TABLE 2.

Fe-bead reduction in the presence of electron shuttles or chelators

Sample assayed Reduction rate [μM Fe(II)/h]
MR-1a 1.23 ± 0.00
MR-1 + 1 μM AQDS 10.86 ± 0.63
MR-1 + 1 μM PMS 1.93 ± 0.09
MR-1 + 2.5 μM PMS 2.08 ± 0.32
MR-1 + 5 μM PMS 2.55 ± 0.20
MR-1 + 10 μM PMS 3.51 ± 0.25
MR-1 + 25 μl/ml anaerobic cell lysate 3.23 ± 0.18
MR-1 + 10 μl/ml anaerobic cell lysate 2.68 ± 0.29
MR-1 + 5 μl/ml anaerobic cell lysate 2.08 ± 0.06
MR-1 + 2.5 μl/ml anaerobic cell lysate 1.41 ± 0.17
MR-1 + 10 μM MK-4 1.13 ± 0.13
MR-1 + 10 μM DHNA 1.20 ± 0.17
MR-1 + 25 μM NTA 1.16 ± 0.03
MR-1 + 25 μM citrate 1.20 ± 0.01
MR-1 + 25 μM Fe(II) 1.17 ± 0.11
MR-1 + 1,000 μM Fe(II) 1.46 ± 0.08
a

MR-1 reduced 50 μM Fe(III) in the initial 24 h of the experiment.