Skip to main content
. 2005 Jul;12(7):885–887. doi: 10.1128/CDLI.12.7.885-887.2005

TABLE 1.

Comparison of ICT with ELISA for detection of antibodies to N. caninum in cattle

ELISAa results ICTb test results
No. (%) positive No. (%) negative Total (%)
No. (%) positive 18 (18.8) 1 (1.0) 19 (19.8)
No. (%) negative 5 (5.2) 72 (75.0) 77 (80.2)
Total (%) 23 (24.0) 73 (76.0) 96 (100)
a

Antibodies to N. caninum were detected by ELISA with GST-NcSAG1t (2). The ELISA was considered positive when an optical density at 415 nm of ≥0.1 was observed at dilutions of 1:100 and above.

b

Antibodies to N. caninum were detected by ICT with GST-NcSAG1t. The ICT was considered positive when both control and test lines turned purplish red at a dilution of 1:10.