Skip to main content
. 2024 Dec 28;13(12):2748–2756. doi: 10.21037/tau-24-451

Table 5. Surgical data of 5 patients who underwent robot-assisted lower tract surgery.

Variables Lower tract surgery (n=5)
Radical prostatectomy (n=4) Radical cystectomy (n=1)
Male 4 [100] 1 [100]
Age (years) 65 (59–75) 70
BMI (kg/m2) 28.4 (21.2–37.4) 28.1
Preoperative prostate-specific antigen level (ng/mL) 18.5 (1.6–41.9) NA
Prostate volume (mL) 34.4 (15.5–78.2) NA
Biopsy Gleason score
   3+4 1 [25] NA
   4+3 2 [50] NA
   4+4 1 [25] NA
Docking time (min) 6.8 (3.0–10.0) 10.0
Operation time (min) 300.3 (183.0–450.0) 374.0
Hemoglobin drop (g/dL) 2.3 (0.6–3.1) 0.2
Hospital stay (days) 13.8 (10.0–17.0) 20.0
Complication cases 1 [25] 0
Follow-up (months) 3 3
Positive margin 1 [25] 0
Pathological T stage
   pT2b 1 [25] NA
   pT2c 3 [75] NA
   pT3 0 1 [100]
Lymphatic metastasis 1 [25] 0
Urinary continence recovery 1 month after catheter removal 0 NA
Preoperative prostate-specific antigen level 3 months after surgery (ng/mL) 0.011 (0.006–0.014) NA

Data are presented as n [%] or mean (range). BMI, body mass index; NA, not applicable.