Skip to main content

This is a preprint.

It has not yet been peer reviewed by a journal.

The National Library of Medicine is running a pilot to include preprints that result from research funded by NIH in PMC and PubMed.

bioRxiv logoLink to bioRxiv
[Preprint]. 2025 Feb 27:2025.02.22.639656. [Version 1] doi: 10.1101/2025.02.22.639656

Reference Library for Suspect Non-targeted Screening of Environmental Toxicants Using Ion Mobility Spectrometry-Mass Spectrometry

Devin Teri 1, Noor A Aly 1, James N Dodds 2, Jian Zhang 3, Paul A Thiessen 3, Evan E Bolton 3, Kara M Joseph 2, Antony J Williams 4, Emma L Schymanski 5, Ivan Rusyn 1,*, Erin S Baker 2,*
PMCID: PMC11888245  PMID: 40060593

Abstract

As our health is affected by the xenobiotic chemicals we are exposed to, it is important to rapidly assess these molecules both in the environment and our bodies. Targeted analytical methods coupling either gas or liquid chromatography with mass spectrometry (GC-MS or LC-MS) are commonly utilized in current exposure assessments. While these methods are accepted as the gold standard for exposure analyses, they often require multiple sample preparation steps and more than 30 minutes per sample. This throughput limitation is a critical gap for exposure assessments and has resulted in an evolving interest in using ion mobility spectrometry and MS (IMS-MS) for non-targeted studies. IMS-MS is a unique technique due to its rapid analytical capabilities (millisecond scanning) and detection of a wide range of chemicals based on unique collision cross section (CCS) and mass-to-charge (m/z) values. To increase the availability of IMS-MS information for exposure studies, here we utilized drift tube IMS-MS to evaluate 4,685 xenobiotic chemical standards from the Environmental Protection Agency Toxicity Forecaster (ToxCast) program including pesticides, industrial chemicals, pharmaceuticals, consumer products, and per- and polyfluoroalkyl substances (PFAS). In the analyses, 3,993 [M+H]+, [M+Na]+, [M−H] and [M+]+ ion types were observed with high confidence and reproducibility (≤1% error intra-laboratory and ≤2% inter-laboratory) from 2,140 unique chemicals. These values were then assembled into an openly available multidimensional database and uploaded to PubChem to enable rapid IMS-MS suspect screening for a wide range of environmental contaminants, faster response time in environmental exposure assessments, and assessments of xenobiotic-disease connections.

Keywords: mass spectrometry, ion mobility spectrometry, non-targeted analysis, exposure assessments, environmental analysis

Introduction

Ion mobility spectrometry coupled with mass spectrometry (IMS-MS) is a non-targeted analytical technique that has stimulated great interest in both analytical chemistry and exposure science due to its ability to resolve isomeric species and distinguish halogenated chemicals (Foster et al., 2022; Ibrahim et al., 2016; Kanu et al., 2008; Kirkwood-Donelson et al., 2023; Luo et al., 2020; May and McLean, 2015; Metz et al., 2017). IMS separates ions by their shape and charge state in the gas phase through the use of an electric field, buffer gas and sometimes gas flow, depending on the IMS type utilized (e.g., drift tube, traveling wave, trapped IMS, etc.) (Hinnenkamp et al., 2018; Jurneczko et al., 2012). In addition to its millisecond analysis speed, most IMS methods also allow for the calculation of collision cross section (CCS) values for each ion detected (Ewing et al., 2016; Gabelica et al., 2019). CCS values correspond to the collision area between a charged analyte and its neutral collision partner or the buffer gas molecules in the IMS cell. In various studies, CCS values have proven to be highly reproducible (often less than 2% of each other) between laboratories using the same instrumentation, even in complex samples (Stow et al., 2017). Additionally, CCS values for the same molecule evaluated with the different IMS methods are often within 2% of each other (Hinnenkamp, et al., 2018). Therefore, CCS values are regarded as highly informative data which provide a way to increase confidence in the identification of individual molecules in non-targeted analytical studies of complex substances and mixtures (Burnum-Johnson et al., 2019; Dodds et al., 2020). Moreover, in IMS-MS studies, ions separated by IMS can be evaluated for their m/z value, and if fragmentation is applied, 3-dimensional characterization is possible (CCS, MS and MS/MS) (Dodds and Baker, 2019; Ibrahim et al., 2015).

Historically, IMS-MS has been used to study peptides, proteins, carbohydrates and inorganic molecules (May et al., 2017). More recently, studies of environmental and industrial chemicals have provided additional CCS information to enable analyses of complex environmental exposures (Aly et al., 2022; Belova et al., 2021; Celma et al., 2020; Hinnenkamp, et al., 2018; Picache et al., 2019; Zheng et al., 2018). These studies have demonstrated the use of CCS libraries in suspect screening of complex substances (Cordova et al., 2023; Luo, et al., 2020; Luo et al., 2021; Roman-Hubers et al., 2022a; Roman-Hubers et al., 2022b) and in assessing environmental samples (Celma, et al., 2020; Valdiviezo et al., 2022). The opportunities for further advancing chemical exposure analyses and determining potential adverse effects on human health are therefore rapidly evolving with analytical chemistry advances such as IMS-MS (Escher et al., 2017; Escher et al., 2020; Scholz et al., 2022; Vermeulen et al., 2020). However, improved linkages between exposure measurements and potential hazards of chemicals, such as high-throughput toxicity data (Williams et al., 2017), are still lacking due to the absence of analytical methods that can be used for rapid analyses of complex samples and mixtures (Barouki et al., 2022; Brack et al., 2016; Lai et al., 2024). Additionally, refinements to characterization of in vitro to in vivo extrapolations (IVIVE) of individual chemicals (Wambaugh et al., 2018; Wambaugh et al., 2019) and mixtures (Valdiviezo et al., 2021) would therefore benefit from improved analytical methods able to assess diverse chemicals in the environment and their metabolites in biological systems. Fortunately, government agencies have encouraged collaborative analyses of large-scale chemical libraries and mixtures by providing access to their compound libraries (Ulrich et al., 2019), enabling opportunities for developing large-scale reference datasets for suspect screening using rapid non-targeted analytical methods such as IMS-MS.

In this study, we follow up on recent studies that have aimed to establish CCS libraries for xenobiotic chemicals (Belova, et al., 2021; Celma, et al., 2020; Hinnenkamp, et al., 2018; Picache, et al., 2019) by utilizing drift tube IMS (DTIMS) and nitrogen buffer gas (denoted as DTCCSN2) to evaluate chemicals of concern to human health which have also been tested in hundreds of in vitro assays by the ToxCast/Tox21 programs (Richard et al., 2021; Williams, et al., 2017). For these analyses, we utilized an electrospray ionization (ESI) source in both positive and negative mode and an atmospheric pressure chemical ionization (APCI) source in positive mode for more comprehensive molecular coverage of the diverse chemicals. The database created from this study contains CCS values for 2,140 unique chemicals and will be of immediate interest for the chemical analyses of complex samples and environmental mixtures (Phillips et al., 2022).

Materials and Methods

Sample Preparation

The 4,685 xenobiotic chemical standards analyzed in this study (Figure 1 and Tables S1S2) were obtained from Evotec (Branford, CT; order #13169), a contractor of the U.S. Environmental Protection Agency’s (US EPA) ToxCast library of chemicals (Richard et al., 2016). Chemical selection from a ToxCast library was performed by the U.S. EPA (Dr. Ann M. Richard) based on chemical availability and the purity of the individual compounds at the time of assembly and all standards were supplied at 0.4 mM in pure dimethyl sulfoxide (DMSO). The process for selecting and registering chemicals into the ToxCast library including the description of chemical procurement from commercial suppliers, cataloguing the chemicals, storage and chemical quality control is detailed at (Richard et al., 2024; Richard et al., 2014). After selection, all chemicals were placed into sealed 384-well plates, shipped, and then stored frozen (−80 C). The certificate of analysis obtained with the chemical shipment stated all compounds were >90% purity as determined by the supplier. Before experiments, the stock plates were thawed at room temperature, 5 μL of each chemical was then transferred to individual 9 mm amber screw top vials with fused inserts (Ibis Scientific, #4400-FIV2W), and each standard was diluted to 10 μM with 195 μL of 50:50 methanol/water. The high purity (≥99.9%) water, methanol, and acetonitrile used in this study were obtained from Sigma-Aldrich (St. Louis, MO).

Figure 1. Project Workflow.

Figure 1.

In this study, we first classified the 4,685 chemical standards into 13 classes. The 4,685 standards were then diluted to 10 μM and analyzed with IMS-MS using ESI[+], ESI[−] and APPI[+]. Feature identification and collision cross section calculations were performed using Agilent IM-MS Browser and Agilent Mass Profiler. CCS values for 2,140 unique chemicals were obtained in the study and 3,993 ions from [M+H]+, [M+Na]+, [M−H] and [M+]+ ion types.

Instrumentation and Analysis

DTIMS-MS analyses were performed using the 6560 IM-QTOF MS system (Agilent Technologies, Santa Clara) and the drift tube was filled with nitrogen gas. A liquid chromatography stack (Agilent Technologies: G7116B Column Compartment, G7167B Multisampler, and G7120A High Speed Pump) was used as an autosampler to inject samples into each ionization source at 0.400 mL/min with a constant solvent composition of 50% water and 50% acetonitrile. All chemical standards were ionized using the APCI source in positive ionization mode and the ESI source in both positive and negative ionization mode.

Prior to each experiment, the instrument was tuned and mass calibrated using the Agilent Tune Mix (G2421A/G2432A, Agilent Technologies, Santa Clara, CA). For the IMS analyses, the ions were passed through the inlet glass capillary, focused by a high-pressure ion funnel, and accumulated in an ion funnel trap (Baker et al., 2007). Ions were then pulsed into the 78.24 cm long drift tube filled with ~3.95 torr of nitrogen gas, where they travelled under the influence of a weak electric field (17 V/cm). Ions exiting the drift tube were refocused by a rear ion funnel prior to quadrupole time-of-flight (QTOF) MS analysis and their drift time was recorded. The detailed instrumental settings are listed in Tables S3S5. For each detected ion, DTCCSN2 values were calculated using a single-field method which has been detailed previously (Stow, et al., 2017). Methanol washes were performed after 24 sample injections to reduce the occurrence of carryover. Additionally, isomeric chemicals were also separated by several standards with greater mass differences to ensure no interferences occurred. Samples from the same plate were run in the same worklist over six days, alternating the ion mode each day. Each chemical was injected six times total, resulting in duplicate results for each ion mode. The average DTCCSN2 values having less than 1% difference between replicates are found in Table S6.

Data Analysis and Curation

Agilent IM-MS Browser software (Agilent Technologies) was utilized for all single-field DTCCSN2 calculations, initially starting with the Tune Mix ions for use as calibrants. While software programs can assist in calculating the CCS values, every instrumental run was manually examined for the presence of a peak and the software-assigned CCS value was verified. Quality control and confidence in CCS values was determined based on the DTCCSN2 duplicate values (GraphPad, 2024) having a percent difference of ≤1 for at least two replicates (Zhang et al., 2016). The DTCCSN2 and m/z values were then plotted to identify potential trendlines. Only DTCCSN2 values that fell within 15% difference of the main trendline were determined to be confident identities and listed in the final dataset. This filtering removes small molecules which multimerize in solution, drift through the ion mobility cell as multimers, and then break into monomers following drift analysis, thereby illustrating extremely large CCS values per m/z (Baker et al., 2023).

Of the 4,685 standards evaluated herein, three chemicals were duplicated in the plates, resulting in 4,682 unique chemicals. The chemicals were assigned into classes using expert judgement of the authors using PubChem “Use and manufacturing” classifications and other pertinent information in the US EPA’s CompTox Chemicals Dashboard. Following ESI-IMS-MS and APCI-IMS-MS analyses, reproducible CCS values resulted for 2,140 unique chemicals. Moreover, due to the various ion types observed ([M+H]+, [M+Na]+, [M−H] and [M+]), the IMS-MS database contains 3,993 CCS values and the corresponding m/z ratios.

Results and Discussion

Many experimentally measured CCS datasets have been published for use in the fields of proteomics, metabolomics, steroids, and xenobiotics (Aly, et al., 2022; Belova, et al., 2021; Celma, et al., 2020; Hinnenkamp, et al., 2018; Picache, et al., 2019; Zheng, et al., 2018), but the number of CCS values is still limited, especially for xenobiotic studies. The purpose of developing a database of CCS values from the EPA’s ToxCast library is therefore to assist in identifying toxicants and improve the assessment of human and environmental risks and exposures. To create the IMS-MS ToxCast database, 4,685 chemical standards were analyzed using the workflow depicted in Figure 1. In this workflow, the chemicals were first categorized into classes, diluted, evaluated with IMS-MS, assessed for reproducible CCS values, and then added to a CCS database if they passed all quality control steps stated in the Methods section. For the categorization step, the chemicals were placed into thirteen broad classes based on their structures and use by employing information from the EPA’s ToxCast library (Williams, et al., 2017). Because most chemicals had several classifications listed, we used the source/use information in PubChem to determine the final assignments. Overall, the following assignments were made: Natural Toxin (n=6), Disinfection By-Product (n=14), PFAS (n=17), Polycyclic Aromatic Hydrocarbon (PAH, n=31), Surfactant (n=78), Flame Retardant (n=120), Plastic (n=154), Color Dye (n=172), Cosmetic Ingredient (n=360), Pharmaceutical (n=615), Food Additive (n=634), Pesticide (n=948), and Chemical Industrial (n=1,536), where the three duplicates were from the Pharmaceutical, Food Additive, and Chemical Industrial classes. It should be noted that while these classifications are subject to interpretation, the assignment of substances into these classes is commonly used in regulatory science.

For the IMS-MS analyses, each chemical standard was diluted to 10 μM and injected twice into the instrument using ESI[+], ESI[−], and APCI[+] sources. While various ions were formed in the different sources, we specifically evaluated [M−H] in the ESI[−] analyses, [M+H]+ and [M+Na]+ in the ESI[+] analyses, and [M+H]+ and [M+] in the APCI[+] studies. Furthermore, an ion was considered present if the mass error was less than 10 ppm from the expected chemical formula, in addition to the presence of the correct 13C isotopic distribution. Figure 2 shows three example chemicals following ionization using all three ion modes. These chemicals (bosentan, thiabendazole, and triamterene) represent two different chemical classes studied (two pharmaceuticals and a pesticide), each having ions observed in all analysis modes.

Figure 2. Representative Nested IMS–MS Spectra for Three Test Chemicals.

Figure 2.

Images illustrate the abundance of the isotopic distribution of the precursor [M] and first 13C isotope [M+1] peak for each chemical across the three ionization modes (ESI[−], ESI[+] and APCI[+]). For each chemical shown (Bosentan, Thiabendazole, and Triamterene), m/z values are plotted on the x-axis, and drift times on the y-axis. Colors represent abundance from red (highest) to green (intermediate), to blue (lowest). The DTXSIDs are the substance identifier associated with the US EPA’s CompTox Chemicals Dashboard.

For the 4,682 unique chemicals analyzed, ~45.7% (n=2,140) could be detected in at least one analysis mode (Figure 3). This number was not surprising as some chemicals may have degraded or were not amenable to the ionization sources used (such as some of the metals in the ToxCast library (Table S1) would need to be run with inductively coupled plasma (ICP)-MS). As expected, differences among chemical classes were observed with respect to what ionization mode was preferable for their detection. For example, of the ion species evaluated, PAHs were primarily detected with APCI[+], while PFAS were identified with ESI[−], due to the structural components of both molecular classes (Figures 3A and 3B). Figure 3A breaks down the number of chemicals in each classification detected by each ion source. Figure 3B shows the total percentage of unique chemicals detected in every classification and their ion mode for detection. Specifically, no class of chemicals was completely detected in the study, and detectability ranged from less than 20% for “Food Additives” to 75% for both “Color Dyes” and “Pharmaceuticals”. Additionally, ESI[+] provided the majority of identifications (n=1,324), and of this total 426 chemicals were detectable only with ESI[+] (Figure 3C). ESI[−] had the second most with n=1,146, and here 634 were detected only with ESI[−]. Finally, APCI[+] had the least amount of chemicals detected at n=771, and only 52 were uniquely detected with this source and polarity. To understand the positive mode detections, we also analyzed which ions were detected using ESI[+] and APCI[+] (Figure 3D). For ESI[+], the [M+H]+ and [M+Na]+ were found to have a similar rate of detection with ~36% of chemicals in ESI[+] producing both ion types. On the other hand, APCI[+] ion types were abundantly represented by [M+H]+, while [M+] detection only included 13.1% of the chemicals.

Figure 3. Detection Frequency for Tested Chemicals Across Ionization Modes and Chemical Classes.

Figure 3.

(A) Percentages of chemicals detected in each class (filled bars) using ESI[−], ESI[+], or APCI[+]. (B) Percentage of chemicals in each class detected by one or multiple ionization modes. (C) Venn diagram illustrating overlap of chemicals detected across the different ionization modes. (D) Venn diagrams showing number of ions detected in ESI[+] and APCI[+].

Because the library of CCS values for chemicals analyzed herein may be used for suspect screening of complex substances and mixtures by other laboratories, we also assessed reproducibility of CCS values. For this examination, we evaluated reproducibility both between the technical replicates in our own analyses (intra-laboratory) and the differences in our values and those published by others (inter-laboratory) using DTIMS and traveling wave IMS (TWIMS) (Figure 4). For most chemical classes, over 90% of the substances were within 1% difference. The percent difference in CCS values among the duplicate injections of each chemical were evaluated by chemical class (Figure 4A) and ionization mode (Figure 4B). Box and whisker plots show the distribution of the deviation among technical replicates, and the pie charts show the fraction of the substances with values under the generally accepted cutoff of 1%. Interestingly, “Natural Toxins” and “PFAS” had the lowest number of retained chemicals using these cutoffs with 14% and 30% removed, however, these were among the classes with the fewest number of chemicals represented in the library. With respect to ionization mode analysis, the overwhelming majority (97%) of the chemicals detected with either ESI[−] or ESI[+] had excellent reproducibility with differences in CCS ≤1%. Even though the reproducibility of CCS values was less robust with APCI[+], 91% were below the threshold of 1%. Of the 3,948 CCS values for the different ion types evaluated, only 171 were excluded from the final database because they exceeded 1% difference, resulting in 3,993 ions in the final database (Table S6).

Figure 4. Reproducibility of Collision Cross Section (CCS) Values.

Figure 4.

CCS reproducibility for the technical replicates examined in this study was assessed by (A) chemical class and (B) ionization mode (ESI[−], ESI[+], and APCI[+]). (C) CCS reproducibility between this study and other published large datasets that contained overlapping chemicals. In panels A and B, the pie charts show the fraction of the chemicals falling below a 1% threshold (white) and above 1% threshold (black), which were filtered out. The total number of chemicals is also noted below each pie chart. In panel C, the pie charts show the fractions below 2% (white), between 2 and 5% (gray), and above 5% (black). The box and whiskers plots in each panel show the distribution of the values for each detected chemical (boxes are interquartile range, the line is median, the whiskers are 5–96 percentile, and the points are outliers). Horizontal lines indicate thresholds used in each analysis.

Interlaboratory reproducibility was also determined in the study using data from six other suspect screening CCS libraries (Belova, et al., 2021; Celma, et al., 2020; Hinnenkamp, et al., 2018; May, et al., 2017; Picache, et al., 2019; Zheng et al., 2017; Zheng, et al., 2018) (Figure 4C and Tables S7S11). Our database containing 3,993 CCS values represents a great expansion on important toxicants as most of the other library values are endogenous metabolites. Furthermore, in overall CCS reproducibility assessments across laboratories (i.e., % difference), it is often considered acceptable if the difference in reported values is ≤2% to account for instrument variability. A 5% difference was also used for this comparison to consider any experimental differences. Of the chemicals that could be cross compared (from 8 to 221 depending on publication), over 87% of the CCS values had ≤2% difference and only ~2% of the compared chemicals fell above the 5% threshold. These small errors show that CCS is an intrinsic chemical property, and only slight errors occur due to differences in electric field application, CCS calibration, and pressure or temperature fluctuations in the instrumentation. Overall, these comparisons provide us with confidence in our database as all values included fell below the 1% difference threshold and we had very few values outside of the 5% difference when compared to other databases.

To finalize this study, we attempted to determine reasons for lack of detection of some of the tested compounds with IMS-MS and the ESI and APPI sources. The main two factors considered were stability of the chemicals in solution (Richard, et al., 2016), and amenability of a chemical for detection using a particular ionization source and mode (e.g., ESI[−] and ESI[+]) (Charest et al., 2024; Lowe et al., 2021). For the chemical stability analysis, we reasoned that chemicals that lack long-term stability in solution will not be detected due to potential degradation prior to analysis. To make this comparison, we were able to obtain information on long-term stability of the ToxCast library from the U.S. EPA and categorize them using this information as “stable” (i.e., no appreciable degradation) or “unstable” (chemical not detected in the analysis of a stock solution after 4 months of being stored at room temperature). Figure 5A divides the chemicals into 4 categories based on the stability and whether they were detected in at least one ionization mode. The overall number of chemicals included in this analysis was less than the total based on the availability of stability data – out of the 4,682 unique chemicals tested, data was only available for 3,659. Of these, 37.6% were both detected and stable, while 26.6% were neither detected nor stable. This result was highly significant (p<0.0001 using Fisher’s exact test) indicating that stability of the chemicals was a considerable contributor to our ability to determine their CCS value. For the chemical amenability analysis, we reasoned that chemicals that could not be ionized will not be detected. Using previously published predictive chemical amenability analyses with LC-MS (Lowe, et al., 2021), we determined which chemicals were “amenable” to ESI[−] or ESI[+] ionization (Figures 5B and 5C). For each analysis, 4,591 and 4,542 compounds out of the total of 4,682 analyzed could be predicted for each ionization mode. In the ESI[−] analysis, 71.8% of the chemicals were predicted as non-amenable. This is an indication that GC-IMS-MS should be a future goal for analysis of these chemicals. Additionally, of the amenable chemicals, 59.2% were detected in the ESI[−] evaluations. In the ESI[+] analysis, 57% of the chemicals were predicted as non-amenable and for the amenable chemicals, 55.8% were detected. These analyses demonstrated that amenability was also a major contributing factor to our ability to derive CCS values (p<0.0001 using Fisher’s exact test for both ionization modes) as many chemicals were predicted not amenable. Of additional note, all chemicals were tested at 10 μM and there was no concentration response performed in this study. Thus, it could not be determined if the concentration of the standard was below the limit of detection or if the chemical had degraded over time to a lower concentration. As mentioned previously, each data file was analyzed manually for its specified chemical. This was done to ensure the most accurate analysis and incorporate expert opinions in cases of discrepancies regarding features like saturation, isomers, low abundances, and n-mer streaking (e.g., where unstable multimers break into monomers during instrumental analysis). However, this does introduce bias into the experiment.

Figure 5. Analysis of Chemical Stability and Amenability as Factors Influencing Detection.

Figure 5.

Donut plots show fractions of chemicals based on whether they were detected and their (A) stability, (B) amenability to detection with ESI[−], and (C) amenability for detection with ESI[+]. The total number of chemicals included in each analysis is shown at the center of each plot.

Conclusions

In this study, we utilized IMS-MS to develop a multidimensional database containing experimentally measured CCS and m/z values for 2,140 unique chemicals from the U.S. Environmental Protection Agency ToxCast program. The 4,685 chemicals evaluated covered thirteen classes including Natural Toxin (n=6), Disinfection By-Product (n=14), PFAS (n=17), Polycyclic Aromatic Hydrocarbon (PAH, n=31), Surfactant (n=78), Flame Retardant (n=120), Plastic (n=154), Color Dye (n=172), Cosmetic Ingredient (n=360), Pharmaceutical (n=615), Food Additive (n=634), Pesticide (n=948), and Chemical Industrial (n=1,536). To create the database, each chemical standard was assessed twice with ESI[+], ESI[−] and APCI[+] followed by IMS-MS analyses. Chemicals were then identified based on expected m/z values for [M+], [M+H]+, [M+Na]+ and [M−H] ion types. From these measurements, only chemicals having CCS values ≤1% error in the duplicate assessments were retained as high confidence identifications. This resulted in 2,140 unique chemical entries and 3,993 ion types. It was also noted that ESI[−] and ESI[+] worked for the largest majority of the chemicals, however APCI[+] covered a unique subset and provided value for certain chemical classes including the PAHs. Furthermore, comparison of the CCS database values with 6 other laboratories showed ~88% of the overlapping values were within 2% error, indicating interlaboratory reproducibility. Thus, new toxicant knowledge in this chemical library expands on our analytical capabilities and provides a tool for the scientific community to enable rapid IMS-MS screening of a wide range of xenobiotic chemicals, ultimately decreasing response time of exposure assessments and the ability to probe novel disease linkages.

Supplementary Material

Supplement 1
media-1.xlsx (1.8MB, xlsx)

Acknowledgements

This work was funded by a grant from the National Institute of Environmental Health Sciences (P42 ES027704) and a cooperative agreement with the Environmental Protection Agency (STAR RD 84003201). ELS acknowledges funding support from the Luxembourg National Research Fund (FNR) for project A18/BM/12341006. JZ, PAT, and EEB were supported by the National Center for Biotechnology Information of the National Library of Medicine (NLM), National Institutes of Health.

Footnotes

Competing Interests

The authors declare no competing financial interest.

References

  1. Aly N. A., Dodds J. N., Luo Y. S., Grimm F. A., Foster M., Rusyn I., and Baker E. S. (2022). Utilizing ion mobility spectrometry-mass spectrometry for the characterization and detection of persistent organic pollutants and their metabolites. Anal Bioanal Chem 414(3), 1245–1258. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Baker E. S., Clowers B. H., Li F., Tang K., Tolmachev A. V., Prior D. C., Belov M. E., and Smith R. D. (2007). Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures. J Am Soc Mass Spectrom 18(7), 1176–87. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Baker E. S., Hoang C., Uritboonthai W., Heyman H. M., Pratt B., MacCoss M., MacLean B., Plumb R., Aisporna A., and Siuzdak G. (2023). METLIN-CCS: an ion mobility spectrometry collision cross section database. Nat Methods 20(12), 1836–1837. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Barouki R., Audouze K., Becker C., Blaha L., Coumoul X., Karakitsios S., Klanova J., Miller G. W., Price E. J., and Sarigiannis D. (2022). The Exposome and Toxicology: A Win-Win Collaboration. Toxicol Sci 186(1), 1–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Belova L., Caballero-Casero N., van Nuijs A. L. N., and Covaci A. (2021). Ion Mobility-High-Resolution Mass Spectrometry (IM-HRMS) for the Analysis of Contaminants of Emerging Concern (CECs): Database Compilation and Application to Urine Samples. Anal Chem 93(16), 6428–6436. [DOI] [PubMed] [Google Scholar]
  6. Brack W., Ait-Aissa S., Burgess R. M., Busch W., Creusot N., Di Paolo C., Escher B. I., Mark Hewitt L., Hilscherova K., Hollender J., et al. (2016). Effect-directed analysis supporting monitoring of aquatic environments--An in-depth overview. Sci Total Environ 544, 1073–118. [DOI] [PubMed] [Google Scholar]
  7. Burnum-Johnson K. E., Zheng X., Dodds J. N., Ash J., Fourches D., Nicora C. D., Wendler J. P., Metz T. O., Waters K. M., Jansson J. K., et al. (2019). Ion Mobility Spectrometry and the Omics: Distinguishing Isomers, Molecular Classes and Contaminant Ions in Complex Samples. Trends Analyt Chem 116, 292–299. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Celma A., Sancho J. V., Schymanski E. L., Fabregat-Safont D., Ibanez M., Goshawk J., Barknowitz G., Hernandez F., and Bijlsma L. (2020). Improving Target and Suspect Screening High-Resolution Mass Spectrometry Workflows in Environmental Analysis by Ion Mobility Separation. Environ Sci Technol 54(23), 15120–15131. [DOI] [PubMed] [Google Scholar]
  9. Charest N., Lowe C. N., Ramsland C., Meyer B., Samano V., and Williams A. J. (2024). Improving predictions of compound amenability for liquid chromatography-mass spectrometry to enhance non-targeted analysis. Anal Bioanal Chem 416(10), 2565–2579. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Cordova A. C., Dodds J. N., Tsai H. D., Lloyd D. T., Roman-Hubers A. T., Wright F. A., Chiu W. A., McDonald T. J., Zhu R., Newman G., et al. (2023). Application of Ion Mobility Spectrometry-Mass Spectrometry for Compositional Characterization and Fingerprinting of a Library of Diverse Crude Oil Samples. Environ Toxicol Chem 42(11), 2336–2349. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Dodds J. N., and Baker E. S. (2019). Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead. J Am Soc Mass Spectrom 30(11), 2185–2195. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Dodds J. N., Hopkins Z. R., Knappe D. R. U., and Baker E. S. (2020). Rapid Characterization of Per- and Polyfluoroalkyl Substances (PFAS) by Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS). Anal Chem 92(6), 4427–4435. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Escher B. I., Hackermuller J., Polte T., Scholz S., Aigner A., Altenburger R., Bohme A., Bopp S. K., Brack W., Busch W., et al. (2017). From the exposome to mechanistic understanding of chemical-induced adverse effects. Environ Int 99, 97–106. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Escher B. I., Stapleton H. M., and Schymanski E. L. (2020). Tracking complex mixtures of chemicals in our changing environment. Science 367(6476), 388–392. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Ewing M. A., Glover M. S., and Clemmer D. E. (2016). Hybrid ion mobility and mass spectrometry as a separation tool. J Chromatogr A 1439, 3–25. [DOI] [PubMed] [Google Scholar]
  16. Foster M., Rainey M., Watson C., Dodds J. N., Kirkwood K. I., Fernandez F. M., and Baker E. S. (2022). Uncovering PFAS and Other Xenobiotics in the Dark Metabolome Using Ion Mobility Spectrometry, Mass Defect Analysis, and Machine Learning. Environ Sci Technol doi: 10.1021/acs.est.2c00201. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Gabelica V., Shvartsburg A. A., Afonso C., Barran P., Benesch J. L. P., Bleiholder C., Bowers M. T., Bilbao A., Bush M. F., Campbell J. L., et al. (2019). Recommendations for reporting ion mobility Mass Spectrometry measurements. Mass Spectrom Rev 38(3), 291–320. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. GraphPad (2024). KNOWLEDGEBASE - ARTICLE #591: Statistics with n=2. Available at: https://www.graphpad.com/support/faqid/591/.
  19. Hinnenkamp V., Klein J., Meckelmann S. W., Balsaa P., Schmidt T. C., and Schmitz O. J. (2018). Comparison of CCS Values Determined by Traveling Wave Ion Mobility Mass Spectrometry and Drift Tube Ion Mobility Mass Spectrometry. Anal Chem 90(20), 12042–12050. [DOI] [PubMed] [Google Scholar]
  20. Ibrahim Y. M., Baker E. S., Danielson W. F. 3rd, Norheim R. V., Prior D. C., Anderson G. A., Belov M. E., and Smith R. D. (2015). Development of a New Ion Mobility (Quadrupole) Time-of-Flight Mass Spectrometer. Int J Mass Spectrom 377, 655–662. [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Ibrahim Y. M., Garimella S. V., Prost S. A., Wojcik R., Norheim R. V., Baker E. S., Rusyn I., and Smith R. D. (2016). Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform. Anal Chem 88(24), 12152–12160. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Jurneczko E., Kalapothakis J., Campuzano I. D., Morris M., and Barran P. E. (2012). Effects of drift gas on collision cross sections of a protein standard in linear drift tube and traveling wave ion mobility mass spectrometry. Anal Chem 84(20), 8524–31. [DOI] [PubMed] [Google Scholar]
  23. Kanu A. B., Dwivedi P., Tam M., Matz L., and Hill H. H. (2008). Ion mobility-mass spectrometry. Journal of Mass Spectrometry 43(1), 1–22. [DOI] [PubMed] [Google Scholar]
  24. Kirkwood-Donelson K. I., Dodds J. N., Schnetzer A., Hall N., and Baker E. S. (2023). Uncovering per- and polyfluoroalkyl substances (PFAS) with nontargeted ion mobility spectrometry-mass spectrometry analyses. Sci Adv 9(43), eadj7048. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Lai Y., Koelmel J. P., Walker D. I., Price E. J., Papazian S., Manz K. E., Castilla-Fernandez D., Bowden J. A., Nikiforov V., David A., et al. (2024). High-Resolution Mass Spectrometry for Human Exposomics: Expanding Chemical Space Coverage. Environ Sci Technol 58(29), 12784–12822. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Lowe C. N., Isaacs K. K., McEachran A., Grulke C. M., Sobus J. R., Ulrich E. M., Richard A., Chao A., Wambaugh J., and Williams A. J. (2021). Predicting compound amenability with liquid chromatography-mass spectrometry to improve non-targeted analysis. Anal Bioanal Chem 413(30), 7495–7508. [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Luo Y. S., Aly N. A., McCord J., Strynar M. J., Chiu W. A., Dodds J. N., Baker E. S., and Rusyn I. (2020). Rapid Characterization of Emerging Per- and Polyfluoroalkyl Substances in Aqueous Film-Forming Foams Using Ion Mobility Spectrometry-Mass Spectrometry. Environ Sci Technol 54(23), 15024–15034. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Luo Y. S., Chen Z., Blanchette A. D., Zhou Y. H., Wright F. A., Baker E. S., Chiu W. A., and Rusyn I. (2021). Relationships between constituents of energy drinks and beating parameters in human induced pluripotent stem cell (iPSC)-Derived cardiomyocytes. Food Chem Toxicol 149, 111979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. May J. C., and McLean J. A. (2015). Ion mobility-mass spectrometry: time-dispersive instrumentation. Anal Chem 87(3), 1422–36. [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. May J. C., Morris C. B., and McLean J. A. (2017). Ion Mobility Collision Cross Section Compendium. Anal Chem 89(2), 1032–1044. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Metz T. O., Baker E. S., Schymanski E. L., Renslow R. S., Thomas D. G., Causon T. J., Webb I. K., Hann S., Smith R. D., and Teeguarden J. G. (2017). Integrating ion mobility spectrometry into mass spectrometry-based exposome measurements: what can it add and how far can it go? Bioanalysis 9(1), 81–98. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Phillips A. L., Williams A. J., Sobus J. R., Ulrich E. M., Gundersen J., Langlois-Miller C., and Newton S. R. (2022). A Framework for Utilizing High-Resolution Mass Spectrometry and Nontargeted Analysis in Rapid Response and Emergency Situations. Environ Toxicol Chem 41(5), 1117–1130. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Picache J. A., Rose B. S., Balinski A., Leaptrot K. L., Sherrod S. D., May J. C., and McLean J. A. (2019). Collision cross section compendium to annotate and predict multi-omic compound identities. Chem Sci 10(4), 983–993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Richard A. M., Huang R., Waidyanatha S., Shinn P., Collins B. J., Thillainadarajah I., Grulke C. M., Williams A. J., Lougee R. R., Judson R. S., et al. (2021). The Tox21 10K Compound Library: Collaborative Chemistry Advancing Toxicology. Chem Res Toxicol 34(2), 189–216. [DOI] [PMC free article] [PubMed] [Google Scholar]
  35. Richard A. M., Judson R. S., Houck K. A., Grulke C. M., Volarath P., Thillainadarajah I., Yang C., Rathman J., Martin M. T., Wambaugh J. F., et al. (2016). ToxCast Chemical Landscape: Paving the Road to 21st Century Toxicology. Chem Res Toxicol 29(8), 1225–51. [DOI] [PubMed] [Google Scholar]
  36. Richard A. M., Tao D., LeClair C. A., Leister W., Tretyakov K. V., White V E., Lewis K. C., Sefler A., Shinn P., Collins B. J., et al. (2024). Analytical Quality Evaluation of the Tox21 Compound Library (submitted). [DOI] [PMC free article] [PubMed] [Google Scholar]
  37. Richard A. M., Truong H., Wolf M., and Thillainadarajah I. (2014). ToxCast Chemical Inventory: Data Management & Data Quality Considerations. In (N. C. f. C. T. (NCCT), Ed.). U.S. Environmental Protection Agency, Office of Research & Development, Research Triangle Park, NC. [Google Scholar]
  38. Roman-Hubers A. T., Aeppli C., Dodds J. N., Baker E. S., McFarlin K. M., Letinski D. J., Zhao L., Mitchell D. A., Parkerton T. F., Prince R. C., et al. (2022a). Temporal chemical composition changes in water below a crude oil slick irradiated with natural sunlight. Mar Pollut Bull 185(Pt B), 114360. [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Roman-Hubers A. T., Cordova A. C., Rohde A. M., Chiu W. A., McDonald T. J., Wright F. A., Dodds J. N., Baker E. S., and Rusyn I. (2022b). Characterization of Compositional Variability in Petroleum Substances. Fuel 317, 123547. [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Scholz S., Nichols J. W., Escher B. I., Ankley G. T., Altenburger R., Blackwell B., Brack W., Burkhard L., Collette T. W., Doering J. A., et al. (2022). The Eco-Exposome Concept: Supporting an Integrated Assessment of Mixtures of Environmental Chemicals. Environ Toxicol Chem 41(1), 30–45. [DOI] [PMC free article] [PubMed] [Google Scholar]
  41. Stow S. M., Causon T. J., Zheng X., Kurulugama R. T., Mairinger T., May J. C., Rennie E. E., Baker E. S., Smith R. D., McLean J. A., et al. (2017). An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements. Anal Chem 89(17), 9048–9055. [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Ulrich E. M., Sobus J. R., Grulke C. M., Richard A. M., Newton S. R., Strynar M. J., Mansouri K., and Williams A. J. (2019). EPA’s non-targeted analysis collaborative trial (ENTACT): genesis, design, and initial findings. Anal Bioanal Chem 411(4), 853–866. [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Valdiviezo A., Aly N. A., Luo Y. S., Cordova A., Casillas G., Foster M., Baker E. S., and Rusyn I. (2022). Analysis of per- and polyfluoroalkyl substances in Houston Ship Channel and Galveston Bay following a large-scale industrial fire using ion-mobility-spectrometry-mass spectrometry. J Environ Sci (China) 115, 350–362. [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Valdiviezo A., Luo Y. S., Chen Z., Chiu W. A., and Rusyn I. (2021). Quantitative In Vitro-to-In Vivo Extrapolation for Mixtures: A Case Study of Superfund Priority List Pesticides. Toxicol Sci 183(1), 60–69. [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Vermeulen R., Schymanski E. L., Barabasi A. L., and Miller G. W. (2020). The exposome and health: Where chemistry meets biology. Science 367(6476), 392–396. [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Wambaugh J. F., Hughes M. F., Ring C. L., MacMillan D. K., Ford J., Fennell T. R., Black S. R., Snyder R. W., Sipes N. S., Wetmore B. A., et al. (2018). Evaluating In Vitro-In Vivo Extrapolation of Toxicokinetics. Toxicol Sci 163(1), 152–169. [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Wambaugh J. F., Wetmore B. A., Ring C. L., Nicolas C. I., Pearce R. G., Honda G. S., Dinallo R., Angus D., Gilbert J., Sierra T., et al. (2019). Assessing Toxicokinetic Uncertainty and Variability in Risk Prioritization. Toxicol Sci 172(2), 235–251. [DOI] [PMC free article] [PubMed] [Google Scholar]
  48. Williams A. J., Grulke C. M., Edwards J., McEachran A. D., Mansouri K., Baker N. C., Patlewicz G., Shah I., Wambaugh J. F., Judson R. S., et al. (2017). The CompTox Chemistry Dashboard: a community data resource for environmental chemistry. J Cheminform 9(1), 61. [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Zhang X., Romm M., Zheng X., Zink E. M., Kim Y. M., Burnum-Johnson K. E., Orton D. J., Apffel A., Ibrahim Y. M., Monroe M. E., et al. (2016). SPE-IMS-MS: An automated platform for sub-sixty second surveillance of endogenous metabolites and xenobiotics in biofluids. Clin Mass Spectrom 2, 1–10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Zheng X., Aly N. A., Zhou Y., Dupuis K. T., Bilbao A., Paurus V. L., Orton D. J., Wilson R., Payne S. H., Smith R. D., et al. (2017). A structural examination and collision cross section database for over 500 metabolites and xenobiotics using drift tube ion mobility spectrometry. Chem Sci 8(11), 7724–7736. [DOI] [PMC free article] [PubMed] [Google Scholar]
  51. Zheng X., Dupuis K. T., Aly N. A., Zhou Y., Smith F. B., Tang K., Smith R. D., and Baker E. S. (2018). Utilizing ion mobility spectrometry and mass spectrometry for the analysis of polycyclic aromatic hydrocarbons, polychlorinated biphenyls, polybrominated diphenyl ethers and their metabolites. Anal Chim Acta 1037, 265–273. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplement 1
media-1.xlsx (1.8MB, xlsx)

Articles from bioRxiv are provided here courtesy of Cold Spring Harbor Laboratory Preprints

RESOURCES