Variable DXA HRpQCT REMS
Radiation dose, mSv ~0.0015,18,19 ~3 to 55,18,19 None5,8,11
Examination time, mins 15 to 2021 3 to 518,19 10 to 1521,22
Technology dependent Yes5,11,14 No5,17,18 No8,11
Ease of positioning No*8,11 Yes19 Yes5-9,11
Availability Yes5 Limited5,18 Yes11
Low cost Yes21 No18 Yes21,23
Dependence on bone size Yes18 No17,19 No5,8
Separates measurement between cortical and trabecular bone No5 Yes5,17 Yes5
Microarchitecture assessment Spine: only if Trabecular Bone Score module fitted5,11,24 Yes5,18,19 Yes5,24
Sampling errors Yes5,8,13 No5,19 No5,8
*