Skip to main content
. 2024 May 17;13:480. [Version 1] doi: 10.12688/f1000research.145060.1

Table 4. Boundary conditions for TurboMode CFX.

Machine type Centrifugal compressor
Type Steady State
Rotating Axis Z
Speed -40000
Fluid Air Ideal Gas
Reference Pressure 0 atm
Heat Transfer Total Energy
Turbulence Shear Stress Transport
Inflow Pressure 101.325 kPa
Inflow Temperature 288.15 K
Static Pressure 110 kPa
Boundary Type Wall
Wall Influence on flow No Slip Wall