Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2024 Jun 23;14(3):2400622. doi: 10.1002/adhm.202400622

Integrated Antigenic and Nucleic Acid Detection in Single Virions and Extracellular Vesicles with Viral Content

Kim Truc Nguyen 1, Xilal Y Rima 1,2, Luong T H Nguyen 1, Xinyu Wang 1, Kwang Joo Kwak 3, Min Jin Yoon 1, Hong Li 1, Chi‐Ling Chiang 1, Jacob Doon‐Ralls 1, Kelsey Scherler 4, Shannon Fallen 4, Stephanie L Godfrey 5, Julie A Wallick 5, Setty M Magaña 6, Andre F Palmer 1, Inyoul Lee 4, Christopher C Nunn 5, Kimberly M Reeves 7, Henry G Kaplan 7, Jason D Goldman 5,8, James R Heath 4, Kai Wang 4, Preeti Pancholi 9, L James Lee 1, Eduardo Reátegui 1,10,✉
PMCID: PMC11773111  PMID: 38820600

Abstract

Virion‐mediated outbreaks are imminent and despite rapid responses, continue to cause adverse symptoms and death. Therefore, tunable, sensitive, high‐throughput assays are needed to help diagnose future virion‐mediated outbreaks. Herein, it is developed a tunable in situ assay to selectively enrich virions and extracellular vesicles (EVs) and simultaneously detect antigens and nucleic acids at a single‐particle resolution. The Biochip Antigen and RNA Assay (BARA) enhanced sensitivities compared to quantitative reverse‐transcription polymerase chain reaction (qRT‐PCR), enabling the detection of virions in asymptomatic patients, genetic mutations in single virions, and enabling the continued long‐term expression of viral RNA in the EV‐enriched subpopulation in the plasma of patients with post‐acute sequelae of the coronavirus disease of 2019 (COVID‐19). BARA revealed highly accurate diagnoses of COVID‐19 by simultaneously detecting the spike glycoprotein and nucleocapsid‐encoding RNA in saliva and nasopharyngeal swab samples. Altogether, the single‐particle detection of antigens and viral RNA provides a tunable framework for the diagnosis, monitoring, and mutation screening of current and future outbreaks.

Keywords: COVID‐19, multiparametric; SARS‐CoV‐2; single extracellular vesicle; single virion


The Biochip Antigen and RNA Assay (BARA) enables simultaneous antigenic and nucleic acid detection of virions and EVs with viral content at a single‐particle resolution. BARA provides unprecedented perspectives on viral diseases, including enhanced sensitivity without amplification, colocalization of biomolecules on intact virions and EVs, accurate diagnoses, and assay adaptability.

graphic file with name ADHM-14-0-g004.jpg

1. Introduction

The emergence of infectious diseases is rising and dominated by zoonoses,[ 1 ] which are the transmission of pathogens from animals to humans.[ 2 ] Zoonoses have been responsible for pandemics, epidemics, and endemics that have plagued the human experience[ 3 ] and that continue to disrupt the social fabric at an individual level, such as inducing psychological distress, or at the societal level, such as burdening the economy.[ 4 , 5 , 6 , 7 ] The coronavirus disease of 2019 (COVID‐19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) is no exception, resulting in the reported infection of 775 million people and deaths of 7 million worldwide to date.[ 8 ] With the number of zoonoses expected to increase due to global warming, human land use, urbanization, and global travel,[ 9 , 10 , 11 ] rapidly tunable and highly sensitive assays are necessary to mitigate future outbreaks via containment measures. Nucleic acid‐based and antigen‐based technologies are currently the gold standard in rapid diagnostics.[ 12 ] While highly sensitive, nucleic acid‐based technologies are limited at detecting low‐virion counts without amplification, and antigen‐based technologies typically require post‐acute immune responses.[ 12 , 13 , 14 , 15 , 16 ] Quantitative reverse‐transcriptase polymerase chain reaction (qRT‐PCR), a nucleic acid amplification assay, was the primary diagnostic utilized to reduce the transmission of the SARS‐CoV‐2 virion despite its false‐negative results and requirement for laboratory equipment and amplification reagents.[ 17 , 18 ] On the other hand, rapid‐antigen tests that target intrinsic virion proteins without amplification granted accessibility to facile COVID‐19 testing for the general public, but are less sensitive than qRT‐PCR.[ 19 ] Therefore, rapidly adaptable technologies that do not require amplification, yet provide highly sensitive and specific diagnostic results are necessary for current and future outbreaks.

Rapid‐antigen tests and qRT‐PCR are bulk‐analysis diagnostics and require the lysis of virions.[ 20 ] Bulk‐analysis diagnostics are thus subject to the dilution of biomolecules within the vast biomolecular landscape of the biofluid,[ 21 ] leading to reduced sensitivities. Furthermore, residual viral biomolecules are detectable by bulk‐analysis methods despite the absence of viral replication,[ 22 ] leading to false‐positive results for an extended time after infection. Mapping biomolecular expression to single intact virions can avert these shortcomings,[ 23 ] reducing false‐positive results and the requirement for amplification. Novel single‐virion technologies have emerged as a response to enhance sensitivities, specificities, assay time, and simplicity.[ 24 , 25 , 26 , 27 ] Label‐free technologies can detect intact single virions through various approaches, including changes in electrical conductivity,[ 28 ] destructive interferences to reflective intensities,[ 29 ] and diffracting surface plasmon waves.[ 30 ] Label‐free technologies, such as the interferometric defocus‐enhanced mid‐infrared photothermal microscope, can further provide chemical spectra capable of differentiating RNA and DNA virions.[ 31 ] On the other hand, fluorescent probes targeting viral biomolecules accelerated assay times via fluorescence microscopy with fluorescent in situ hybridization (FISH),[ 24 ] or via automatic labeling, detection, and analysis with deep learning and novel labeling techniques.[ 26 ] However, the simultaneous robust detection of antigens and nucleic acids in single intact virions to further improve detection limits is yet to be realized.

Virions are biogenetically and morphologically similar to extracellular vesicles (EVs)[ 32 ] which are cell‐derived lipid nanoparticles containing bioactive molecules.[ 33 ] The advent of research in EVs has sought to characterize biomolecular signatures to unravel their vast heterogeneity,[ 34 ] which has promoted the engineering of in situ single‐EV technologies.[ 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 ] Coupling in situ labeling with high‐resolution microscopy, such as total internal reflection fluorescence microscopy (TIRFM), enabled the dual detection of proteins and nucleic acids in single EVs,[ 44 ] resolving intervesicular, intravesicular, and interparticle heterogeneity through subpopulation‐based sorting and colocalization analyses.[ 45 ] TIRFM has been utilized to investigate single‐virion dynamics upon entry or release from the plasma membrane.[ 46 , 47 , 48 ] Therefore, the translation of single‐EV technologies to single virions seems a natural transition to screen for both the presence of virions and EVs with viral content. Combining TIRFM and single‐EV labeling techniques may provide a unique perspective into single‐virion biomolecular signatures via the colocalization of antigenic and nucleic acid detection.

Herein we present the Biochip Antigen and RNA Assay (BARA), which enriches single virions and EVs with viral content from complex biofluids via positive immunoselection and infection mechanisms. BARA combines immunofluorescence (IF) and FISH with TIRFM providing high‐resolution qualitative and quantitative antigenic and nucleic acid expression of single virions and EVs with viral content. BARA was validated with the SARS‐CoV‐2 virion following the guidelines for Emergency Use Authorization (EUA) regulated by the United States Food and Drug Administration (FDA). By progressing toward single‐particle detection, BARA outperformed qRT‐PCR by one order of magnitude, which upon combining antigenic and nucleic acid detection, yielded sensitivities of 100% and 95% and specificities of 100% and 100% in COVID‐19 diagnosis for saliva and nasopharyngeal swab (NS) samples, respectively. Furthermore, BARA revealed the continued long‐term expression of viral RNA in the EV‐enriched subpopulation in the plasma of patients with post‐acute sequelae of COVID‐19 (PASC). The success of the work provides a tunable framework to interrogate single virions, and long‐term infections via the simultaneous detection of biomolecules in EV‐enriched subpopulations in plasma at the single‐particle level. Furthermore, BARA can be easily adapted beyond SARS‐CoV‐2 by customizing the antibodies and proteins for immunoselection and the probes for viral detection.

2. Results

2.1. Simultaneous Detection of Biomolecules on Intact Single Virions and EVs with Viral Content

BARA is a high‐throughput assay that multiplexes signals from antigens and nucleic acids utilizing IF and FISH on single virions and EVs with viral content derived from complex biofluids, such as blood plasma, saliva, and NS. Briefly, glass is coated with gold via a titanium intermediate, providing a plasmonic surface to enhance fluorescent signals emitted by TIRFM. The gold surface is reacted with thiol‐poly(ethylene glycol)‐biotin enabling the subsequent functionalization of NeutrAvidin (NA) and biotinylated antibodies and proteins targeting external epitopes of single virions and EVs. Lastly, fluorescent‐dye‐conjugated antibodies were utilized to perform IF, and molecular beacons were utilized to perform FISH (Figure  1a). TIRFM provides an evanescent wavefront that exponentially decreases from the coverslip surface, affording the visualization of biomolecules in single virions and EVs with viral content as localized fluorescent signals that can be quantified as functions of fluorescent emissions (Figure 1b). The fluorescent signals can be measured at a single‐particle resolution or summed to provide total or relative fluorescence intensities of the virions and EVs in a sample. As a model system, we chose SARS‐CoV‐2 virions for the validation of BARA. While we acknowledge the presence of EV co‐isolates in preparations from virulent culture,[ 32 ] SARS‐CoV‐2 virion‐enriched preparations are hereafter referred to as SARS‐CoV‐2 virions for convenience. Furthermore, transmission electron microscopy (TEM) revealed the presence of spike glycoproteins forming the corona that is a hallmark of coronaviruses (Figure 1c). Therefore, targeting the spike glycoprotein along with multiple regions of the nucleocapsid‐encoding RNA via combining IF and FISH provided the colocalization of fluorescent signals, providing evidence for the co‐expression of biomolecules on a single virion (Figure 1d). While SARS‐CoV‐2 is the model system for validation, the tunable nature of BARA is illustrated by simultaneously targeting antigens and nucleic acids for Influenza A (Figure 1e) and the respiratory syncytial virus (RSV; Figure 1f). Altogether, BARA provides a tunable platform to multiplex antigenic and nucleic acid signals in single virions and EVs with viral content.

Figure 1.

Figure 1

Single virion antigenic and nucleic acid detection with the Biochip Antigen and RNA Assay (BARA). (a) BARA assembly and schematic mechanism for detecting antigens and nucleic acids utilizing immunofluorescence (IF) and fluorescent in situ hybridization (FISH), respectively. Detection is performed on single virions and extracellular vesicles (EVs) with viral content derived from complex biofluids, such as blood plasma, saliva, and nasopharyngeal swabs (NS). (b) Representative total internal reflection fluorescence microscopy (TIRFM) images illustrating the spike glycoprotein on single virions and nucleocapsid‐encoding RNA in single virions, and EVs with viral content, accompanied by their corresponding fluorescence intensity histograms. (c) Transmission electron microscope (TEM) image of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) virions showcasing the visible spike glycoprotein forming corona. (d) Representative TIRFM images demonstrating SARS‐CoV‐2 antigens and RNA on a single SARS‐CoV‐2 virion and the combination of detection methods revealing the colocalization of fluorescent signals in a localized domain. (e) Representative TIRFM images displaying the colocalization of antigens and nucleic acids for Influenza A. (f) Representative TIRFM images showing the colocalization of antigens and nucleic acids for respiratory syncytial virus (RSV).

2.2. Specific and Sensitive Detection of Single SARS‐CoV‐2 Virions

To isolate single SARS‐CoV‐2 virions onto the plasmonic surface of BARA, we tested different methods for immunopositive selection, including antibodies targeting the S1 and S2 subunits of the spike glycoprotein and the coronavirus membrane protein. On the other hand, positive selection was also performed by simulating the port of entry for cellular infection[ 49 , 50 ] with recombinant angiotensin‐converting enzyme 2 (ACE2). Optimizing the surface for the capture of single virions demonstrated that targeting the spike glycoprotein via antibodies or recombinant ACE2 provided the highest relative fluorescence intensity for IF of the spike glycoprotein (Figure S1a, Table S1). Relative fluorescence intensity was defined as the sum of fluorescence intensity signals of the sample normalized by that of the negative control (phosphate‐buffered saline, PBS).[ 44 , 45 ] Scanning electron microscopy demonstrated the capture of single SARS‐CoV‐2 virions within the ACE2‐functionalized surface of BARA (Figure S1b). Flow cytometry was performed for spike glycoprotein detection of SARS‐CoV‐2, murine leukemia virus (MLV), and PBS to cross‐validate the IF of the spike glycoprotein with BARA, revealing a fluorescent enrichment for the sample only (Figure S2a). For nucleic acid detection, specificity was also tested with flow cytometry by targeting three regions of the nucleocapsid‐encoding RNA on SARS‐CoV‐2, MLV, and PBS. The molecular beacons hybridized at higher rates for the SARS‐CoV‐2 samples, whereas MLV and PBS yielded similarly low levels of fluorescent signal (Figure S2b). Quantifying the fluorescence data revealed higher fluorescence intensities for SARS‐CoV‐2 virions, whereas MLV and PBS had minimal intensities for both IF and FISH (Figure S2c). Having detection methods for antigens and nucleic acids in SARS‐CoV‐2 virions, we tested the ability to colocalize signals by combining detection methods in single virions. Therefore, we utilized BARA while co‐targeting the spike glycoprotein and nucleocapsid‐encoding RNA via in situ TIRFM image acquisition. Colocalized signals were observed that could be investigated multi‐dimensionally. Apart from measuring fluorescence intensity one‐dimensionally as total or relative fluorescence intensities, herein we demonstrate the spatial expression of the spike glycoprotein and nucleocapsid‐encoding RNA on a single SARS‐CoV‐2 virion by measuring fluorescence intensity as a function of the x – y plane (Figure S3a). Furthermore, cross‐sections of the three‐dimensional expression provide a two‐dimensional fluorescence intensity profile as a function of an axis, revealing more spatially variable and diffuse expression of the spike glycoprotein compared to the nucleocapsid‐encoding RNA (Figure S3a).

To demonstrate an ability to distinguish antigenic and nucleic acid signals in single SARS‐CoV‐2 virions from negative controls, we aimed to characterize the sensitivities of BARA. Therefore, we compared BARA utilizing the top candidates for virion capture to the most sensitive COVID‐19 diagnostic assay, qRT‐PCR. Targeting the S1 and S2 subunits of the spike glycoprotein exhibited a linear range of 103–106 particles/well (R2 = 0.99; ANOVA, p = 0.0023), whereas utilizing recombinant ACE2 to immobilize the single virions lent a linear range of 102–106 particles/well (R2 = 0.98; ANOVA, p = 0.0008) when detecting the spike glycoprotein (Figures 2a, S3b). Similarly, detecting nucleocapsid‐encoding RNA when immobilizing with recombinant ACE2 demonstrated a linear range of 102–106 particles/well (R2 = 0.97; ANOVA, p = 0.0152). Therefore, both SARS‐CoV‐2 antigenic and nucleic acid detection via ACE2‐mediated immobilization outperformed qRT‐PCR by an order of magnitude, which became undetectable at 102 particles/well (Figure 2a). To further demonstrate the ability of BARA to detect at the limit of detection (LoD), ACE2‐mediated immobilization was coupled with both spike glycoprotein and nucleocapsid‐encoding RNA to detect SARS‐CoV‐2 virions spiked into the healthy donor saliva at 102 particles/well. Compared to healthy donor saliva, which had a similar signal to PBS (Dunnet's test, p = 0.9813), the single SARS‐CoV‐2 virions at the LoD demonstrated a significantly higher signal for spike glycoprotein detection (Figure 2b; Welch's two‐tailed t‐test, p < 0.0001). Furthermore, detection of the nucleocapsid‐encoding RNA at the LoD further demonstrated significantly higher total fluorescence intensities than healthy saliva (Figure 2b; Welch's two‐tailed t‐test, p < 0.0001). Next, we tested whether freezing saliva affected the ability to detect the spike glycoprotein with BARA. Therefore, SARS‐CoV‐2 virions were spiked at varying dilutions into saliva and tested immediately or frozen then rethawed. While there was an effect of freezing on the detection of various dilutions, such as a reduction in the slope (ANOVA, p < 0.0001 for the interaction effect), BARA could discern the dilutions linearly for both frozen and fresh saliva samples (Figure 2c‐d; ANOVA, p = 0.0090 for frozen saliva and p = 0.0003 for fresh saliva). To further show the utility of BARA as an automated high‐throughput diagnostic assay, four BARA assays can be assembled in parallel alongside an automated pipetting machine for the facile testing of 256 samples. Various dilutions of SARS‐CoV‐2 virions were introduced, allowing for the testing of 256 samples at different LoD simultaneously (Figure 2e). Utilizing the high‐throughput technique, each sample corresponded with a total fluorescence intensity (Figure 2f), which could be translated to SARS‐CoV‐2 positivity via higher total fluorescence intensities than that of the LoD (Figure 2g). With this cutoff, BARA yielded a positive percentage agreement (PPA) of 100% and a negative percentage agreement (NPA) of 100% (Figure 2g).

Figure 2.

Figure 2

Performance evaluation of BARA. (a) Comparative evaluation of antigenic (with angiotensin‐converting enzyme 2 (ACE2)‐mediated capture and anti‐S1/S2‐mediated capture) and nucleic acid signals from BARA in comparison to standard qRT‐PCR. SARS‐CoV‐2 virions were spiked in phosphate‐buffered saline (PBS) at concentrations ranging from 0 to 1 × 106 particles/well (n = 3, error bars indicate the standard deviation). (b) Detection results at the limit of detection (LoD) of BARA (n = 20 for LoD, n = 4 for pooled healthy donor saliva), demonstrating 20/20 detectable results for the antigen test and 19/20 detectable results for the RNA test. (c) Stability analysis of BARA with frozen saliva specimens spiked at different LoDs (n = 69 with at least 10 replicates for 1–2 × LoD, 3–5 × LoD, and pooled healthy donor saliva conditions). (d) Stability analysis of BARA with fresh saliva specimens spiked at different LoDs (n = 58 with at least 10 replicates for 1–2 × LoD, 3–5 × LoD, and pooled healthy donor saliva conditions). (e) Schematic representation of the high‐throughput, automatic assay realized by BARA, demonstrating the use of 4 BARA in parallel on a plate holder and an automated pipetting machine for simultaneous testing of 256 samples. (f) Assessment of total fluorescence intensity of individual samples at various SARS‐CoV‐2 virion concentrations, ranging from 0 to 5 × LoD. (g) Interpretation of negative and positive samples after applying the cut‐off value, resulting in a positive percentage agreement (PPA) of 100% and a negative percentage agreement (NPA) of 100%.

To prove specificity, we tested three times the LoD of SARS‐CoV‐2 virions for antigenic and nucleic acid detection with BARA in the presence of multiple respiratory pathogens (Table S2). While the respiratory pathogens affected the fluorescent signal (ANOVA, p < 0.0001 for the interaction effect for both antigenic and nucleic acid detection), BARA accurately discriminated between samples spiked with the SARS‐CoV‐2 virions and the corresponding control (Figure 3a; ANOVA, p < 0.0001 for the effect of spiking for both antigenic and nucleic acid detection). Furthermore, three times the LoD in the presence of various endogenous and exogenous substances used for curing or lessening symptoms associated with SARS‐CoV‐2 infections was tested with BARA (Table S3). Despite the endogenous and exogenous substance utilized affecting the fluorescence intensity (ANOVA, p < 0.0001 for the interaction effect for both antigenic and nucleic acid detection), BARA distinguished the spiked samples from the control in the presence of endogenous and exogenous substances (Figure 3b; ANOVA, p < 0.0001 for the effect of spiking for both antigenic and nucleic acid detection). Lastly, to test the ability to disseminate BARA, accelerated stability was performed according to the Clinical and Laboratory Standards Institute (CLSI) EP25‐A to evaluate the stability of in vitro diagnostic reagents (Table S4‐5). The entire assay, including the biochip and the reagents therein, were incubated and tested at various temperatures and time points to determine the efficiency of detecting the spike glycoprotein on single SARS‐CoV‐2 virions (Figure S4a). Utilizing the Arrhenius equation, various rate constants for each temperature were extracted from which the rate of degradation at 4 °C was extrapolated (Figure S4b‐c), revealing a 10% degradation of BARA at 94.26 days when stored at 4 °C. Therefore, BARA holds diagnostic promise as an automated high‐throughput clinically relevant assay for simultaneously detecting antigens and nucleic acids in single SARS‐CoV‐2 virions with sensitivities higher than qRT‐PCR.

Figure 3.

Figure 3

Cross‐reactivity, microbial interference, and endogenous/exogenous substances interference. (a) Heatmap of antigen and nucleocapsid‐encoding RNA signals during the evaluation of various respiratory pathogens, including 14 viruses, 15 bacteria, and 1 fungus at various concentrations (Table S2), in the presence of 0 and 3 × LoD of SARS‐CoV‐2 virions with antigenic and nucleic acid detection for three replicates. (b) Heatmap of spike glycoprotein and nucleocapsid‐encoding RNA signals during the evaluation of various endogenous/exogenous substances, including 16 substances and 3 common antiviral and antibacterial medicines, spiked into pooled healthy saliva at different concentrations (Table S3), in the presence of 0 and 3 × LoD of SARS‐CoV‐2 virions with antigenic and nucleic acid detection for three replicates.

2.3. Monitoring Genetic Mutations on Single Virions

Given that SARS‐CoV‐2 variants alter the structure of the spike glycoprotein to evade immune responses,[ 51 ] we tested the ability of BARA to detect the spike glycoprotein on the various variants experienced throughout the pandemic in the USA, including the original Washington strain (USA‐WA1/2020), alpha, beta, gamma, delta, and omicron strains. Irrespective of the mutations, positive signals for the spike glycoprotein were obtained for all strains (Figure 4a), which were significantly higher than the negative control of PBS (Figure S5a; Dunnett's test, p ≤ 0.0162). Since variants arise from mutations in the viral genome, we tested whether the enhanced sensitivity of BARA would be sufficient to detect genetic mutations at a single‐virion resolution. Therefore, we designed molecular beacons to co‐target S2‐encoding RNA and variant‐specific mutations for delta and omicron variants emitting different wavelengths upon TIRFM excitation. First, we determined whether BARA could discern the ΔF157 and L452R mutations present in the delta variant from the Washington strain. The ΔF157 mutations revealed signal enrichment for the delta variant as opposed to the original Washington strain (Tukey's HSD, p = 0.0045). However, the Washington strain emitted a higher total fluorescence intensity than the control (Figure S5a; Tukey's HSD, p = 0.0018). On the other hand, the L452R mutation was overexpressed in the delta strain as opposed to the original Washington strain (Tukey's HSD, p = 0.0106) and was absent for the Washington strain (Figure S5a; Tukey's HSD, p = 0.3309). For the delta variant, BARA colocalized signals for the spike glycoprotein, S2‐encoding RNA, and the L452R mutation whereby the colocalization of fluorescent signals as the primary colors of light added to white light, demonstrating the co‐expression of the biomolecules on a single virion (Figure 4b). Similarly, BARA colocalized signals for the spike glycoprotein, S2‐encoding RNA, and the ΔH69 mutation on single virions (Figure 4b), revealing an enrichment in the omicron variant when compared to the original Washington strain (Figure S5b; Tukey's HSD, p = 0.0018), albeit detectable in the original Washington strain (Tukey's HSD, p = 0.0085). While BARA distinguished positive signals for the different variants, to further determine the robustness of spike glycoprotein detection, multiple Pango lineages of the omicron variant were tested, including BA.5.1, BF.7, BQ.1, XBB.1.5, BA.2.12.1, and BA.2.3. Positive signals were observed for the Pango lineages (Figure 4c) and were significantly higher than the negative control for BA.2.12.1, BA.5.1, and XBB.1.5 (Figure S5b; Dunnett's test, p ≤ 0.0487).

Figure 4.

Figure 4

Lineage and mutation monitoring with BARA. (a) Representative images of various SARS‐CoV‐2 variants, including the original Washington strain (USA‐WA1/2020), alpha (B.1.1.7), beta (B.1.351), gamma (P.1), delta (B.1.617.2), omicron (BA.1) variants. Inset histograms illustrate the expression distributions of single virions as distributions of fluorescence intensity. (b) Representative image of colocalized signals for spike glycoprotein, S2‐encoding RNA, and the L452R mutation in a single virion of the delta variant. Additionally, colocalized signals for the spike glycoprotein, S2‐encoding RNA, and the ΔH69 single point mutation in a virion of the omicron variant. (c) Variant monitoring by detecting various Pango lineages of the omicron variant using BARA for spike glycoprotein detection, including BA.5.1, BF.7, BQ.1, XBB.1.5, BA.2.12.1, and BA.2.3. Inset histograms illustrate the expression distributions of single virions as distributions of fluorescence intensity.

2.4. Dual Antigenic and Nucleic Acid Detection for COVID‐19 Diagnosis

To test the clinical potential of BARA for detecting virion‐mediated infections, we validated ACE2‐mediated capture for distinguishing patients with COVID‐19 utilizing complex biofluid samples, including saliva (n = 33 patients, n = 30 healthy donors) and NS (n = 40 patients, n = 19 healthy donors). Based on clinical testing, patient specimens were collected from PCR‐confirmed COVID‐19 cases (Table S6‐7). Spike glycoprotein and nucleocapsid‐encoding RNA were utilized to determine COVID‐19‐positive patients. Both antigenic and nucleic acid detection demonstrated enhanced signals for patients with COVID‐19 for saliva (Figure 5a; Mann‐Whitney U test, p < 0.0001 for antigenic and nucleic acid detection) and NS (Figure 5a; Mann‐Whitney U test, p < 0.0001 for antigenic detection, p = 0.0002 for nucleic acid detection). Specifically, spike glycoprotein detection in saliva revealed a sensitivity of 94% and a specificity of 100%, whereas nucleocapsid‐encoding RNA detection yielded a sensitivity of 91% and a specificity of 100% (Figure S6a). On the other hand, detection in NS provided sensitivities of 88% and 80% for spike glycoprotein and nucleocapsid‐encoding RNA detection, respectively, and specificities of 100% for both detection methods (Figure S6b). Given that the highest specificity was obtained for spike glycoprotein detection, we tested whether the enhanced sensitivity of the single‐virion method could diagnose the patient subpopulation with asymptomatic COVID‐19.[ 52 , 53 ] Therefore, a cohort of 20 asymptomatic patients was tested with BARA, revealing an enrichment of signals for the asymptomatic cohort compared to healthy donors (Figure 5b; Mann‐Whitney U test, p = 0.0003).

Figure 5.

Figure 5

Clinical validation of BARA using saliva and NS specimens from patients with the coronavirus disease of 2019 (COVID‐19). (a) Antigenic and nucleic acid signals from patients with COVID‐19 are significantly enhanced in comparison to healthy donors (Mann‐Whitney U test, ****p <0.0001, ***p <0.001) in both saliva (n = 33 patients, n = 30 healthy donors) and NS specimens (n = 40 patients, n = 19 healthy donors). (b) Clinical validation of asymptomatic COVID‐19‐positive patient saliva (n = 20 for asymptomatic, n = 6 pooled healthy donor saliva). (c) Correlation between antigenic and nucleic acid expression of saliva specimens, with minimal expression observed in the saliva of healthy donors (Pearson's correlation coefficient, p < 0.0001 for r = 0.76). (d) Receiver operating characteristic (ROC) curves for combined detection of antigens and nucleic acids in saliva with an enhanced area under the curve (AUC) value of 1.00 for dual detection. (e) Correlation analysis of antigenic and nucleic acid expression in NS, revealing a subpopulation of healthy donors with minimal expression of both biomarkers. (f) ROC curve analysis of antigenic, nucleic acid, and the dual biomarker expression in NS specimens, indicating an enhanced AUC value of 0.97.

To further improve the sensitivities of BARA as NS demonstrated lower diagnostic performances, we utilized the ability of BARA to detect both antigenic and nucleic acid signals to provide a combinatorial approach to diagnose COVID‐19 for salivary and nasopharyngeal samples. Antigenic and nucleic acid expression strongly coincided (Pearson's correlation coefficient, p < 0.0001 for r  = 0.76) and had weak negative associations with qRT‐PCR cycle‐threshold values for patients with COVID‐19 (Pearson's correlation coefficient, r = −0.33 for antigenic detection, r = −0.14 for nucleic acid detection), revealing a distinct subpopulation for healthy donors with minimal expression of both biomarkers (Figure 5c). Utilizing receiver operating characteristic (ROC) curves, combined antigenic and nucleic acid detection augmented the area under the curve (AUC) from 0.96 for antigenic detection and 0.98 for nucleic acid detection to 1.00 for dual detection (Figure 5d). Thus, the sensitivity was enhanced to 100% (Figure S6b). Despite the expression of NS samples only weakly associating between antigenic and nucleic acid detection (Pearson's correlation coefficient, r = 0.15) with weak negative correlations with qRT‐PCR cycle‐threshold values for patients with COVID‐19 (Pearson's correlation coefficient, r = −0.29 for antigenic detection, r = −0.44 for nucleic acid detection), a subpopulation of healthy donors with minimal expression of both biomarkers was present with slight intercalations of patients with COVID‐19 (Figure 5e). ROC curves revealed the enhanced diagnostic capability of BARA by utilizing the combinatorial method, increasing the AUC from 0.91 and 0.87 for antigenic and nucleic acid detection, respectively, to 0.97 for dual detection (Figure 5f), which increased the sensitivity to 95% (Figure S6b). Therefore, dual antigenic and nucleic acid detection with BARA enhances sensitivities for a reliable COVID‐19 diagnostic assay.

2.5. Viral RNA Detection in the EV‐enriched Subpopulation of Patients with PASC

Patients with COVID‐19 may suffer a heterogeneous set of symptoms post‐infection, which is referred to as PASC,[ 54 ] ranging from neurologic.[ 55 ] to cardiovascular symptoms,[ 56 ] and affecting various organs.[ 57 ] Therefore, we hypothesized that viral RNA may be present in the plasma‐derived EVs of patients with PASC long after infection. Patients with PASC were recruited as patients with ongoing, relapsing, or new symptoms persisting beyond 30 days of acute infection. Samples from seven patients with PASC were used in the investigation (Table S8‐9), whereby their plasma was collected serially at three time points and co‐detected with qRT‐PCR and BARA. Tunable resistive pulse sensing (TRPS) on the size distribution of salivary particles from healthy donors revealed similar profiles to SARS‐CoV‐2 virions (Figure S7). Virions and EVs share various characteristics and biomolecules, such as tetraspanins.[ 58 ] On the other hand, spectra of virion‐EV intermediates are present during infection with varying expression of EV‐specific and viral biomolecules.[ 32 ] Therefore, we aimed to isolate EVs from SARS‐CoV‐2 virions via subpopulation‐based sorting. The use of an antibody cocktail targeting CD63 and CD9, which are tetraspanins enriched in various subpopulations of EVs,[ 59 ] reduced the comparative signal of spike glycoprotein and enriched the presence of CD63 signals in the saliva of a patient with COVID‐19 (Figure S8). However, capturing with antibodies targeting the S1 and S2 subunits of the spike glycoprotein yielded CD63 signals despite a large reduction (Figure S8), indicating a possible co‐isolation of virions and EVs. A comprehensive analysis of salivary particles revealed that spike glycoprotein detection yielded positive signals for patient samples compared to healthy donors irrespective of anti‐CD63/CD9‐mediated and ACE2‐mediated capture (Figure S9a), further confirming the presence of co‐isolates (Figure S9b; ANOVA, p = 0.0307 for the sample, p = 0.3921 for the method of capture). However, CD63 signals depended on the method of capture irrespective of whether the sample was from a healthy donor or a patient with COVID‐19 (Figure S9b; ANOVA, p < 0.0001 for the method of capture, p = 0.0924 for the sample), where anti‐CD63/CD9‐mediated capture outperformed ACE2‐mediated capture, which had minimal signal (Figure S9a). Therefore, spike glycoprotein signals were positive for both methods of capture in patients with COVID‐19, indicating an inability of BARA to distinguish virions from EVs in active infections. These results coincide with the observed expression of the spike glycoprotein in both virions and EVs during infection.[ 60 ] Furthermore, to retrieve plasma‐derived EVs, we conducted various isolation and pre‐treatment methods, including dextran‐based precipitation, size‐exclusion chromatography, and thrombin pre‐treatment for the cleavage of fibrinogen.[ 61 ] The plasma treated with thrombin produced CD63 and CD81 signals at higher frequencies than the isolation methods (Figure S10a‐b). Moreover, thrombin pre‐treatment exhibited less loss of EVs than the isolation protocols (Figure S10c). Similar to our analysis of salivary samples, anti‐CD63/CD9‐mediated capture of plasma samples enhanced the CD63 signals compared to ACE2‐mediated capture, which again had minimal signal (ANOVA, p = 0.0050 for the method of capture). Furthermore, patients exhibited more CD63 signals despite a lack of interaction between the method of capture and sample type (Figure S11a‐b; ANOVA, p = 0.0388 for the sample, p = 0.0629 for the interaction effect). Lastly, spike glycoprotein detection in plasma revealed minimal signal (Figure S11a), despite a small yet significant loss of signal for patient samples irrespective of the method of capture (Figure S11b; ANOVA, p = 0.007 for the sample, p = 0.1170 for the method of capture). Altogether, the results suggest an inability for ACE2‐mediated capture to immobilize plasma‐derived particles onto the plasmonic surface, suggesting an absence of virions in the plasma of patients with PASC. Moreover, anti‐CD63/CD9‐mediated capture yielded minimal signals for the spike glycoprotein, further confirming these findings. Although co‐isolates may exist, the majority of anti‐CD63/CD9‐sorted plasma‐derived particles are enriched with EVs and are hereafter referred to as the EV‐enriched subpopulation.

Therefore, to test the presence of viral RNA in the EV‐enriched subpopulation, thrombin‐treated plasma from patients with PASC was screened with BARA whereby the EV‐enriched subpopulation was isolated via positive immunoselection with CD63/CD9‐targeting antibodies and detected for the nucleocapsid‐encoding RNA. A high‐intensity subpopulation for nucleocapsid‐encoding RNA expression was detected in the EV‐enriched subpopulation at a single‐particle resolution after long timeframes extending past 200 days, which was absent in healthy donor serum, whereas CD63 expression remained the same across healthy donor and PASC samples (Figure 6a). The total expression of CD63 demonstrated that the detection of the EV‐enriched subpopulation was consistent across samples as CD63 signals remained high for healthy donors and patients with PASC (Student's two‐tailed t‐test, p = 0.35), whereas nucleocapsid‐encoding RNA signals were higher for patients with PASC (Figure 6b; Student's two‐tailed t‐test, p = 0.0055). Furthermore, the presence of nucleocapsid‐encoding RNA in the EV‐enriched subpopulation was demonstrated by the colocalization of CD63 and the spike glycoprotein (Figure 6c). Interestingly, colocalization analyses with BARA revealed that the colocalization of nucleocapsid‐encoding RNA in the EV‐enriched subpopulation decreased over time (Figure 6e). Although qRT‐PCR and BARA did not correlate in levels of expression for the nucleocapsid‐encoding RNA in the EV‐enriched subpopulation (Pearson's correlation coefficient, r = 0.08), likely due to qRT‐PCR being at the cusp of its LoD (Table S8), the qRT‐PCR demonstrated positivity whereby BARA provided holistic profiles of the nucleocapsid‐encoding RNA levels as a function of time (Figure 6d). Single‐EV analyses of the plasma‐derived EV‐enriched subpopulation revealed a distinct subpopulation of CD63‐expressing particles with high levels of the nucleocapsid‐encoding RNA, indicating a higher level of RNA expression in the colocalized EV‐enriched subpopulation (Figure S12). Therefore, BARA demonstrated the packaging of viral RNA in the EV‐enriched subpopulation in the plasma of patients with symptoms post‐infection, which might describe residual viral RNA as the culprit for the long‐term symptoms associated with PASC.[ 57 , 62 ]

Figure 6.

Figure 6

Viral RNA detection in the EV‐enriched subpopulation in the plasma of patients with post‐acute sequelae of COVID‐19 (PASC). (a) Comparison of viral RNA content and expression of CD63 in the EV‐enriched subpopulation in the plasma of patients with PASC compared to healthy donor plasma at a single‐particle resolution. (b) Dual detection of CD63 and nucleocapsid‐encoding RNA in the EV‐enriched subpopulation in the plasma of healthy donors and patients with PASC (P02 and P07). (c) Colocalization analysis of CD63 and nucleocapsid‐encoding RNA signals in the EV‐enriched subpopulation at single‐particle resolution. Inset demonstrates CD63‐positive particle containing nucleocapsid‐encoding RNA as highlighted by the white arrows. (d) Detection of nucleocapsid‐encoding RNA in thrombin‐treated plasma of seven patients with PASC (P01 to P07) at 3 serial timelines (T1, T2, and T3). A comparison with thrombin‐treated plasma from donors who fully recovered from COVID‐19 (HD13 and HD13*, indicating a 1‐month duration, HD44) and thrombin‐treated plasma from a healthy donor (HD36), collected in 2019 prior to the COVID‐19 outbreak. (e) The colocalization percentage of CD63 and nucleocapsid‐encoding RNA was monitored in the EV‐enriched subpopulation in plasma at different stages of infection.

3. Discussions

BARA demonstrates the translation of single‐EV technologies for clinical application to detect antigenic and nucleic acid signals in single virions and EVs. Progressing toward single‐EV detection has afforded unprecedented sensitivities surpassing enzyme‐linked immunosorbent assay (ELISA) for protein detection[ 44 ] and qRT‐PCR for microRNA[ 45 ] and messenger RNA detection.[ 44 , 63 ] BARA outperformed qRT‐PCR by detecting the spike glycoprotein and nucleocapsid‐encoding RNA in single SARS‐CoV‐2 virions, demonstrating a clear benefit of single virion detection over bulk‐analysis methods. The enhanced sensitivity allowed for the detection of a subpopulation of patients with COVID‐19 that often eluded qRT‐PCR tests, which were asymptomatic and were partly responsible for the vast undetectable spread of the SARS‐CoV‐2 virion.[ 64 , 65 , 66 ] Another subpopulation of patients with COVID‐19 that were partly responsible for the spread of the disease was recently infected individuals who often presented false‐negative results.[ 67 , 68 , 69 ] Detecting patients upon infection prior to contagion is a diagnostic window to limit the spread of virion‐mediated outbreaks by enforcing a bottleneck to virion transmission, such as is observed for highly mortal pathogenic diseases like Ebola.[ 70 ] Furthermore, the ability to colocalize signals and enrich virions and EVs with viral content afforded by BARA enables the mapping of biomolecular signals to intact particles, which is not possible through bulk‐analysis methods and produces false‐positive signals past symptom recovery. Therefore, single‐virion methods may aid in the rapid detection and subsequent mitigation of outbreaks via efficiently detecting patients with low‐virion counts and delineating biomolecular signals to intact virions.

Another benefit to utilizing single‐particle methods is the facile deconvolution of vesicular heterogeneity via in situ colocalization of biomolecular signals.[ 40 , 71 ] BARA offered a unique qualitative perspective through the colocalization of biomolecular signals, allowing the visualization of mutation‐harboring virions and viral RNA within the EV‐enriched subpopulation in the plasma of patients with PASC. Due to the growing risk of zoonoses, an active field in emerging infective diseases is the identification of mutations that may lead to animal‐to‐human transmission or vice versa.[ 72 ] BARA can aid in identifying documented human‐infecting mutations with a housekeeping gene in animals that pose a threat to interspecies spillover via colocalization analyses as an alternative to qRT‐PCR. On the other hand, with BARA we determined that patients with PASC harbor viral RNA in EV‐enriched subpopulations after extended timeframes. Given the heterogeneous symptoms experienced by patients with PASC,[ 73 , 74 , 75 ] colocalizing organ‐specific biomarkers with EV biomarkers and viral RNA may elucidate the causations of symptoms or even predict symptoms before their onset. Moreover, antibodies can be screened in high throughput via IF on various virion strains to possibly determine the efficacy of vaccine targets. The avenues for BARA open various investigative opportunities, many of which are currently being explored.

Lastly, the tunability of BARA provides a customizable framework for many virion‐mediated diseases. Although the investigation focused on detecting single SARS‐CoV‐2 virions to demonstrate the diagnostic capabilities of BARA, selecting antibody or recombinant protein cocktails corresponding to external epitopes of virions can be rapidly achieved. Herein, we demonstrated the ability of BARA to detect antigens and nucleic acids simultaneously in single Influenza A and RSV virions by further designing molecular beacons and fluorescent‐dye‐conjugated antibodies tailored to their respective biomolecules. Apart from providing the unique multifaceted detection of single virions, the combination of IF and FISH for detecting antigens and nucleic acids in single virions enhanced the sensitivity of BARA compared to single biomolecule detection. The increased sensitivities afforded the detection of single SARS‐CoV‐2 virions in complex biofluids and the sensitive identification of patients with COVID‐19 insofar as sensitivities of 100% in the case of saliva were observed. BARA provides a highly sensitive diagnostic assay that can be easily tuned to future outbreaks and provides a perspective into the pathophysiology of virion‐mediated diseases, realizing a comprehensive assay unmet by current diagnostics.

4. Experimental Section

BARA Fabrication

High‐precision, 24 × 75 × 0.15 mm, borosilicate glass coverslips (D 263 M; Schott AG, Mainz, Germany) were cleaned with ethanol followed by deionized (DI) water in an ultrasonic bath for 5 min each. After repeating the cleaning process, the coverslips were dried with nitrogen gas. The coverslips were cleaned with a UV‐ozone cleaner (Jelight, Irvine, CA) for 15 min. A 2‐nm film of titanium was first deposited onto the cleaned coverslips via electron beam evaporation (DV‐502A; Denton Vacuum, Moorestown, NJ) to facilitate the adhesion of gold to the surface. Utilizing the same technique, a 10‐nm film of gold was deposited atop the titanium layer. The gold‐coated coverslips were then submerged into a solution of thiolated molecules to functionalize the gold with biotin motifs, which was comprised of β‐mercaptoethanol (βME; Sigma‐Aldrich, St. Louis, MO), 2 kDa methoxy‐poly(ethylene glycol)‐thiol (mPEG‐SH; Laysan Bio, Arab, AL), and 2 kDa biotin‐PEG‐SH (Nanocs, New York, NY) at a molar ratio of 95:3:2, respectively, in 200 proof ethanol (Thermo Fisher Scientific, Waltham, MA). The coverslips were incubated in the solution overnight at room temperature in a dark environment. Excess thiolated molecules were rinsed away with ethanol. The biotin‐functionalized, gold‐coated coverslips (referred to as biochips) were then dried with nitrogen gas and fastened to a 64‐well ProPlate microarray system (Sigma‐Aldrich, St. Louis, MO).

Antibody Functionalization of the Biochip Surface

The working volume utilized for an individual well was 20 µL, which was kept constant for the different solutions added into the wells. Furthermore, all incubation steps were performed on a shaker to ensure a uniform coating of the solution throughout the well surface. Before antibody functionalization, each well was washed by pipetting DI water up and down 10 times. Then, a 50‐µg/mL solution of NeutrAvidin (NA; Thermo Fisher Scientific) diluted in phosphate‐buffered saline (PBS; Thermo Fisher Scientific) was added into each well and incubated at room temperature for 1 hr to bind to the biotin motifs functionalized on the gold surface of the biochip. Excess NA was rinsed away by pipetting PBS up and down 10 times. The rinsing process was repeated three times. Capture antibodies and recombinant proteins previously biotinylated via the EZ‐Link micro Sulfo‐NHS‐biotinylation kit (Thermo Fisher Scientific) were diluted to a concentration of 10 µg/mL in a 1% (w/v) solution of bovine serum albumin (BSA; Sigma‐Aldrich) in PBS. Specific capture antibodies or recombinant proteins to immobilize subpopulations (Table S1) were added into each well and incubated at room temperature for 1 hr. Excess antibodies and recombinant proteins were rinsed away by pipetting PBS up and down 10 times for three repetitions.

Saliva Collection

Following Institutional Review Board protocol 2021H0246 (Biomedical Sciences Committee at The Ohio State University), a de‐identified cohort comprising 30 healthy donors, 33 symptomatic patients, and 20 asymptomatic patients was enrolled from which saliva was collected with written informed consent. Pooled healthy donor saliva was defined as the combined saliva from five healthy donors. After collection, the saliva was centrifuged at 2000 × g for 10 min and stored at −80 °C. All saliva samples were inactivated at 56 °C for 30 min prior to purification.

Nasopharyngeal Swab (NS) Collection

A de‐identified cohort of 19 healthy donors and 40 patients was collected with written informed consent following the Institutional Review Board protocol 2021H0246 (Biomedical Sciences Committee at The Ohio State University). All NS samples were inactivated at 56 °C for 30 min prior to purification.

Plasma Collection

Plasma samples were provided from a cohort of 7 participants with COVID‐19 with written informed consent, in accordance with the Code of Federal Regulations Title 45: Public Welfare Part 46: Protection of Human Subjects (45 CFR 46).[ 76 ] After collection, the plasma samples were stored at −80 °C. All plasma samples were inactivated at 56 °C for 30 min prior to purification. Defibrination of plasma samples was performed by adding 4.4 U/mL of thrombin (TMEXO‐1, System Biosciences) to the plasma samples, incubating for 5 min, centrifuging at 10 000 × g at room temperature for 5 min, and collecting the supernatant.

Microorganism Collection

Viruses, bacteria, and fungi were obtained from the Biodefense and Emerging Infections (BEI) Resources Repository, American Type Culture Collection (ATCC), and the Department of Pathology at The Ohio State University Wexner Medical Center. All viruses, bacteria, and fungi were inactivated at 56 °C for 30 min and diluted to the tested concentrations (Table S2).

Biofluid Sample Purification

Biofluid samples were purified via size‐exclusion chromatography (qEV; Izon Science, Christchurch, New Zealand) according to the manufacturer's instructions. Briefly, a 200 µL biofluid sample was introduced through the column pre‐wetted with PBS, whereby fractions 7 – 12 were collected. The purified samples were then re‐concentrated to 200 µL with spin columns (10 kDa MWCO, Millipore Sigma Amicon Ultra Centrifugal Filter Unit, Fisher Scientific) at 4 °C at 3000 × g.

Molecular Beacon Hybridization to Membrane‐enveloped Virion RNA

Molecular beacons (Table S10) were diluted to a concentration of 5 µM in 12.5 × Tris EDTA (TE) buffer (Sigma‐Aldrich) diluted in DI water to stabilize the molecular beacons and permeabilize the membrane encasing the RNAs.[ 45 ] The molecular beacon cocktail was diluted 25 times within the purified biofluid sample and allowed to incubate for 2 hr at 37 °C in a dark environment to facilitate molecular beacon hybridization to the target RNA.

Capture of Virions and Extracellular Vesicles (EVs)

A 3% (w/v) solution of BSA in PBS was incubated in each well at room temperature for 1 hr to block non‐specific capture. After the removal of BSA, the biofluid samples containing virions or EVs (including pre‐hybridized and untreated samples) were subsequently incubated in the wells of BARA for 2 hr at room temperature in a dark environment. For the untreated samples, excess virions and EVs were washed by pipetting PBS up and down 10 times for a total of 3 repetitions. For the pre‐hybridized samples, PBS was incubated in the wells for 5 min then pipetted up and down 10 times to remove excess virions and EVs and unhybridized molecular beacons. The rinsing step was repeated 4 times in a dark environment.

Immunofluorescence of Membrane Proteins

A 3% (w/v) solution of BSA in PBS was incubated in each well at room temperature for 1 hr to block the non‐specific adhesion of the fluorescent‐dye‐conjugated antibodies. After withdrawing the BSA solution, a 1‐µg/mL solution of the fluorescent‐dye‐conjugated antibodies (Table S1) in 10% (w/v) normal goat serum (NGS; Thermo Fisher Scientific) was subsequently incubated in the wells for 1 hr at room temperature in a dark environment. Excess fluorescent‐dye‐conjugated antibodies were rinsed and removed by incubating in PBS for 5 min then pipetting up and down the solution 10 times. The rinsing step was repeated 3 times in a dark environment.

Image Acquisition and Processing

A 10 × 10 array of images was acquired via total internal reflection fluorescence microscopy (TIRFM; Nikon, Melville, NY) for each well with a 100 × objective and immersion oil to reduce surface refraction. Exposure times and laser power were maintained across experiments to ensure the consistency of the assay. TIRFM images were quantified by measuring the total and mean fluorescence intensity of each spot detected by TIRFM. Histograms were generated with the total and mean intensities of the single spots detected by TIRFM. Scatter plots were generated with the mean intensity and size of the single spots detected by TIRFM. Relative and total fluorescence intensities of the sample were obtained from custom‐built algorithms that were previously reported.[ 38 , 44 ] Thresholds to determine positivity were based on the Clinical and Laboratory Standards Institute (CLSI) EP17‐A.[ 77 ] Briefly, the limit of blank (LoB) was determined as the total fluorescence intensities of pooled healthy donor saliva for antigenic and nucleic acid detection. Various concentrations of the USA‐WA1/2020 virion were spiked into pooled healthy donor saliva, ranging from 50 to 5000000 particles/mL, where the first dilution to provide positivity for all replicates was considered for the LoD. The LoD was calculated using the following formula.

LoD=LoB+1.645SDlowestdetection,whereLoB=meanblank+1.645SDblank (1)

Real‐time Quantitative Reverse Transcription‐polymerase Chain Reaction (qRT‐PCR)

Membrane‐enveloped RNA was isolated with the miRNeasy Serum/Plasma kit (Qiagen, Hilden, Germany) and the Single Cell RNA Purification Kit (Sigma‐Aldrich) according to the manufacturer's instructions. The isolated RNA was combined with random primers (Thermo Fisher Scientific) and was heated to 70 °C for 2 min to ensure that the target RNA was single‐stranded and cooled to 4 °C to anneal the primers. A solution containing Moloney murine leukemia virus reverse transcriptase (MMLV‐RT; Thermo Fisher Scientific) and deoxyribonucleotide triphosphate (dNTP; Thermo Fisher Scientific) in a buffer comprised of dithiothreitol (DTT; Thermo Fisher Scientific), RNaseOUT Recombinant Ribonuclease Inhibitor (Thermo Fisher Scientific), and Maxima First Strand cDNA Synthesis Kit Reaction Mix (Thermo Fisher Scientific) was heated to 42 °C for 1 hr to synthesize cDNA, then heated to 95 °C for 5 min to deactivate the RT, and subsequently cooled to 4 °C for storage purposes. The cDNA was introduced to a TaqMan Fast Advanced Master Mix (Thermo Fisher Scientific) and combined with probes targeting the open reading frame (ORF1ab), the spike protein, the nucleocapsid protein, and the human ribonuclease P RNA component H1 gene (RPPH1; RNase P) as a positive control as provided by the TaqMan 2019‐nCoV Assay Kit v1 (Thermo Fisher Scientific). Real‐time qRT‐PCR was performed on the sample with an activation step of 95 °C for 20 s followed by 45 cycles of denaturing at 95 °C for 3 s and annealing and extending at 60 °C for 30 s.

Tunable Resistive Pulse Sensing (TRPS)

The qNano Gold (Izon Sciences) was utilized to quantify the size and concentrations of virions and EV‐enriched subpopulations with NP300 (150–900 nm) and NP100 (50–330 nm) nanopore membranes. A pressure of 10 mbar was applied during measurements. The samples were calibrated to polystyrene nanoparticles (CPC200, CPC100).

Transmission Electron Microscopy (TEM)

Two 20 µL droplets of water for injection (WFI) and two 20 µL droplets of negative stain (UranyLess EM stain, Electron Microscopy Sciences) were placed on a strip of parafilm. The TEM grid was subjected to plasma treatment for 1 min. Then, 10 µL of a SARS‐CoV‐2 virion solution was carefully placed onto the treated surface of the grid. The virions solution was incubated on the surface of the grid surface for 1 min and gently blotted with filter paper to remove excess liquid. The virion‐coated grids were submerged into the WFI droplet and blotted dry using filter paper. The process was repeated with the second WFI droplet. The virion‐coated grids were stained via submersion into the first droplet of the negative stain, followed by blotting, and then submerging again into the second droplet of the negative stain. The grid was allowed to incubate in the stain for approximately 22 seconds before gently wicking away the excess solution using filter paper. To ensure thorough drying, the stained grids were stored in a grid box overnight. Afterward, TEM imaging was performed using a Tecnai TF‐20 microscope (FEI Company, Hillsboro, OR) operating at 200 kV.

Scanning Electron Microscopy (SEM)

BARA with SARS‐CoV‐2 virions captured on the surface with recombinant ACE2 was dehydrated with increasing ethanol concentrations (70, 85, 95, and 100% (v/v)) for 5 min each. Lastly, BARA was immersed in hexamethyldisilazane (HMDS, Sigma‐Aldrich) for 10 min and air‐dried overnight. The samples were imaged using an Apreo 2 SEM (FEI Company, Hillsboro, OR).

Flow Cytometry

Flow cytometry was carried out under the recommendation of MIFlowCyt‐EV.[ 78 ] SARS‐CoV‐2 virions were stained with antibodies targeting the spike glycoprotein and molecular beacons targeting the nucleocapsid‐encoding RNA (Table S10). MLV virions were used as an isotype control and PBS as a negative control. The samples were stained following the same protocol. To confirm SARS‐CoV‐2 signals, samples were treated with 0.5% Triton X‐100 for 30 min at room temperature to lyse the stained SARS‐CoV‐2, according to the reported protocol.[ 79 ] Data acquisition was performed on an ImageStreamX Mark II imaging flow cytometer (MilliporeSigma, Burlington, MA, USA) using INSPIRE software. All samples were measured following the same acquisition protocol. Calcium and magnesium‐free PBS was used as sheath fluid. In brief, a flow speed of 44 mm −1s and a 7 µm diameter core size was utilized. The camera was set to the highest bin mode resolution, a sensitivity of 32 for all channels, a gain of 1, and a gain of 1 on the second camera. All acquisition was performed at a 60× magnification. The 561‐nm laser at channel 3 was set to a power of 200 mW, the 642‐nm laser at channel 11 was set to a power of 150 mW, and the 785‐nm laser for exciting side scatter (SSC) at channel 6 was set to a power 70 mW, where channel 1 was used for bright field with an LED intensity at 52.83 mW. The fluorescence signals of spike glycoprotein and molecular beacons were collected in channel 11 and channel 3, respectively. All sample events were acquired for 3 min. Data analysis was performed using Amnis IDEAS software (version 6.2.64.0). Gating was performed based on unstained, buffer‐stained, and stained samples.

Statistical Analysis

Statistics analyses were performed using the JMP Pro 14 software (JMP, Cary, NC) and Excel (Microsoft, Redmond, WA), where statistical significances were satisfied with p < 0.05.

Conflict of Interest

E.R. and K.T.N. have filed a Patent Cooperation Treaty application for BARA technology.

Author Contributions

E.R. conceived the idea. K.T. N., and X. Y. R. contributed equally to this work and co‐first author. K.T.N., and E.R. developed the BARA technology. K.T.N., L.J.L., and E.R. designed the study. K.T.N., X.Y.R., L.T.H.N., X.W., and E.R. analyzed the data. K.T.N., X.Y.R., E.R., and S.M.M. prepared the figures and wrote the manuscript with input from all authors. K.T.N., L.T.H.N., and M.J.Y. performed BARA experiments, qRT‐PCR, TEM, flow cytometry, and biomarker characterization. K.J.K. designed the molecular beacons and prepared the biochips. X.W. and X.Y.R. developed the custom‐built algorithm for image analysis. C.‐L.C. performed on‐chip qRT‐PCR analysis. K.T.N., L.T.H.N., and M.J.Y. purified virions, and EVs using qEV. A.F.P. provided purification protocols. M.J.Y. and X.Y.R. performed TRPS measurements. J.D.‐R. obtained healthy donor blood. K.S., S.F., I.L., K.W., P.P., H.G.K., J.D.G., and J.R.H. provided clinical samples, qRT‐PCR results, and patient clinical information. H.L. and X.W. assisted with biochip preparation. E.R. supervised the project and edited the manuscript. All authors have read and approved the final manuscript.

Supporting information

Supporting Information

ADHM-14-0-s001.docx (11.4MB, docx)

Acknowledgements

We acknowledge all the patients and healthy volunteers participating in this study. We thank BEI Resources for providing the microorganism for cross‐reactivity and microbial interference tests. We thank Dr. Eliah Aronoff‐Spencer, Dr. Aaron Carlin, and Dr. Yves Theriault for preparing and providing the different SARS‐CoV‐2 variants used in this study. We thank the RADx‐Radical Network for fruitful discussions during the development of this work. We thank Dr. Xiaokui Mo for helpful advice on the statistical tests. We thank Anthony McCoy, Michael Wilson, and Leigh Evrard for their assistance. Electron microscopy was performed at the Center for Electron Microscopy and Analysis (CEMAS) at The Ohio State University. High‐resolution flow cytometry was performed at Flow Cytometry Shared Resource (FCSR) at The Ohio State University, Comprehensive Cancer Center. We thank Anthony S. Baker and Courtney Fleming at the Health Sciences Library Medical Visuals at The Ohio State University for the illustration artwork This work was supported by the U.S. National Institutes of Health (NIH) grants UG3/UH3TR002884 (E.R.) and U18TR003807 (E.R., L.J.L., P.P., K.W., & I.L.). Additional support for E.R. was provided by the William G. Lowrie Department of Chemical and Biomolecular Engineering and the James Comprehensive Cancer Center at The Ohio State University. Additional support includes Kaplan Cancer Research Fund (H.G.K.), Wilke Family Foundation (J.R.H.), the Murdock Trust (J.R.H.), the Parker Institute for Cancer Immunotherapy (J.R.H.), Merck and the Biomedical Advanced Research and Development Authority under Contract HHSO10201600031C (J.R.H.), the Swedish Medical Center Foundation (J.D.G.), DOD W911NF‐17‐2‐0086 (K.W. & I.L.), National Cancer Institute (NCI) subsidized Shared Resource P30CA016058.

Nguyen K. T., Rima X. Y., Nguyen L. T. H., Wang X., Kwak K. J., Yoon M. J., Li H., Chiang C.‐L., Doon‐Ralls J., Scherler K., Fallen S., Godfrey S. L., Wallick J. A., Magaña S. M., Palmer A. F., Lee I., Nunn C. C., Reeves K. M., Kaplan H. G., Goldman J. D., Heath J. R., Wang K., Pancholi P., Lee L. J., Reátegui E., Integrated Antigenic and Nucleic Acid Detection in Single Virions and Extracellular Vesicles with Viral Content. Adv. Healthcare Mater. 2025, 14, 2400622. 10.1002/adhm.202400622

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  • 1. Jones K. E., Patel N. G., Levy M. A., Storeygard A., Balk D., Gittleman J. L., Daszak P., Nature 2008, 451, 990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Plowright R. K., Parrish C. R., McCallum H., Hudson P. J., Ko A. I., Graham A. L., Lloyd‐Smith J. O., Nat. Rev. Microbiol. 2017, 15, 502. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Karesh W. B., et al., Lancet 2012, 380, 1936. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Chu I. Y., Alam P., Larson H. J., Lin L., J Travel Med 2020, 27. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Delassalle N., Cavaciuti M., Dimens Crit Care Nurs 2023, 42, 53. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Bavel J. J. V., Baicker K., Boggio P. S., Capraro V., Cichocka A., Cikara M., Crockett M. J., Crum A. J., Douglas K. M., Druckman J. N., Drury J., Dube O., Ellemers N., Finkel E. J., Fowler J. H., Gelfand M., Han S., Haslam S. A., Jetten J., Kitayama S., Mobbs D., Napper L. E., Packer D. J., Pennycook G., Peters E., Petty R. E., Rand D. G., Reicher S. D., Schnall S., Shariff A., et al., Nat Hum Behav 2020, 4, 460. [DOI] [PubMed] [Google Scholar]
  • 7. Pedrosa A. L., Bitencourt L., Fróes A. C. F., Cazumbá M. L. B., Campos R. G. B., de Brito S. B. C. S., Simões e Silva A. C., Front Psychol 2020, 11, 566212 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. World Health Organization. WHO Coronavirus (COVID‐19) Dashboard. Available online: https://covid19.who.int/(accessed) on 2023.
  • 9. Holmes E. C., Science 2022, 375, 1114. [DOI] [PubMed] [Google Scholar]
  • 10. Carlson C. J., Albery G. F., Merow C., Trisos C. H., Zipfel C. M., Eskew E. A., Olival K. J., Ross N., Bansal S., Nature 2022, 607, 555. [DOI] [PubMed] [Google Scholar]
  • 11. Baker R. E., Mahmud A. S., Miller I. F., Rajeev M., Rasambainarivo F., Rice B. L., Takahashi S., Tatem A. J., Wagner C. E., Wang L.‐F.a, Wesolowski A., Metcalf C. J. E., Nat. Rev. Microbiol. 2022, 20, 193. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Bird B. H., Mazet J. A. K., Annu Rev Anim Biosci 2018, 6, 121. [DOI] [PubMed] [Google Scholar]
  • 13. Long Q.‐X., Tang X.‐J., Shi Q.‐L., Li Q., Deng H.‐J., Yuan J., Hu J.‐L.i, Xu W., Zhang Y., Lv F.a‐J., Su K., Zhang F., Gong J., Wu B.o, Liu X.‐M., Li J.‐J., Qiu J.‐F.u, Chen J., Huang A.i‐L., Nat. Med. 2020, 26, 1200. [DOI] [PubMed] [Google Scholar]
  • 14. Sethuraman N., Jeremiah S. S., Ryo A., JAMA, J. Am. Med. Assoc. 2020, 323, 2249. [DOI] [PubMed] [Google Scholar]
  • 15. Jacofsky D., Jacofsky E. M., Jacofsky M., J Arthroplasty 2020, 35, S74. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Lou B., et al., Eur Respir J 2020, 56. [Google Scholar]
  • 17. Tahamtan A., Ardebili A., Expert Rev. Mol. Diagn. 2020, 20, 453. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Teymouri M., Mollazadeh S., Mortazavi H., Naderi Ghale‐noie Z., Keyvani V., Aghababaei F., Hamblin M. R., Abbaszadeh‐Goudarzi G., Pourghadamyari H., Hashemian S. M. R., Mirzaei H., Pathol Res Pract 2021, 221, 153443. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Zhang Y., Garner R., Salehi S., Rocca M., Duncan D., Future Virol. 2022, 17, 675. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Craig N., et al., Viruses 2022, 14.36680055 [Google Scholar]
  • 21. Liu Y., Kumblathan T., Tao J., Xu J., Feng W., Xiao H., Hu J., Huang C. V., Wu Y., Zhang H., Li X.‐F., Le X. C., Trends Analyt Chem 2023, 165, 117107. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Cosimi L. A., Kelly C., Esposito S., Seitz S., Turcinovic J., Connor J. H., Hung D., JAMA Netw Open 2022, 5, e2225331. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Wu Y., Kwak K. J., Agarwal K., Marras A., Wang C., Mao Y., Huang X., Ma J., Yu B.o, Lee R., Vachani A., Marcucci G., Byrd J. C., Muthusamy N., Otterson G., Huang K., Castro C. E., Paulaitis M., Nana‐Sinkam S. P., Lee L. J., Anal. Chem. 2013, 85, 11265. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Hepp C., et al., Sci Rep 2021, 11, 19579. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Zhang Y., Bahns J. T., Jin Q., Divan R., Chen L., Anal. Biochem. 2006, 356, 161. [DOI] [PubMed] [Google Scholar]
  • 26. Shiaelis N., Tometzki A., Peto L., McMahon A., Hepp C., Bickerton E., Favard C., Muriaux D., Andersson M., Oakley S., Vaughan A., Matthews P. C., Stoesser N., Crook D. W., Kapanidis A. N., Robb N. C., ACS Nano 2023, 17, 697. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Watanabe K., Wu H. Y., Xavier J., Joshi L. T., Vollmer F., Small 2022, 18, e2107597. [DOI] [PubMed] [Google Scholar]
  • 28. Patolsky F., Zheng G., Hayden O., Lakadamyali M., Zhuang X., Lieber C. M., Proc Natl Acad Sci U S A 2004, 101, 14017. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Nava G., et al.,Small 2023, 19, e2300947. [DOI] [PubMed] [Google Scholar]
  • 30. Wang S., Shan X., Patel U., Huang X., Lu J., Li J., Tao N., Proc Natl Acad Sci U S A 2010, 107, 16028. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31. Xia Q., Guo Z., Zong H., Seitz S., Yurdakul C., Ünlü M. S., Wang L.e, Connor J. H., Cheng J.i‐X., Nat. Commun. 2023, 14, 6655. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32. Nolte‐’t Hoen E., Cremer T., Gallo R. C., Margolis L. B., Proc Natl Acad Sci U S A 2016, 113, 9155. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Dhiman N., Awasthi R., Sharma B., Kharkwal H., Kulkarni G. T., Front Chem 2021, 9, 580118. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Willms E., Cabañas C., Mäger I., Wood M. J. A., Vader P., Front Immunol 2018, 9, 738. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. Chiang C. Y., Chen C., J Biomed Sci 2019, 26, 9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36. Dechantsreiter S., Ambrose A. R., Worboys J. D., Lim J. M. E., Liu S., Shah R., Montero M. A., Quinn A. M., Hussell T., Tannahill G. M., Davis D. M., J Extracell Vesicles 2022, 11, e12215. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Panagopoulou M. S., Wark A. W., Birch D. J. S., Gregory C. D., J Extracell Vesicles 2020, 9, 1710020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Rima X. Y., Zhang J., Nguyen L. T. H., Rajasuriyar A., Yoon M. J., Chiang C.‐L., Walters N., Kwak K. J., Lee L. J., Reátegui E., Lab Chip 2022, 22, 2502. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Zhou J., Wu Z., Hu J., Yang D., Chen X., Wang Q., Liu J., Dou M., Peng W., Wu Y., Wang W., Xie C., Wang M., Song Y., Zeng H., Bai C., Sci. Adv. 2020, 6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40. Han C., Kang H., Yi J., Kang M., Lee H., Kwon Y., Jung J., Lee J., Park J., J Extracell Vesicles 2021, 10, e12047. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41. Lee K., Fraser K., Ghaddar B., Yang K., Kim E., Balaj L., Chiocca E. A., Breakefield X. O., Lee H., Weissleder R., ACS Nano 2018, 12, 494. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42. Spitzberg J. D., Ferguson S., Yang K. S., Peterson H. M., Carlson J. C. T., Weissleder R., Nat. Commun. 2023, 14, 1239. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43. Breitwieser K., Koch L. F., Tertel T., Proestler E., Burgers L. D., Lipps C., Adjaye J., Fürst R., Giebel B., Saul M. J., Int. J. Mol. Sci. 2022, 23. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44. Nguyen L. T. H., Zhang J., Rima X. Y., Wang X., Kwak K. J., Okimoto T., Amann J., Yoon M. J., Shukuya T., Chiang C.‐L., Walters N., Ma Y., Belcher D., Li H., Palmer A. F., Carbone D. P., Lee L. J., Reátegui E., J Extracell Vesicles 2022, 11, e12258. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45. Zhang J., Rima X. Y., Wang X., Nguyen L. T. H., Huntoon K., Ma Y., Palacio P. L., Nguyen K. T., Albert K., Duong‐Thi M.‐D., Walters N., Kwak K. J., Yoon M. J., Li H., Doon‐Ralls J., Hisey C. L., Lee D., Wang Y., Ha J., Scherler K., Fallen S., Lee I., Palmer A. F., Jiang W., Magaña S. M., Wang K., Kim B. Y. S., Lee L. J., Reátegui E., J Extracell Vesicles 2023, e12369. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Floyd D. L., Ragains J. R., Skehel J. J., Harrison S. C., van Oijen A. M., Proc Natl Acad Sci U S A 2008, 105, 15382. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47. Ivanchenko S., et al., PLoS Pathog. 2009, 5, e1000652. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48. Baumgärtel V., Ivanchenko S., Dupont A., Sergeev M., Wiseman P. W., Kräusslich H.‐G., Bräuchle C., Müller B., Lamb D. C., Nat. Cell Biol. 2011, 13, 469. [DOI] [PubMed] [Google Scholar]
  • 49. Walls A. C., Park Y.‐J., Tortorici M. A., Wall A., McGuire A. T., Veesler D., Cell 2020, 181, 281. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Letko M., Marzi A., Munster V., Nat. Microbiol. 2020, 5, 562. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51. Harvey W. T., Carabelli A. M., Jackson B., Gupta R. K., Thomson E. C., Harrison E. M., Ludden C., Reeve R., Rambaut A., Peacock S. J., Robertson D. L., Nat. Rev. Microbiol. 2021, 19, 409. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52. Ota K., Yanagihara K., Sasaki D., Kaku N., Uno N., Sakamoto K., Kosai K., Miyazaki T., Hasegawa H., Fujita A., Tashiro M., Tanaka T., Izumikawa K., Ariyoshi K., Mukae H., Yasuda J., Morita K., Kohno S., PLoS One 2021, 16, e0252964. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53. Hellewell J., Russell T. W., Beale R., Kelly G., Houlihan C., Nastouli E., Kucharski A. J., BMC Med. 2021, 19, 106.33902581 [Google Scholar]
  • 54. Thaweethai T., et al., JAMA, J. Am. Med. Assoc. 2023, 329, 1934. [Google Scholar]
  • 55. Mina Y., et al., Neurol Neuroimmunol Neuroinflamm 2023, 10. [Google Scholar]
  • 56. Xie Y., Xu E., Bowe B., Al‐Aly Z., Nat. Med. 2022, 28, 583. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57. Davis H. E., McCorkell L., Vogel J. M., Topol E. J., Nat. Rev. Microbiol. 2023, 21, 133. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58. Sato K., Aoki J., Misawa N., Daikoku E., Sano K., Tanaka Y., Koyanagi Y., J. Virol. 2008, 82, 1021. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59. Kowal J., Arras G., Colombo M., Jouve M., Morath J. P., Primdal‐Bengtson B., Dingli F., Loew D., Tkach M., Théry C., Proc Natl Acad Sci U S A 2016, 113, E968. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60. Troyer Z., Alhusaini N., Tabler C. O., Sweet T., de Carvalho K. I. L., Schlatzer D. M., Carias L., King C. L., Matreyek K., Tilton J. C., J Extracell Vesicles 2021, 10, e12112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61. Greenberg C. S., Miraglia C. C., Rickles F. R., Shuman M. A., J. Clin. Invest. 1985, 75, 1463. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62. Proal A. D., VanElzakker M. B., Front Microbiol 2021, 12, 698169. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63. Li H., Chiang C.‐L., Kwak K. J., Wang X., Doddi S., Ramanathan L. V., Cho S. M., Hou Y.a‐C., Cheng T.‐S., Mo X., Chang Y.‐S., Chang H.‐L., Cheng W., Tsai W.‐N.i, Nguyen L. T. H., Pan J., Ma Y., Rima X. Y., Zhang J., Reategui E., Chu Y.‐S., Chang P. M.u‐H., Chang P.‐H., Huang C.‐Y. F., Wang C.‐H., Shan Y.‐S., Li C.‐P., Fleisher M., Lee L. J., Adv. Sci. (Weinh) 2024, 11, e2306373. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 64. Nikolai L. A., Meyer C. G., Kremsner P. G., Velavan T. P., Int J Infect Dis 2020, 100, 112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65. Walsh K. A., Jordan K., Clyne B., Rohde D., Drummond L., Byrne P., Ahern S., Carty P. G., O'Brien K. K., O'Murchu E., O'Neill M., Smith S. M., Ryan M., Harrington P., J Infect 2020, 81, 357. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66. Jarvis K. F., Kelley J. B., Sci. Rep. 2021, 11, 9221. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67. Arevalo‐Rodriguez I., Buitrago‐Garcia D., Simancas‐Racines D., Zambrano‐Achig P., Del Campo R., Ciapponi A., Sued O., Martinez‐García L., Rutjes A. W., Low N., Bossuyt P. M., Perez‐Molina J. A., Zamora J., PLoS One 2020, 15, e0242958. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 68. Mouliou D. S., Gourgoulianis K. I., Expert Rev. Respir. Med. 2021, 15, 993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69. Kucirka L. M., Lauer S. A., Laeyendecker O., Boon D., Lessler J., Ann. Intern. Med. 2020, 173, 262. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70. Wiersinga W. J., Rhodes A., Cheng A. C., Peacock S. J., Prescott H. C., JAMA 2020, 324, 8544. [DOI] [PubMed] [Google Scholar]
  • 71. Im H., Shao H., Park Y. I.l, Peterson V. M., Castro C. M., Weissleder R., Lee H., Nat. Biotechnol. 2014, 32, 490. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 72. He W. T., et al., Cell 2022, 185, e1118. [Google Scholar]
  • 73. Groff D., Sun A., Ssentongo A. E., Ba D. M., Parsons N., Poudel G. R., Lekoubou A., Oh J. S., Ericson J. E., Ssentongo P., Chinchilli V. M., JAMA Netw Open 2021, 4, e2128568. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 74. Frontera J. A., Thorpe L. E., Simon N. M., de Havenon A., Yaghi S., Sabadia S. B., Yang D., Lewis A., Melmed K., Balcer L. J., Wisniewski T., Galetta S. L., PLoS One 2022, 17, e0275274. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 75. Su Y., Yuan D., Chen D. G., Ng R. H., Wang K., Choi J., Li S., Hong S., Zhang R., Xie J., Kornilov S. A., Scherler K., Pavlovitch‐Bedzyk A. J., Dong S., Lausted C., Lee I., Fallen S., Dai C. L., Baloni P., Smith B., Duvvuri V. R., Anderson K. G., Li J., Yang F., Duncombe C. J., McCulloch D. J., Rostomily C., Troisch P., Zhou J., Mackay S., et al., Cell 2022, 185, 881. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 76. Su Y., et al., Cell 2020, 183, e1420. [Google Scholar]
  • 77. NCCLS, [ISBN 1‐56238‐551‐8]. NCCLS, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087‐1898 USA, 2004.
  • 78. Welsh J. A., Van Der Pol E., Arkesteijn G. J. A., Bremer M., Brisson A., Coumans F., Dignat‐George F., Duggan E., Ghiran I., Giebel B., Görgens A., Hendrix A.n, Lacroix R., Lannigan J., Libregts S. F. W. M., Lozano‐Andrés E., Morales‐Kastresana A., Robert S., De Rond L., Tertel T., Tigges J., De Wever O., Yan X., Nieuwland R., Wauben M. H. M., Nolan J. P., Jones J. C., J Extracell Vesicles 2020, 9, 1713526. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 79. Lamy E., Rubio C. P., Carreira L., Capela e Silva F., Martinez‐Subiela S., Tecles F., Lopez‐Jornet P., Ceron J. J., Tvarijonaviciute A., Sci. Rep. 2022, 12, 9434. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supporting Information

ADHM-14-0-s001.docx (11.4MB, docx)

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.


Articles from Advanced Healthcare Materials are provided here courtesy of Wiley

RESOURCES