Skip to main content
. 2023 Jul;64(7):1145–1153. doi: 10.2967/jnumed.122.265362

TABLE 3.

Organ Motion Evaluation Due to Respiration Before and After Motion Correction for Different Tracer Studies Using Absolute Average Distance Between Liver Dome in Reference Frame and Liver Dome in All Other Frames

PET/CT system Tracer Absolute average distance (mm) P
Before motion correction After motion correction
uEXPLORER 18F-FDG 2.7 ± 1.9 (0.0–6.9) 0 (0) <0.01
uEXPLORER 18F-fluciclovine 4.2 ± 3.9 (0.7–14) 0.3 ± 0.4 (0.0–1.3) <0.01
uEXPLORER 68Ga-DOTATATE 3.3 ± 1.6 (1.0–7.0) 0 (0) <0.01
Biograph Vision 600 18F-FDG 5.3 ± 1.7 (1.6–8.4) 1.2 ± 0.5 (0.4–2.0) <0.01
Biograph Vision 600 68Ga-PSMA 4.8 ± 2.1 (0.9–8.3) 0.6 ± 0.5 (0.0–1.1) <0.01
Biograph Vision 600 11C-PIB 1.3 ± 1.0 (0.0–2.0) 0 (0) <0.1

Data in parentheses are range.