant pressure filtration can be quantitatively expressed using Equation 30, and the pressure increase in the case of constant flux filtration can be quantitatively expressed using Equation 31.

In the calculation, fixed initial parameters were assumed as equivalent average pore radius (ra = 20 nm), variance (σ = 10), and initial total number of pores in the membrane (N(0) = 2.24 × 10−17 m−2 calculated from the porosity and assumed number of layers M = 500). These initial parameters were substituted in Equation 30 or 31, and the optimized parameters (c, RP, and rB) can be automatically determined using the spreadsheet software (Solver of Microsoft Excel) to reproduce the filtration behavior.

The results of applying homogeneous multilayer model Equations 30 and 31 to the experimental results analyzed by the generalized blocking model in Figures 6 and 7 are shown in Figure 9. Optimizing the parameters c, RP, and rB with the experimental results and calculations gives extremely good reproduction of the filtration behavior for both constant pressure filtration and constant flux filtration. The parameters along with aggregate ratio in the protein, ρ (%), which can be determined from RP and c, are summarized in Table 5. These results indicate that the solutions with lower filterability contain a higher proportion of larger-sized aggregates.

Figure 9.

Figure 9

Application of the homogeneous multilayer model to experimental results analyzed by the generalized blocking model in Figures 6 and 7

(A) Constant pressure filtration of plasma IgG with curves calculated by Equation 30.

(B) Constant pressure filtration of mAb with curve calculated by Equation 31.

Table 5.

Parameters for the numerical calculation of constant pressure filtration of plasma IgG and constant flux filtration of mAb loading to Planova BioEX

Filtration Solution treatment Aggregate ratio, ρ (%) Aggregate particle radius, Rp (nm) Capture limit pore radius, rB (nm) Aggregate particle concentration, c (m−3)
Constant pressure (11 mg/mL plasma IgG) no aggregates addition 0.63 6.7 33 5.43 × 1019
aggregates addition 4.64 12.0 95 7.12 × 1019
high aggregates removal 0.34 6.8 30 2.81 × 1019
less aggregates removal 0.54 11.5 48 9.37 × 1018
Constant flux (10 mg/mL mAb) purified by column flowthrough 0.13 5.9 23 1.53 × 1019

Thus, the filtration behavior of the virus filter can be effectively reproduced by using numerical calculation based on the homogeneous multilayer model with the consideration of pore size distribution for both constant pressure filtration and constant flux filtration.

Heterogeneous multilayer model

The actual virus filters often have an asymmetric structure with different pore size distributions in each layer, and such a structure is expected to significantly affect LRV. Therefore, Shirataki and Wickramasinghe67 developed the homogeneous multilayer model in the previous section and proposed a heterogeneous multilayer model to calculate the LRV and particle retention distribution in the membrane.

In this developed model, the concept of rB and lognormal pore distribution are applied as well as in the previous homogeneous model. Furthermore, it is defined as rB = Rp/F, where F is the deviation of pore shape from circular, where F = 1 for circular pores (0 < F ≦ 1). It is assumed that a heterogeneous multilayer membrane structure consists of M layers, each layer has a different pore size distribution, one layer contains S sheets, and the pore size distributions of sheets in the same layer are the same.

When a solution containing particles permeates through membrane layers with different pore size distributions, the number of particles nm,i introduced into the i-th pore with radius rm,i in the m-th layer (m = 1 to M) is proportional to the total area occupied by pores of rm,i in that layer. Thus, from the total number of particles in volume Δv introduced into the m-th layer at filtration volume v, nm(v) (=∑nm,i = c Δv), the number of particles in Δv introduced into the i-th pore of the m-th layer, nm,i(v), is expressed by the following equation:

nm,i(v)=rm,i2Nm,i(v)∑i=1nrm,i2Nm,i(v)cΔv=rm,i2Nm,i(v)∑i=1nrm,i2Nm,i(v)nm(v) (Equation 32)

Here, Nm,i(v) is the number of pores of radius rm,i in the m-th layer at filtration volume v.

When the pore is small enough to capture particles (i.e., rm,i ≤ rB), the parameters for particle number are defined as follows: nBm,i, number of particles that block one pore of radius rm,i in the m-th layer; nTotalm,i(v), number of particles when particles are trapped in all pores of radius rm,i in the m-th layer at filtration volume v (specifically, nTotalm,i = nBm,i × Nm,i); and nTrapm,i(v), number of particles in volume Δv actually trapped in pores of radius rm,i in the m-th layer at filtration volume v.

Whether a particle introduced into a pore of radius rm,i in one sheet is trapped in that pore may depend on pore size and pore size distribution as well as the movement of the particles. Probability P is introduced to describe the capture of particles, and it is assumed that only Brownian motion of the particles affects P for simplicity of the calculation. When P = 1, particles are always trapped in the pores due to size exclusion; however, when P < 1, some particles are not trapped. It follows that the probability that a particle is not captured in one sheet is 1−P, such that the probability that a particle moves to the next layer without being captured by any sheet in the layer is (1−P)S, where S is the number of sheets in a layer and the probability of a particle being captured in any sheet in the layer is 1−(1−P)S.

Then, nTrapm,i(v), and the change in the number of unblocked pores in the m-th layer from filtration volume v to v + Δv, Nm,i(v + Δv), can be expressed by nm(v) in Equation 32 as follows,

nTrap(v)m,i=rm,i2Nm,i(v)∑i=1nrm,i2Nm,i(v)nm(v)×(1−(1−P)S) (Equation 33)

and

Nm,i(v+Δv)=Nm,i(v)−(RPrm,i)2nTrap(v)m,i (Equation 34)

These equations are combined to give

Nm,i(v+Δv)=Nm,i(v)−(RPrm,i)2rm,i2Nm,i(v)∑i=1nrm,i2Nm,i(v)nm(v)×(1−(1−P)S) (Equation 35)

The total number of particles actually trapped in the m-th layer nTrapm(v) at filtration volume v is given by

nTrap(v)m,i=∑i=1nnTrap(v)m,i=∑i=1BnTrap(v)m,i (Equation 36)

That is, if the pore size distribution of each layer at v = 0 is known, the pore size distribution of each layer after solution permeation at any volume can be obtained. By performing the calculation of Equations 35 and 36 sequentially using spreadsheet software for all layers from m = 1 to m = M, the number of particles trapped in each layer of the multilayer membrane structure after permeation of a solution of known particle concentration through the membrane can be calculated. From these results, the LRV and retention distribution of particles in the membrane after permeation of the solution can be determined.

This model has been applied to experimental results reported by Leisi et al.71 for minute virus of mice (MVM) LRV and retention distribution in the membrane for three different virus filters (A, Planova 20N; B, Pegasus SV4; and C, Viresolve Pro).67

In the calculations, fixed values are defined as RP = 14 nm (radius of MVM), c = 6 × 1015/m3 (experimental data),71 F = 0.3, and M = 50. S is determined from the filter thickness so that the gap between the sheets of each filter is the same. The optimized parameters are mean pore radius for all layers, ra.i (i = 1 to M), and the capture probability, P. By inputting these parameters in Equation 36, the calculation was repeated by optimizing ra.i and P until the calculated retention distribution and LRV reproduced the experimental results. The multilayer structure of the filter, i.e., the pore size distribution of each layer, was determined by this procedure.

Figure 10 shows the calculated ra,i and nTrapm,i together with the experimentally determined MVM capture intensity for the i-th layer in the membrane and the membrane porosity obtained by the experimentally determined membrane material intensity for virus filters A, B, and C. By determining ra,i, the number of pores with radius ri in the m-th layer, Nm,i can be determined from the lognormal distribution of Equation 25. That is, the multilayer structure of the membrane can be determined by optimizing the average pore radius of each layer and can reproduce the MVM capture distribution obtained experimentally as shown in Figure 10.

Figure 10.

Figure 10

Application of the heterogeneous multilayer model to published data indicating porosity distributions, optimized average pore radius, and calculated and experimental MVM capture distributions in the layer

Optimization calculations were performed using Equation 36. (A), filter A; (B), filter B; (C), filter C.

Using the multilayer membrane structure thus determined, the total number of MVM particles captured in the membrane is obtained from the number of particles introduced into each virus filter using Equation 36, and LRV of MVM is determined using the following equation.

LRV=−log(totalnumberofintroducedparticles−totalnumberoftrappedparticlestotalnumberofintroducedparticles) (Equation 37)

Leisi et al.71 also reported the LRV after repeating a 30-min process pause four times in the middle of the filtration for virus filters A, B, and C. The results showed decreased LRV for filtrations with process pauses compared to filtrations without process pause (Table 6). To predict LRV in a filtration with multiple process pauses, calculation was conducted sequentially with Equation 36 so that MVM particles trapped in each layer are released during the process pause and, after the process pause, they are trapped again in the pores of each layer as they are passed through the membrane. Results are summarized in Table 6. The calculated LRV without process pause obtained by optimizing the MVM capture distribution coincides with the experimental results, and the calculated LRV after four process pauses reproduces the experimental results well.67 These results confirm that, by determining the membrane structure of a virus filter based on the multilayer membrane structure model, it is possible to predict the virus LRV both with and without a process pause.

Table 6.

Comparison of experimental and calculated MVM LRV for uninterrupted filtration and filtration with four process pauses

Reported MVM LRV data Calculated MVM LRV results
Filter without process pause 4 × 30 min process pause without process pause 4 × 30 min process pause

A 4.8 2.5 4.81 2.67
B 4.3 1.5 4.32 2.33
C ≥6.0 4.7 6.18 4.95

Equations 30 and 31, which are derived from the homogeneous multilayer structure and represent flux decrease and pressure increase for constant pressure and constant flux filtration, can be extended to the heterogeneous multilayer structure as shown in the following.

J(v)J(0)=∑m=1M1∑i=1nNm,i(0)rm,i4∑m=1M1∑i=1nNm,i(v)rm,i4 (Equation 38)
Δp(v)Δp(0)=∑m=1M1∑i=1nNm,i(v)rm,i4∑m=1M1∑i=1nNm,i(0)rm,i4 (Equation 39)

It suggests that, if the multilayer structure of the virus filter and the size and concentration of aggregates and virus particles contained in the permeating solution are known, it may be possible to reproduce and estimate filtration behavior and virus LRV using the heterogeneous multilayer model.

Concluding remarks

In order to ensure the safety of biopharmaceuticals such as plasma-derived proteins and recombinant proteins, it is an essential to reliably prevent virus contamination in the final preparations. For this purpose, VF is the most robust and reliable method for removing viruses, regardless of solution properties and without damaging target proteins, and, consequently, VF requires extremely strict product design and manufacturing control compared to other membrane categories. Therefore, it is important to understand the function and characteristics of virus filters and how to use them effectively in order to increase the effectiveness of the VF process.

VF is required to have robust virus removability, high target protein recovery, and stable filtration performance. Although the concept of multilayer membrane structure is effective in understanding the features of VF that simultaneously satisfy these requirements, it is not easy to quantitatively reproduce, analyze, and predict the filtration behavior and virus removability of a virus filter. The blocking model, which is effective for analyzing the filtration behavior of MF and UF, cannot take into account the structural characteristics of the virus filter. Furthermore, it cannot be applied to the calculation of virus LRV, which is an important factor for evaluating the effectiveness of the VF step. Although the internal polarization model can effectively reproduce and analyze virus LRV, it cannot be applied to the analysis of filtration behavior.

On the other hand, model calculations based on the generalized blocking model taking the multilayer structure into consideration provide a rational explanation for the negative n value that could not be understood with the classical blocking model. Furthermore, calculation methods that strictly consider the multilayer membrane structure make it possible to reproduce, analyze, and predict filtration behavior and virus LRV. In the future, it is expected that these theoretical filtration models will be further developed, making it possible to reproduce and predict the filtration of protein solutions and virus removal by VF, contributing to the understanding and efficiency of the virus removal process.

Acknowledgments

S.R.W. would like to acknowledge funding from the Fulbright Scholar Program. The authors would like to thank Dr. Daniel Strauss (Asahi Kasei Bioprocess America) for his useful comments on the manuscript.

Author contributions

H.S.: conceptualization, data curation, formal analysis, investigation, writing – original draft, and writing – review and editing. L.G.: writing – original draft and writing – review and editing. S.R.W.: conceptualization, supervision, writing – original draft, and writing – review and editing.

Declaration of interests

H.S. and L.G. are employees of Asahi Kasei Medical Co., Ltd., and Asahi Kasei Bioprocess America, Inc., respectively.

Contributor Information

Hironobu Shirataki, Email: shirataki.hb@om.asahi-kasei.co.jp.

Sumith Ranil Wickramasinghe, Email: swickram@uark.edu.

References

  • 1.Dichtelmüller H.O., Biesert L., Fabbrizzi F., Gajardo R., Gröner A., von Hoegen I., Jorquera J.I., Kempf C., Kreil T.R., Pifat D., et al. Robustness of solvent/detergent treatment of plasma derivatives: a data collection from Plasma Protein Therapeutics Association member companies. Transfusion. 2009;49:1931–1943. doi: 10.1111/j.1537-2995.2009.02222.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Horowitz B., Lazo A., Grossberg H., Page G., Lippin A., Swan G. Virus inactivation by solvent/detergent treatment and the manufacture of SD-plasma. Vox Sang. 1998;74:203–206. doi: 10.1111/j.1423-0410.1998.tb05473.x. [DOI] [PubMed] [Google Scholar]
  • 3.Suomela H. Inactivation of viruses in blood and plasma products. Transfus. Med. Rev. 1993;7:42–57. doi: 10.1016/S0887-7963(93)70032-2. [DOI] [PubMed] [Google Scholar]
  • 4.Korneyeva M., Hotta J., Lebing W., Rosenthal R.S., Franks L., Petteway S.R., Jr. Enveloped virus inactivation by caprylate: a robust alternative to solvent-detergent treatment in plasma derived intermediates. Biologicals. 2002;30:153–162. doi: 10.1006/biol.2002.0334. [DOI] [PubMed] [Google Scholar]
  • 5.Hijnen W.A.M., Beerendonk E.F., Medema G.J. Inactivation credit of UV radiation for viruses, bacteria, protozoan (oo)cysts in water: a review. Water. Res. 2006;40:3–22. doi: 10.1016/j.watres.2005.10.030. [DOI] [PubMed] [Google Scholar]
  • 6.Wigginton K.R., Pecson B.M., Sigstam T., Bosshard F., Kohn T. Virus inactivation mechanisms: impact of disinfectants on virus function and structural integrity. Environ. Sci. Technol. 2012;46:12069–12078. doi: 10.1021/es3029473. [DOI] [PubMed] [Google Scholar]
  • 7.Sadraeian M., Zhang L., Aavani F., Biazar E., Jin D. Viral inactivation by light. eLight. 2022;2:18. doi: 10.1186/s43593-022-00029-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Bolton J.R., Linden K.G. Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments. J. Environ. Eng. 2003;129:209–215. doi: 10.1061/(ASCE)0733-9372(2003)129:3(209). [DOI] [Google Scholar]
  • 9.Tscherne D.M., Jones C.T., Evans M.J., Lindenbach B.D., McKeating J.A., Rice C.M. Time- and temperature-dependent activation of hepatitis C virus for low-pH-triggered entry. J. Virol. 2006;80:1734–1741. doi: 10.1128/JVI.80.4.1734-1741.2006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Roberts P.L., Lloyd D., Marshall P.J. Virus inactivation in a factor VIII/VWF concentrate treated using a solvent/detergent procedure based on polysorbate 20. Biologicals. 2009;37:26–31. doi: 10.1016/j.biologicals.2008.08.003. [DOI] [PubMed] [Google Scholar]
  • 11.Lute S., Norling L., Hanson M., Emery R., Stinson D., Padua K., Blank G., Chen Q., Brorson K. Robustness of virus removal by protein A chromatography is independent of media lifetime. J. Chromatogr. A. 2008;1205:17–25. doi: 10.1016/j.chroma.2008.07.094. [DOI] [PubMed] [Google Scholar]
  • 12.Strauss D.M., Lute S., Tebaykina Z., Frey D.D., Ho C., Blank G.S., Brorson K., Chen Q., Yang B. Understanding the mechanism of virus removal by Q sepharose fast flow chromatography during the purification of CHO-cell derived biotherapeutics. Biotechnol. Bioeng. 2009;104:371–380. doi: 10.1002/bit.22416. [DOI] [PubMed] [Google Scholar]
  • 13.Cai K., Anderson J., Orchard J.D., Afdahl C.D., Dickson M., Li Y. Virus removal robustness of ion exchange chromatography. Biologicals. 2019;58:28–34. doi: 10.1016/j.biologicals.2019.01.004. [DOI] [PubMed] [Google Scholar]
  • 14.Manabe S.I., Kamata Y., Iijima H., Kamide K. Some morphological characteristics of porous polymeric membranes prepared by “micro-phase separation method”. Polym. J. 1987;19:391–404. doi: 10.1295/polymj.19.391. [DOI] [Google Scholar]
  • 15.Manabe S.i., Tsurumi T., Ishikawa G., Satani M., Yamashiki T., Hamamoto Y., Yamaguchi K., Kobayashi S., Yamamoto N. Mechanism of human immunodeficiency virus (HIV) removal by regenerated cellulose hollow fiber (BMM) Membranes. 1989;14:77–83. doi: 10.5360/membrane.14.77. [DOI] [Google Scholar]
  • 16.Brorson K., Sofer G., Aranha H. Nomenclature standardization for ‘large pore size’ virus-retentive filters. PDA J. Pharm. Sci. Technol. 2005;59:341–345. [PubMed] [Google Scholar]
  • 17.van Reis R., Zydney A. Membrane separations in biotechnology. Curr. Opin. Biotechnol. 2001;12:208–211. doi: 10.1016/S0958-1669(00)00201-9. [DOI] [PubMed] [Google Scholar]
  • 18.Wickramasighe S.R., Namila, Fan R., Qian X. In: Current Trends and Future Developments on (Bio-) Membranes. Basile A., Charcosset C., editors. Elsevier; 2019. Chapter 3 - Virus removal and virus purification; pp. 69–96. [DOI] [Google Scholar]
  • 19.Roth N.J., Dichtelmüller H.O., Fabbrizzi F., Flechsig E., Gröner A., Gustafson M., Jorquera J.I., Kreil T.R., Misztela D., Moretti E., et al. Nanofiltration as a robust method contributing to viral safety of plasma-derived therapeutics: 20 years’ experience of the plasma protein manufacturers. Transfusion. 2020;60:2661–2674. doi: 10.1111/trf.16022. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Gröner A., Broumis C., Fang R., Nowak T., Popp B., Schäfer W., Roth N.J. Effective inactivation of a wide range of viruses by pasteurization. Transfusion. 2018;58:41–51. doi: 10.1111/trf.14390. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Horowitz M.S., Rooks C., Horowitz B., Hilgartner M.W. Virus safety of solvent/detergent-treated antihaemophilic factor concentrate. Lancet. 1988;2:186–189. doi: 10.1016/S0140-6736(88)92288-X. [DOI] [PubMed] [Google Scholar]
  • 22.Lemon S.M., Murphy P.C., Smith A., Zou J., Hammon J., Robinson S., Horowitz B. Removal/neutralization of hepatitis A virus during manufacture of high purity, solvent/detergent factor VIII concentrate. J. Med. Virol. 1994;43:44–49. doi: 10.1002/jmv.1890430109. [DOI] [PubMed] [Google Scholar]
  • 23.Hellstern P., Solheim B.G. The Use of Solvent/Detergent Treatment in Pathogen Reduction of Plasma. Transfus. Med. Hemotherapy. 2011;38:65–70. doi: 10.1159/000323552. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Bos O.J., Sunyé D.G., Nieuweboer C.E., van Engelenburg F.A., Schuitemaker H., Over J. Virus validation of pH 4-treated human immunoglobulin produced by the Cohn fractionation process. Biologicals. 1998;26:267–276. doi: 10.1006/biol.1998.0148. [DOI] [PubMed] [Google Scholar]
  • 25.Mpandi M.,, Schmutz P., Legrand E., Duc R., Geinoz J., Henzelin-Nkubana C., Giorgia S., Clerc O., Genoud D., Weber T. Partitioning and inactivation of viruses by the caprylic acid precipitation followed by a terminal pasteurization in the manufacturing process of horse immunoglobulins. Biologicals. 2007;35:335–341. doi: 10.1016/j.biologicals.2007.02.004. [DOI] [PubMed] [Google Scholar]
  • 26.Burnouf-Radosevich M., Appourchaux P., Huart J.J., Burnouf T. Nanofiltration, a new specific virus elimination method applied to high-purity factory IX and factor XI concentrates. Vox Sang. 1994;67:132–138. doi: 10.1111/j.1423-0410.1994.tb01647.x. [DOI] [PubMed] [Google Scholar]
  • 27.Burnouf T., Radosevich M. Nanofiltration of plasma-derived biopharmaceutical products. Haemophilia. 2003;9:24–37. doi: 10.1046/j.1365-2516.2003.00701.x. [DOI] [PubMed] [Google Scholar]
  • 28.Parenteral Drug Association (PDA). (2022). Technical Report No.41 Revised 2022 (TR 41): Virus Retentive Filtration.
  • 29.Inouye M., Burnouf T. The role of nanofiltration in the pathogen safety of biologicals. Curr. Nanosci. 2020;16:413–424. doi: 10.2174/1573413715666190328223130. [DOI] [Google Scholar]
  • 30.Römisch J., Bernhardt D., Diehl K.H., Gröner A., Gröner A., Müller H.G., Müller H.G., Ronneberger H., Schüler E., Schüler E., Römisch J. Nanofiltration bei der Herstellung des PPSB-Konzentrates Beriplex® P/N: Erhöhung der Virus-Eliminierungskapazität unter Beibehaltung der Produktqualität. Hämostaseologie. 1995;15:171–178. doi: 10.1055/s-0038-1655307. [DOI] [Google Scholar]
  • 31.O'Grady J., Losikoff A., Poiley J., Fickett D., Oliver C. Virus removal studies using nanofiltration membranes. Dev. Biol. Stand. 1996;88:319–326. [PubMed] [Google Scholar]
  • 32.Van Holten R.W., Ciavarella D., Oulundsen G., Harmon F., Riester S. Incorporation of an additional viral-clearance step into a human immunoglobulin manufacturing process. Vox Sang. 2002;83:227–233. doi: 10.1046/j.1423-0410.2002.00224.x. [DOI] [PubMed] [Google Scholar]
  • 33.Furuya K., Murai K., Yokoyama T., Maeno H., Takeda Y., Murozuka T., Wakisaka A., Tanifuji M., Tomono T. Implementation of a 20-nm pore-size filter in the plasma-derived factor VIII manufacturing process. Vox Sang. 2006;91:119–125. doi: 10.1111/j.1423-0410.2006.00792.x. [DOI] [PubMed] [Google Scholar]
  • 34.Poelsler G., Berting A., Kindermann J., Spruth M., Hämmerle T., Teschner W., Schwarz H.P., Kreil T.R. A new liquid intravenous immunoglobulin with three dedicated virus reduction steps: virus and prion reduction capacity. Vox Sang. 2008;94:184–192. doi: 10.1111/j.1423-0410.2007.01016.x. [DOI] [PubMed] [Google Scholar]
  • 35.Stucki M., Boschetti N., Schäfer W., Hostettler T., Käsermann F., Nowak T., Gröner A., Kempf C. Investigations of prion and virus safety of a new liquid IVIG product. Biologicals. 2008;36:239–247. doi: 10.1016/j.biologicals.2008.01.004. [DOI] [PubMed] [Google Scholar]
  • 36.Caballero S., Nieto S., Gajardo R., Jorquera J.I. Viral safety characteristics of Flebogamma® DIF, a new pasteurized, solvent-detergent treated and Planova 20 nm nanofiltered intravenous immunoglobulin. Biologicals. 2010;38:486–493. doi: 10.1016/j.biologicals.2010.02.008. [DOI] [PubMed] [Google Scholar]
  • 37.Dichtelmüller H.O., Flechsig E., Sananes F., Kretschmar M., Dougherty C.J. Effective virus inactivation and removal by steps of Biotest Pharmaceuticals IGIV production process. Res. Immunol. 2012;2:19–24. doi: 10.1016/j.rinim.2012.01.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Kee S., Weber D., Popp B., Nowak T., Schäfer W., Gröner A., Roth N.J. Pathogen safety and characterisation of a highly purified human alpha1-proteinase inhibitor preparation. Biologicals. 2017;47:25–32. doi: 10.1016/j.biologicals.2017.03.003. [DOI] [PubMed] [Google Scholar]
  • 39.Roth N.J., Burdick M.D., Cai K., Renfrow H., Buczynski G., Osheroff W., Hotta J., Lee D.,C. Virus and prion safety of a new preparation of human alpha1-proteinase inhibitor, Prolastin®-C. US Respir. Dis. 2011;6:31–39. https://www.semanticscholar.org/paper/Virus-and-Prion-Safety-of-a-New-Preparation-of-1-%C2%AE-Roth-Burdick/219e47b3254bb80bb41c20e8cfc51b1a775ba7db [Google Scholar]
  • 40.Cai K., Osheroff W.P., Buczynski G., Hotta J., Lang J., Elliott E., Lee D.C., Roth N.J. Characterization of Thrombate III®, a pasteurized and nanofiltered therapeutic human antithrombin concentrate. Biologicals. 2014;42:133–138. doi: 10.1016/j.biologicals.2014.01.001. [DOI] [PubMed] [Google Scholar]
  • 41.Oh D.J., Lee Y.L., Kang J.W., Kwon S.Y., Cho N.S., Kim I.S. Evaluation of the virus-elimination efficacy of nanofiltration (Viresolve NFP) for the parvovirus B19 and hepatitis A virus. Korean J. Lab. Med. 2010;30:45–50. doi: 10.3343/kjlm.2010.30.1.45. [DOI] [PubMed] [Google Scholar]
  • 42.Terpstra F.G., Kleijn M., Koenderman A.H.L., Over J., van Engelenburg F.A.C., Schuitemaker H., van 't Wout A.B. Viral safety of C1-inhibitor NF. Biologicals. 2007;35:173–181. doi: 10.1016/j.biologicals.2006.08.005. [DOI] [PubMed] [Google Scholar]
  • 43.Gröner A., Nowak T., Schäfer W. Pathogen safety of human C1 esterase inhibitor concentrate. Transfusion. 2012;52:2104–2112. doi: 10.1111/j.1537-2995.2012.03590.x. [DOI] [PubMed] [Google Scholar]
  • 44.Mazurier C., Poulle M., Samor B., Hilbert L., Chtourou S. In vitro study of a triple-secured von Willebrand factor concentrate. Vox. Sang. 2004;86:100–104. doi: 10.1111/j.0042-9007.2004.00398.x. [DOI] [PubMed] [Google Scholar]
  • 45.Menconi M.C., Maggi F., Zakrzewska K., Salotti V., Giovacchini P., Farina C., Andreoli E., Corcioli F., Bendinelli M., Azzi A. Effectiveness of nanofiltration in removing small non-enveloped viruses from three different plasma-derived products. Transfus. Med. 2009;19:213–217. doi: 10.1111/j.1365-3148.2009.00931.x. [DOI] [PubMed] [Google Scholar]
  • 46.Gröner A. Pathogen safety of Beriate®. Thromb. Res. 2014;134:S10–S15. doi: 10.1016/j.thromres.2013.10.013. [DOI] [PubMed] [Google Scholar]
  • 47.Nowak T., Popp B., Gröner A., Schäfer W., Kalina U., Enssle K., Roth N.J. Pathogen safety of a pasteurized four-factor human prothrombin complex concentrate preparation using serial 20N virus filtration. Transfusion. 2017;57:1184–1191. doi: 10.1111/trf.14010. [DOI] [PubMed] [Google Scholar]
  • 48.ICH. (2023). EMA/CHMP/ICH/804363/2022 Committee for Medicinal Products for Human Use. ICH Q5A(R2) Guideline on viral safety evaluation of biotechnology products derived from cell lines of human or animal origin.https://www.ema.europa.eu/en/documents/scientific-guideline/ich-q5ar2-guideline-viral-safety-evaluation-biotechnology-products-derived-cell-lines-human-or-animal-origin-step-5_en.pdf. (accessed 6 May 2024).
  • 49.Lieber M.M., Benveniste R.E., Livingston D.M., Todaro G.J. Mammalian cells in culture frequently release type C viruses. Science. 1973;182:56–59. doi: 10.1126/science.182.4107.56. [DOI] [PubMed] [Google Scholar]
  • 50.Anderson K.P., Lie Y.S., Low M.A., Williams S.R., Wurm F.M., Dinowitz M. Defective endogenous retrovirus-like sequences and particles of Chinese hamster ovary cells. Dev. Biol. Stand. 1991;75:123–132. [PubMed] [Google Scholar]
  • 51.Barone P.W., Wiebe M.E., Leung J.C., Hussein I.T.M., Keumurian F.J., Bouressa J., Brussel A., Chen D., Chong M., Dehghani H., et al. Viral contamination in biologic manufacture and implications for emerging therapies. Nat. Biotechnol. 2020;38:563–572. doi: 10.1038/s41587-020-0507-2. [DOI] [PubMed] [Google Scholar]
  • 52.Garnick R.L. Experience with viral contamination in cell culture. Dev. Biol. Stand. 1996;88:49–56. [PubMed] [Google Scholar]
  • 53.O’Donnell S., Bolton G. Proceedings of the 2019 Viral Clearance Symposium, Session 6: Virus-retentive filtration. PDA. J. Pharm. Sci. Technol. 2022;76:349–357. doi: 10.5731/pdajpst.2021.012682. [DOI] [PubMed] [Google Scholar]
  • 54.Willkommen H., Blümel J., Brorson K., Chen D., Chen Q., Gröner A., Kreil T.R., Robertson J.S., Ruffing M., Ruiz S. Meeting report—Workshop on virus removal by filtration: trends and new developments. PDA J. Pharm. Sci. Technol. 2013;67:98–104. doi: 10.5731/pdajpst.2013.00907. [DOI] [PubMed] [Google Scholar]
  • 55.Miesegaes G., Bailey M., Willkommen H., Chen Q., Roush D., Blümel J., Brorson K. Proceedings of the 2009 Viral Clearance Symposium. Dev. Biol. 2010;133:3–101. [PubMed] [Google Scholar]
  • 56.Kreil T.R., Roush D. Proceedings of the 2017 Viral Clearance Symposium, Session 2.1: DSP unit operations–virus filtration/inactivation. PDA J. Pharm. Sci. Technol. 2018;72:470–478. doi: 10.5731/pdajpst.2018.009118. [DOI] [PubMed] [Google Scholar]
  • 57.Ide S. Filter made of cuprammonium regenerated cellulose for virus removal: a mini review. Cell. 2022;29:2779–2793. doi: 10.1007/s10570-021-04319-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Dileo A.J., Allegrezza A.E. Validatable virus removal from protein solutions. Nature. 1991;351:420–421. doi: 10.1038/351420a0. [DOI] [PubMed] [Google Scholar]
  • 59.Johnson S.A., Chen S., Bolton G., Chen Q., Lute S., Fisher J., Brorson K. Virus filtration: A review of current and future practices in bioprocessing. Biotechnol. Bioeng. 2022;119:743–761. doi: 10.1002/bit.28017. [DOI] [PubMed] [Google Scholar]
  • 60.Bakhshayeshi M., Zydney A.L. Effect of solution pH on protein transmission and membrane capacity during virus filtration. Biotechnol. Bioeng. 2008;100:108–117. doi: 10.1002/bit.21735. [DOI] [PubMed] [Google Scholar]
  • 61.van Reis R., Zydney A. Bioprocess membrane technology. J. Membr. Sci. 2007;297:16–50. doi: 10.1016/j.memsci.2007.02.045. [DOI] [Google Scholar]
  • 62.Gefroh E., Dehghani H., McClure M., Connell-Crowley L., Vedantham G. Use of MMV as a single worst-case model virus in viral filter validation studies. PDA J. Pharm. Sci. Technol. 2014;68:297–311. doi: 10.5731/pdajpst.2014.00978. [DOI] [PubMed] [Google Scholar]
  • 63.Mattila J., Clark M., Liu S., Pieracci J., Gervais T.R., Wilson E., Galperina O., Li X., Roush D., Zoeller K., et al. Retrospective evaluation of low-pH viral inactivation and viral filtration data from a multiple company collaboration. PDA J. Pharm. Sci. Technol. 2016;70:293–299. doi: 10.5731/pdajpst.2016.006478. [DOI] [PubMed] [Google Scholar]
  • 64.Asahi Kasei Medical Co., Ltd. Asahi Kasei Medical Co., Ltd.; 2023. Planova Filters: Virus Removal for Biotherapeutic Products [Catalog TAE31002-5.0] [Google Scholar]
  • 65.Shirataki H. Analysis of filtration with virus removal filters using the characteristic form of blocking model. Biochem. Eng. J. 2022;183 doi: 10.1016/j.bej.2022.108460. [DOI] [Google Scholar]
  • 66.Shirataki H., Wickramasinghe S.R. Modeling virus filtration based on a multilayer membrane morphology and pore size distribution. Biochem. Eng. J. 2023;194 doi: 10.1016/j.bej.2023.108903. [DOI] [Google Scholar]
  • 67.Shirataki H., Wickramasinghe S.R. Predicting virus filter performance using an advanced membrane structural model. J. Membr. Sci. 2023;685 doi: 10.1016/j.memsci.2023.121929. [DOI] [Google Scholar]
  • 68.Tsurumi T., Osawa N., Hitaka H., Hirasaki T., Yamaguchi K., Manabe S.i., Yamashiki T. Structure of cuprammonium regenerated cellulose hollow fiber (BMM hollow fiber) for virus removal. Polym. J. 1990;22:751–758. doi: 10.1295/polymj.22.751. [DOI] [Google Scholar]
  • 69.Tsurumi T., Sato T., Osawa N., Hitaka H., Hirasaki T., Yamaguchi K., Hamamoto Y., Manabe S.i., Yamashiki T., Yamamoto N. Structure and filtration performance of improved cuprammonium regenerated cellulose hollow fiber (improved BMM hollow fiber) for virus removal. Polym. J. 1990;22:1085–1100. doi: 10.1295/polymj.22.1085. [DOI] [Google Scholar]
  • 70.Manabe S.I., Yamamoto N. A novel virus removal filter and its application. Biomedical Reviews. 1996;6:95–109. doi: 10.14748/bmr.v6.176. [DOI] [Google Scholar]
  • 71.Leisi R., Widmer E., Gooch B., Roth N.J., Ros C. Mechanistic insights into flow-dependent virus retention in different nanofilter membranes. J. Membr. Sci. 2021;636 doi: 10.1016/j.memsci.2021.119548. [DOI] [Google Scholar]
  • 72.Bakhshayeshi M., Jackson N., Kuriyel R., Mehta A., van Reis R., Zydney A.L. Use of confocal scanning laser microscopy to study virus retention during virus filtration. J. Membr. Sci. 2011;379:260–267. doi: 10.1016/j.memsci.2011.05.069. [DOI] [Google Scholar]
  • 73.Kosiol P., Muller M.T., Schneider B., Hansmann B., Thom V., Ulbricht M. Determination of pore size gradients of virus filtration membranes using gold nanoparticles and their relation to fouling with protein containing feed streams. J. Membr. Sci. 2018;548:598–608. doi: 10.1016/j.memsci.2017.11.048. [DOI] [Google Scholar]
  • 74.Fallahianbijan F., Giglia S., Carbrello C., Zydney A.L. Use of fluorescently-labeled nanoparticles to study pore morphology and virus capture in virus filtration membranes. J. Membr. Sci. 2017;536:52–58. doi: 10.1016/j.memsci.2017.04.066. [DOI] [Google Scholar]
  • 75.Leisi R., Rostami I., Laughhunn A., Bieri J., Roth N.J., Widmer E., Ros C. Visualizing protein fouling and its impact on parvovirus retention within distinct filter membrane morphologies. J. Membr. Sci. 2022;659 doi: 10.1016/j.memsci.2022.120791. [DOI] [Google Scholar]
  • 76.Hermans P.H., Bredée H.L. Principles of the mathematic treatment of constant-pressure filtration. J. Soc. Chem. Ind. 1936;55T:1–4. [Google Scholar]
  • 77.Grace H.P. Structure and performance of filter media. II. Performance of filter media in liquid service. AIChE. J. 1956;2:316–336. [Google Scholar]
  • 78.Iritani E. A review on modeling of pore-blocking behaviors of membranes during pressurized membrane filtration. Dry. Technol. 2013;31:146–162. doi: 10.1080/07373937.2012.683123. [DOI] [Google Scholar]
  • 79.Shirato M., Aragaki T., Iritani E. Blocking filtration laws for filtration of power-law non-Newtonian fluids. J. Chem. Eng. Jpn. 1979;12:162–164. [Google Scholar]
  • 80.Iritani E., Mukai Y., Tanaka Y., Murase T. Flux decline behavior in dead-end microfiltration of protein solutions. J. Membr. Sci. 1995;103:181–191. doi: 10.1016/0376-7388(94)00321-O. [DOI] [Google Scholar]
  • 81.Iritani E., Katagiri N., Sugiyama Y., Yagishita K. Analysis of flux decline behaviors in filtration of very dilute suspensions. AIChE J. 2007;53:2275–2283. [Google Scholar]
  • 82.Zydney A.L. Development of a new blocking model for membrane fouling based on a composite media model. J. Membr. Sci. Lett. 2022;2 doi: 10.1016/j.memlet.2022.100018. [DOI] [Google Scholar]
  • 83.Badmington F., Wilkins R., Payne M., Honig E.S. Vmax testing for practical microfiltration train scale-up in biopharmaceutical processing. Pharmaceut. Technol. 1995;19:64–76. [Google Scholar]
  • 84.Bolton G., Siwak M., Ireland T., Lutz H. Viral filtration of plasma-derived human IgG: A case study using Viresolve NFP. Biopharm Int. 2004;17 [Google Scholar]
  • 85.Emami P., Fallahianbijan F., Dinse E., Motevalian S.P., Conde B.C., Reilly K., Zydney A.L. Modified intermediate pore blockage model describes fouling behavior during sterile filtration of glycoconjugate vaccines. J. Membr. Sci. 2020;613 doi: 10.1016/j.memsci.2020.118495. [DOI] [Google Scholar]
  • 86.Ho C.C., Zydney A.L. A combined pore blockage and cake filtration model for protein fouling during microfiltration. J. Colloid Interface Sci. 2000;232:389–399. doi: 10.1006/jcis.2000.7231. [DOI] [PubMed] [Google Scholar]
  • 87.Peles J., Fallahianbijan F., Cacace B., Carbrello C., Giglia S., Zydney A.L. Effect of operating pressure on protein fouling during constant-pressure virus removal filtration. J. Memb. Sci. 2022;648 doi: 10.1016/j.memsci.2022.120351. [DOI] [Google Scholar]
  • 88.Peles J., Cacace B., Carbrello C., Giglia S., Zydney A.L. Protein fouling during constant-flux virus filtration: Mechanisms and modeling. Biotechnol. Bioeng. 2023;120:3357–3367. doi: 10.1002/bit.28511. [DOI] [PubMed] [Google Scholar]
  • 89.Bolton G., LaCasse D., Kuriyel R. Combined models of membrane fouling: Development and application to microfiltration and ultrafiltration of biological fluids. J. Membr. Sci. 2006;277:75–84. doi: 10.1016/j.memsci.2004.12.053. [DOI] [Google Scholar]
  • 90.Bolton G.R., Boesch A.W., Lazzara M.J. The effects of flow rate on membrane capacity: Development and application of adsorptive membrane fouling models. J. Membr. Sci. 2006;279:625–634. doi: 10.1016/j.memsci.2005.12.057. [DOI] [Google Scholar]
  • 91.Hwang K.J., Liao C.Y., Tung K.L. Analysis of particle fouling during microfiltration by use of blocking models. J. Membr. Sci. 2007;287:287–293. doi: 10.1016/j.memsci.2006.11.004. [DOI] [Google Scholar]
  • 92.Tien C., Ramarao B.V. Revisiting the laws of filtration: an assessment of their use in identifying particle retention mechanisms in filtration. J. Membr. Sci. 2011;383:17–25. doi: 10.1016/j.memsci.2011.07.019. [DOI] [Google Scholar]
  • 93.Shirataki H., Yokoyama Y., Oguri R. Effect of mixed-mode and surface-modified column chromatography on virus filtration performance. Biochem. Eng. J. 2021;172 doi: 10.1016/j.bej.2021.108034. [DOI] [Google Scholar]
  • 94.Shirataki H., Yokoyama Y., Taniguchi H., Azeyanagi M. Analysis of filtration behavior using integrated column chromatography followed by virus filtration. Biotechnol. Bioeng. 2021;118:3569–3580. doi: 10.1002/bit.27840. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 95.Jackson N.B., Bakhshayeshi M., Zydney A.L., Mehta A., van Reis R., Kuriyel R. Internal virus polarization model for virus retention by the Ultipor® VF grade DV20 membrane. Biotechnol. Prog. 2014;30:856–863. doi: 10.1002/btpr.1897. [DOI] [PubMed] [Google Scholar]
  • 96.Afzal M.A., Zydney A.L. Effect of filtrate flux and process disruptions on virus retention by a relatively homogeneous virus removal membrane. Biotechnol. Prog. 2022;38:e3255. doi: 10.1002/btpr.3255. [DOI] [PubMed] [Google Scholar]
  • 97.Zydney A.L., Aimar P., Meireles M., Pimbley J.M., Belfort G. Use of the log-normal probability density function to analyze membrane pore size distributions: functional forms and discrepancies. J. Membr. Sci. 1994;91:293–298. doi: 10.1016/0376-7388(94)80090-1. [DOI] [Google Scholar]
  • 98.Wickramasinghe S.R., Bower S.E., Chen Z., Mukherjee A., Husson S.M. Relating the pore size distribution of ultrafiltration membranes to dextran rejection. J. Membr. Sci. 2009;340:1–8. doi: 10.1016/j.memsci.2009.04.056. [DOI] [Google Scholar]

Articles from iScience are provided here courtesy of Elsevier

RESOURCES