Table 6.
EE calculation data for manufacturing of the developed SDET.
| S. no. | Component | Material | EE | Weight | Total EE, kWh | References |
|---|---|---|---|---|---|---|
| 1 | Drying room | Wood | 2.0 kWh/kg | 15 kg | 30.0 | 92 |
| 2 | Hinges | Metal | 8.89 kWh/kg | 0.1 kg | 0.889 | 93 |
| 3 | Handel | Metal | 8.89 kWh/kg | 0.1 kg | 0.889 | 93 |
| 4 | Drying trays | Metal | 8.89 kWh/kg | 2.0 kg | 17.72 | 93 |
| 5 | Evacuated tubes | – | 1138.52 kWh/tube | 4 tubes | 4552 | 94 |
| 6 | Air circulation fan | |||||
| (i) Copper wire | Copper | 19.61 kWh/kg | 0.2 kg | 3.922 | 93 | |
| (ii) Casings, fan, shaft etc | Steel | 8.89 kWh/kg | 0.2 kg | 1.778 | 93 | |
| Total EE, kWh | 4607.198 | |||||