Skip to main content
. 2025 Jan 21;15:2610. doi: 10.1038/s41598-025-86468-z

Table 6.

Validation of developed model. Ql = 25 ml/min, Qg = 70 ml/min, r1 = 1.375 × 10−4 m, r2 = 1.85 × 10−4 m, L = 65 mm. Data was obtained by the research of Rostami et al. 53.

IL mass fraction (%) CO2 molar flux (mol m−2 s−1) (experimental) CO2 molar flux (mol m−2 s−1) (Modeling) Average relative error (%)
0 5.46 × 10−4 5.6 × 10−4 2.5
5 5.52 × 10−4 5.71 × 10−4 3.32
10 5.65 × 10−4 5.90 × 10−4 4.2
15 5.83 × 10−4 6.02 × 10−4 2.57
20 6.07 × 10−4 6.27 × 10−4 4.3
25 6.19 × 10−4 6.4 × 10−4 3.28