Abstract
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non‐invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher SNR and spatial resolution compared to in vivo studies, and enabling more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage of ex vivo dMRI is the direct comparison with histological data, as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging of small animals, but ultimately affect what questions can be answered using the data. This work represents “Part 2” of a three‐part series of recommendations and considerations for preclinical dMRI. We describe best practices for dMRI of ex vivo tissue, with a focus on the value that ex vivo imaging adds to the field of dMRI and considerations in ex vivo image acquisition. We first give general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in specimens and models and discuss why some may be more or less appropriate for different studies. We then give guidelines for ex vivo protocols, including tissue fixation, sample preparation, and MR scanning. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist (and why), and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
Keywords: acquisition, best practices, diffusion MRI, diffusion tensor, ex vivo, microstructure, open science, preclinical, processing, tractography
1. INTRODUCTION
Diffusion MRI (dMRI) is a medical imaging technique that utilizes the diffusion of water molecules to generate image contrast, enabling the non‐invasive mapping of the diffusion process in biological tissues. These diffusion patterns can be used to infer and generate maps of tissue microstructure or can be applied to map tissue orientation to study the structural connections of the brain in a process called fiber tractography. They have found applications widely used in neuroscience, neuroanatomy, and neurology, but also outside the brain with musculoskeletal, whole‐body, and organ‐specific applications in normal and pathological conditions.
Much like any biomedical research, the use of animal models and ex vivo tissue is essential to the field of diffusion MRI. In this work, we define small animal imaging as imaging performed on a living animal model of human tissue, whereas ex vivo we define as covering any fresh excised tissue, perfused living tissue, or fixed tissue. Small‐animal research is highly valuable for investigating the biology, etiology, progression, and treatment of disease; for the field of dMRI specifically, preclinical imaging is essential for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. While dMRI enables non‐invasive characterization of tissue in vivo, ex vivo acquisitions are increasingly being used to probe tissue properties and brain connectivity. Diffusion MRI of ex vivo tissue has several experimental advantages, including longer scanning times and absence of motion. Together, these make it possible to acquire data with high SNR at a much higher resolution compared to in vivo studies, and with sophisticated diffusion contrasts which may enable better characterization of microstructure and connectivity. Another advantage afforded by ex vivo dMRI is the ability to compare diffusion data to histological data, bridging the gap between in vivo and histology for methodological validation. Because of these advantages, there have been an increasing number of dMRI studies on ex vivo tissue samples.
However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging of small animals, but ultimately affect what questions can be answered using the data. This work represents “Part 2” of a three‐part series of recommendations and considerations for preclinical dMRI. Part 1 covers in vivo small animal imaging. 1 Here, Part 2 presents general considerations and best practices for preclinical dMRI acquisition of ex vivo tissue. Finally, Part 3 covers ex vivo data processing, tractography, and comparisons with histology. 2 This work does not serve as a “consensus” on any specific topic, but rather as a snapshot of “best practices” or “guidance” from the preclinical dMRI community as represented by the authors. We envision this work to be useful to imaging centers using small animal scanners for research, sites that may not have personnel with expert knowledge in diffusion, pharmaceutical or industry employees, or new trainees in the field of dMRI. The resources provided herein may act as a starting point when reading the literature and understanding the decisions and processes for studying model systems with dMRI.
We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in specimens and models and discuss why some may be more or less appropriate for different studies. We then provide guidance for ex vivo acquisition protocols, including decisions on hardware, sample preparation, and imaging sequences. In each section, we attempt to also highlight areas for which no guidelines exist (and why), and where future work should lie. With this, we hope to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
2. ADDED VALUE
Ex vivo samples add substantial value to dMRI by acting as supplements, substitutes, translations, and/or validation mechanisms for in vivo human studies. Building on the four areas identified in Part 1 in which preclinical MRI adds value to the field of diffusion MRI, here we focus on aspects specific to ex vivo experiments (Figure 1).
FIGURE 1.

Four areas in which preclinical brain imaging adds value to the field of dMRI. It enables: (i) correlation with histology on the same subject/sample, (ii) the acquisition of richer datasets than on clinical systems thanks to more advanced hardware and longer scan times available, (iii) the study of tissue changes with disease and treatment in a more controlled setting, and (iv) comparative anatomy between species. Figures reused and adapted from (left to right): (i), 3 , 4 , 5 (ii), 6 , 7 , 8 (iii), 9 , 10 (iv). 11
First, ex vivo dMRI allows correlations with histological and other imaging measures in a more direct way than in vivo dMRI, since the tissue has undergone similar changes related to fixation and other chemical treatments. Through co‐registration of microscopy images to MRI images of the same specimens, direct comparisons and correlation of dMRI measures to different quantitative microscopic parameters can be achieved, thus elucidating how different microscopic tissue features influence dMRI contrast. Such validation studies in turn improve our ability to interpret in vivo dMRI for both preclinical and clinical studies.
Second, ex vivo imaging allows acquisition of “extreme” datasets not possible with in vivo preclinical or clinical imaging, pushing the boundaries of acquisition and analysis to answer questions about what dMRI is capable of measuring in principle. By “extreme” datasets, we target in particular: advanced diffusion encoding, higher b‐values, shorter diffusion times, or very comprehensive q‐t coverage, all with high SNR and/or high spatial resolution that requires very long scan times. Preclinical MRI systems indeed offer four distinct advantages for imaging. First, the appeal of higher fields is driven by benefits of potentially higher SNR due to increased net magnetization. Second, ex vivo imaging allows more flexibility in RF coils, which can be in close proximity to the sample being imaged, further increasing SNR. Third, stronger and faster switching gradients are also an immense asset for dMRI experiments, 12 enabling a higher SNR via reduced TE. Stronger gradients facilitate the exploration of broader ranges of diffusion sensitization and diffusion time (i.e., “q‐t space”) while keeping an acceptable SNR level. In particular, unique insights into tissue microstructure have been brought by exploring a range of q‐t space only feasible (at the time) on preclinical systems, 13 , 14 , 15 , 16 , 17 including very short diffusion times, very strong diffusion weightings 4 , 13 , 14 , 15 , 16 , 18 , 19 ; or more complex diffusion encoding schemes. 20 , 21 , 22 Finally, the greatest asset enabled by ex vivo imaging is a lengthy scan time, ranging from several hours to successful scans of >10 days in duration, with the added benefit of no physiological motion. Long scanning further facilitates acquisitions across q‐t ranges, with substantially increased SNR and/or increased spatial resolution.
Third, the use of animal models allows us to study the sensitivity of dMRI to tissue changes in diseases, disorders and treatments in a controlled way. Animal models are critical to biomedical research as they may be biologically similar to humans, susceptible to many of the same health problems, and can be studied throughout their whole life span and across generations. Ex vivo imaging has the added benefit of bridging the gap between in vivo imaging and histology (Added Value #1) of such models, and investigation of new imaging sequences (Added Value #2) that together spur development and validation of new biomarkers for diagnosis and treatment.
Fourth, the use of ex vivo systems enables comparative anatomy. A key challenge in comparative neuroanatomy is to identify homologous structures and structural boundaries across species. Moreover, the brain undergoes substantial changes through development and aging which hampers comparison of data from different timepoints. High‐resolution ex vivo structural MRI and dMRI data have provided versatile reference data for creating anatomical atlases for fly, mouse, rat, primate, and even bat brains 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 allowing detection of detailed anatomical systems corresponding to those identified using histological criteria. 31 , 32 Comparative neuroanatomical efforts, then, may rely on histological comparisons across species supplemented by high quality imaging acquisitions as a marker of “virtual histology” and “virtual brain dissection”.
3. EX VIVO: TRANSLATION AND VALIDATION CONSIDERATIONS
Similar to in vivo studies of small animals, scanning ex vivo tissue presents both opportunities and challenges when translating and validating experimental findings. 33 This section introduces experimental and biological aspects that must be considered when designing and interpreting ex vivo studies. All aspects are covered in more detail in their corresponding sub‐sections in Acquisition (Section 4).
3.1. Anatomical considerations
The basic constituents of the brain and other organs are largely preserved across mammalian species, providing the basis for translational MRI studies. Moreover, the constituents and organization of ex vivo tissue are largely similar to their in vivo counterparts, assuming appropriate perfusion fixation (to preserve “dead” tissue) or artificial perfusion (to preserve “viable” ex vivo tissue). 34 , 35 For example, in the central nervous system, the fundamental structure of a long axon wrapped with a myelin sheath is preserved with chemical fixation ex vivo. Noticeable exceptions to similarity are possible changes in size, volume fractions of tissue compartments, membrane permeability, and/or diffusivity drop beyond those that are expected from temperature changes (see Considerations of microstructure and the diffusion process, below). 36 , 37
3.2. Considerations in disease/disorder/model
As in small animal studies, a challenge when using ex vivo data to study the sensitivity of dMRI to detect changes in disease or treatments is confirming the translational value to human studies. Despite this, ex vivo imaging of models of stroke, demyelination, traumatic brain injury, spinal cord injury, and tumor models have proven useful to investigate altered microstructure or connectivity in diseased states, and facilitate subsequent histological validation. 38 Clearly, the advantage of small animal imaging for longitudinal studies of development or disease progression in single subjects stops at the ex vivo scan, yet the benefits of the high resolution and high SNR scan enable detailed investigations of the ex vivo tissue at one specific time point. This is often taken advantage of through a cross‐sectional or partially longitudinal experimental design where (subsets of) animals are sacrificed at different timepoints to enable validation using histology.
3.3. Considerations of microstructure and the diffusion process
The translation of ex vivo measurements to in vivo should be interpreted with caution, as both the tissue microstructure and intrinsic diffusivities may be different (Figure 2). To prevent post‐mortem degradation and to limit uncontrolled changes in tissue microstructure, tissues should be chemically fixed. Nevertheless, even using appropriate chemical fixation, the tissue inevitably undergoes changes: so far intra‐/extracellular space volume fraction shifts, cell membrane permeability, relaxation rates, and diffusion coefficients have all been shown to change. 36 , 37 , 39 , 40 , 41 The degree to which fixation affects microstructure features is however variable across the literature—see Section 4.3 for details. Ex vivo dMRI on fixed tissue at room temperature also distinguishes itself through lower diffusivity by a factor of 2–5 in the tissue, which cannot be explained by the difference in temperature alone, but is also due to fixation and/or other post‐mortem tissue changes. 42 These effects should all be considered when designing the scanning protocol, and should be considered also when interpreting results in terms of diffusion distance and probed spatial scales (Section 4.5.3). Lastly, strategies for mitigating and/or correcting temporal drift are described throughout, and may involve sample preparation (Section 4.4), controlling temperature during scanning (Section 4.5.4) and within preprocessing pipelines (Part 3; Section 2).
FIGURE 2.

Considerations in the diffusion process. When performing studies on ex vivo tissue, one must consider effects of (i) chemical fixation (changes in geometry, volume fractions, relaxation rates, permeability, diffusion coefficients), (ii) changes in diffusivity (which can be approximally two to five times reduced from in vivo depending on experimental conditions), and (iii) temporal instabilities over long scan times (causing temporal drift or image artifacts). Figures reused and adapted from (i), 37 (ii), 43 , 44 (iii). 45 , 46
These effects need to be considered when interpreting in vivo dMRI based on ex vivo validation studies. A diffusion biophysical model that is validated or performs well ex vivo may not be valid/validated in vivo, and vice‐versa, due to modeling assumptions, and potential differences in diffusivities, compartmental volume fractions, and relaxation rates.
3.4. Species differences
Diffusion MRI has been utilized in a number of animal models, both in vivo and ex vivo. The most appropriate species to investigate is ultimately dependent upon the research question. Of course, in studies of human anatomy, the post‐mortem human brain can also be imaged and subsequently dissected, or sectioned for histological analysis. Additionally improved SNR can be achieved and traded for spatial resolution by dissecting and imaging just the fragment of interest from the whole sample, thus allowing the use of smaller‐bore, higher‐magnetic field systems, and smaller RF coils.
Below, we list some of the most common species (and a few avantgarde ones) studied with ex vivo dMRI and briefly describe advantages and disadvantages of each.
3.4.1. Murine models (mouse and rat)
Rats and mice have been and continue to be the long‐standing preferred species for biomedical research models as they offer a low‐cost option with outcome measures widely available and a substantial database of normative data, including behavioral, genomic, and medical imaging (Figure 3). In addition to biological advantages, the small physical size offers technical advantages, fitting in the typically smaller bores (and smaller coils) of magnets with larger field strengths. This is particularly advantageous for ex vivo imaging, where the small size may facilitate scanning with smaller bore ultra‐high field scanners and smaller volume coils or cryogenic probes. Ex vivo, mouse and rat models have found most applications in exploration and development of advanced image acquisition and diffusion encoding, and validation of multi‐compartment modeling facilitated through subsequent histology.
FIGURE 3.

Ex vivo imaging of mouse models facilitates high resolution, high SNR, dense sampling of q‐t space. Here, a fixed mouse brain was imaged on a 16.4T Bruker Eon Ascend scanner equipped with a 10‐mm birdcage coil and gradients capable of producing up to 3 T/m in all directions. Images show mean diffusivity (MD), mean kurtosis (MK), and directionally encoded color (DEC) fractional anisotropy (FA) maps. 47 All animal studies were approved by the competent institutional and national authorities and performed according to European Directive 2010/63. Images kindly provided by Andrada Ianus and Noam Shemesh.
3.4.2. Primate models
Popular non‐human primates (NHPs) in dMRI literature include marmosets, squirrel monkeys, and macaques. With a number of white matter and gray matter regions with homologous counterparts in humans, 48 , 49 , 50 , 51 NHPs are well suited for studies of cortical development, gyrification, and the structural and functional significance of specific white matter pathways. Ex vivo NHP imaging, in particular, is very common after injection of histological tracers, and constitutes a majority of diffusion tractography validation studies (Figure 4). This enables comparisons of tracers to exceptional quality diffusion datasets, in order to identify challenges and limitations in diffusion tractography. For example, controversies regarding the existence or nonexistence of a pathway, or the location of pathway terminations have been resolved or steered through primate models. 52 , 53 , 54 , 55
FIGURE 4.

Primate models have been used to validate tractography estimates of structural connectivity. Ex vivo imaging offers the ability to investigate and compare the anatomical accuracy of high quality and high resolution dMRI datasets against histological tracers, the gold‐standard for elucidating brain tractography. Figure adapted from 56 and, 57 based on ex vivo macaque data acquired by 58 shows tracer trajectory (left), directionally encoded color map (middle), and tractography streamlines (right).
3.4.3. Human models
Ex vivo imaging of human brains is also possible (Figure 5). Of course, the greatest advantage is the immediate translatability to the in vivo human brain. Because of the high resolution and rich (q‐t) space coverage, ex vivo dMRI of the human brain has found a number of neuroanatomical applications 59 including validation of orientation estimates and tractography, 60 , 61 , 62 , 63 mapping of subcortical structures and creation of high resolution atlases and templates, 6 , 64 , 65 and investigation of deep or cortical gray matter laminar structures. 45 , 66 , 67 , 68 Challenges that are specific to human brain samples include limitations to medium‐to‐large bore systems (that often do not have specialized hardware such as strong gradient sets), and the need for specific sample holders or coils, although small sub‐sections of human brains have also been scanned. Additionally, high quality scans are only possible on well‐preserved samples, whereby minimizing the post‐mortem interval between death and fixation is a necessity (see Section 4.3 Fixation for detailed discussion of the effects of post‐mortem interval on MR‐relevant tissue features).
FIGURE 5.

Ex vivo imaging of the human brain facilitates high resolution and high SNR dMRI (left), which offers exceptional tractography, mapping and creation of templates for small structures, and investigation of gray matter laminar structures (right). Images adapted from. 69
3.4.4. Other models
Several other models beyond murine and NHP have proven useful to the diffusion community. Examples include the pig brain, which has been used with ex vivo dMRI for tractography validation, 70 , 71 , 72 and even to optimize strategies for ex vivo diffusion acquisitions. 45 Other gyrencephalic brains have been used ex vivo to study diseases or to validate tractography include ferrets, 73 , 74 , 75 sheep, 76 , 77 , 78 dogs, 79 and cats. 80 One study scanned 123 mammalian species, with brains ranging in size from 0.1 to 1000 mL, to study the evolution of mammalian brain connectivity. 81
Further, various non‐human models of white matter, including cat optic nerves, rabbit peripheral nerves, garfish olfactory nerves, and lobster nerves and spinal cords were used to evaluate sources of anisotropy, and attribute and associate microstructural features to not only anisotropy, but restricted and hindered diffusion, compartmental diffusivities, and insight into pathology. 82 , 83 Moreover, the simple nervous system with very large neurons of Aplysia, a sea slug, has been used to study the relationship between the cellular structure and the diffusion MRI signal, to characterize compartment‐specific diffusion properties and to follow diffusion changes induced by neuronal responses to ischemic‐like stress or chemical stimulation. 84 , 85 , 86 , 87 , 88
In general, dMRI studies of perfused viable tissue or cells present different advantages and/or challenges as compared to chemically fixed tissue. As mentioned above, isolated perfused “live” tissue samples facilitate well controlled perturbation studies, 88 , 89 for example, controllably changing perfusate tonicity to induce cell swelling/shrinkage to model tissue alterations in stroke. 90 , 91 Furthermore, the estimation of relative compartment sizes can also be thoroughly explored by controlling tonicity, 92 especially since, without fixative, the tissue does not shrink.
4. ACQUISITION
4.1. Standard protocol: overview
Here, we provide recommendations (Figure 6) for (1) selecting appropriate hardware including MRI systems and coils (Section 4.2), (2) chemical fixation (Section 4.3), (3) sample preparation including washing, constraint and holders, possible contrast enhancements, and immersion solutions (Section 4.4), (4) MR scanning including diffusion encoding, readouts, q‐t coverage, spatial resolution, and monitoring (Section 4.5), and (5) long‐term sample storage (Section 4.6).
FIGURE 6.

For high‐quality ex vivo diffusion MRI, decisions regarding hardware, fixation, preparation, MR scanning, and tissue storage must be carefully considered. Hardware: Utilize the smallest coil that fits the sample under investigation, to maximize SNR. Fixation: For ex vivo tissue to be a good model of in vivo, the post‐mortem interval to fixation must be as short as possible. Preparation: Washing out fixative and soaking tissue in a solution of Gadolinium‐based contrast agent decreases primarily water‐protons T1 which in turn allows for a favorable trade‐off between SNR maximization and TR reduction (i.e., reduced acquisition time), while a robust physical setup eliminates motion during scanning. MR Scanning: A multi‐shot 3D diffusion‐weighted spin echo EPI or multi‐shot 3D diffusion‐weighted RARE/FSE sequence. While not typically used in vivo due to motion sensitivity and long scan time, these sequences combine advantages of high SNR, minimal distortion, and reasonable scan time ex vivo. Storage: Fixed tissue can be stored for many months to several years if stored in fixative or phosphate buffered solution (often with 1% paraformaldehyde [PFA]) at 5°C.
4.2. Hardware (species/organ specific)
Most investigators are limited to the use of hardware available at their imaging center. The guidelines for ex vivo imaging largely follow those suggested for small animal imaging in Part 1. 1 For RF coils, the general recommendation is to utilize a coil that will maximize SNR for the sample of interest, which will typically be the smallest coil that fits the sample under investigation. For ex vivo in particular, this is often a volume coil for both excitation and reception, as we typically desire (and have time for) covering the entire sample with the scan FOV, and volume coils have more homogeneous excitation/reception profiles than surface coils. Nevertheless, surface coils for reception can offer higher local SNR so the choice of coil setup depends on the imaging task.
If several MRI systems are available, a recommendation is to select the scanner with the strongest and fastest gradients, highest field strength, that has a bore and appropriate coil that is large enough for the sample to be imaged. Higher static magnetic field strengths provide higher SNR, but are challenged by changes in relaxation rates, for example increases in T1 93 and decreased T2 94 (see Sample Preparation (Section 4.4 ) for discussion on techniques to alter both longitudinal and transverse relaxation, and see MR Scanning: Readout (Section 4.5.2) for discussion on taking advantage of altered relaxation rates).
4.3. Fixation
After death, tissues begin a self‐degeneration process called autolysis, due to their own autogenous enzymes. This process degrades tissue quality, potentially altering several of the microstructural features we wish to quantify and/or validate against. Chemical fixation stops autolytic processes and preserves tissue structure by cross‐linking proteins. 95 The post‐mortem interval (PMI), i.e., the time between death and chemical fixation, is crucial for tissue quality. Anatomical and radiological signs of autolysis, such as myelin loosening, decreased anisotropy and decreased diffusivities, may be observed as rapidly as four to 6 h post‐mortem, dependent upon tissue temperature, and continue to be altered with longer times between death and fixation. 37 , 95 , 96 Thus, rapid tissue fixation is recommended to maintain its integrity.
For laboratory animals, the method of choice is intracardiac perfusion fixation, which consists of using the intact vascular system to flush fixatives throughout the tissue upon animal sacrifice. This comes with the advantage of a mostly homogenized fixative distribution throughout the tissues and an efficient removal of blood by flushing with heparin‐containing phosphate buffered saline (PBS) prior to perfusion with fixative. For human tissues or in the case where perfusion‐fixation is not possible for animals, perfusion fixation can sometimes be performed on post‐mortem brain tissue using mechanical means. 59 , 97 In an optimal case, a syringe would be inserted into the femoral artery of a non‐refrigerated (refrigeration introduces MRI artifacts) cadaver after a short PMI, via which mannitol 20% (wash step) and subsequently a fixative are pumped at a low pressure to avoid microstructural damage.
Alternatively, tissue may be immersion‐fixed, i.e., immersed in a fixative solution where fixative will passively diffuse throughout the tissue over a period of time (estimated at ˜1 mm/hr at 25°C, 95 or longer for refrigerated samples). For example, at least 20 days are needed for enough formaldehyde to diffuse to the core of a human brain to cause fixation (Dawe et al. 2009). Other tissue types may require different fixation durations, since the diffusion dynamics of the fixative solution are not the same as for the brain (e.g., 124 days for 4% formaldehyde to penetrate 30 mm into the whole human spleen, and 62 days for the fixative to diffuse over the same distance into mammalian liver tissue) (Dawe et al. 2009). As a major pitfall, immersion fixation introduces the risk of autolytic effects and microbial degradation 98 due to the PMI and/or delay in penetration of deep tissue in larger samples. 99 As autolytic processes are temperature dependent, refrigerating the tissue as soon as possible after death, and during immersion fixation is recommended. Furthermore, this technique yields a transient concentration gradient of the fixative, and hence spatially inhomogeneous tissue integrity with varying MR characteristics (e.g., apparent T1 and T2). As a result, immersion fixed samples may exhibit lower anisotropy and diffusivity than their perfusion‐fixed counterparts, in which case the differences may correlate with tissue degeneration. A rule of thumb to check the quality of fixed tissue (perfusion and immersion fixed) is that FA values should be the same as in vivo, e.g., as measured in the midsagittal corpus callosum. Nonetheless, immersion fixation holds the advantage of not relying on an intact vascular system, such that the most peripheral parts of the tissue can undergo good fixation even in the case of clogged blood vessels and/or trauma. Furthermore, perfusion‐fixed tissues may additionally be post‐fixed through the immersion process as well, often in a different concentration of the fixative.
In brief, we recommend minimizing the PMI to minimize autolytic changes in the tissue, refrigerating samples before and during immersion fixation and, whenever possible, sacrificing the animals using perfusion‐fixation, which practically reduces the PMI to zero. For samples where perfusion fixation of the tissue is not possible (e.g., human brain samples) the recommendation is to keep PMI as constant as possible across samples and to state the PMI when reporting methods and results.
There are a number of fixatives to choose from, the most common being formaldehyde. For an overview of formaldehyde fixatives, see Refs. 100, 101. Notably, the type and concentration of fixative can have a considerable impact on tissue relaxation properties, 37 , 96 leading to differences in image SNR for dMRI. Neutral buffered formalin (NBF; formalin buffered with PBS) at 10% concentration can be used at room temperature and is most commonly used for immersion fixation in large samples (where higher temperature speeds up the penetration), while PFA at 4% in buffered solution should be kept cold and is standard for perfusion fixation. Both result in a 4% formaldehyde solution. Buffered fixatives (NBF or buffered PFA) may be preferred to their unbuffered versions. For example, brains fixed with NBF have higher T2 values than brains fixed with standard formalin 102 (Figure 5). Reducing these fixative concentrations by half has been shown to also prolong T2 and improve SNR in fixed tissue. 103 , 104 The addition of glutaraldehyde to the fixative solution improves ultrastructural brain tissue preservation in the case of immersion‐fixation, 105 a mandatory requirement particularly for electron microscopy cross‐validation studies. The use of a fixative solution combining glutaraldehyde and paraformaldehyde has been shown to be MRI compatible while providing a better preservation of the cytoskeletal structures than paraformaldehyde fixative alone, 106 while also better preserving membrane permeability. 37 However, high glutaraldehyde concentrations can reduce the immunogenicity of antigens for immunohistochemistry analyses, 101 but concentrations in the 0.05% range are acceptable. 107 For an extensive discussion on other types of fixatives, as well as a comprehensive review on fixation in brain banking, see Ref. 98.
Even using the recommended procedures and concentrations for perfusion‐fixation, there is discrepancy in the literature as to the degree of microstructural changes that the tissue undergoes. Studies mention for example variable levels of preferential shrinkage of certain compartments (e.g., the extracellular space). 108 Brains stored in formaldehyde‐based fixatives may continually shrink during storage, 109 with different structures experiencing differing rates of morphometric change and with different extents over time. 109 , 110 It should be noted though that shrinkage due to chemical fixation is less than that during dehydration and tissue preparation for electron microscopy, for example. 34 , 95 , 108 At the intracellular level, MR microscopy studies on immersion‐fixed, isolated neurons from Aplysia californica show that formaldehyde affects nucleus and cytoplasm evenly. 85 Notably, compartment models of diffusion in vivo have long yielded relative intra‐ to extracellular fractions of 30/70 (or 50/50 at best in white matter) which are in mismatch with 80/20 histological estimates of intra‐ vs. extracellular compartment volume fractions. 111 , 112 The latter are however more consistent with ex vivo diffusion models, which typically report 70/30 signal fractions. 113 This suggests that ex vivo fixed tissue used for dMRI is closer to its histological counterpart than in vivo tissue. It is unclear though whether the change in relative dMRI compartment sizes between in vivo and ex vivo is due to non‐uniform shrinkage with fixation or to non‐uniform changes in compartment T2's, which affect the weighting of compartment signal contributions. 114 Methods such as cryo‐fixation used for electron microscopy, which preserves the in vivo tissue compartment sizes more faithfully, could help shed light on some of these open questions. 108 , 115
Furthermore, there is still controversy as to whether chemical fixation increases or decreases cell membrane permeability, 40 , 116 , 117 which is highly relevant for multi‐compartment tissue models. 113 , 118 A number of dMRI studies on fixed tissue have also reported an additional signal component in tissues, such as “isotropically‐restricted water” in white matter (sometimes referred to as “still water” or “dot compartment”) that is not observed in vivo 3 , 119 , 120 except for the cerebellum. 121 This isotropically‐restricted component is characterized by an extremely low diffusion coefficient, which gives rise to a non‐vanishing diffusion‐weighted signal even at high b‐values (Alexander et al. 2010). The exact origin of such a component is unknown, although it may be related to tissue overfixation or to vacuoles as visualized using synchrotron imaging. 122
In addition, fixation alters the relaxation rates, substantially decreasing T1 and T2. 37 The decrease in T1 is understood to be due to the cross‐linking of proteins that occurs in the fixation reaction, and is not reversible, whereas T2 is decreased due to the presence of unbound fixative, and can be increased back closer to its in vivo value by washing. 37 Consequently, tissue washing or rehydration is beneficial for SNR enhancement and must be considered when designing any ex vivo MRI acquisition protocol (see Section 4.4).
Finally, and crucially, fixation changes the water diffusion coefficient, 37 , 96 , 123 , 124 with important implications for acquisition protocols and biophysical models of dMRI, as will be discussed in Section 4.5.3.
4.4. Sample preparation
Recommendations for sample preparation include (1) wash out free fixative, (2) ensure a robust mechanical setup to eliminate motion during scanning, and (3) verify temperature stabilization prior to acquiring data. If no tissue relaxometry or diffusion quantification is planned, (4) soaking in a gadolinium (Gd) ‐based solution might help to optimize the trade‐off between SNR and acquisition time. 41 , 104 We discuss each in detail below, and also consider the solution that samples may be scanned in.
First, prior to imaging fixed tissues that have been stored in the fixation fluid, we recommend PBS “washes” to rehydrate the sample and wash out free fixatives. This simply entails placing the sample in a PBS solution, augmented with an antibacterial/antifungal product such as sodium azide, and replacing this PBS solution regularly. While the T2 rises quickly, the washing time required for it to stabilize is dependent on sample size, geometry, volume and temperature of PBS solution, fixative concentration and previous time in fixative, 104 with a wide variety of wash times noted in the literature (Table 1). To maximize T2 and reduce the time to its stabilization, we recommend using as large a volume of PBS solution relative to the sample volume as practical and replacing the solution more frequently in the first few hours/days/weeks of washing (e.g., every 12–72 h), depending on sample size. To maximize tissue quality, we recommend refrigerating samples throughout the washing period. Of course, the larger human brain may require several weeks or more to fully wash.
TABLE 1.
Examples of soaking times in PBS prior to MR imaging, depending on specimen size, fixative, etc.
| Specimen | Approximate sample thickness | Soaking time | Fixative | PBS vol | Temperature | No. of solution changes | Reference |
|---|---|---|---|---|---|---|---|
| Ghost erythrocytes | 80 μL | 12 h | Various | 100 × sample vol | 3 | Thelwall et al., 2006, MRM | |
| Rat cortical slices | 0.5 mm | 12 h | 4% formaldehyde | Room temperature | 4–5 | Shepherd et al., MRM, 2009; Shepherd et al., NI, 2009 | |
| Rat spinal cord | ˜2 mm | Overnight | 4% formaldehyde | Shepherd et al., NI, 2009 | |||
| Marmoset brain sections | 2.5 mm | 4 days | 10% formaldehyde | 10 × sample vol | 4°C | 0 | D'Arceuil et al., 2007, NI |
| Marmoset brain | ˜20 mm | 4–6 weeks | 4% formaldehyde | 4°C | 0 | Blezer et al., 2007, NMR Biomed | |
| Rat brain in situ | ˜25 mm | ≥20 days | 2% formaldehyde | 50 mL | 4°C | 0 | Barrett et al., 2022 |
| ≥47 days | 4% formaldehyde | 50 mL | 4°C | 0 | Barrett et al., 2022 | ||
| Macaque brain | ˜40 mm | ≥25 days | 10% formaldehyde | 1 L | 4°C | 0 | D'Arceuil et al., 2007, NI |
| 3 weeks | 4% formaldehyde | ˜200mL | 4°C | 5 | Schilling et al., 2018, NI | ||
| Sheep brain | ˜ 50 mm | ≥ 3 weeks | 4% formaldehyde | Leprince et al., Proc ISMRM, 2015 |
To further increase SNR and CNR, gadolinium‐based contrast agents are often added during the rehydration (washing) step. Gd is a paramagnetic contrast agent in the form of a chelate that facilitates longitudinal relaxation (reduces T1), which allows TR minimization, particularly in 3D acquisition sequences, thus maximizing the SNR per unit time. Alternatively, Gd can be introduced during the perfusion step for small animals, in a technique referred to as “active staining”. 125 If this is done, we still recommend immersing the sample in a Gd solution in addition. Typically, T1 decreases are observed in the sample within 2–3 days in larger brains (macaque brain), 41 although we recommend soaking for 1–2 weeks in Gd solution depending on brain size. Naturally, a higher concentration of Gd results in shorter T1 and T2. 41 , 104 The optimal concentration to use depends on acquisition timings (minimum TE, maximum TR) and on the method of staining (active staining typically uses a higher concentration than soaking), as well as field strength. Selected examples from the literature highlight the range of Gd contrasts and concentrations utilized with different acquisition choices given in Table 2.
TABLE 2.
Examples of the concentration of gadolinium contrast agent used in ex vivo dMRI studies from the literature.
| Concentration (mM) | Contrast agent | TE (ms) | TR (ms) | Magnet (T) | Sample | Reference |
|---|---|---|---|---|---|---|
| 1 | Gd‐DTPA | 32 | 240 | 4.7 | Macaque | 41 |
| 1 | Gd‐DTPA | 41 | 410 | 9.4 | Squirrel monkey | 126 |
| 0.5/0.5 | Gd‐DTPA | 26 | 1000 | 9.4 | Zebra finch | 127 |
| 5 | Gadoteridol | 11–15 | 125–150 | 11.7 | Mouse | 128 |
| 5/2.5 | Gd‐DTPA | 21 | 100 | 7 | Rat | 129 |
| 15/1 | Gd‐DTPA | 27 | 250 | 9.4 | Rat | 104 |
| 50/5 | Gd‐DTPA | 15 | 100 | 9.4 | Mouse | 130 |
Note: Where two concentration values are given, the first refers to the active staining concentration (contrast agent added in perfusion fixation), the second to passive staining (soaking post‐fixation). A single concentration value refers to passive staining only.
As a caveat, the effects of gadolinium on specific tissue compartments are not well understood. T1 longitudinal evaluation after Gd‐doping exhibited a complex behavior of T1 variation within different regions. 131 Gd‐soaking is thus best suited for tractography acquisitions, rather than quantitative dMRI studies. Gd staining to optimize SNR has been used without detrimental effects on histology or immunohistochemistry analysis. 104 , 132
Our second recommendation is to ensure a robust mechanical setup to eliminate motion during MRI data acquisition (Figure 7). The sample must be tightly constrained inside the imaging container, to prevent motion within the immersion fluid. This is critical to address both bulk motion and non‐linear deformations that may arise over the duration of a long ex vivo scan (e.g., bending of the brain stem). Notably, non‐linear deformations are particularly challenging to correct when considering the importance of directional information in diffusion MRI. Sample‐holders may be as simple as test tubes, or the cylinder of syringes (which may facilitate removal of air bubbles), as well as holders custom‐made to fit within specific volume coils, often made with clear polycarbonate materials. In addition, some fluids that the sample is immersed in (see below) may have high densities, causing the sample to float if not properly constrained. Constraints are often applied through inserting foam pieces, where several groups have suggested very heavily reticulated foam to facilitate removal of air bubbles. Pieces of agar can also be used to stabilize tissue in a container, though agar is MR visible. If the above options are not feasible, post‐mortem brains can also be placed in a plastic bag. Here, the brain is wrapped with a thin layer of gaze in minimal fluid to reduce air bubbles and susceptibility effects, and the bag is slowly compressed until fluid is expelled to fully remove air bubbles and tied tightly to ensure no leakage. Finally, very fragile tissue specimens, such as embryonic mouse brains, can be immersed in either agar gels, or kept within the skull, for increased mechanical support and to avoid deformation.
FIGURE 7.

Examples of ex vivo samples prepared for dMRI acquisitions. Sample holders may be syringes or test tubes/falcon tubes, custom‐made or 3D printed holders with ventilation valves, or simply placement within a plastic bag robustly secured to a platform. Photos courtesy of Daniel Colvin, Kurt Schilling, Luisa Ciobanu, Stijn Michielse, Francesco Grussu, Raquel Perez‐Lopez, Ileana Jelescu, Tim Dyrby.
To minimize field inhomogeneities, ideally the holder will consist of a simple geometric shape (without sharp boundaries), with the sample immersed in a susceptibility matched fluid. The holder can be designed to minimize coil‐to‐sample distance, and to enable consistent sample positioning to eliminate any orientation effects and facilitate analysis.
Finally, recent advances allow 3D printing dedicated sample holders for minimizing motion/vibration, larger holders for human brains, and the ability to load multiple samples for simultaneous imaging (although with the disadvantage of requiring larger FOV, limited spatial resolution and sub‐optimal shimming across samples).
For data acquisition, samples are typically immersed in either PBS or fluorinated oil. In general, we suggest using a fluorinated oil, which are susceptibility‐matched, inert compounds that do not have 1H protons. Thus, they lead to no signal in 1H MR images, alleviating ghosting artifacts, facilitating image masking, and allowing a smaller, tighter FOV. A variety of fluorinated oils are suitable: perfluoropolyethers such as Fomblin (Solvay) or Galden (Solvay) or perfluorocarbons such as Fluorinert (3 M); and they can be recycled to be reused for multiple scans. While studies have not explicitly looked at the effects of these oils on conventional or immuno‐histology, it is our experience that they do not compromise nor interfere with this analysis. 133 However, it is recommended that after the MRI scan, excess oil be removed off the sample using absorbent paper, followed by several PBS washes to remove any residual oil in the cavities of the tissue sample. While these compounds are inert, the effect of long‐term storage of tissue in them is not known and thus not recommended.
Due to the strong difference in magnetic susceptibility with tissue, any air bubbles trapped in cavities such as brain sulci and ventricles will result in substantial image distortions and should be carefully removed during sample preparation by slightly turning, shaking and agitating the tissue. Alternatively, a vacuum setup to remove trapped air bubbles is very effective. Of note, due to the extremely low pressure, bubbles expand substantially, and the fluid can appear as “boiling.” Lastly, a fine paintbrush may also be used to remove air bubbles while the sample is immersed.
Finally, to remove unwanted time‐dependent signal contributions due to tissue temperature changing during scanning (from the cold storage to bore‐temperature), we advise placing the sample at the desired temperature for at least 4–8 h prior to scanning. 45 It may be beneficial to run a dummy dMRI scan during these hours of temperature regularization to also stabilize possible temperature changes caused by gradient coil heating. As nonlinear motion of the tissue (due to physically handling and setting up the tissue in the magnet) is likely to occur immediately after handling, this extra waiting period (or dummy scans) may minimize motion during the scan itself. Timing should be kept consistent to avoid bias in group comparisons. During the scanning, the use of strong or varying diffusion weightings can influence the temperature environment of the tissue hence the diffusion coefficient. A constant airflow around the tissue can further stabilize the temperature.
4.5. MR scanning
4.5.1. Encoding
Just as for in vivo small animal imaging, 1 a number of possible diffusion encoding, or sensitization schemes are feasible, although the unique changes of decreased diffusivities and relaxation times must be considered. For ex vivo dMRI, the two most common encoding schemes are the pulsed gradient spin echo (PGSE) 134 and SSFP with diffusion preparation. 135 For PGSE encoding, strong diffusion‐sensitization gradients are applied on either side of a 180° refocusing pulse, resulting in a mathematically elegant way to describe diffusion weighting through the b‐value, , (where is the gyromagnetic ratio, G is the gradient strength, is the pulse duration, and pulse separation). Because of its simplicity, PGSE is the most widespread diffusion weighting in both in vivo and ex vivo experiments.
Additionally, SSFP has been heavily utilized ex vivo. In SSFP acquisitions, the signal is retained over multiple TRs, generating both spin echoes and stimulated echoes simultaneously. This results in both high SNR in the absence of diffusion gradients and in strong diffusion weighting in their presence. The primary advantage of SSFP is its highest SNR per unit time of all sequences, and its primary disadvantage is increased sensitivity to motion, limiting its use in vivo, but easily overcome ex vivo. 135 However, unlike PGSE, the signal becomes a complicated function of flip angle, TR, T1, T2, and the diffusion encoding, requiring specialized modeling to quantify diffusion coefficients. 136
Other encodings are also possible ex vivo and are described in more detail in Part 1. Briefly, STEAM sequences enable probing very long diffusion times with the disadvantage of half the SNR compared to PGSE (for equal TEs). 69 Oscillating gradient spin echoes (OGSE) uses periodic sinusoidal gradients to probe much shorter times and length scales, which become particularly small with reduced diffusivity ex vivo, with limitations associated with attaining higher b‐values. 137 , 138 Finally, diffusion encoding can be applied along multiple spatial directions in multi‐dimensional diffusion encoding experiments, 139 which offers potential contrasts related to compartmental kurtosis, compartmental exchange, microscopic anisotropy, or heterogeneity of structural sizes/diameters.
4.5.2. Readout
For ex vivo imaging, readouts can be extremely diverse due to lack of sample motion and long available scan time. Our recommended starting protocol is a multi‐shot (segmented) 3D EPI sequence. While this acquisition scheme comes at the cost of increased scan time and possible artifacts due to physiological motion in vivo, conveniently, ex vivo MRI is not limited by scan time nor motion, hence the recommendation. For these reasons, it is not uncommon to use 4–12 segments, or more. The number of segments should ideally be chosen with the matrix size in mind so that segments of equal size are acquired.
Here, two features have been changed from the typical in vivo protocol: from single to multi‐shot, and from 2D multi‐slice to a 3D sequence. The 3D EPI sequences are capable of achieving substantially higher SNR than 2D EPI. 43 , 140 This SNR gain is due to averaging effects from Fourier encoding the entire tissue volume (i.e., collecting signal from the entire 3D tissue volume). SNR increases as the square root of the number of datapoints in the third spatial dimension, also referred to as second phase‐encode direction, and which corresponds to the slice dimension in 2D multi‐slice experiments. 141 The rationale for going from single to multi‐shot is that a strong segmentation of the 3D EPI read‐out is necessary to prevent image distortions and prohibitively long TEs, especially if high spatial resolution is desired. 3D EPI also comes with the advantage of enabling acquisitions with truly isotropic resolution. Indeed, very high spatial resolutions in the third dimension may not be achievable in 2D multi‐slice acquisitions, as very thin slices may not be feasible depending on the slice‐selection gradient strength.
Despite the intrinsically higher SNR of 3D images, they suffer from suboptimal temporal utilization of T1 relaxation. The TR with optimal SNR per unit time depends on the T 1 value of the tissue and can be determined by means of Bloch simulations or using the following relationship: . This equation can be used to determine the optimal TR in terms of SNRefficiency (SNR / √(total imaging time)): . Conveniently, ex vivo imaging enables the addition of Gadolinium‐based contrast agents to the sample to shorten T 1, and thus the optimal TR, facilitating high SNR efficiency. Example SNR efficiency curves are shown in Figure 8, where the optimal TR is ˜1.25 times the estimated T 1 (for examples of optimizing TE, TR, and diffusion weighting see Other considerations in Section 4.5.3 q‐t coverage; for a discussion of advantages and limitations of contrast agents, see Sample preparation in Section 4.4). It should be noted, however, that short TR's may introduce T 1 weighting and affect the relative contributions of different compartments to the overall signal, in a similar manner to T 2 weighting.
FIGURE 8.

Plots showing how SNR efficiency varies with T1. Curves are based on the SNR‐efficiency equation given in Section 4.5.2 based on a spin echo sequence. The optimal TR is ˜1.25 times the sample T1, although there is a wide range of near‐maximum efficiency. Similar optimization can be performed for TE, and diffusion weightings (see Other considerations in Section 4.5.3 q‐t coverage, for examples).
Alternative readouts are also possible ex vivo. This includes the 2D EPI and spiral readouts as in vivo (described in detail in Part 1 1 ), and many ex vivo studies have taken advantage of the multiple RF echo trains of RARE/FSE, or GRASE, which often offers a good trade‐off between scan time and image quality with high SNR and immunity to distortions. At the extreme end of acquisition is a line‐scan readout, which traverses a single line of k‐space per excitation. While this offers excellent robustness to susceptibility artifacts, it has a low SNR efficiency and may require excessively long scan times, or a tradeoff between spatial and angular resolutions. B0 drift may also become problematic when the scan time is on the order of several days and should be corrected for. Acquisitions can for example be split into 2‐ to 3‐h blocks, with the frequency (and shim, potentially requiring a new B0 map to be acquired) readjusted before each block. This also allows retrieving at least partial data in the event the scanner crashes during the long acquisition.
4.5.3. q‐t coverage
Before setting up diffusion parameters, it is important to understand the theoretical requirements of the chosen data analysis framework which will be used to process the data; this might include requirements of short gradient pulses, long/short diffusion times, certain b‐value regimes, or a number of unique sampling directions.
The primary differences between in vivo and ex vivo data acquisition is the slower diffusion in fixed tissue, which often requires high b‐value and/or longer diffusion times to ensure adequate signal attenuation and spin displacement: concretely, b‐values should be adapted to ensure ˜constant bD product 41 , 59 (we assume here that the sample has been washed to restore T2 values, otherwise short T2 is another consideration for fixed tissue). Indeed, ex vivo diffusivities of fixed tissue remain lower than in vivo even at 37°C, the degree depending on the fixation method (perfusion‐fixation or immersion) and post‐mortem interval. 37 , 41 , 45 , 59 , 142 , 143 Moreover, scanning is often performed at room temperature, resulting in further reduction of diffusivity (change of −1–3% per°C). Selected examples are given in Table 3, where considerable decreases in diffusivity are observed across species in perfusion and immersion fixed brains, as well as in fresh ex vivo tissue. Notably, for tissue that has been suitably perfusion‐fixed, the impact of fixation on the diffusivity is relatively comparable across samples/subjects.
TABLE 3.
Changes in T1, T2, and D reported in the literature due to fixation and washing in PBS.
| T1 | T2 | D | Specimen | Reference | |
|---|---|---|---|---|---|
| Fixation (% change from in vivo to fixed) | ↓ 80% ADC | Macaque brain 2.5 mm sections, immersion fixed | D'Arceuil et al., 2007, NI | ||
| ↓ 64% Trace | Mouse brain perfusion fixed | Sun et al., 2003 MRM | |||
| ↓ 55% MD | Rat spinal cord perfused fixed | Madi et al., 2005, MRM | |||
| ↓ 72% Trace | Mouse brain perfusion fixed | Sun et al., 2005, MRM | |||
| ↓ 50% MD | Squirrel monkey, perfusion fixed | Schilling et al., 2017, MRI | |||
| ↓ 62% MD | Rat brain, perfusion fixed | Wang et al., Eur Radiol Exp, 2018 | |||
| ↓ 22% | ↓ 5% | ↓ 48% MD | Marmoset brain, immersion | Haga et al., Magn Res Med Sci, 2019 | |
| ↓ 40% | ↓ 3% | Mouse brain perfusion fixed | Guilfoyle et al., 2003, NMR Biomed | ||
| ↓ 63% | ↓ 35% | Human immersion fixed | Pfefferbaum et al., 2004, NI | ||
| ↓ 69% | ↓ 27% | Human immersion fixed | Birkl et al., 2016, NMR Biomed | ||
| Ex vivo fresh (% change from in vivo to ex vivo) | ↓ 65–88% MD, AD, RD | Fresh pig brain | Walker et al., 2019, PLoS One | ||
| ↓ 50% ADC | Fresh monkey brain | D'Arceuil et al., 2007, NI | |||
| PBS washing (% change from fixed to washed) | ↑ 7% | ↑ 30% | ↑ 30% ADC | Macaque brain 2.5 mm sections, immersion fixed | D'Arceuil et al., 2007, NI |
| ↑ 7% | ↑ 3% | ↑ 11% MD | Human immersion fixed | Leprince et al., 2015, Proc ISMRM | |
| ↑ 3% | ↑ 72% | ↑ 2% MD | Rat brain, perfusion fixed | Barrett et al. n.d. | |
| Reported no difference | Cat spinal cord, immersion fixed | Pattany et al., 1997, AJNR | |||
| Reported no difference | ↑ 516% (cortex) | Rat cortical slices, immersion fixed | Shepherd et al., 2009, MRM | ||
| ↓ 14% | ↑ 24% | Marmoset brain | Blezer et al., 2007, NMR Biomed |
Note: Data are included from samples fixed with 10% formalin or 4% PFA, scanned at room temperature. Measurements from white matter only are included, unless otherwise noted.
Thus, for both fresh ex vivo and fixed tissue, the drop in diffusivity is typically on the order of approximately two to five at room temperature, which corresponds to increasing the b‐value by a similar factor to match the attenuation expected from an in vivo dMRI protocol. For post‐mortem human samples, however, due to non‐negligible post‐mortem interval and an extended duration of immersion fixation needed to preserve cell and tissue components, the diffusivity is often on the order of 85% lower than in vivo, 144 , 145 also in agreement with animal studies with extended PMI. 96 Consequently, going beyond DTI protocols, including DKI and other advanced dMRI methods is sometimes challenging on post‐mortem human tissue due to the prohibitively high b‐values required. For DTI, an adjusted b‐value to about 4000 s/mm2 41 has been shown to result in similar signal attenuation as for an in vivo b = 1000 s/mm2 scan, and provide the angular contrast needed to resolve crossing fibers for tractography. 45 It should, however, be noted that the optimal b‐value for post‐mortem acquisitions is a function of tissue fixation and scanning temperature and should be evaluated for each experiment individually.
Because of changes in diffusivity, it is important to consider spatial scales that are being probed. As diffusivity drops, diffusion distances proportional to drop as well—unless the diffusion time is prolonged accordingly—which results in different interactions between water molecules and the microscopic features they are able to probe. This may be beneficial when interested in probing geometry on small scales and also extends the limit of the narrow pulse approximation validity. 3 This is additionally important in MR microscopy, where the resolutions start to approach the diffusion length scales, 146 and a significant amount of water may diffuse out of the imaging voxels in the TE such that the spatial resolution is no longer “real.”
Below, we provide guidelines for common applications of ex vivo imaging: signal representations (DTI/DKI), tractography, and biophysical signals models.
DTI: As in in vivo, recommendations include 20–30 non‐collinear directions to mitigate noise, and b‐value chosen so that the product to maximize precision. Ex vivo, this results in a b‐value of approximately 2500–5000 s/mm2, depending on the drop in diffusivity values. For diffusion kurtosis imaging (DKI) the radius of convergence of the cumulant expansion ex vivo translates into the highest b‐value roughly double the optimal one for DTI 10 , 14 , 147 , 148 with a recommended 20–30 directions per shell.
For tractography: ex vivo guidelines again follow closely those of both small animal (Part 1) and human scans in vivo; our recommended protocol includes acquiring 50–60 directions at a moderate‐to‐high b‐value, where a greater diffusion weighting (particularly for ex vivo) leads to a higher angular contrast and ability to resolve complex fiber architectures; for example, Dyrby et al. 45 found a b‐value of ˜4000 s/mm2 to lead to consistent fiber reconstructions with a high angular contrast, although a much larger range of b‐values has also been utilized ex vivo with high angular accuracy and subsequent accurate tractography. 61 , 149 , 150 , 151 , 152
Regarding compartment modeling: it is critical to consider the data requirements of the intended biophysical model, specifically as it relates to diffusion times and diffusion weightings. Similarly, if diffusion‐relaxometry experiments are intended, altered T1 and T2 depending on fixation and subsequent washing must be considered.
Other practical considerations: A great benefit in ex vivo imaging is the ability to conduct multiple experiments on the same tissue. Because relaxation and diffusivity can vary dramatically based on sample preparation (rehydration time, fixative, fixative concentration, contrast agent concentration, etc.), we recommend informing acquisition settings by acquiring scans prior to the start of a new study and optimizing using methods described in the literature. 41 , 104 For example, It is particularly advantageous to measure T1, T2, and diffusivity throughout the sample, and SNR efficiency can be optimized and tuned for both 2D and 3D sequences through changes in TE, TR, and diffusion weightings (Figure 9).
FIGURE 9.

Approach to optimizing ex vivo diffusion protocols. Relaxometry (top) and diffusion (middle) can be measured as a function of contrast concentration, or fixative solution, for both white and gray matter tissue types, and SNR efficiency can be optimized (bottom) by manipulating sequence parameters and gadolinium contrast agent concentration. Images are adapted and modified from 41 (top) and 104 (bottom).
Other practical suggestions, as described in detail in Part 1 and also apply to ex vivo scans are to: (1) use an optimally distributed set of diffusion‐encoding directions that cover the full sampling sphere; (2) randomize ordering of acquisition of DWI images, especially across b‐values to reduce or enable correction of temporal biases, reduce duty cycle, and allow analysis on partial acquisitions; (3) intersperse several/many b = 0 images throughout the scan to enable controlling for temporal drifts 46 ; (4) use the effective b‐matrix (i.e., the realized b‐matrix taking into account other sequence gradients, rather than the nominal value entered into the scanner) which can be measured and validated in phantoms 153 ; and (5) perform high order shimming which may be critical for image quality, particularly at high field strengths due to their increased inhomogeneities.
4.5.4. MR scanning, monitoring, scan duration
During long ex vivo scanning, it is important to minimize artifacts using several acquisition strategies. First, it is recommended that each image or volume be collected within as short a time period as possible, that is, inner‐most loops should cover k‐space sampling while outer‐most loops should cover q‐space sampling. Furthermore, if more than a single acquisition is performed using averaging, it is preferred to acquire each image separately split into repetitions, while saving the complex‐valued data. Averaging repetitions in complex space rather than magnitude space is beneficial for lowering the noise floor to its theoretical zero‐value, as opposed to being affected by the Rician noise floor; however, the advantage of initially saving these volumes as individual repetitions gives the opportunity to omit potentially corrupted individual images, if needed. Phase corrections prior to averaging are mandatory and may need to be implemented by the user if not addressed well by the scanner reconstruction directly. 154 , 155
A stable temperature throughout the protocol is warranted to limit undesired signal drift due to T1‐weighting and diffusivity variations. Potential sample temperature changes over time should therefore be prevented for example by ensuring an air flow around the tissue with constant temperature, as it is not easy to compensate for temperature drift in the post‐processing pipeline. As a temperature control, a water vial can be placed next to the tissue and monitor its diffusivity over time, although it is important to carefully consider where the vial will appear within the FOV due to the addition of possible susceptibility, ringing, or ghosting artifacts. Of note, a temperature increase may also occur in vivo, though the effect may be less pronounced thanks to active thermal regulation of the animal.
Collectively, these strategies do not prevent the artifacts but make them more addressable with subsequent post‐processing.
4.5.5. Spatial resolution
For in vivo human or small animal imaging, spatial resolution should be as high as permissible for the targeted SNR and available scan time. However, ex vivo scans require different considerations when choosing a spatial resolution, due to the substantially increased scan time. While signal drift and temperature stability issues may arise due to increased scan time, resolution can be pushed quite extensively, with recent protocols nearly pushing the boundaries where resolution limits are set by the diffusion process itself, for example, below 10 micrometers. 156
In short, there is no single set of guidelines, or consensus, on image resolution for specific species, nor for specific experimental designs. Rather than providing specific recommendations for resolution, below we give typical volumes of brains, and compute what the equivalent voxel size (i.e., the volume equivalent resolution) would be given the ratio of volumes, and a 2‐mm isotropic human brain scan, typical of in vivo studies (Table 4). Further, we give examples of ex vivo scans that are pushing the boundaries of resolution; we note that these are not always feasible at every imaging center and are not for any specific tractographic or modeling purposes, but only to highlight high resolution scans that have been performed.
TABLE 4.
Summary of brain volumes of various species, matching spatial resolutions to the typical one for human dMRI, and ranges of spatial resolutions reported in the literature, ex vivo.
| Species | Brain volume (mL) | Matching spatial resolution (isotropic) | Reported in literature (ex vivo) |
|---|---|---|---|
| Human | 1200 | 2 mm |
730‐μm isotropic (b = 3000 s/mm2, 64 directions, 4 days, 3D‐EPI) 142 940‐μm isotropic (b ˜ 4500 s/mm2, 54 directions, 1m15s per volume, repeated 10 times, DW‐SSFP) 145 1000‐μm isotropic (b ˜ 5175–8550 s/mm2, 49–52 directions, DW‐SSFP, 10–11 min per volume) 144 500‐μm isotropic (b ˜ 1700–5000 s/mm2, 120 directions, DW‐SSFP, 45 min per volume) 157 100‐μm isotropic (hippocampus) (b = 4000 s/mm2, 12 directions, 63 h. acquisition) 68 200‐μm isotropic (brainstem+thalamus) (b = 4000 s/mm2, 120 directions, 208 h. acquisition) 65 400‐μm isotropic (b ˜ 3000 s/mm2, 2h23m/volume); 500‐μm isotropic (b ˜ 2000/4000 s/mm2, 53 m/volume); 1000‐μm isotropic (b ˜ 1000 s/mm2, 23 m/volume)—kT‐dSTEAM 69 |
| Mouse | 0.4 | 140 μm |
25‐μm isotropic (b = 4000 s/mm2, 61 directions, 95 h scan, 3D‐SE) 158 43‐μm isotropic (b = 4000 s/mm2, 120 directions, 235 h scan, 3D‐SE) 130 100‐μm isotropic (b = 2000/5000 s/mm2, 60 directions, 12 h scan, 3D‐SE) 159 |
| Rat | 0.6 | 160 μm |
50‐μm isotropic (b = 3000 s/mm2,61 directions, 289 h scan, 3D‐SE) 160 150‐μm isotropic (b = 3000/6000 s/mm2, 30/30 directions, 21 h scan, 3D‐DW‐GRASE) 161 88‐μm isotropic (b = 800 s/mm2, 12 directions, 18 h scan, 3D‐SE) 29 78‐μm isotropic (b = 1500 s/mm2, 6 directions) 27 (b = 4000 s/mm2, 30 directions) 27 |
| Squirrel monkey | 35 | 600 μm | 300‐μm isotropic (b = 3000/6000/9000/12000 s/mm2, 100 directions each, 48 h. scan, 3D‐EPI) 151 |
| Mini‐pig | 64 | 750 μm | 500‐μm isotropic (b = 4009 s/mm2), 61 directions, 28 hrs, 2D‐SE) 72 |
| Macaque | 80 | 800 μm |
390 × 540 × 520 μm (b = 1000 s/mm2, 8 directions, 45 h. scan, 3D multiple echo SE) 28 500–1000 μm isotropic (b = 1477–9500 s/mm2, 20–180 directions, up to 19 days scan, 2D‐SE) 19 , 162 , 163 600‐μm isotropic (b = 4000 s/mm2, 60 directions, 2D‐SE single echo) 164 200‐μm isotropic (b = 100–10 000 s/mm2, 3–36 directions, 93 h. scan, 3D‐EPI) 140 , 164 200‐μm isotropic (b = 500, 1000, 4000,10 000 s/mm2, 8–16–32–64 directions respectively, 73 h. scan, 3D‐EPI). 131 300‐μm isotropic (b = 6000 s/mm2, 101 directions, 3D‐EPI) 126 250‐μm isotropic (b = 4800 s/mm2, 121 directions, 71 h. scan, 3D‐EPI) 58 600‐μm isotropic (b = 4000 s/mm2, 128 gradient directions, DW‐SE multi‐slice) 165 1000‐μm isotropic (b = 4000, 7000 and 10 000 s/mm2, 250–1000–1000 directions respectively + spherical tensor encoding, DW‐SE multi‐slice) 165 |
| Macaque | 35 | 600 μm | 80‐μm isotropic (b = 2400 s/mm2, 64 directions, 15 days 3D‐EPI) 7 |
Note: The references provided are not comprehensive.
Volume equivalent resolutions and pushing the boundaries
MR microscopy is defined as MR imaging with a spatial resolution in the micrometer range, which makes it possible to even image individual cells. Indeed, with dedicated setups that allow sufficiently high SNR, MRI with a resolution of a few μm becomes feasible. 85 , 166 , 167 , 168 , 169 By convention, MRI transforms to MR microscopy (MRM) when the voxel side lengths are less than 100 μm. 170 A number of effects and considerations are encountered in MR microcopy that must be considered with respect to hardware, sequences, diffusion dispersion, and data processing. For an introduction to MRM emphasizing practical aspects relevant to high magnetic fields see Ref. 171, a review in Ref. 172, and details of microscale nuclear magnetic resonance hardware in Ref. 173
4.6. Storage
Ex vivo offers the advantage that repeated scans of fixed brains can be performed, enabling longer scans, multiple sessions, and optimization of the sequences and contrasts over time. Here, if tissue storage is necessary, we recommend storing the samples in either a PBS solution with sodium azide to inhibit bacterial and fungal growth, or in a weak fixative solution (1% formalin in PBS), at low temperature (4–5°C). Long‐term storage at room temperature is also possible in 4% formaldehyde, although it is associated with an increase in formic acid and methanol which may have a dehydrating effect, and a slow decline in T1 and T2 relaxation times. 174 , 175 These effects can be mitigated by regularly refreshing the formaldehyde solution and by sufficient rehydration prior to scanning. Several studies have investigated the effects of storage time on diffusion metrics, and concluded that with appropriate care, tissue can be rescanned over several years with negligible variability in results. 45 , 176 Once fixed, the tissue quality should be inspected periodically 34 , 45 to ensure tissue integrity and absence of bacterial or fungal growth.
5. CONCLUSIONS
In this manuscript, we have provided an overview of best practices for ex vivo diffusion MRI, focusing on experimental design, sample preparation, and MR scanning. These steps are critical to ensure rigorous and reproducible data collection, and pave the way for subsequent data processing. As we move to the next part of this series, we will shift our focus to pre‐processing, model‐fitting (processing), tractography, and comparisons with microscopy. Together, these recommendations are given to facilitate high quality studies and interpretation of ex vivo dMRI data.
ACKNOWLEDGMENTS
The authors acknowledge financial support from: the National Institutes of Health (K01EB032898, R01AG057991, R01NS125020, R01EB017230, R01EB 019980, R01EB031954, R01CA160620, R01NS109090), the National Institute of Biomedical Imaging and Bioengineering (R01EB031765, R56EB031765), the National Institute on Drug Abuse (P30DA048742), the Secretary of Universities and Research (Government of Catalonia) Beatriu de Pinós postdoctoral fellowship (2020 BP 00117), “la Caixa” Foundation Junior Leader fellowship (LCF/BQ/PR22/11920010), the Research Foundation Flanders (FWO: 12M3119N), the Belgian Science Policy Prodex (Grant ISLRA 2009–1062), the μNEURO Research Center of Excellence of the University of Antwerp, the Institutional research chair in Neuroinformatics (Sherbrooke, Canada), the NSERC Discovery Grant, the European Research Council Consolidator grant (101044180), the Canada Research Chair in Quantitative Magnetic Resonance Imaging [950‐230815], the Canadian Institute of Health Research [CIHR FDN‐143263], the Canada Foundation for Innovation [32 454, 34 824], the Fonds de Recherche du Québec—Santé [322736], the Natural Sciences and Engineering Research Council of Canada [RGPIN‐2019‐07244], the Canada First Research Excellence Fund (IVADO and TransMedTech), the Courtois NeuroMod project, the Quebec BioImaging Network [5886, 35 450], the Mila—Tech Transfer Funding Program and the Swiss National Science Foundation (Eccellenza Fellowship PCEFP2_194260), the Wellcome Trust (202788/Z/16/A, 203139/Z/16/Z and 203139/A/16/Z).
Schilling KG, Grussu F, Ianus A, et al. Considerations and recommendations from the ISMRM diffusion study group for preclinical diffusion MRI: Part 2—Ex vivo imaging: Added value and acquisition. Magn Reson Med. 2025;93:2535‐2560. doi: 10.1002/mrm.30435
Kurt G. Schilling and Ileana O. Jelescu contributed equally to this work.
REFERENCES
- 1. Jelescu IO, Grussu F, Ianus A, et al. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 – In vivo small‐animal imaging. Magn Reson Med. 2025;93:2507‐2534. doi: 10.1002/mrm.30429 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Schilling KG, Howard AFD, Grussu F, et al., Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3 — Ex vivo imaging: data processing, comparisons with microscopy, and tractography. Magn Reson Med. 2025;93:2561‐2582. doi: 10.1002/mrm.30424 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Alexander DC, Hubbard PL, Hall MG, et al. Orientationally invariant indices of axon diameter and density from diffusion MRI. NeuroImage. 2010;52:1374‐1389. [DOI] [PubMed] [Google Scholar]
- 4. Sepehrband F, Alexander DC, Kurniawan ND, Reutens DC, Yang Z. Towards higher sensitivity and stability of axon diameter estimation with diffusion‐weighted MRI. NMR Biomed. 2016;29:293‐308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Budde MD, Frank JA. Examining brain microstructure using structure tensor analysis of histological sections. NeuroImage. 2012;63:1‐10. [DOI] [PubMed] [Google Scholar]
- 6. Aggarwal M, Zhang J, Pletnikova O, Crain B, Troncoso J, Mori S. Feasibility of creating a high‐resolution 3D diffusion tensor imaging based atlas of the human brainstem: a case study at 11.7 T. NeuroImage. 2013;74:117‐127. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Liu C, Ye FQ, Newman JD, et al. A resource for the detailed 3D mapping of white matter pathways in the marmoset brain. Nat Neurosci. 2020;23:271‐280. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Hansen B, Flint JJ, Heon‐Lee C, et al. Diffusion tensor microscopy in human nervous tissue with quantitative correlation based on direct histological comparison. NeuroImage. 2011;57:1458‐1465. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Grussu F, Schneider T, Zhang H, Alexander DC, Wheeler‐Kingshott CAM. Neurite orientation dispersion and density imaging of the healthy cervical spinal cord in vivo. NeuroImage. 2015;111:590‐601. [DOI] [PubMed] [Google Scholar]
- 10. Kelm ND, West KL, Carson RP, Gochberg DF, Ess KC, Does MD. Evaluation of diffusion kurtosis imaging in ex vivo hypomyelinated mouse brains. NeuroImage. 2016;124:612‐626. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Suárez LE, Yovel Y, van den Heuvel MP, et al. A connectomics‐based taxonomy of mammals. doi: 10.1101/2022.03.11.483995 [DOI] [PMC free article] [PubMed]
- 12. Jones DK, Alexander DC, Bowtell R, et al. Microstructural imaging of the human brain with a “super‐scanner”: 10 key advantages of ultra‐strong gradients for diffusion MRI. NeuroImage. 2018;182:8‐38. [DOI] [PubMed] [Google Scholar]
- 13. Does MD, Parsons EC, Gore JC. Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med. 2003;49:206‐215. [DOI] [PubMed] [Google Scholar]
- 14. Aggarwal M, Smith MD, Calabresi PA. Diffusion‐time dependence of diffusional kurtosis in the mouse brain. Magn Reson Med. 2020;84:1564‐1578. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Pyatigorskaya N, Le Bihan D, Reynaud O, Ciobanu L. Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortex. Magn Reson Med. 2014;72:492‐500. [DOI] [PubMed] [Google Scholar]
- 16. Wu D, Martin LJ, Northington FJ, Zhang J. Oscillating gradient diffusion MRI reveals unique microstructural information in normal and hypoxia‐ischemia injured mouse brains. Magn Reson Med. 2014;72:1366‐1374. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Assaf Y, Blumenfeld‐Katzir T, Yovel Y, Basser PJ. AxCaliber: a method for measuring axon diameter distribution from diffusion MRI. Magn Reson Med. 2008;59:1347‐1354. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Jespersen SN, Bjarkam CR, Nyengaard JR, et al. Neurite density from magnetic resonance diffusion measurements at ultrahigh field: comparison with light microscopy and electron microscopy. NeuroImage. 2010;49:205‐216. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19. Dyrby TB, Sogaard LV, Hall MG, Ptito M, Alexander DC. Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI. Magn Reson Med. 2013;70:711‐721. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20. Xu J, Li H, Harkins KD, et al. Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy. NeuroImage. 2014;103:10‐19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Ianuş A, Jespersen SN, Serradas Duarte T, Alexander DC, Drobnjak I, Shemesh N. Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain. NeuroImage. 2018;183:934‐949. [DOI] [PubMed] [Google Scholar]
- 22. Lundell H, Nilsson M, Dyrby TB, et al. Multidimensional diffusion MRI with spectrally modulated gradients reveals unprecedented microstructural detail. Sci Rep. 2019;9:9026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Johnson GA, Badea A, Brandenburg J, et al. Waxholm space: an image‐based reference for coordinating mouse brain research. NeuroImage. 2010;53:365‐372. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Aggarwal M, Zhang J, Mori S. Magnetic resonance imaging‐based mouse brain atlas and its applications. Methods Mol Biol. 2011;711:251‐270. [DOI] [PubMed] [Google Scholar]
- 25. Ullmann JFP, Watson C, Janke AL, Kurniawan ND, Reutens DC. A segmentation protocol and MRI atlas of the C57BL/6J mouse neocortex. NeuroImage. 2013;78:196‐203. [DOI] [PubMed] [Google Scholar]
- 26. Liu C, Ye FQ, Yen CCC, et al. A digital 3D atlas of the marmoset brain based on multi‐modal MRI. NeuroImage. 2018;169:106‐116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Papp EA, Leergaard TB, Calabrese E, Johnson GA, Bjaalie JG. Waxholm space atlas of the Sprague Dawley rat brain. NeuroImage. 2014;97:374‐386. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. Feng L, Jeon T, Yu Q, et al. Population‐averaged macaque brain atlas with high‐resolution ex vivo DTI integrated into in vivo space. Brain Struct Funct. 2017;222:4131‐4147. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29. Veraart J, Leergaard TB, Antonsen BT, et al. Population‐averaged diffusion tensor imaging atlas of the Sprague Dawley rat brain. NeuroImage. 2011;58:975‐983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Lee CH, Blackband SJ, Fernandez‐Funez P. Visualization of synaptic domains in the drosophila brain by magnetic resonance microscopy at 10 micron isotropic resolution. Sci Rep. 2015;5:8920. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Kjonigsen LJ, Lillehaug S, Bjaalie JG, Witter MP, Leergaard TB. Waxholm space atlas of the rat brain hippocampal region: three‐dimensional delineations based on magnetic resonance and diffusion tensor imaging. NeuroImage. 2015;108:441‐449. [DOI] [PubMed] [Google Scholar]
- 32. Osen KK, Imad J, Wennberg AE, Papp EA, Leergaard TB. Waxholm space atlas of the rat brain auditory system: three‐dimensional delineations based on structural and diffusion tensor magnetic resonance imaging. NeuroImage. 2019;199:38‐56. [DOI] [PubMed] [Google Scholar]
- 33. Johnson GA, Benveniste H, Black RD, Hedlund LW, Maronpot RR, Smith BR. Histology by magnetic resonance microscopy. Magn Reson Q. 1993;9:1‐30. [PubMed] [Google Scholar]
- 34. Dyrby TB, Innocenti GM, Bech M, Lundell H. Validation strategies for the interpretation of microstructure imaging using diffusion MRI. NeuroImage. 2018;182:62‐79. [DOI] [PubMed] [Google Scholar]
- 35. Flint JJ, Menon K, Hansen B, Forder J, Blackband SJ. A microperfusion and in‐bore oxygenator system designed for magnetic resonance microscopy studies on living tissue explants. Sci Rep. 2015;5:18095. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Zhang J, Jones MV, McMahon MT, Mori S, Calabresi PA. In vivo and ex vivo diffusion tensor imaging of cuprizone‐induced demyelination in the mouse corpus callosum. Magn Reson Med. 2012;67:750‐759. doi: 10.1002/mrm.23032 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37. Shepherd TM, Thelwall PE, Stanisz GJ, Blackband SJ. Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue. Magn Reson Med. 2009;62:26‐34. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Budde MD, Song SK. Insights into diffusion tensor imaging from animal models of white matter pathology. Diffusion MRI. 2010;670‐701. doi: 10.1093/med/9780195369779.003.0042 [DOI] [Google Scholar]
- 39. Wehrl HF, Bezrukov I, Wiehr S, et al. Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging. Histol Histopathol. 2015;30:601‐613. [DOI] [PubMed] [Google Scholar]
- 40. Thelwall PE, Shepherd TM, Stanisz GJ, Blackband SJ. Effects of temperature and aldehyde fixation on tissue water diffusion properties, studied in an erythrocyte ghost tissue model. Magn Reson Med. 2006;56:282‐289. [DOI] [PubMed] [Google Scholar]
- 41. D'Arceuil HE, Westmoreland S, de Crespigny AJ. An approach to high resolution diffusion tensor imaging in fixed primate brain. NeuroImage. 2007;35:553‐565. [DOI] [PubMed] [Google Scholar]
- 42. Sun SW, Neil JJ, Liang HF, et al. Formalin fixation alters water diffusion coefficient magnitude but not anisotropy in infarcted brain. Magn Reson Med. 2005;53:1447‐1451. [DOI] [PubMed] [Google Scholar]
- 43. Rane S, Duong TQ. Comparison of in vivo and ex vivo diffusion tensor imaging in rhesus macaques at short and long diffusion times. Open Neuroimaging J. 2011;5:172‐178. doi: 10.2174/1874440001105010172 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Sun SW, Neil JJ, Song SK. Relative indices of water diffusion anisotropy are equivalent in live and formalin‐fixed mouse brains. Magn Reson Med. 2003;50:743‐748. [DOI] [PubMed] [Google Scholar]
- 45. Dyrby TB, Baaré WFC, Alexander DC, Jelsing J, Garde E, Søgaard LV. An ex vivo imaging pipeline for producing high‐quality and high‐resolution diffusion‐weighted imaging datasets. Hum Brain Mapp. 2011;32:544‐563. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46. Vos SB, Tax CMW, Luijten PR, Ourselin S, Leemans A, Froeling M. The importance of correcting for signal drift in diffusion MRI. Magn Reson Med. 2017;77:285‐299. doi: 10.1002/mrm.26124 [DOI] [PubMed] [Google Scholar]
- 47. Pajevic S, Pierpaoli C. Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: application to white matter fiber tract mapping in the human brain. Magn Reson Med. 2000;43:921. [DOI] [PubMed] [Google Scholar]
- 48. Nonhuman primates and medical research. 1973. doi: 10.1016/c2013-0-10403-5 [DOI]
- 49. Sibal LR, Samson KJ. Nonhuman primates: a critical role in current disease research. ILAR J. 2001;42:74‐84. doi: 10.1093/ilar.42.2.74 [DOI] [PubMed] [Google Scholar]
- 50. The Squirrel Monkey in Biomedical and Behavioral Research . 2000.
- 51. Royo J, Forkel SJ, Pouget P, Thiebaut de Schotten M. The squirrel monkey model in clinical neuroscience. Neurosci Biobehav Rev. 2021;128:152‐164. [DOI] [PubMed] [Google Scholar]
- 52. Sarubbo S, Petit L, De Benedictis A, Chioffi F, Ptito M, Dyrby TB. Uncovering the inferior fronto‐occipital fascicle and its topological organization in non‐human primates: the missing connection for language evolution. Brain Struct Funct. 2019;224:1553‐1567. [DOI] [PubMed] [Google Scholar]
- 53. Mandonnet E, Sarubbo S, Petit L. The nomenclature of human White matter association pathways: proposal for a systematic taxonomic anatomical classification. Front Neuroanat. 2018;12:94. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54. Panesar SS, Fernandez‐Miranda J. Commentary: the nomenclature of human White matter association pathways: proposal for a systematic taxonomic anatomical classification. Front Neuroanat. 2019;13:61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55. Schilling KG, Rheault F, Petit L, et al. Tractography dissection variability: what happens when 42 groups dissect 14 white matter bundles on the same dataset? NeuroImage. 2021;243:118502. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56. Schmahmann JD, Pandya D. Fiber Pathways of the Brain. OUP USA; 2009. [Google Scholar]
- 57. Schilling KG, Petit L, Rheault F, et al. Brain connections derived from diffusion MRI tractography can be highly anatomically accurate‐if we know where white matter pathways start, where they end, and where they do not go. Brain Struct Funct. 2020;225:2387‐2402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58. Thomas C, Ye FQ, Irfanoglu MO, et al. Anatomical accuracy of brain connections derived from diffusion MRI tractography is inherently limited. Proc Natl Acad Sci USA. 2014;111:16574‐16579. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59. Roebroeck A, Miller KL, Aggarwal M. Ex vivo diffusion MRI of the human brain: technical challenges and recent advances. NMR Biomed. 2019;32:e3941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. Budde MD, Annese J. Quantification of anisotropy and fiber orientation in human brain histological sections. Front Integr Neurosci. 2013;7:3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61. Jones R, Grisot G, Augustinack J, et al. Insight into the fundamental trade‐offs of diffusion MRI from polarization‐sensitive optical coherence tomography in ex vivo human brain. NeuroImage. 2020;214:116704. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62. Roebroeck A, Galuske R, Formisano E, et al. High‐resolution diffusion tensor imaging and tractography of the human optic chiasm at 9.4 T. NeuroImage. 2008;39:157‐168. [DOI] [PubMed] [Google Scholar]
- 63. Seehaus A, Roebroeck A, Bastiani M, et al. Histological validation of high‐resolution DTI in human post mortem tissue. Front Neuroanat. 2015;9:98. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64. Adil SM, Calabrese E, Charalambous LT, et al. A high‐resolution interactive atlas of the human brainstem using magnetic resonance imaging. NeuroImage. 2021;237:118135. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65. Calabrese E, Hickey P, Hulette C, et al. Postmortem diffusion MRI of the human brainstem and thalamus for deep brain stimulator electrode localization. Hum Brain Mapp. 2015;36:3167‐3178. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66. Kleinnijenhuis M. Imaging Fibres in the brain. Michiel Kleinnijenhuis; 2014. [Google Scholar]
- 67. Aggarwal M, Nauen DW, Troncoso JC, Mori S. Probing region‐specific microstructure of human cortical areas using high angular and spatial resolution diffusion MRI. NeuroImage. 2015;105:198‐207. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68. Ly M, Foley L, Manivannan A, Hitchens TK, Richardson RM, Modo M. Mesoscale diffusion magnetic resonance imaging of the ex vivo human hippocampus. Hum Brain Mapp. 2020;41:4200‐4218. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69. Fritz FJ, Sengupta S, Harms RL, Tse DH, Poser BA, Roebroeck A. Ultra‐high resolution and multi‐shell diffusion MRI of intact ex vivo human brains using k‐dSTEAM at 9.4T. NeuroImage. 2019;202:116087. [DOI] [PubMed] [Google Scholar]
- 70. Sauleau P, Lapouble E, Val‐Laillet D, Malbert CH. The pig model in brain imaging and neurosurgery. Animal. 2009;3:1138‐1151. doi: 10.1017/s1751731109004649 [DOI] [PubMed] [Google Scholar]
- 71. Bech J, Orlowski D, Glud AN, Dyrby TB, Sørensen JCH, Bjarkam CR. Ex vivo diffusion‐weighted MRI tractography of the Göttingen minipig limbic system. Brain Struct Funct. 2020;225:1055‐1071. [DOI] [PubMed] [Google Scholar]
- 72. Dyrby TB, Søgaard LV, Parker GJ, et al. Validation of in vitro probabilistic tractography. NeuroImage. 2007;37:1267‐1277. [DOI] [PubMed] [Google Scholar]
- 73. Hutchinson EB, Schwerin SC, Radomski KL, et al. Detection and distinction of mild brain injury effects in a ferret model using diffusion tensor MRI (DTI) and DTI‐driven tensor‐based morphometry (D‐TBM). Front Neurosci. 2018;12:573. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74. Hutchinson EB, Schwerin SC, Radomski KL, Irfanoglu MO, Juliano SL, Pierpaoli CM. Quantitative MRI and DTI abnormalities during the acute period following CCI in the ferret. Shock. 2016;46:167‐176. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75. Delettre C, Messé A, Dell LA, et al. Comparison between diffusion MRI tractography and histological tract‐tracing of cortico‐cortical structural connectivity in the ferret brain. Netw Neurosci. 2019;3:1038‐1050. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76. van de Looij Y, van de Looij Y, Lodygensky GA, et al. High‐field diffusion tensor imaging characterization of cerebral white matter injury in lipopolysaccharide‐exposed fetal sheep. Pediatr Res. 2012;72:285‐292. doi: 10.1038/pr.2012.72 [DOI] [PubMed] [Google Scholar]
- 77. Pieri V, Trovatelli M, Cadioli M, et al. Diffusion tensor magnetic resonance Tractography of the sheep brain: an atlas of the ovine White matter fiber bundles. Front Vet Sci. 2019;6:345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78. Quezada S, van de Looij Y, Hale N, et al. Genetic and microstructural differences in the cortical plate of gyri and sulci during gyrification in fetal sheep. Cereb Cortex. 2020;30:6169‐6190. [DOI] [PubMed] [Google Scholar]
- 79. Jacqmot O, Van Thielen B, Fierens Y, et al. Diffusion tensor imaging of white matter tracts in the dog brain. Anat Rec. 2013;296:340‐349. [DOI] [PubMed] [Google Scholar]
- 80. Takahashi E, Dai G, Rosen GD, et al. Developing neocortex organization and connectivity in cats revealed by direct correlation of diffusion tractography and histology. Cereb Cortex. 2011;21:200‐211. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81. Assaf Y, Bouznach A, Zomet O, Marom A, Yovel Y. Conservation of brain connectivity and wiring across the mammalian class. Nat Neurosci. 2020;23:805‐808. [DOI] [PubMed] [Google Scholar]
- 82. Beaulieu C. The basis of anisotropic water diffusion in the nervous system ‐ a technical review. NMR Biomed. 2002;15:435‐455. doi: 10.1002/nbm.782 [DOI] [PubMed] [Google Scholar]
- 83. Beaulieu C, Allen PS. Water diffusion in the giant axon of the squid: implications for diffusion‐weighted MRI of the nervous system. Magn Reson Med. 1994;32:579‐583. [DOI] [PubMed] [Google Scholar]
- 84. Jelescu IO, Ciobanu L, Geffroy F, Marquet P, Le Bihan D. Effects of hypotonic stress and ouabain on the apparent diffusion coefficient of water at cellular and tissue levels in Aplysia. NMR Biomed. 2014;27:280‐290. [DOI] [PubMed] [Google Scholar]
- 85. Lee CH, Flint JJ, Hansen B, Blackband SJ. Investigation of the subcellular architecture of L7 neurons of Aplysia californica using magnetic resonance microscopy (MRM) at 7.8 microns. Sci Rep. 2015;5:11147. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86. Hsu EW, Aiken NR, Blackband SJ. A study of diffusion isotropy in single neurons by using NMR microscopy. Magn Reson Med. 1997;37:624‐627. [DOI] [PubMed] [Google Scholar]
- 87. Grant SC, Buckley DL, Gibbs S, Webb AG, Blackband SJ. MR microscopy of multicomponent diffusion in single neurons. Magn Reson Med. 2001;46:1107‐1112. [DOI] [PubMed] [Google Scholar]
- 88. Flint JJ, Menon K, Hansen B, Forder J, Blackband SJ. Visualization of live, mammalian neurons during Kainate‐infusion using magnetic resonance microscopy. NeuroImage. 2020;219:116997. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89. Flint J, Hansen B, Vestergaard‐Poulsen P, Blackband SJ. Diffusion weighted magnetic resonance imaging of neuronal activity in the hippocampal slice model. NeuroImage. 2009;46:411‐418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90. Hsu EW, Aiken NR, Blackband SJ. Nuclear magnetic resonance microscopy of single neurons under hypotonic perturbation. Am J Phys. 1996;271:C1895‐C1900. [DOI] [PubMed] [Google Scholar]
- 91. Blackband SJ, Flint JJ, Hansen B, et al. On the origins of diffusion MRI signal changes in stroke. Front Neurol. 2020;11:11. doi: 10.3389/fneur.2020.00549 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92. Thelwall PE, Grant SC, Stanisz GJ, Blackband SJ. Human erythrocyte ghosts: exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonance. Magn Reson Med. 2002;48:649‐657. [DOI] [PubMed] [Google Scholar]
- 93. Rooney WD, Johnson G, Li X, et al. Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo. Magn Reson Med. 2007;57:308‐318. [DOI] [PubMed] [Google Scholar]
- 94. de Graaf RA, Brown PB, McIntyre S, Nixon TW, Behar KL, Rothman DL. High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo. Magn Reson Med. 2006;56:386‐394. [DOI] [PubMed] [Google Scholar]
- 95. Fox CH, Johnson FB, Whiting J, Roller PP. Formaldehyde fixation. J Histochem Cytochem. 1985;33:845‐853. [DOI] [PubMed] [Google Scholar]
- 96. D'Arceuil H, de Crespigny A. The effects of brain tissue decomposition on diffusion tensor imaging and tractography. NeuroImage. 2007;36:64‐68. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97. Grinberg LT, Amaro E Jr, Teipel S, et al. Assessment of factors that confound MRI and neuropathological correlation of human postmortem brain tissue. Cell Tissue Bank. 2008;9:195‐203. [DOI] [PubMed] [Google Scholar]
- 98. McFadden WC, Walsh H, Richter F, et al. Perfusion fixation in brain banking: a systematic review. Acta Neuropathol Commun. 2019;7:146. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 99. Dawe RJ, Bennett DA, Schneider JA, Vasireddi SK, Arfanakis K. Postmortem MRI of human brain hemispheres: T2 relaxation times during formaldehyde fixation. Magn Reson Med. 2009;61:810‐818. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100. Vučković I, Nayfeh T, Mishra PK, et al. Influence of water based embedding media composition on the relaxation properties of fixed tissue. Magn Reson Imaging. 2020;67:7‐17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101. Kiernan JA. Formaldehyde, formalin, paraformaldehyde and glutaraldehyde: what they are and what they do. Micros Today. 2000;8:8‐13. [Google Scholar]
- 102. Tendler BC, Qi F, Foxley S, et al. A method to remove the influence of fixative concentration on postmortem T2 maps using a kinetic tensor model. Hum Brain Mapp. 2021;42:5956‐5972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103. Birkl C, Soellradl M, Toeglhofer AM, et al. Effects of concentration and vendor specific composition of formalin on postmortem MRI of the human brain. Magn Reson Med. 2018;79:1111‐1115. [DOI] [PubMed] [Google Scholar]
- 104. Barrett RLC, Cash D, Simmons C, et al. Tissue optimisation strategies for high quality ex vivo diffusion imaging. doi: 10.1101/2021.12.13.472113 [DOI] [PMC free article] [PubMed]
- 105. Morin F, Crevier C, Bouvier G, Lacaille JC, Beaulieu C. A fixation procedure for ultrastructural investigation of synaptic connections in resected human cortex. Brain Res Bull. 1997;44:205‐210. [DOI] [PubMed] [Google Scholar]
- 106. Schwartz ED, Cooper ET, Chin CL, Wehrli S, Tessler A, Hackney DB. Ex vivo evaluation of ADC values within spinal cord white matter tracts. AJNR Am J Neuroradiol. 2005;26:390‐397. [PMC free article] [PubMed] [Google Scholar]
- 107. Welikovitch LA, Do Carmo S, Maglóczky Z, et al. Evidence of intraneuronal Aβ accumulation preceding tau pathology in the entorhinal cortex. Acta Neuropathol. 2018;136:901‐917. [DOI] [PubMed] [Google Scholar]
- 108. Korogod N, Petersen CCH, Knott GW. Ultrastructural analysis of adult mouse neocortex comparing aldehyde perfusion with cryo fixation. elife. 2015;4. doi: 10.7554/eLife.05793 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 109. de Guzman AE, Wong MD, Gleave JA, Nieman BJ. Variations in post‐perfusion immersion fixation and storage alter MRI measurements of mouse brain morphometry. NeuroImage. 2016;142:687‐695. [DOI] [PubMed] [Google Scholar]
- 110. Zhang J, Peng Q, Li Q, et al. Longitudinal characterization of brain atrophy of a Huntington's disease mouse model by automated morphological analyses of magnetic resonance images. NeuroImage. 2010;49:2340‐2351. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111. Clark CA, Le Bihan D. Water diffusion compartmentation and anisotropy at high b values in the human brain. Magn Reson Med. 2000;44:852‐859. [DOI] [PubMed] [Google Scholar]
- 112. Jelescu IO, Zurek M, Winters KV, et al. In vivo quantification of demyelination and recovery using compartment‐specific diffusion MRI metrics validated by electron microscopy. NeuroImage. 2016;132:104‐114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113. Olesen JL, Østergaard L, Shemesh N, Jespersen SN. Diffusion time dependence, power‐law scaling, and exchange in gray matter. NeuroImage. 2022;251:118976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114. Jelescu IO, Palombo M, Bagnato F, Schilling KG. Challenges for biophysical modeling of microstructure. J Neurosci Methods. 2020;344:108861. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115. Pallotto M, Watkins PV, Fubara B, Singer JH, Briggman KL. Extracellular space preservation aids the connectomic analysis of neural circuits. elife. 2015;4. doi: 10.7554/eLife.08206 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116. Purea A, Webb AG. Reversible and irreversible effects of chemical fixation on the NMR properties of single cells. Magn Reson Med. 2006;56:927‐931. [DOI] [PubMed] [Google Scholar]
- 117. Sønderby CK, Lundell HM, Søgaard LV, Dyrby TB. Apparent exchange rate imaging in anisotropic systems. Magn Reson Med. 2014;72:756‐762. [DOI] [PubMed] [Google Scholar]
- 118. Jelescu IO, de Skowronski A, Geffroy F, Palombo M, Novikov DS. Neurite exchange imaging (NEXI): a minimal model of diffusion in gray matter with inter‐compartment water exchange. NeuroImage. 2022;256:119277. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 119. Panagiotaki E, Schneider T, Siow B, Hall MG, Lythgoe MF, Alexander DC. Compartment models of the diffusion MR signal in brain white matter: a taxonomy and comparison. NeuroImage. 2012;59:2241‐2254. [DOI] [PubMed] [Google Scholar]
- 120. Grussu F, Schneider T, Tur C, et al. Neurite dispersion: a new marker of multiple sclerosis spinal cord pathology? Ann Clin Transl Neurol. 2017;4:663‐679. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121. Tax CMW, Szczepankiewicz F, Nilsson M, Jones DK. The dot‐compartment revealed? Diffusion MRI with ultra‐strong gradients and spherical tensor encoding in the living human brain. NeuroImage. 2020;210:116534. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122. Andersson M, Kjer HM. Axon morphology is modulated by the local environment and impacts the noninvasive investigation of its structure–function relationship. Proc Natl Acad Sci USA. 2020;117 (52): 33649–33659. 10.1073/pnas.2012533117 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 123. Lohr D, Terekhov M, Veit F, Schreiber LM. Longitudinal assessment of tissue properties and cardiac diffusion metrics of the ex vivo porcine heart at 7 T: impact of continuous tissue fixation using formalin. NMR Biomed. 2020;33:e4298. [DOI] [PubMed] [Google Scholar]
- 124. Tovi M, Ericsson A. Measurements of T1 and T2 over time in formalin‐fixed human whole‐brain specimens. Acta Radiol. 1992;33:400‐404. [PubMed] [Google Scholar]
- 125. Johnson GA, Cofer GP, Gewalt SL, Hedlund LW. Morphologic phenotyping with MR microscopy: the visible mouse. Radiology. 2002;222:789‐793. [DOI] [PubMed] [Google Scholar]
- 126. Schilling K, Gao Y, Janve V, Stepniewska I, Landman BA, Anderson AW. Can increased spatial resolution solve the crossing fiber problem for diffusion MRI? NMR Biomed. 2017;30:e3787. doi: 10.1002/nbm.3787 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 127. Hamaide J, De Groof G, Van Steenkiste G, et al. Exploring sex differences in the adult zebra finch brain: in vivo diffusion tensor imaging and ex vivo super‐resolution track density imaging. NeuroImage. 2017;146:789‐803. [DOI] [PubMed] [Google Scholar]
- 128. Tyszka JM, Readhead C, Bearer EL, Pautler RG, Jacobs RE. Statistical diffusion tensor histology reveals regional dysmyelination effects in the shiverer mouse mutant. NeuroImage. 2006;29:1058‐1065. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 129. Johnson GA, Calabrese E, Badea A, Paxinos G, Watson C. A multidimensional magnetic resonance histology atlas of the Wistar rat brain. NeuroImage. 2012;62:1848‐1856. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 130. Calabrese E, Badea A, Cofer G, Qi Y, Johnson GA. A diffusion MRI Tractography connectome of the mouse brain and comparison with neuronal tracer data. Cereb Cortex. 2015;25:4628‐4637. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 131. Sébille SB, Rolland AS, Welter ML, Bardinet E, Santin MD. Post mortem high resolution diffusion MRI for large specimen imaging at 11.7 T with 3D segmented echo‐planar imaging. J Neurosci Methods. 2019;311:222‐234. [DOI] [PubMed] [Google Scholar]
- 132. Spencer RG, Fishbein KW, Cheng A, Mattson MP. Compatibility of Gd‐DTPA perfusion and histologic studies of the brain. Magn Reson Imaging. 2006;24:27‐31. [DOI] [PubMed] [Google Scholar]
- 133. Iglesias JE, Crampsie S, Strand C, Tachrount M, Thomas DL, Holton JL. Effect of Fluorinert on the histological properties of formalin‐fixed human brain tissue. J Neuropathol Exp Neurol. 2018;77:1085‐1090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 134. Stejskal EO, Tanner JE. Spin diffusion measurements: spin echoes in the presence of a time‐dependent field gradient. J Chem Phys. 1965;42:288‐292. [Google Scholar]
- 135. McNab JA, Jbabdi S, Deoni SCL, Douaud G, Behrens TEJ, Miller KL. High resolution diffusion‐weighted imaging in fixed human brain using diffusion‐weighted steady state free precession. NeuroImage. 2009;46:775‐785. [DOI] [PubMed] [Google Scholar]
- 136. Tendler BC, Foxley S, Cottaar M, Jbabdi S, Miller KL. Modeling an equivalent b‐value in diffusion‐weighted steady‐state free precession. Magn Reson Med. 2020;84:873‐884. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 137. Xu J, Does MD, Gore JC. Quantitative characterization of tissue microstructure with temporal diffusion spectroscopy. J Magn Reson. 2009;200:189‐197. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138. Colvin DC, Yankeelov TE, Does MD, Yue Z, Quarles C, Gore JC. New insights into tumor microstructure using temporal diffusion spectroscopy. Cancer Res. 2008;68:5941‐5947. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 139. Topgaard D. Multidimensional diffusion MRI. J Magn Reson. 2017;275:98‐113. [DOI] [PubMed] [Google Scholar]
- 140. Saleem KS, Avram AV, Glen D, et al. High‐resolution mapping and digital atlas of subcortical regions in the macaque monkey based on matched MAP‐MRI and histology. NeuroImage. 2021;245:118759. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 141. Bernstein MA. Handbook of MRI Pulse Sequences. Elsevier; 2004. [Google Scholar]
- 142. Miller KL, Stagg CJ, Douaud G, et al. Diffusion imaging of whole, post‐mortem human brains on a clinical MRI scanner. NeuroImage. 2011;57:167‐181. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 143. Pfefferbaum A, Sullivan EV, Adalsteinsson E, Garrick T, Harper C. Postmortem MR imaging of formalin‐fixed human brain. NeuroImage. 2004;21:1585‐1595. doi: 10.1016/j.neuroimage.2003.11.024 [DOI] [PubMed] [Google Scholar]
- 144. Foxley S, Jbabdi S, Clare S, et al. Improving diffusion‐weighted imaging of post‐mortem human brains: SSFP at 7T. NeuroImage. 2014;102:579‐589. doi: 10.1016/j.neuroimage.2014.08.014 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 145. Miller KL, McNab JA, Jbabdi S, Douaud G. Diffusion tractography of post‐mortem human brains: optimization and comparison of spin echo and steady‐state free precession techniques. NeuroImage. 2012;59:2284‐2297. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 146. Cho ZH, Ahn CB, Juh SC, et al. Nuclear magnetic resonance microscopy with 4‐microns resolution: theoretical study and experimental results. Med Phys. 1988;15:815‐824. [DOI] [PubMed] [Google Scholar]
- 147. Henriques RN, Jespersen SN, Shemesh N. Correlation tensor magnetic resonance imaging. NeuroImage. 2020;211:116605. [DOI] [PubMed] [Google Scholar]
- 148. Chuhutin A, Hansen B, Jespersen SN. Precision and accuracy of diffusion kurtosis estimation and the influence of b‐value selection. NMR Biomed. 2017;30:e3777. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 149. Maffei C, Girard G, Schilling KG, et al. Insights from the IronTract challenge: optimal methods for mapping brain pathways from multi‐shell diffusion MRI. NeuroImage. 2022;257:119327. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 150. Wang H, Zhu J, Reuter M, et al. Cross‐validation of serial optical coherence scanning and diffusion tensor imaging: a study on neural fiber maps in human medulla oblongata. NeuroImage. 2014;100:395‐404. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 151. Schilling KG, Janve V, Gao Y, Stepniewska I, Landman BA, Anderson AW. Histological validation of diffusion MRI fiber orientation distributions and dispersion. NeuroImage. 2018;165:200‐221. doi: 10.1016/j.neuroimage.2017.10.046 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 152. Grisot G, Haber SN, Yendiki A. Diffusion MRI and anatomic tracing in the same brain reveal common failure modes of tractography. NeuroImage. 2021;239:118300. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 153. Fieremans E, Lee HH. Physical and numerical phantoms for the validation of brain microstructural MRI: a cookbook. NeuroImage. 2018;182:39‐61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 154. Bammer R, Holdsworth SJ, Aksoy M, Skare ST. Phase errors in diffusion‐weighted imaging. Diffusion MRI. 2010;218‐249. doi: 10.1093/med/9780195369779.003.0014 [DOI] [Google Scholar]
- 155. Pizzolato M, Gilbert G, Thiran JP, Descoteaux M, Deriche R. Adaptive phase correction of diffusion‐weighted images. NeuroImage. 2020;206:116274. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 156. van Schadewijk R, Krug JR, Shen D, et al. Magnetic resonance microscopy at cellular resolution and localised spectroscopy of Medicago truncatula at 22.3 tesla. Sci Rep. 2020;10:971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 157. Tendler BC, Hanayik T, Ansorge O, et al. The digital brain Bank, an open access platform for post‐mortem imaging datasets. elife. 2022;11. doi: 10.7554/eLife.73153 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 158. Wang N, White LE, Qi Y, Cofer G, Johnson GA. Cytoarchitecture of the mouse brain by high resolution diffusion magnetic resonance imaging. NeuroImage. 2020;216:116876. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 159. Liang Z, Lee CH, Arefin TM, et al. Virtual mouse brain histology from multi‐contrast MRI via deep learning. elife. 2022;11. doi: 10.7554/eLife.72331 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 160. Johnson GA, Laoprasert R, Anderson RJ, et al. A multicontrast MR atlas of the Wistar rat brain. NeuroImage. 2021;242:118470. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 161. Chary K, Narvaez O, Salo RA, et al. Microstructural tissue changes in a rat model of mild traumatic brain injury. Front Neurosci. 2021;15:746214. doi: 10.3389/fnins.2021.746214 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162. Dyrby TB, Lundell H, Burke MW, et al. Interpolation of diffusion weighted imaging datasets. NeuroImage. 2014;103:202‐213. [DOI] [PubMed] [Google Scholar]
- 163. Ambrosen KS, Eskildsen SF, Hinne M, et al. Validation of structural brain connectivity networks: the impact of scanning parameters. NeuroImage. 2020;204:116207. [DOI] [PubMed] [Google Scholar]
- 164. Mars RB, Foxley S, Verhagen L, et al. The extreme capsule fiber complex in humans and macaque monkeys: a comparative diffusion MRI tractography study. Brain Struct Funct. 2016;221:4059‐4071. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165. Howard AFD, Huszar IN, Smart A, et al. The BigMac dataset: an open resource combining multi‐contrast MRI and microscopy in the macaque brain. Nat Commun. 2023;14:4320. doi: 10.1101/2022.09.08.506363 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 166. Flint JJ, Hansen B, Fey M, et al. Cellular‐level diffusion tensor microscopy and fiber tracking in mammalian nervous tissue with direct histological correlation. NeuroImage. 2010;52:556‐561. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 167. Flint JJ, Hansen B, Portnoy S, et al. Magnetic resonance microscopy of human and porcine neurons and cellular processes. NeuroImage. 2012;60:1404‐1411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 168. Flint JJ, Lee CH, Hansen B, et al. Magnetic resonance microscopy of mammalian neurons. NeuroImage. 2009;46:1037‐1040. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 169. Portnoy S, Flint JJ, Blackband SJ, Stanisz GJ. Oscillating and pulsed gradient diffusion magnetic resonance microscopy over an extended b‐value range: implications for the characterization of tissue microstructure. Magn Reson Med. 2013;69:1131‐1145. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 170. Benveniste H, Blackband SJ. Translational neuroscience and magnetic‐resonance microscopy. Lancet Neurol. 2006;5:536‐544. [DOI] [PubMed] [Google Scholar]
- 171. Ciobanu L. Microscopic Magnetic Resonance Imaging: A Practical Perspective. Jenny Stanford Publishing; 2017. [Google Scholar]
- 172. Winkler SA, Schmitt F, Landes H, et al. Gradient and shim technologies for ultra high field MRI. NeuroImage. 2018;168:59‐70. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 173. Anders J, Korvink JG. Micro and Nano Scale NMR: Technologies and Systems. John Wiley & Sons; 2018. [Google Scholar]
- 174. Raman MR, Shu Y, Lesnick TG, Jack CR, Kantarci K. Regional T1 relaxation time constants in ex vivo human brain: longitudinal effects of formalin exposure. Magn Reson Med. 2017;77:774‐778. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 175. Shatil AS, Uddin MN, Matsuda KM, Figley CR. Quantitative ex vivo MRI changes due to progressive formalin fixation in whole human brain specimens: longitudinal characterization of diffusion, Relaxometry, and myelin water fraction measurements at 3T. Front Med. 2018;5:31. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 176. Xiao J, Hornburg KJ, Cofer G, et al. A time‐course study of actively stained mouse brains: diffusion tensor imaging parameters and connectomic stability over 1 year. NMR Biomed. 2021;35:e4611. doi:10.1002/nbm.4611 [DOI] [PMC free article] [PubMed] [Google Scholar]