Skip to main content
. 2005 Jun 17;6:95. doi: 10.1186/1471-2164-6-95

Table 1.

Number of negative and positive signals predicted by in silico analysis and recorded by comparative genome hybridization on StaphChip for N315, Mu50, or COL targets. Differences between expected and recorded signals are also shown.

S. aureus genome
N315 Mu50 COL

Positive Signal Predicted 5,219 5,307 4,851
Recorded 5,216 5,304 4,819
Missed 3 3 32

Negative Signal Predicted* 116 28 484
Recorded 107 20 397
Differences 9 8 87

*See Figure 2.