Skip to main content
[Preprint]. 2025 Apr 1:2025.02.11.25322107. Originally published 2025 Feb 13. [Version 2] doi: 10.1101/2025.02.11.25322107

Table 2.2:

Consistency Between Extracted Histology and IHC/FISH Results

Chromophobe RCC Papillary RCC CCPRCT Clear cell RCC TFE3 Rearranged RCC TFEB Altered RCC
Total Number of Specimens 84 119 62 1630 6 5
CAIX Expected → Extracted ↓ Negative Focal/Patchy Positive or Negative Positive (Cup-Like) Positive or Positive (Box-Like) Negative Negative
Positive (Cup-Like) 0 1^ 61 3^ 0 0
Positive (Box-Like) 0 0 2* 164 0 0
Focal/Patchy Positive 0 22 0 6* 0 1
Other Positive 0 6 3 548 0 0
Negative 24 15 0 2* 5 3
CD117 Expected → Extracted ↓ Positive Negative Negative Negative Negative Negative
Positive 87 0 0 1^ 0 1*
Negative 0 4 6 26 2 3
Racemase Expected → Extracted ↓ Negative Positive Negative Mixed Mixed Mixed
Focal/Patchy Positive 0 2 0 7 0 0
Positive/Diffuse Positive 2* 99 0 9 1 2
Negative 3 0 13 4 0 0
TFE3 Expected → Extracted ↓ Negative Negative Negative Negative Rearranged Negative
Rearranged 0 0 0 0 6 0
Negative 2 7 0 6 0 4
TFEB ExpectedExtracted Negative Negative Negative Negative Negative Rearranged/Amplified
Rearranged/Amplified 0 0 0 0 0 5
Negative 2 6 0 4 6 0

Single specimens may have multiple tests, thus column totals may be higher than the number of specimens

Includes “Positive” alone, or with other modifiers not explicitly Focal/Patchy, Cup-Like, or Box-Like

*

Report reviewed and the LLM corrected a typographic mistake (STable 5 for details)

^

Report reviewed and the LLM found to have made a mistake (STable 5 for details)