Abstract
Small‐animal diffusion MRI (dMRI) has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the resultant data. This work aims to present selected considerations and recommendations from the diffusion community on best practices for preclinical dMRI of in vivo animals. We describe the general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss why some may be more or less appropriate for different studies. We, then, give recommendations for in vivo acquisition protocols, including decisions on hardware, animal preparation, and imaging sequences, followed by advice for data processing including preprocessing, model‐fitting, and tractography. Finally, we provide an online resource that lists publicly available preclinical dMRI datasets and software packages to promote responsible and reproducible research. In each section, we attempt to provide guides and recommendations, but also highlight areas for which no guidelines exist (and why), and where future work should focus. Although we mainly cover the central nervous system (on which most preclinical dMRI studies are focused), we also provide, where possible and applicable, recommendations for other organs of interest. An overarching goal is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
Keywords: acquisition, best practices, diffusion MRI, diffusion tensor, microstructure, open science, preclinical, processing, small animal, tractography
1. INTRODUCTION
Diffusion MRI (dMRI) is a non‐invasive technique that exploits the hindered or restricted mobility of water molecules in biological tissue to extract information about tissue microstructure in both normal and abnormal states.
dMRI studies of in vivo small animals and of ex vivo specimens derived from animal or human tissues, have both greatly contributed to scientific knowledge. In this work, small animal imaging refers to imaging living animal models, whereas ex vivo refers to perfused living tissue or fixed tissue—the latter are covered in separate papers, “Part 2” 1 and “Part 3.” 2 Many influential works in dMRI were first performed in small animals or ex vivo samples. For example, the discovery of a dramatically decreased diffusivity in cerebral ischemia was first observed in a cat model, 3 diffusion tensor imaging formalism was originally validated on vegetables, pork loin, and rabbit models, 4 , 5 and diffusion anisotropy was first observed again in cat models. 6 Microstructural and tractography models of today are routinely validated against animal models, ex vivo scans, and subsequent histological analysis. 6 , 7 , 8 , 9
The added value of preclinical dMRI is multifold (Figure 1). First, small animal dMRI allows correlations with histological and other (invasive) imaging measures to discover the biophysical basis of the dMRI signal, parameters, and biomarkers with the ultimate goal to act as a non‐invasive in vivo microscope. Second, small animal imaging allows acquisition of “extreme” datasets, at the edge of what is achievable in dMRI in terms of spatial resolution and/or diffusion‐weighting coverage, and clearly beyond what is currently achievable with clinical imaging, leveraging the access to much stronger gradients, and to longer scan times. Together these allow the acquisition of more comprehensive datasets. Third, the use of animal models allows us to study the sensitivity of dMRI to tissue changes in diseases, disorders, and treatments in a controlled way that is not always possible in humans, allowing the knowledge gain to be applied to human studies. Small animal MRI can be multimodal, easily longitudinal, and supported by behavior analysis and molecular techniques (optogenetics, omics, immunohistochemistry, etc.) from the same animals. Fourth, the use of animal models enables comparative anatomy, allowing the investigation of differences between human and other mammalian brains.
FIGURE 1.

Four areas in which preclinical brain imaging adds value to the field of dMRI. It enables: (A) correlation with histology on the same subject/sample; (B) the acquisition of richer datasets than on clinical systems thanks to more advanced hardware and longer scan times available; (C) the study of tissue changes with disease and treatment in a more controlled setting; and (D) comparative anatomy between species. Figures reused and adapted from (A), 10 , 11 (B), 12 , 13 , 14 , 15 (C), 16 (D). 17
The science of dMRI covers many disciplines and is continually evolving. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. The present work does not serve as a “consensus” on any specific topic, but rather as a snapshot of “best practices” or “recommendations” from the preclinical dMRI community as represented by the authors. Recruitment for participation in this effort included two meetings of the Diffusion Study Group of the International Society for Magnetic Resonance in Medicine, responses to a survey (Data S1) distributed within the Diffusion Study Group forum, and recommendations for recruitment from other authors. We envision this work to be useful to imaging centers using small animal scanners for research, sites that may not have personnel with expert knowledge in diffusion, pharmaceutical or industry employees who may want to run their own tests and studies, or new trainees in the field of dMRI.
The review is organized as follows. We first describe general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in species and models and discuss why some may be more or less appropriate for different studies. We, then, give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, and imaging sequences, followed by recommendations for data processing including preprocessing, model‐fitting, and tractography. Finally, we give perspectives on the field, describing sharing of code and data, and goals that we wish to achieve. We also highlight areas for which no guidelines exist (and why), and where future work should lie. An overarching goal here, is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
2. TRANSLATIONAL ASPECTS
2.1. Translation and validation considerations
Several aspects must be considered when designing and performing experiments to appropriately interpret scientific results, including the tissue model itself, disease and disorders, and hardware and experimental setup. Although the diffusion process is fundamentally the same, animal experiments must be carefully thought out to translate findings to the in vivo human.
Basic constituents of the brain and other organs are largely preserved across mammalian species, providing a basis for translational in vivo MRI studies. 18 , 19 In the central nervous system, the structure of axons with a myelin sheath makes the dMRI signal interpretation in white matter fundamentally translatable, although there are variations in axon diameter, myelin thickness, and ratio of myelinated to unmyelinated axons. 20 , 21 Brain cortical layers are also largely preserved across species. However, the ratio of white‐to‐gray matter is very different between rodents and primates, with predominant gray matter, unfolded cortex and thin white matter tracts in rodents, and relatively more white matter and folded cortex in primates (see Mota et al. 22 for a comprehensive characterization across mammalian species). As a result, partial volume effects are more challenging to mitigate in rodent white matter and in human/primate gray matter, respectively (Figure 2). Moreover, the complexity of white matter organization in rodents is different from primates, resulting in potential issues when translating modeling and tractography approaches from the rodent brain. However, large bundles such as corpus callosum, the external capsule and the fimbria/fornix retain structure similarity, even in rodents.
FIGURE 2.

dMRI brain images of small animal models demonstrating different brain sizes, geometric complexity, gyrification, and tissue constituents, ordered by increasing complexity. Different tissue types are estimated using multi‐shell multi‐tissue spherical deconvolution 23 and color coded—CSF (red), gray matter (green), and white matter (blue). In vivo data: mouse, rat, human. Ex vivo data: raven, squirrel monkey, macaque. Data kindly provided by Adam Anderson, Ileana Jelescu, Kurt Schilling, Ben Jeurissen, and Marleen Verhoye.
For other organs, intrinsic differences in microstructure do exist, such as much larger hepatocytes in mouse liver compared to humans, 24 , 25 composition of endocrine islets in the pancreas, 26 the existence of a marginal zone in the mouse spleen, 27 etc. Therefore, potential differences need to be considered when interpreting results.
Brain injury models, such as traumatic brain injury (TBI), epilepsy, stroke, subarachnoid and intracerebral hemorrhage, spinal cord injury, edema, or de/re‐myelination have high translational value because the cellular responses to the external insults are similar between species. 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 Tumor models may also display some translational value. 10 , 38 , 39 , 41 , 42 , 43 Even if animal models are not directly translatable, they may offer partial systemic deficits that mimic relevant aspects of the disease (i.e., altered microstructure or connectivity) as in models of neurodegenerative and psychiatric diseases. 40 , 44 , 45
The difference in gradient strength and diffusion times between small animal and clinical acquisitions results in a different sensitivity to spatial scales, such as cell sizes, packing density, etc. Hence, in addition to careful selection of appropriate animal models relevant to the corresponding clinical situation, the diffusion acquisition parameters should be matched carefully in preclinical dMRI studies that aim to validate clinical results.
2.2. Species differences
Species have different pros and cons for imaging studies—which we briefly cover in this section. From an ethical standpoint, it is always recommended to go with the least evolved species that answers the research question at stake. In particular, non‐human primates (NHPs) should only be considered when the sought effect or structure is not present in rodents.
2.2.1. Murine models (mouse and rat)
Rats and mice have been the long‐standing preferred species for biomedical research, including dMRI. Advantages include wide availability, group homogeneity, well‐characterized transgenic models simulating human pathology, and very rapid lifespan. The ability, particularly in mice, to insert human genes allows great flexibility pursuing genomic functional changes that may mimic the human condition. Rats, on the other hand, are less challenging to image, because of larger structure sizes, which improves field homogeneity and, therefore, image quality, and requires lower spatial resolution to resolve fine structures. In addition, the small physical size offers technical advantages, fitting in the typically smaller bores (and smaller coils) of magnets with larger field strengths.
It is, however, important to note that multiple anatomical differences highlighted in Section 2.1, limit the direct translatability of dMRI findings from murine models to humans.
2.2.2. Primate models
NHPs include marmosets, squirrel monkeys, and macaques. They are commonly used in neuroscience research because their brain has a large number of white matter and gray matter regions with homologous human counterparts. NHPs are, therefore, well suited for studies of cortical development, gyrification, and interrogation of complex white matter. NHPs allow access to “ground truth” connectivity, which has been well‐documented through the use of tracer and ablation studies. 46
Controversies regarding the existence or nonexistence of a pathway or the location of pathway terminations have been resolved through primate models, 47 , 48 , 49 , 50 and a number of tractography validation studies have used tracer studies in primates, 51 , 52 , 53 , 54 although validation is most commonly performed on ex vivo samples before histological analysis. 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64
Primate species must also be considered for each experiment: smaller monkeys (galago, squirrel monkey) may be easier to work with, less cumbersome to scan, less expensive to house, and the reduced gyrification makes cortical identification easier (e.g., for injections or electrical stimulation). The disadvantages of NHPs are often associated with access costs. Requirements include complex housing, training for transportation to the scanner and preparation for scanning. Last, small bore preclinical systems and high performing gradient inserts are often not large enough for bigger NHP brains.
2.2.3. Other models
Although murine and NHP models are most widely used in dMRI research, other models include the pig brain, which is comparable to the human brain in myelination and development, 65 , 66 and has been used to study development, 66 brain lesions, 67 and tractography validation. 64 , 65 , 68 Other gyrencephalic brains (e.g., ferrets) have been used to study psychiatric diseases, cognition and brain function, or to validate tractography. 35 , 69 , 70 Songbirds have been used to study fundamental properties of naturally occurring neuroplasticity. 71 Of particular interest, diffusion anisotropy and stroke were first experimentally observed and demonstrated in cat models. 3 , 6 , 72
3. ACQUISITION
Important decisions when performing dMRI of small animals concern appropriate hardware, animal preparation and monitoring, and data acquisition (Figure 3). In this section, we present a recommended “standard” imaging setup and acquisition protocol that can be achieved in 20 to 30 min, and would be appropriate for a wide range of diffusion applications and analyses. Longer scan times allow for richer dMRI data, and ultimately, the chosen protocol should be suitable for the planned analysis.
FIGURE 3.

Small animal in vivo protocols require decisions regarding hardware, animal preparation and monitoring, and acquisition (which include encoding, readout, spatial resolution, and q‐t coverage).
It should be emphasized that these suggestions reflect a typical protocol as a starting point for many studies. Detailed information on each aspect is described to justify our recommendations and we highlight other strategies to optimize diffusion acquisition for any desired experiment.
3.1. Hardware (species/organ specific)
3.1.1. RF Coils
The key to maximizing SNR is using an appropriate RF coil with a high filling factor, defined as the magnetic field energy stored inside the sample volume versus the total magnetic energy. 73 , 74 To this end, combinations of a volume coil for excitation and a surface coil for reception are often used, because they ensure homogeneous excitation and maximum reception sensitivity. For small bore magnets, where the available space is limited, transceiver surface coils can be used. Surface coils perform well when the region of interest is located to the surface. For deeper regions, small volume transmit/receive coils can provide better sensitivity in addition to the improved B1 + homogeneity and are recommended for whole brain studies. Phased array coils cover a larger field of view and can be used in conjunction with parallel imaging strategies for acquisition speed‐up. 75 The use of phased arrays is recommended for larger animals where one can afford to trade SNR for acquisition time reduction. 76
Cryogenic probes (cryoprobes) can increase SNR by factors of 2.5 to 5 compared to standard room‐temperature RF coils, by minimizing thermal coil noise. 77 , 78 Most commercially available cryprobes are for mouse brain and some for rat brain. Indeed, cryoprobes are most beneficial on small samples where the electronic noise dominates. Although cryoprobes operating at ultra‐high field exist, 79 the biggest gains are obtained at lower field strengths. In fact, the SNR gains provided by cryoprobes can bring the signal sensitivity performance of systems operating at 7 to 9.4 T to the levels achieved with ultra‐high‐field systems (≥11.7 T) without the penalty in relaxation times (shorter T2 and longer T1 at higher fields) and susceptibility artifacts.
Diffusion‐weighted (DW) images are typically low SNR. The choice of RF coil is, therefore, of critical importance for the quality of in vivo diffusion acquisitions. Recent work by multiple teams 80 , 81 , 82 has demonstrated the utility of providing open source hardware designs for radiofrequency coils and holders.
3.1.2. Gradients
Clinical systems are typically equipped with 40 to 80 mT/m magnetic field gradients, whereas those on small animal MRI systems are often 300 mT/m or higher, with 1 T/m becoming increasingly widespread. Some small animal systems are available with a high power gradient option and dedicated inserts with up to 3 T/m (along all three axes) are commercially available.
Strong field gradients (G) allow an independent or largely decorrelated exploration of the two dimensions of q‐t space—where q is the spatial phase warp that introduces diffusion sensitization (q=ϒδG) and t is the diffusion time in which the molecules can diffuse and explore the local environment. The combination of the two yields the “b‐value” that quantifies overall diffusion weighting (b=q2t), in the narrow pulse approximation δ → 0). Strong field gradients with rapid switching times further benefit diffusion experiments by enabling fast readouts and short TE's to compensate for shorter T2 at higher field. Our recommendation is to select the MRI system equipped with the strongest and fastest gradient system that is appropriate for the size of the in vivo animal imaging setup.
Stronger gradients present several challenges, including calibration, gradient nonlinearities, and eddy currents. Gradients must be well‐calibrated to ensure accurate gradient fields, and hence, accurate diffusion weightings. Similarly, gradient fields are typically linear at the center of the coil (isocenter), but may deviate at locations further away. The gradient nonlinearity can be mapped and corrected for during diffusion quantification, 83 to reduce its bias on diffusivity estimation particularly for large samples relative to the gradient dimensions. Finally, fast switching gradients induce currents in MRI hardware components, causing eddy current artifacts that must be compensated for, or corrected in processing.
3.1.3. Where future work should lie
Parallel imaging is still very limited on preclinical scanners because of the object's small size and, therefore, the low number of receiver coil elements (usually 1–4 for brain imaging). This limitation is due to the reduced space around the animal, which caps the number of pre‐amplifiers that can fit in the coil. Acquisition with rodent brain array coils typically makes use of parallel imaging methods (e.g., GRAPPA 84 ), but most often achieves less reduction in scan time than in clinical imaging where many more receive channels are available. Progress in this field would be valuable for reducing scan times and artifacts such as ghosting. 85 , 86 , 87 Fortunately, rapid advances in RF circuitry will likely lead to an increase in the number of channels for small animal scanners.
Obstacles to standardization in preclinical studies are the large variability in preclinical imaging instrumentation as compared to clinical MRI systems. Indeed, there is a broader range of possible field strengths (4.7–17.2 T) and gradient capabilities (400 mT/m–3 T/m inserts) that will ultimately affect the achievable protocol. Although, here, we intend to provide recommendations to avoid substantial pitfalls rather than aim at standardization, our community should work toward proposing standardized protocols (and processing pipelines) for preclinical settings that would be achievable on a wide range of systems. This could be achieved following the example of the Quantitative Imaging Biomarkers Alliance (QIBA) guidelines for dMRI in the clinic. 88 Preclinical dMRI standardization may help reproducibility and harmonization for diffusion metrics that are simple (e.g., DTI) and common for characterizing animal models of disease. Such preclinical acquisition guidelines have recently been proposed for rat functional MRI, 89 for example.
3.2. Animal preparation and physiological monitoring
General considerations about experimental design from the biological perspective, planning the experimental protocol, details on equipment needed for anesthesia and monitoring are beyond the scope of this review and the reader can refer to existing literature. 90 , 91 , 92 , 93 We underline, however, that maintaining stable physiological homeostasis during in vivo imaging is important. Reducing stress and physiological differences between animals helps to reduce variability, which is particularly important for identifying group differences and for longitudinal studies.
A minimum monitoring setup should include respiration rate and core temperature. Both respiration and temperature sensors are connected to the physiological monitoring interface and software. Respiration rate is typically monitored using a pillow‐sensor placed under the animal's abdomen. The temperature is monitored via a rectal thermometer and maintained using a warm water circulation system around the animal's body or warm air blown into the MRI tunnel. A key factor for animal homeostasis is that maintenance should be sufficient to prevent edema or brain swelling and prevent whole body dehydration (a particular problem with small animals). A constant core temperature is also warranted to improve consistency of diffusivities and of T1‐weighting throughout the protocol, both of which are temperature‐dependent. 94 A rule of thumb of ΔD = 0.06 μm2/ms/°C for free water (interpolating between D = 2 μm2/ms at 20°C and D = 3 μm2/ms at 37°C), 95 translates approximately into ΔD = 0.02 μm2/ms/°C in living tissue (assuming D = 1 μm2/ms at 37°C), consistent with. 94
3.2.1. Anesthesia
Isoflurane is often the anesthetic of choice given its ease of use and stability over long periods, but others can also be used. 96 It should be noted that a stable temperature and respiration rate of the animal are targeted, and therefore, the anesthesia level should be adapted to maintain that. For prolonged scans, the isoflurane concentration can be gradually reduced if the animal respiration rate decreases.
Data acquired under different anesthetic conditions (anesthesia types, dosage, effective breathing rate, etc.) should be compared with caution, especially as the literature is conflicted. 97 dMRI studies that examine cellular or tissue level effects typically have limited dependence on the anesthetic agent. However, in the mouse brain, mean diffusivity (MD) and mean kurtosis (MK) were both found to be lower under isoflurane than in the awake state, 98 potentially because of inhalation isoflurane decreasing the brain extracellular space volume (cell swelling). 99 In rats, brain ADC has been reported to increase with increasing anesthetic agent dosage for both isoflurane and medetomidine. 100 Furthermore, dMRI used to probe physiological effects such as flow or exchange may require more consideration of the effects of each agent on physiology (vasodilation/constriction, hypoxia, and/or temperature), that have been well‐established in the context of functional MRI, for example. 101 , 102
Recently, advantages in the physiological properties of dexmedetomidine over its racemate medetomidine have been reported and large animal laboratories have started converting their anesthetic protocols. 103 , 104 As effects also vary with the duration of anesthesia, it is recommended to keep timings consistent within an experimental cohort, and therefore, the delay between anesthesia onset and start of the dMRI acquisition.
For post‐scan animal recovery, inhaled anesthetics (e.g., isoflurane) have a faster elimination through the lungs, whereas injectable ones need to be metabolized and excreted (e.g., medetomidine). An antagonist to the latter is recommended to speed up the recovery phase for the animal (e.g., atipamezole).
3.2.2. Positioning
Prone is the most common positioning for the animal. However, in the case of spine imaging, the supine position may be preferred to minimize organ‐induced motion of the spine as well as reduce the distance between the spine and the coil. For liver imaging, the animal may be placed on its flank.
3.2.3. Physiological gating
Brain dMRI does not typically require respiratory or cardiac gating provided the head is sufficiently stabilized within an appropriate holder, which for rodents includes both teeth and ear bars. For organs susceptible to motion, gating strategies to limit the effects of motion are typically imperative. Respiratory and cardiac gating are available on most MRI systems. 105 , 106 , 107 , 108 Prospective gating is the most frequently used method that acquires data intermittently in response to an external trigger, which serves to minimize artifacts in body or spinal cord dMRI or to obtain images from the same phase of motion (e.g., in cardiac dMRI). Retrospective gating techniques that reorganize data after a continuous acquisition are not routinely used for dMRI. Gating typically prolongs acquisition times, but improves the quality of the resulting images. Radial sampling strategies instead of EPI are also an alternative to gating, because they reduce respiration artifacts (ghosting) in abdominal imaging, for example—but they also come at the expense of reduced SNR. 109
3.2.4. Where future work should lie
Systematic reporting of animal monitoring and anesthesia procedures as well as the resulting physiological measures (e.g., respiration rate and core temperature) in dMRI publications can contribute to improved reproducibility and multisite comparison of results.
3.3. Diffusion encoding
A number of possible diffusion encoding or sensitization schemes are shown in Figure 4 (left). 110 Most DW sequences trace their origin to the pulsed gradient spin‐echo (PGSE) 111 encoding scheme pioneered by Ed Stejskal and John Tanner in 1965. PGSE offers a mathematically elegant way to quantify diffusivity, gives access to a biologically relevant range of diffusion times (e.g., 10–50 ms on a preclinical MRI system at high field), and a broad range of b‐values (e.g., 0–10 000 s/mm2). For this reason, PGSE has become the most widely used diffusion encoding strategy in both human and animal imaging and is the “default” encoding scheme on all current scanners.
FIGURE 4.

Diffusion encoding (left) and readout (right). Pulse sequence diagrams are shown for a variety of representative encoding (Section 3.3) and readout (Section 3.4) schemes. Left: RF pulses are represented as hollow waveforms, diffusion gradients as dark color filled shapes (colors represent encoding axes), and the readout module as pale blue. Slice selection gradients are not shown, for simplicity. Right: RF pulses are represented as hollow waveforms, gradients are in dark gray or thick lines. Two axes are shown for phase‐encode and read‐out gradient directions.
Alternative diffusion encodings are possible, particularly on preclinical systems. Stronger gradients can take a variety of shapes, enabling sensitivity to different microstructural features, such as microscopic fractional anisotropy using multidimensional diffusion encoding (MDE) or short length scales using oscillating gradients. Although there is no “consensus” on the best encoding strategy, we describe their pros and cons, and when possible, suggest guidelines when using these sequences.
To probe long diffusion times (e.g., >80 ms) a stimulated echo acquisition mode (STEAM) sequence may be useful, where signal recovery is limited by T1 recovery rather than by T2 decay. 112 The downsides of STEAM is a twofold loss in SNR compared to PGSE (all other factors being equal) and larger contributions from imaging gradients to the diffusion‐weighting via cross‐terms. The latter aspect makes the calculation of the effective b‐value mandatory as it can differ substantially from its nominal value and can raise potential issues with large variations in effective b‐values across directions over the same “shell”. 113
Oscillating gradient spin echo (OGSE) 114 can be used to probe much shorter time and length scales (0.1–10 ms). This comes at the cost of modest attainable b‐values, and a higher risk of nerve stimulation because of rapidly switching strong gradients. The b‐value can be increased by lengthening the duration of the oscillating waveforms, enabling short diffusion times with moderate diffusion weightings.
In the above‐mentioned schemes, the signal is sensitized to diffusion along a single gradient direction, often referred to as a single diffusion encoding (SDE) experiment. MDE techniques encode diffusion along multiple directions within the same measurement. MDE examples include double diffusion encoding (DDE) 115 , 116 or triple diffusion encoding. 117 , 118 This increases the dimensionality of possible controllable parameters, and enables probing microscopic anisotropy, 119 , 120 compartmental kurtosis, 121 or compartmental exchange. 122 , 123 , 124 Further, free gradient waveforms may be designed for investigations into diffusion microscopic anisotropy, structure size variance, and orientational coherence, and is often referred to as q‐trajectory imaging (QTI). 125 Disadvantages of these sequences include potentially longer acquisition times, long echo time, ill‐defined diffusion times, or complicated modeling and analysis. For a review of multidimensional diffusion encoding see Topgaard 118 and Henriques et al. 126
Because of the strong preclinical gradients, eddy currents can create artifacts in diffusion images. It is possible to modify the diffusion encoding to a twice‐refocused spin echo. This eddy current nulled (ECN) encoding can minimize these artifacts, although at the cost of decreased encoding efficiency and a longer TE.
There are many ways to encode diffusion into MRI images. With tradeoffs in diffusion times, diffusion weightings, sequence time, microstructure sensitivity, and artifact sensitivity, the optimal encoding strategy ultimately depends on the experimental question and desired application.
3.4. Signal readout
After diffusion encoding, the signal readout module is played out (Figure 4, right). EPI readout is a rapid acquisition that minimizes effects of bulk motion on diffusion images and acquires images in a single excitation to minimize scan time needed to acquire many diffusion‐weighted volumes. The EPI readout is also compatible with all diffusion encodings. A single‐shot multislice pulsed‐gradient EPI sequence has, therefore, become the most popular in humans and is also our recommended starting point for small animal in vivo imaging. Depending on hardware performance, multi‐shot instead of single‐shot EPI or a smaller imaging matrix can be implemented, until the image quality becomes acceptable in terms of spatial distortions.
Although EPI reduces scan time and motion artifacts, it also faces its own challenges, most prominently spatial distortion because of B0 field inhomogeneity that can be especially challenging at high field strengths, which is typical of preclinical imaging. To alleviate this, it is possible to acquire data with a segmented readout (multi‐shot, as above), at the cost of increased scan time and possible ghosting artifacts, or use partial Fourier acceleration in the phase direction, at the expense of SNR and image sharpness. Finally, acquiring additional reversed phase‐encoded b = 0 images can help in compensating geometrical distortions during image preprocessing (see Section 4.1.1).
Other readouts are also possible for small animal in vivo imaging. For example, rapid acquisition with relaxation enhancement (RARE), sometimes called fast spin echo (FSE) or turbo spin echo (TSE), is less prone to susceptibility induced artifacts, 127 , 128 or gradient and spin echo (GRASE), which also allows acquisition acceleration. 128 Additionally, k‐space can be sampled in a spiral readout rather than Cartesian readout. Spiral acquisitions have several advantages including the possibility to reduce TE. This readout remains nonetheless sensitive to B0 field inhomogeneities and eddy currents (yielding geometric distortions) in the higher spatial frequencies. Although this complicates artifact correction after image reconstruction, eddy currents can be minimized via trajectory measurements. 129
Other approaches combine diffusion weighting with relaxometry measurements in a multidimensional acquisition, for instance using multiple gradient echoes or spin echoes. Such sequences as well as the respective data reconstruction/analysis pipelines are provided in the REMMI toolbox (https://remmi‐toolbox.github.io/) for different vendors.
3.5. q‐t coverage
Unique insights into diffusion signal behavior, and therefore, into the underlying microstructure, have been brought by exploring a range of q‐t regimes on animal systems, including very short diffusion times, 130 , 131 , 132 , 133 very strong diffusion weighting, 134 , 135 or more complex diffusion encoding schemes. 136 , 137 , 138
The “optimal” q‐t coverage is highly dependent on the microstructure feature one wishes to maximize sensitivity to, therefore, there is no direct recommendation on this topic. 139 It is important to determine upfront the theoretical requirements of the data analysis framework that will be used downstream, such as short gradient pulses (narrow pulse approximation), short/long diffusion times, b‐value regime, etc. In general, on preclinical systems there is a lot of flexibility in choosing the sequence parameters, which is very handy for optimization strategies. We recommend acquiring non‐DW images (b = 0) at approximately a ratio of one image for each 10 to 20 DW images. 140 , 141
DTI is by far the most widespread analysis of dMRI data. To maximize precision, the b‐value should be chosen such that the signal decay is substantial (e.g., such that, in vivo the most standard b‐value is b = 1000 s/mm2) as in humans. The b‐value can be adapted based on the animal's body temperature (e.g., songbirds have a higher body temperature [40°C–41°C]) leading to the use of lower b‐values for DTI.
DKI is an extension of DTI that also estimates non‐Gaussian characteristics of water diffusion in biological tissues (diffusion kurtosis) from at least two non‐zero shells with a recommended 20 to 30 directions per shell. 142 The highest b‐value should be chosen as b ≅ 2000 ‐ 2500 s/mm2 in vivo. Often the rule of thumb bmax<3/(DK) can be used, as beyond this, the DKI signal expression starts to increase with increasing b. Given recent advances in acquisition efficiency and speed, we advocate a minimal acquisition of two‐shell data leading to DKI analysis as the new “default” over simple DTI derived from single‐shell data. A two‐shell acquisition also opens up data analysis possibilities beyond DKI (e.g., for multi‐compartment biophysical models). 9 Note, however, that optimal two‐shell design may depend on the target tissue. 143 For this reason, it may be beneficial to use highly sampled repository datasets for study planning. 144 For reduction in DKI scan time, strategies for “fast kurtosis” estimation decrease the minimal number of measurements needed 145 , 146 assuming axial symmetry of diffusion properties in the voxel. 147 DKI and DTI rely on an empirical representation of the diffusion signal and make no assumptions about the underlying microstructure or tissue properties 8 and are, therefore, widely applicable.
q‐t coverage recommendations for tractography: current tractography methods are less sensitive to scan parameters (b‐values, number of gradient directions) than choices in the tractography pipeline itself (i.e., fiber orientation reconstruction, seeding strategies, streamline propagations, etc.). 57 , 62 , 148 , 149 , 150 , 151 , 152 Our recommended protocol includes 50 to 60 directions at a moderate‐to‐high b‐value. 153 This protocol is also compatible with tools such as “tractogram filtering” and “microstructure‐informed” tractography, 154 , 155 , 156 , 157 , 158 , 159 which are expected to increase anatomical accuracy of tractography. Note a Cartesian sampling of q‐space, known as diffusion spectrum imaging (DSI) can also be used. 160 , 161
Guidelines for acquisition in the perspective of compartment modeling analysis 9 , 162 , 163 are generally the same as in humans, with one nuance: as mentioned, preclinical scanner hardware may allow the exploration of regions of q‐t space that are not achievable on clinical systems. Therefore, the data requirements of some biophysical models may be better met for small animal imaging than human imaging.
Shorter diffusion times are typically favored or enforced when special effort is put into minimizing the TE. These differences may pose additional challenges when extrapolating results obtained in small animals to humans. We, therefore, underline the importance of reporting the diffusion time as part of the acquisition parameters, even when the diffusion time dependency is not the focus of the study. As mentioned earlier, diffusion metrics measured at typically short diffusion times (10–20 ms) in preclinical experiments can be different to those measured in clinical studies with substantially longer diffusion times (typically longer than 50 ms) because they will be sensitive to different aspects and spatial scales of the micro‐environment.
Preclinical scanners offer a unique opportunity to investigate diffusion time‐dependence of diffusivity D(t) or kurtosis K(t) over diffusion time ranges that are difficult to achieve on clinical systems (in particular, short diffusion times either using OGSE or PGSE), concomitantly with the exploration of high b‐values. 130 , 131 , 132 , 164 , 165 , 166 , 167 , 168 For studies spanning short to intermediate diffusion times (up to ˜40–50 ms) we recommend to keep the TE constant across diffusion times. Indeed, except for a combined diffusion‐relaxometry model, accounting for variable T2‐weighting considerably complicates the data analysis. We underline this constant TE recommendation as it is commonly (and unfortunately) not the primary choice because of SNR considerations. For longer diffusion times (>80 ms), a STEAM sequence can be used. 113 , 169
Beyond the brain, organs such as the liver are highly vascularized and feature strong intra‐voxel incoherent motion (IVIM) effects. The anisotropy of the dMRI signal is, however, much smaller than in the brain, so that directional schemes based on three mutually orthogonal diffusion directions can characterize tissue diffusion properties well in most cases. 170 Furthermore, cell sizes are much larger than in the brain (e.g., 20–40 μm for hepatocytes 25 , 171 ), implying that (1) the diffusion times need to be increased relative to brain dMRI to reach long‐time limits; and (2) neglecting cell radius (i.e., using zero‐radius approximations 172 ) can lead to inaccurate intra‐cellular signal representations.
3.5.1. Other practical considerations
3.5.1.1. Order randomization
For studies including the acquisition of multiple b‐values, it may be convenient to randomize the order of the acquisition of the DW images, so that blocks of highly DW measurements are not acquired at once. Interspacing weaker and stronger diffusion weighting minimizes the risk of gradients overheating and reduces the duty cycle.
3.5.1.2. Interspersed b = 0 for drift control
Interspersed b = 0 images are a very effective way of controlling for temperature fluctuations, scanner stability, and image quality throughout long acquisitions. 173 A slow drift in b = 0 amplitudes across time can be corrected by using detrending, applied to all DW images. When diffusion data is acquired in multiple experiments, it is also important to ensure that the adjustment parameters (reference power, receiver gain, etc.) are consistent, ideally by preventing them from being updated between scans.
3.5.1.3. Full‐sphere directional coverage
It is recommended to optimize the distribution of diffusion‐encoding directions, as done for humans dMRI. Directions should be distributed across all shells (i.e., using electrostatic repulsion within and between shells) and should cover the full sphere instead of the half‐sphere. 140 , 141 This coverage is optimal unless there is a specific need to acquire the same directions on each shell, for directional fits of diffusivity and kurtosis for instance. The recommended schemes cannot usually be generated by the vendor software and should be generated separately and imported into the system as a custom gradient direction file (see Section 5.1 on open source resources, and https://github.com/ecaruyer/qspace, in particular).
3.5.1.4. Effective b‐matrix
It is crucial to use the effective b‐matrix for dMRI analysis, rather than the nominal one. The effective b‐matrix is typically provided in an output file collecting all acquisition parameters. For non‐vendor sequences, it may need to be calculated directly using the sequence diagram and all known gradients played in the sequence. Ice water 174 and other pure liquids, particularly those with low diffusivities (see in Fieremans and Lee 181 ) can be useful phantoms to assess whether the correct b‐matrix is used. Such phantoms can also be used to measure the effect of gradient spatial nonlinearity on the effective b‐matrix across the whole imaging field, as well as to test for spurious “diffusion time‐dependence” from scanner drifts, etc. It is also recommended to include the effective b‐matrix when reporting methods, to improve between‐site comparisons, and therefore, increase the value of animal study results toward clinical translation and validation.
3.5.2. Where future work should lie
Preclinical MRI vendors are encouraged to implement diffusion product sequences where the default settings account for the practical considerations mentioned above.
The harmonization of DTI acquisition protocols (e.g., as to the choice of a maximum b = 1000 s/mm2 in vivo) may help multisite reproducibility and comparison studies. Notwithstanding, encouraging the community to acquire richer datasets by default (e.g., multi‐shell at minimum, but also multiple diffusion times and multi‐dimensional encoding) can open up many avenues for testing new models retrospectively on public datasets, in a variety of animal models, healthy and diseased.
The development of biophysical models of tissue should uphold high standards in terms of accuracy and precision of microstructural features estimated and validated using complementary techniques such as light microscopy.
Finally, the flexibility associated with preclinical MRI scanners will hopefully foster further developments in terms of novel diffusion encoding and acquisition techniques to bring dMRI ever closer to in vivo histology.
3.6. Spatial resolution
The image spatial resolution is a critical decision in any experimental process. Although brain dimensions vary by orders of magnitude across species from the mouse (0.4 mL) to human (1300 mL), the relative size of voxels to the size of the brain are generally consistent across many species. Put simply, spatial resolution should be as high as permissible for the targeted SNR and scan time.
Anisotropic resolution, with thicker slices than in‐plane voxel size, is the most widespread design because it is fast and less gradient demanding, while yielding higher SNR than isotropic resolution. Depending on the application, isotropic resolution may, however, be warranted, for example, for tractography and for interpretation of morphological details and anatomical boundaries. Thick slices will introduce more partial volume effects and can challenge the quality of image registration.
Below we provide typical volumes of brains, and compute what the equivalent voxel size (i.e., the volume equivalent resolution) would be given the ratio of volumes, and a typical 2‐mm isotropic human scan (Table 1). We have chosen 2‐mm isotropic as a “standard” only for comparison purposes, and note that larger voxel sizes (2.5‐mm or 3‐mm isotropic) are common in clinical dMRI, whereas smaller voxels are also possible with novel acquisition strategies 182 , 183 , 184 , 185 or stronger gradients (<1‐mm isotropic). Similar figures hold for other organs used in dMRI literature. 186
TABLE 1.
Summary of brain volumes of various species, matching spatial resolutions to a typical human dMRI, and ranges of in vivo spatial resolutions from the literature.
| Species | Brain volume (mL) | Matching spatial resolution (isotropic) | Reported in literature (in vivo) | WM/GM volume ratio |
|---|---|---|---|---|
| Human | 1200 | 2 mm | 1–3 mm isotropic | ˜55/45 |
| Mouse | 0.4 | 140 μm |
100–200 μm in‐plane 200–300 μm slice thickness “Extreme” datasets: 75–125 μm isotropic |
˜8/92 |
| Rat | 1.7 | 225 μm |
100–300 μm in‐plane 250–600 μm slice thickness |
˜13/87 |
| Squirrel monkey | 35 | 600 μm |
600–700 μm in‐plane 1 mm slice thickness |
˜37/63 |
| Macaque | 80 | 800 μm |
500 μm–1 mm in‐plane 1–2 mm slice thickness “Extreme” datasets: 580 μm isotropic |
˜47/53 |
Notes: A few references are provided, but are not comprehensive. Resolutions reported in literature for human, 175 mouse, 14 , 79 rat, 166 , 176 squirrel monkey, 177 macaque. 15 , 178 , 179 WM/GM volume ratio are reported in Ventura‐Antunes et al. 180 where GM volume is a measure of total cortical volume.
Abbreviations: dMRI, diffusion MRI; GM, gray matter; WM, white matter.
4. DATA PROCESSING
We refer to preprocessing as steps that come before any diffusion fitting (tensors, biophysical models, etc.). Preprocessing includes data conversion (e.g., from DICOM format ‐ Digital Imaging and Communications in Medicine, to NIfTI format ‐ Neuroimaging Informatics Technology Initiative), noise reduction, artifact correction/mitigation, or any step that aims at improving data quality. Processing refers to diffusion data fitting and normalization to standard space.
4.1. Preprocessing pipeline
4.1.1. Brain
Generally, preprocessing diffusion datasets of preclinical acquisitions is similar to that of the in vivo human brain. Below we detail the steps associated with a typical preprocessing pipeline, stressing in particular what may differentiate in vivo small‐animal from human implementations, and how available tools can/should be adapted accordingly.
Preclinical scanner software often outputs data in their own vendor‐specific format, with recent versions offering the possibility to export the data as DICOM or NIfTI directly. Overall, explicit conversion by the user to one of the aforementioned formats—typically using in‐house written code—is still widespread, which entails possible incompatibilities with Brain Imaging Data Structure (BIDS) format, data sharing and processing multicenter data. Some solutions such as DICOMIFIER 187 exist, and the adoption of a standard tool by the community—or by the vendors—will greatly aid data harmonization.
The definition of diffusion gradient directions may not be consistent across vendors or across in‐house written data conversion pipelines, with some given in the “imaging frame,” for instance, in relation to readout, phase encode, slice direction (or second phase‐encode direction) and others in the “lab‐frame” with Z being typically along the direction of the main magnetic field. The orientation of the images with respect to the applied diffusion directions is very important, particularly for tractography and should be checked carefully. Tools are also available to systematically correct any errors. 188 , 189
Similarly to in vivo human diffusion imaging, the recommended data preprocessing pipeline includes: reduction of random noise (“denoising”), 190 Gibbs ringing correction, 191 , 192 , 193 combined eddy‐current, motion and susceptibility distortion correction, 194 along with gradient nonlinearity correction (if applicable), Rician bias correction, and signal drift correction because of scanner instabilities. 173 , 195 Recent examples of the concatenation of these processing steps into a pipeline is DESIGNER and PreQual, 196 , 197 or the preprocessing implementation in MRTrix3. 198
We briefly recapitulate a few common pitfalls and/or quality checks, and we refer the reader to the references cited above for comprehensive descriptions of the techniques and their applicability.
The very first prerequisite for most preprocessing steps is providing a brain mask, which is a weakness of non‐human brain preprocessing pipelines. This can be the consequence of either algorithms using inappropriate priors for non‐human brain anatomy in atlas‐based brain masking (e.g., very different shapes and/or sizes between human and rodent) or a consequence of bias fields (inhomogeneous B1 receive field for surface coils and potentially transmit field when using surface emitters), which strongly affect the performance of intensity‐based brain masking. Bias field correction on a b = 0 image can be performed with a variety of software, but should be used for the sole purpose of brain extraction and not as input for the remainder of the preprocessing and processing pipeline. Dedicated tools to perform brain extraction using registration to a matching species atlas are also available (e.g., https://github.com/jlohmeier/atlasBREX 199 , 200 ). If an atlas database for the species and MR contrast of interest is available, the multi‐atlas label fusion segmentation approach performs very well. 201 , 202 More recently, deep‐learning‐based frameworks have been developed and validated to identify the MR image boundaries of the brains of rodents and non‐human primates. 203 , 204 , 205 Finally, in the early preprocessing steps the brain mask could be inflated to yield a generous brain inclusion, making sure it encompasses distortions and motion that have not yet been corrected. At the end of the pipeline, a second, more refined brain masking may be performed.
Denoising aims at reducing random noise (i.e., random fluctuations or Nyquist‐Johnson noise [and its digital counterpart]), in contrast to physiological noise or any other structured unwanted signal contribution (e.g., cardiac or respiratory fluctuations). A principal component analysis can be used to denoise a 4D stack of DW images. 206 The differentiation between signal‐ and noise‐carrying principal components has recently been automated by adopting principles from random matrix theory. 190 This technique requires that (1) the noise level is constant and uncorrelated across all DW images and (2) that the number of DW images is large—the suggested use is 30 images or more. If such requirements are not met, then alternative denoising strategies are presented. 207 , 208 Various supervised, unsupervised, and self‐supervised machine learning‐based techniques have recently been developed and evaluated for the denoising of such data. 209 Inspecting the residuals between the raw and denoised data for absence of structural content is a good quality check.
The implementation of Gibbs ringing correction 191 , 192 has a large positive impact on microstructure model estimates, where the “corruption” of voxels by neighboring CSF can change the apparent microstructure composition dramatically, but has very little impact on the estimation of the fiber orientation distribution for tractography purposes. 191 , 210 , 211 One common limitation is the use of partial Fourier for the acquisition, which makes the correction as implemented by Kellner et al. 191 less effective. A new approach for this correction in partial‐Fourier data has been recently developed 192 ; both these methods are suitable for 2D multislice acquisitions.
The “topup” and “eddy” tools in FMRIB's Software Library (FSL), 212 which can correct for susceptibility distortion, eddy current, or motion‐related jitter require two specifics of data acquisition that are often not the default on preclinical scanners. For susceptibility‐distortion correction, a few b = 0 images with reversed phase‐encode direction should be acquired to enable the calculation of the distortion field. If these images are not available, alternative distortion correction methods might include nonlinear registration to undistorted anatomical images or correction using a fieldmap (B0 map). Furthermore, for eddy current correction, “eddy” requires diffusion directions that are distributed over the entire sphere, and not the half‐sphere. If this sampling is not available in the product sequence, a custom diffusion direction file should be provided for the acquisition. Finally, it is important to note that default FSL parameters are suitable for human dMRI and need to be tuned to the sample of interest in preclinical imaging (e.g., the resolution or knot‐spacing of warp fields for topup, or any parameters that are dependent on spatial scale).
Rician bias correction consists of correcting the diffusion signal decay by subtracting the non‐zero Rician floor. For software and methods, see Ades‐Aron et al., 196 Koay and Basser, 213 and Section 5.1.1. One substantial advantage of preclinical MRI data is that coils are often single‐channel or quadrature recombined, and the complex‐valued data is more easily retrievable from the scanner. Complex‐valued data from a single‐channel coil is by design characterized by Gaussian noise. Rician bias can be, therefore, minimized by denoising in complex space and possibly also circumvented entirely by working with real‐valued data after phase unwrapping. 214
Finally, temporal instability on the scanner because of magnet drift or gradient heating can be measured and corrected by collecting multiple b = 0 images throughout the scan (see Section 3.5). Although this is not commonly done in the literature, we advocate for instability correction (methodology and code are described in Vos et al. 173 and in Section 5.1.1.)
4.1.2. Spinal cord and other organs
Spinal cord dMRI focuses on white matter, which is located at the periphery (whereas the gray matter is inside). Typical preprocessing steps for spinal cord include:
(1) Segmenting the outer contour of the spinal cord and the gray matter (which also results in white matter mask). This can be achieved using active contour, 215 propagation of a 3D mesh, 216 or deep learning. 217 The two latter methods are available in the Spinal Cord Toolbox. 218 For more details on spinal cord segmentation, please see DeLeener et al. 219
(2) Straightening the spinal cord to have it aligned along the superior–inferior axis. The benefit of this step is to facilitate the registration to a spinal cord template and atlas, and/or for group analysis. Straightening the spinal cord can be done with Spinal Cord Toolbox using an algorithm that preserves the topology of the internal structure of the spinal cord. 220
(3) Registering the spinal cord to an anatomical template. This step is useful for extracting diffusion metrics within specific white matter tracts of the spinal cord (e.g., cortico‐spinal, rubrospinal, and dorsal columns). There exist spinal cord templates and atlases (e.g., a rat spinal cord template). 221
An end‐to‐end analysis pipeline, with documentation, example data, and procedure for manual correction is available at http://spine‐generic.readthedocs.io/. 222 This project is for in vivo human spinal cord, but could be adapted for ex vivo and non‐human species.
dMRI provides key information on microstructural properties also in other organs such as liver, 186 kidneys, 223 , 224 muscle, 225 or heart. 226 Imaging each of these anatomical districts in vivo comes with its own challenges, mainly related to complex motion patterns because of proximity to the lungs, inhomogeneous magnetic fields close to air cavities (e.g., stomach, lungs, and rectum), pulsation effects, intrinsic low SNR because of short T 2 (e.g., liver iron). Typical preprocessing steps used for brain MRI can also be useful in these anatomical areas (e.g., denoising, motion and distortion correction), although at present there is still a lack of processing packages tailored for these applications.
4.1.3. Where future work should lie
Brain extraction is an important preprocessing step that, if inaccurate, can largely affect the performance of downstream steps. Preprocessing tools, at each step of the pipeline, should account for geometric and anatomical differences between species, and studies should be performed to optimize and standardize these tools depending on species. Finally, setting up a publicly available pipeline that integrates these preprocessing steps seamlessly, with optimized parameters for each species would be highly beneficial.
4.2. Processing pipelines
After preprocessing, it is typical to perform voxelwise analysis of the DW measures to output parametric maps of a variety of derived metrics. These parametric maps can undergo subsequent analysis at the region of interest (ROI), individual, or group levels.
DTI, DKI, or biophysical models suited for the tissue of interest (white matter, gray matter, muscle, various tumor types, etc.) can be applied to small‐animal data. 8 , 9 , 162 , 227 , 228 For DTI, many software tools are available—see Section 5.1. Substantially fewer software packages offer diffusion kurtosis estimation 198 and most software does not check for b‐value suitability before DTI or DKI estimation. For biophysical model estimation, dedicated code is usually provided by the model developers.
Once parametric maps of various diffusion metrics are available in native space, it is common to use registration either to import atlas‐based segmentation of brain regions for ROI analysis or to bring individual maps into a common space for voxel‐based comparisons. For this registration/normalization step, typical tools used in human data also work well for animal data, with some customization. For nonlinear registration, for instance, default physical dimensions of warp and smoothing kernels should be scaled to those of small‐animal brains.
4.2.1. Where future work should lie
Similar to preprocessing, free online sharing of processing tools can accelerate the harmonization process, with several efforts going in this direction (see also Section 5.1.1). Moreover, prospective harmonization studies 229 are required to understand and account for inter‐site variability.
4.3. Tractography
The application and use of dMRI‐based fiber tractography to study fiber pathways and wiring diagrams of the brain remain largely the same for small animals as for the in vivo human. 230 The fundamentals of tractography (deterministic and/or probabilistic algorithms) also remain the same. In our experience, the only required change is the brain masking approach (see Section 4.1.1).
4.3.1. Fiber orientation estimation
Minimal changes are needed in voxelwise reconstruction steps: standard approaches that estimate fiber orientation distributions will work adequately in animal model systems (including diffusion tensor imaging, spherical deconvolution, ball and sticks, and more advanced methods), resulting in a field of orientation estimates that can be used for tractography.
4.3.2. Tractography
Several changes are needed in the tractography process itself. For example, with smaller brains and smaller voxel sizes, it is common that the “step size” in tractography algorithms must be reduced, although this will usually be performed by default in many software packages (e.g., MRtrix3, DSI Studio, DIPY, FSL, and ExploreDTI). Often, false positive streamlines are removed through filtering or clustering operations. If thresholding by streamline length (i.e., setting a minimum or maximum length to eliminate spurious or implausibly long streamlines), these thresholds must be adapted to an appropriate measure for each specimen and the pathway or system under investigation. The process of filtering by microstructural measures or the diffusion signal (using algorithms such as LIFE, 159 SIFT, 157 , 158 or COMMIT 156 ), as well as adding anatomical constraints, is also relevant in animal models.
One tractography application is bundle segmentation. Individual fiber pathways, or fascicles, of the brain are virtually dissected to be studied across cohorts or time. This is usually done by using ROIs through which bundles must or must not pass to isolate a desired pathway. The most obvious change for animal models is to consider the species‐specific brain anatomy, and ROIs must be modified in accordance with prior knowledge of the bundle. 231 , 232 , 233 For this reason, many automated or manual protocols for bundle dissection are not readily adaptable for small animals. Although some works have described and created tools for dissection in some species (e.g., macaque, 234 squirrel monkey, 235 and mouse 236 ), common tools and protocols for bundle segmentation in humans 237 , 238 have not yet been adapted. Regarding the analysis of bundles, quantifying microstructure along or within the bundle of interest, 239 , 240 connectivity and shape of the bundles 241 can be done using the same analysis as for human data.
The next common application of tractography is connectome analysis—an analysis of the set of streamlines throughout the entire brain to determine network properties, often using graph‐theoretic measures. Potential differences in connectome analysis include different edges/nodes used to derive the matrix, which will typically be derived from existing templates and atlases. 235 , 242 , 243 , 244 , 245
4.3.3. Where future work should lie
Although the process of tractography in small animals strongly parallels that of human, there are still areas for which no guidelines can be provided. For example, it is unknown what spatial resolution is necessary or optimal in various animal brains.
For the tractography process, it is unclear if specific modifications to the generation of streamlines are needed. For example, it may be necessary to adapt starting/stopping criteria, curvature thresholds, or anisotropy criteria for animals with different gray matter/white matter volumes, different (both more or less complex) geometries, and different expected curvatures or pathways. Additionally, with the benefits of strong fields and high gradients on preclinical magnets comes the ability to image and possibly probe connections within cortical or deep gray matter areas, an area that is relatively unexplored in the human brain, and for which there are little‐to‐no guidelines.
Additionally, few guidelines are provided on optimal regions and region placement for bundle segmentation. Many human analyses rely on regions located in a standard space (typically MNI 152), that have been modified and tailored over the years to continually improve the resulting tractography dissections. Few studies exist that describe appropriate region placement in animal models because of a sparsity of resources dedicated to tractography in the animal models. Future work should lie in creating resources that allow whole brain tractography (possibly informed by anatomical constraints) in various models, followed by atlas‐based labeling (to create nodes/edges for connectome generation), and bundle dissection for pathways of interest.
Tractography is often validated in animal models, but we should strive to understand and quantify differences between tractography‐based measures of tissue orientation, and experimental tract‐tracing methods that visualize specific neural connections. For example, knowledge of complications because of crossing fibers, 246 because of spatial resolution, 247 , 248 bottle‐neck regions of tractography, 57 , 249 , 250 superficial U‐fibers, 251 effects of experimental parameters, 252 and false‐positives and false‐negatives 64 have been elucidated through the use of animal models—and we should continually understand the parallels to the human brain to reliably interpret measures derived from tractography. We also urge investigators to fully document the tractography parameters in their publications for rigor and reproducibility.
4.4. Group‐level analysis
A variety of group‐level analyses are available for preclinical dMRI. The choice between them will be guided by the statistical power (number of animals available vs. expected effect size) and by the study design, whether it is hypothesis‐driven or exploratory.
ROI analyses consist in computing the mean (or median) of a given dMRI metric in an anatomical ROI and testing statistical differences of the ROI‐level values in the variable of interest (groups, timepoints, conditions, etc.). Ideally, to limit bias, the ROI segmentation is performed using registration to an atlas where the structure of interest is segmented (and the segmentation is then propagated back to individual space using the inverse transforms). A good alternative is to register all datasets to a study‐specific template. The ROI can be manually drawn on the template and then also propagated back to individual space. For highly deformable or heterogeneous structures (e.g., viscera or tumors) manual ROI segmentation on each dataset may be unavoidable. Operator bias should be carefully mitigated in such cases. ROI segmentations should always be visually inspected for accuracy and consistency. Corrections for multiple comparisons should be applied if multiple ROIs are considered. ROI‐based group analyses are suitable for low‐powered studies (few animals, weak effect) or hypothesis‐driven studies (the ROI where the effect is expected is known a priori). However, if the effect is very localized, large anatomical ROIs may reduce the power by averaging across voxels where no effect is to be expected.
Voxel‐based analyses consist in registering all quantitative dMRI maps to a common template and identifying clusters of voxels that display a significant difference in the variable of interest. For brain studies, a common tool for this effect is FSL's tract‐based spatial statistics. 240 Voxel‐based analyses are suitable for exploratory studies and for highly powered studies (large cohorts or large effect) because of the strict statistical threshold when correcting for many comparisons (large number of voxels), typically using permutations tests.
The documentation of anatomical location is important for data interpretation, re‐use and comparison across studies, and can be communicated using spatial coordinates or anatomical terms. 253 , 254 Several open access 3D reference brain atlases are available for different species (see Section 5.1.2).
5. PERSPECTIVES
5.1. Open science
5.1.1. Code/software
Challenges with preprocessing and processing pipelines highlighted above can be overcome through code sharing and harmonization of implementations.
To allow for a more dynamic and self‐updating resource center, and facilitate code sharing, we have compiled a (non‐comprehensive) list of available software dedicated to the acquisition and processing of preclinical dMRI data, meant to be updated regularly, on a public repository: https://github.com/Diffusion‐MRI/awesome‐preclinical‐diffusion‐mri.
Updates on available software and tools can be shared between developers and users.
5.1.2. Data sharing and databases
A critical aspect of data sharing is that data should be findable, accessible, interoperable, and reusable, in 2016 formulated as the FAIR principles. 255 These principles are now widely adopted by researchers, universities, funding agencies, and journals.
Standards for naming and organizing folders and files are of key importance for the reusability of shared imaging data. The neuroimaging community, therefore, proposed BIDS, 256 recently endorsed as a standard by the International Neuroinformatics Coordinating Facility (INCF). 257 In brief, using BIDS, data are organized according to contrasts (anat, dwi). File names include relevant suffixes that help researchers and software to identify origin and intention of the files (e.g., “_dwi” is intended for DW analysis). Sidecar JSON files include additional metadata that are relevant for the analysis. Figure 5 illustrates a dataset structured according to BIDS. Although the BIDS standard has originally been motivated by the brain functional MRI community, this standard is being actively expanded to accommodate more MR techniques and modalities, the latest of which also include advanced DW imaging. 258 Likewise relevant are recent initiatives for incorporating animal data into the BIDS standard (https://bids.neuroimaging.io/bep032). In the perspective of increasing data sharing opportunities, as well as generating traceable and comparable datasets, we strongly encourage organizing raw preclinical data using the BIDS format. In addition to facilitating data sharing, data organization standards like BIDS help designing applications that know where to look for input data. This ultimately helps automating analysis tasks and creating pipelines. A list of BIDS‐compatible apps is available at https://bids‐apps.neuroimaging.io/apps/.
FIGURE 5.

Illustration of a Brain Imaging Data Structure (BIDS) structured dataset (right) starting from vendor‐specific convention of data organization (left). From Gorgolewski et al. 256
Platforms that could serve as a repository for preclinical datasets include OSF (https://osf.io/), OpenNeuro (https://openneuro.org/), Zenodo (https://zenodo.org/), NITRC (https://www.nitrc.org/) and others (https://odc‐tbi.org/). The EBRAINS research infrastructure for brain‐related research (http://ebrains.eu/) offers solutions for sharing curated data sets with standardized metadata, and links to brain atlases, analytic tools, and solutions for computational modeling and simulation.
To exemplify sharing and reuse of useful imaging data, we compiled a (non‐comprehensive) list of links to selected publicly available small‐animal or ex vivo DW datasets: https://github.com/Diffusion‐MRI/awesome‐preclinical‐diffusion‐mri.git.
5.1.3. Where future work should lie
Code can be hosted on platforms such as GitHub, GitLab, Zenodo, NITRC etc. Hosting code via these tools is not only beneficial for the community, but also for the code developers themselves (and their respective research groups). This ensures code safekeeping, retrieving, and versioning. Nevertheless, code sharing and submission to hosting platforms comes with the responsibilities of documenting, cleaning, packaging, testing, and versioning the code. These duties come at a (high) cost of requiring an in situ software engineer. Initiatives aimed at allocating special resources for software maintenance via funding bodies are urgently needed.
For licensing open source code, most permissive licenses include MIT and BSD licenses. It means that the code can be reused by any entity (person or company), and importantly to note, is that the modified code can be distributed as closed source. If you wish to enforce the disclosure of your open source code, there are so‐called “copyleft” licenses, such as the GNU GPLv3 and the Mozilla Public License 2.0. For more details, see https://choosealicense.com/licenses/.
Certainly one of the highest aims is to propose a successful, transparent, and comprehensive analysis framework that promotes reproducibility.
The amount of open‐source code and data is overwhelming. Sharing code and data is a double‐edged sword. Indeed, public sharing of scientific objects that do not meet certain standards or requirements can do more harm than good. It is crucial to keep code on a dedicated platform (e.g., GitHub) and point to a specific tag or commit hashtag directly in the associated paper and OSF data repository. In parallel, it is important to version‐track the dataset itself and mention specific versions where appropriate. Several software solutions exist to link data objects and code and track provenance, for example Datalad (https://www.datalad.org/) and the YODA framework (https://handbook.datalad.org/en/latest/basics/101‐127‐yoda.html).
5.2. The future: What should we strive to achieve?
As a field, we should continually strive to achieve reduced barriers to entry for new imaging centers, new scientists, and new industries who aim to use dMRI in a preclinical setting. Toward this end, as a community, we should promote dissemination of knowledge, code, and datasets to achieve high standards of data quality and analysis, reproducibility, and transparency. We should foster academic and industrial collaborations with MR vendors, as well as reduce globally the time and cost of research in this field.
Supporting information
Data S1: Supplementary Information.
ACKNOWLEDGMENTS
We acknowledge financial support from the National Institutes of Health (K01EB032898, R01AG057991, R01NS 125020, R01EB017230, R01EB019980, R01EB031954, R01 CA160620, R01NS109090, R01NS119605, U54AG054349, P50MH096889); the National Institute of Biomedical Imaging and Bioengineering (R01EB031765, R56EB031765); the National Institute on Drug Abuse (P30DA048742); the Secretary of Universities and Research (Government of Catalonia) Beatriu de Pinós postdoctoral fellowship (2020 BP 00117); “la Caixa” Foundation (ID 100010434); the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska‐Curie grant agreement no. 847648; Junior Leader fellowship codes (LCF/BQ/PR22/11920010; CF/BQ/PI20/11760029); the European Union's Horizon Europe Programme for Research Infrastructures under the specific grant agreement no. 101147319 (EBRAINS 2.0); the Research Council of Norway under grant agreement no. 333157 (INCF Norwegian Node 2022‐2027); the Research Foundation Flanders (FWO: 12M3119N); the Belgian Science Policy Prodex (Grant ISLRA 2009–1062); the μNEURO Research Center of Excellence of the University of Antwerp, the Institutional research chair in Neuroinformatics (Sherbrooke, Canada); the NSERC Discovery Grant; the European Research Council Consolidator grant (101044180); the Canada Research Chair in Quantitative Magnetic Resonance Imaging (950‐230815); the Canadian Institute of Health Research (CIHR FDN‐143263); the Canada Foundation for Innovation (32454, 34824); the Fonds de Recherche du Québec ‐ Santé (322736); the Natural Sciences and Engineering Research Council of Canada (RGPIN‐2019‐07244); the Canada First Research Excellence Fund (IVADO and TransMedTech); the Courtois NeuroMod project; the Quebec BioImaging Network (5886, 35450); the Mila‐Tech Transfer Funding Program; and the Swiss National Science Foundation (Eccellenza Fellowship PCEFP2_194260).
Jelescu IO, Grussu F, Ianus A, et al. Considerations and recommendations from the ISMRM diffusion study group for preclinical diffusion MRI: Part 1: In vivo small‐animal imaging. Magn Reson Med. 2025;93:2507‐2534. doi: 10.1002/mrm.30429
Ileana O. Jelescu and Kurt G. Schilling contributed equally to this work.
Data Availability Statement
Data sharing is not applicable to this article as no new data were created or analyzed in this study.
REFERENCES
- 1. Schilling KG, Grussu F, Ianus A, et al. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 – Ex vivo imaging: added value and acquisition. Magn Reson Med. 2025;93:2535‐2560. 10.1002/mrm.30435 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Schilling KG, Amy FDH, Grussu F, et al. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3 – Ex vivo imaging: data processing, comparisons with microscopy, and tractography. Magn Reson Med. 2025;93:2561‐2582. 10.1002/mrm.30424 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Moseley ME, Kucharczyk J, Mintorovitch J, et al. Diffusion‐weighted MR imaging of acute stroke: correlation with T2‐weighted and magnetic susceptibility‐enhanced MR imaging in cats. AJNR Am J Neuroradiol. 1990;11:423‐429. [PMC free article] [PubMed] [Google Scholar]
- 4. Basser PJ, Mattiello J, LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys J. 1994;66:259‐267. doi: 10.1016/s0006-3495(94)80775-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Jones DK. Diffusion MRI: Theory, Methods, and Application . 2010.
- 6. Moseley ME, Cohen Y, Kucharczyk J, et al. Diffusion‐weighted MR imaging of anisotropic water diffusion in cat central nervous system. Radiology. 1990;176:439‐445. [DOI] [PubMed] [Google Scholar]
- 7. Dyrby TB, Innocenti GM, Bech M, Lundell H. Validation strategies for the interpretation of microstructure imaging using diffusion MRI. Neuroimage. 2018;182:62‐79. [DOI] [PubMed] [Google Scholar]
- 8. Jelescu IO, Budde MD. Design and validation of diffusion MRI models of white matter. Front Phys. 2017;28. doi: 10.3389/fphy.2017.00061 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Jelescu IO, Palombo M, Bagnato F, Schilling KG. Challenges for biophysical modeling of microstructure. J Neurosci Methods. 2020;344:108861. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Iima M, Reynaud O, Tsurugizawa T, et al. Characterization of glioma microcirculation and tissue features using intravoxel incoherent motion magnetic resonance imaging in a rat brain model. Invest Radiol. 2014;49:485‐490. [DOI] [PubMed] [Google Scholar]
- 11. Barazany D, Basser PJ, Assaf Y. In vivo measurement of axon diameter distribution in the corpus callosum of rat brain. Brain. 2009;132:1210‐1220. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Caruyer E, Lenglet C, Sapiro G, Deriche R. Design of multishell sampling schemes with uniform coverage in diffusion MRI. Magn Reson Med. 2013;69:1534‐1540. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Szczepankiewicz F, Westin CF, Nilsson M. Gradient waveform design for tensor‐valued encoding in diffusion MRI. J Neurosci Methods. 2021;348:109007. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Wu D, Xu J, McMahon MT, et al. In vivo high‐resolution diffusion tensor imaging of the mouse brain. Neuroimage. 2013;83:18‐26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Grier MD, Yacoub E, Adriany G, et al. Ultra‐high field (10.5 T) diffusion‐weighted MRI of the macaque brain. Neuroimage. 2022;255:119200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Mishra A, Wang F, Chen LM, Gore JC. Longitudinal changes in DTI parameters of specific spinal white matter tracts correlate with behavior following spinal cord injury in monkeys. Sci Rep. 2020;10:17316. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Takemura H, Pestilli F, Weiner KS. Comparative neuroanatomy: integrating classic and modern methods to understand association fibers connecting dorsal and ventral visual cortex. Neurosci Res. 2019;146:1‐12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Krubitzer L, Kaas J. The evolution of the neocortex in mammals: how is phenotypic diversity generated? Curr Opin Neurobiol. 2005;15:444‐453. [DOI] [PubMed] [Google Scholar]
- 19. Striedter GF, Bullock TH, Preuss TM, Rubenstein J, Krubitzer LA. Evolution of Nervous Systems. Academic Press; 2016. [Google Scholar]
- 20. Wang SSH, Wang S‐H, Shultz JR, et al. Functional trade‐offs in White matter axonal scaling. J Neurosci. 2008;28:4047‐4056. doi: 10.1523/jneurosci.5559-05.2008 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Caminiti R, Ghaziri H, Galuske R, Hof PR, Innocenti GM. Evolution amplified processing with temporally dispersed slow neuronal connectivity in primates. Proc Natl Acad Sci U S A. 2009;106:19551‐19556. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Mota B, Dos Santos SE, Ventura‐Antunes L, et al. White matter volume and white/gray matter ratio in mammalian species as a consequence of the universal scaling of cortical folding. Proc Natl Acad Sci U S A. 2019;116:15253‐15261. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Jeurissen B, Tournier JD, Dhollander T, Connelly A, Sijbers J. Multi‐tissue constrained spherical deconvolution for improved analysis of multi‐shell diffusion MRI data. Neuroimage. 2014;103:411‐426. [DOI] [PubMed] [Google Scholar]
- 24. Imamura H, Kawasaki S, Shiga J, Bandai Y, Sanjo K, Idezuki Y. Quantitative evaluation of parenchymal liver cell volume and total hepatocyte number in cirrhotic patients. Hepatology. 1991;14:448‐453. [PubMed] [Google Scholar]
- 25. Martin NC, McCullough CT, Bush PG, Sharp L, Hall AC, Harrison DJ. Functional analysis of mouse hepatocytes differing in DNA content: volume, receptor expression, and effect of IFNgamma. J Cell Physiol. 2002;191:138‐144. [DOI] [PubMed] [Google Scholar]
- 26. Dolenšek J, Rupnik MS, Stožer A. Structural similarities and differences between the human and the mouse pancreas. Islets. 2015;7:e1024405. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Steiniger BS. Human spleen microanatomy: why mice do not suffice. Immunology. 2015;145:334‐346. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. Becker AJ. Review: animal models of acquired epilepsy: insights into mechanisms of human epileptogenesis. Neuropathol Appl Neurobiol. 2018;44:112‐129. doi: 10.1111/nan.12451 [DOI] [PubMed] [Google Scholar]
- 29. Hajiaghamemar M, Seidi M, Oeur RA, Margulies SS. Toward development of clinically translatable diagnostic and prognostic metrics of traumatic brain injury using animal models: a review and a look forward. Exp Neurol. 2019;318:101‐123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Rumpel H, Nedelcu J, Aguzzi A, Martin E. Late glial swelling after acute cerebral hypoxia‐ischemia in the neonatal rat: a combined magnetic resonance and histochemical study. Pediatr Res. 1997;42:54‐59. [DOI] [PubMed] [Google Scholar]
- 31. Wu D, Martin LJ, Northington FJ, Zhang J. Oscillating‐gradient diffusion magnetic resonance imaging detects acute subcellular structural changes in the mouse forebrain after neonatal hypoxia‐ischemia. J Cereb Blood Flow Metab. 2019;39:1336‐1348. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Guglielmetti C, Veraart J, Roelant E, et al. Diffusion kurtosis imaging probes cortical alterations and white matter pathology following cuprizone induced demyelination and spontaneous remyelination. Neuroimage. 2016;125:363‐377. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Kelm ND, West KL, Carson RP, Gochberg DF, Ess KC, Does MD. Evaluation of diffusion kurtosis imaging in ex vivo hypomyelinated mouse brains. Neuroimage. 2016;124:612‐626. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Mac Donald CL, Dikranian K, Bayly P, Holtzman D, Brody D. Diffusion tensor imaging reliably detects experimental traumatic axonal injury and indicates approximate time of injury. J Neurosci. 2007;27:11869‐11876. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Hutchinson EB, Schwerin SC, Radomski KL, et al. Detection and distinction of mild brain injury effects in a ferret model using diffusion tensor MRI (DTI) and DTI‐driven tensor‐based morphometry (D‐TBM). Front Neurosci. 2018;12:573. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Wallace EJ, Mathias JL, Ward L. Diffusion tensor imaging changes following mild, moderate and severe adult traumatic brain injury: a meta‐analysis. Brain Imaging Behav. 2018;12:1607‐1621. [DOI] [PubMed] [Google Scholar]
- 37. Eierud C, Craddock RC, Fletcher S, et al. Neuroimaging after mild traumatic brain injury: review and meta‐analysis. Neuroimage Clin. 2014;4:283‐294. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Chenevert TL, Stegman LD, Taylor JM, et al. Diffusion magnetic resonance imaging: an early surrogate marker of therapeutic efficacy in brain tumors. J Natl Cancer Inst. 2000;92:2029‐2036. [DOI] [PubMed] [Google Scholar]
- 39. Hamstra DA, Lee KC, Moffat BA, Chenevert TL, Rehemtulla A, Ross BD. Diffusion magnetic resonance imaging: an imaging treatment response biomarker to chemoradiotherapy in a mouse model of squamous cell cancer of the head and neck. Transl Oncol. 2008;1:187‐194. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40. Jelescu IO, Zurek M, Winters KV, et al. In vivo quantification of demyelination and recovery using compartment‐specific diffusion MRI metrics validated by electron microscopy. Neuroimage. 2016;132:104‐114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41. Moffat BA, Hall DE, Stojanovska J, et al. Diffusion imaging for evaluation of tumor therapies in preclinical animal models. Magma. 2004;17:249‐259. [DOI] [PubMed] [Google Scholar]
- 42. Kim S, Decarlo L, Cho GY, et al. Interstitial fluid pressure correlates with intravoxel incoherent motion imaging metrics in a mouse mammary carcinoma model. NMR Biomed. 2012;25:787‐794. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43. Lesbats C, Kelly CL, Czanner G, Poptani H. Diffusion kurtosis imaging for characterizing tumor heterogeneity in an intracranial rat glioblastoma model. NMR Biomed. 2020;33:e4386. [DOI] [PubMed] [Google Scholar]
- 44. Tristão Pereira C, Diao Y, Yin T, et al. Synchronous nonmonotonic changes in functional connectivity and white matter integrity in a rat model of sporadic Alzheimer's disease. Neuroimage. 2021;225:117498. [DOI] [PubMed] [Google Scholar]
- 45. Eed A, Cerdán Cerdá A, Lerma J, De Santis S. Diffusion‐weighted MRI in neurodegenerative and psychiatric animal models: experimental strategies and main outcomes. J Neurosci Methods. 2020;343:108814. [DOI] [PubMed] [Google Scholar]
- 46. Grier MD, Zimmermann J, Heilbronner SR. Estimating brain connectivity with diffusion‐weighted magnetic resonance imaging: promise and peril. Biol Psychiatry Cogn Neurosci Neuroimaging. 2020;5:846‐854. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47. Sarubbo S, Petit L, De Benedictis A, Chioffi F, Ptito M, Dyrby TB. Uncovering the inferior fronto‐occipital fascicle and its topological organization in non‐human primates: the missing connection for language evolution. Brain Struct Funct. 2019;224:1553‐1567. [DOI] [PubMed] [Google Scholar]
- 48. Mandonnet E, Sarubbo S, Petit L. The nomenclature of human White matter association pathways: proposal for a systematic taxonomic anatomical classification. Front Neuroanat. 2018;12:94. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49. Panesar SS, Fernandez‐Miranda J. Commentary: the nomenclature of human White matter association pathways: proposal for a systematic taxonomic anatomical classification. Front Neuroanat. 2019;13:61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50. Schilling KG, Rheault F, Petit L, et al. Tractography dissection variability: what happens when 42 groups dissect 14 white matter bundles on the same dataset? Neuroimage. 2021;243:118502. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51. Azadbakht H, Parkes LM, Haroon HA, et al. Validation of high‐resolution Tractography against in vivo tracing in the macaque visual cortex. Cereb Cortex. 2015;25:4299‐4309. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52. van den Heuvel MP, de Reus MA, Feldman Barrett L, et al. Comparison of diffusion tractography and tract‐tracing measures of connectivity strength in rhesus macaque connectome. Hum Brain Mapp. 2015;36:3064‐3075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53. Shen K, Goulas A, Grayson DS, et al. Exploring the limits of network topology estimation using diffusion‐based tractography and tracer studies in the macaque cortex. Neuroimage. 2019;191:81‐92. doi: 10.1016/j.neuroimage.2019.02.018 [DOI] [PubMed] [Google Scholar]
- 54. Tang‐Wright K, Smith JET, Bridge H, et al. Intra‐areal visual topography in primate brains mapped with probabilistic Tractography of diffusion‐weighted imaging. Cereb Cortex. 2022;32:2555‐2574. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55. Schilling KG, Petit L, Rheault F, et al. Brain connections derived from diffusion MRI tractography can be highly anatomically accurate‐if we know where white matter pathways start, where they end, and where they do not go. Brain Struct Funct. 2020;225:2387‐2402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56. Gutierrez CE, Skibbe H, Nakae K, et al. Optimization and validation of diffusion MRI‐based fiber tracking with neural tracer data as a reference. Sci Rep. 2020;10:21285. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57. Girard G, Caminiti R, Battaglia‐Mayer A, et al. On the cortical connectivity in the macaque brain: a comparison of diffusion tractography and histological tracing data. Neuroimage. 2020;221:117201. [DOI] [PubMed] [Google Scholar]
- 58. Thomas C, Ye FQ, Irfanoglu MO, et al. Anatomical accuracy of brain connections derived from diffusion MRI tractography is inherently limited. Proc Natl Acad Sci U S A. 2014;111:16574‐16579. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59. Donahue CJ, Sotiropoulos SN, Jbabdi S, et al. Using diffusion Tractography to predict cortical connection strength and distance: a quantitative comparison with tracers in the monkey. J Neurosci. 2016;36:6758‐6770. doi: 10.1523/jneurosci.0493-16.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. Schilling KG, Nath V, Hansen C, et al. Limits to anatomical accuracy of diffusion tractography using modern approaches. Neuroimage. 2019;185:1‐11. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61. Yan M, Yu W, Lv Q, et al. Mapping brain‐wide excitatory projectome of primate prefrontal cortex at submicron resolution and comparison with diffusion tractography. Elife. 2022;11. doi: 10.7554/eLife.72534 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62. Maffei C, Girard G, Schilling KG, et al. Insights from the IronTract challenge: optimal methods for mapping brain pathways from multi‐shell diffusion MRI. Neuroimage. 2022;257:119327. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63. Grisot G, Haber SN, Yendiki A. Diffusion MRI and anatomic tracing in the same brain reveal common failure modes of tractography. Neuroimage. 2021;239:118300. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64. Dyrby TB, Søgaard LV, Parker GJ, et al. Validation of in vitro probabilistic tractography. Neuroimage. 2007;37:1267‐1277. [DOI] [PubMed] [Google Scholar]
- 65. Sauleau P, Lapouble E, Val‐Laillet D, Malbert CH. The pig model in brain imaging and neurosurgery. Animal. 2009;3:1138‐1151. doi: 10.1017/s1751731109004649 [DOI] [PubMed] [Google Scholar]
- 66. Ryan MC, Sherman P, Rowland LM, et al. Miniature pig model of human adolescent brain white matter development. J Neurosci Methods. 2018;296:99‐108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67. Wang R, Weng G, Yu S, Dai S, Zhang W, Zhu F. Diffusion‐weighted imaging detects early brain injury after hypothermic circulatory arrest in pigs. Interact Cardiovasc Thorac Surg. 2018;26:687‐692. [DOI] [PubMed] [Google Scholar]
- 68. Bech J, Orlowski D, Glud AN, Dyrby TB, Sørensen JCH, Bjarkam CR. Ex vivo diffusion‐weighted MRI tractography of the Göttingen minipig limbic system. Brain Struct Funct. 2020;225:1055‐1071. [DOI] [PubMed] [Google Scholar]
- 69. Hutchinson EB, Schwerin SC, Radomski KL, Irfanoglu MO, Juliano SL, Pierpaoli CM. Quantitative MRI and DTI abnormalities during the acute period following CCI in the ferret. Shock. 2016;46:167‐176. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70. Delettre C, Messé A, Dell LA, et al. Comparison between diffusion MRI tractography and histological tract‐tracing of cortico‐cortical structural connectivity in the ferret brain. Netw Neurosci. 2019;3:1038‐1050. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71. Hamaide J, De Groof G, Van Steenkiste G, et al. Exploring sex differences in the adult zebra finch brain: in vivo diffusion tensor imaging and ex vivo super‐resolution track density imaging. Neuroimage. 2017;146:789‐803. [DOI] [PubMed] [Google Scholar]
- 72. Assaf Y, Bouznach A, Zomet O, Marom A, Yovel Y. Conservation of brain connectivity and wiring across the mammalian class. Nat Neurosci. 2020;23:805‐808. [DOI] [PubMed] [Google Scholar]
- 73. Haase A, Odoj F, Von Kienlin M, et al. NMR probeheads forin vivo applications. Concepts Magn Reson. 2000;12:361‐388. [Google Scholar]
- 74. Doty FD, Entzminger G, Kulkarni J, Pamarthy K, Staab JP. Radio frequency coil technology for small‐animal MRI. NMR Biomed. 2007;20:304‐325. [DOI] [PubMed] [Google Scholar]
- 75. Sutton BP, Ciobanu L, Zhang X, Webb A. Parallel imaging for NMR microscopy at 14.1 tesla. Magn Reson Med. 2005;54:9‐13. [DOI] [PubMed] [Google Scholar]
- 76. Papoti D, Yen CCC, Mackel JB, Merkle H, Silva AC. An embedded four‐channel receive‐only RF coil array for fMRI experiments of the somatosensory pathway in conscious awake marmosets. NMR Biomed. 2013;26:1395‐1402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77. Junge S. Cryogenic and superconducting coils for MRI. Encyclopedia of Magnetic Resonance. John Wiley & Sons, Ltd.; 2012. doi: 10.1002/9780470034590.emrstm1162 [DOI] [Google Scholar]
- 78. Niendorf T, Pohlmann A, Reimann HM, et al. Advancing cardiovascular, neurovascular, and renal magnetic resonance imaging in small rodents using cryogenic radiofrequency coil technology. Front Pharmacol. 2015;6:255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79. Yon M, Bao Q, Chitrit OJ, Henriques RN, Shemesh N, Frydman L. High‐resolution 3D in vivo brain diffusion tensor imaging at ultrahigh fields: following maturation on juvenile and adult mice. Front Neurosci. 2020;14:590900. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80. Lagore RL, Moeller S, Zimmermann J, et al. An 8‐dipole transceive and 24‐loop receive array for non‐human primate head imaging at 10.5 T. NMR Biomed. 2021;34:e4472. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81. Gilbert KM, Schaeffer DJ, Gati JS, Klassen LM, Everling S, Menon RS. Open‐source hardware designs for MRI of mice, rats, and marmosets: integrated animal holders and radiofrequency coils. J Neurosci Methods. 2019;312:65‐72. [DOI] [PubMed] [Google Scholar]
- 82. Gilbert KM, Gati JS, Klassen LM, et al. A geometrically adjustable receive array for imaging marmoset cohorts. Neuroimage. 2017;156:78‐86. [DOI] [PubMed] [Google Scholar]
- 83. Sotiropoulos SN, Jbabdi S, Xu J, et al. Advances in diffusion MRI acquisition and processing in the human connectome project. Neuroimage. 2013;80:125‐143. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84. Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202‐1210. [DOI] [PubMed] [Google Scholar]
- 85. Chen NK, Guidon A, Chang HC, Song AW. A robust multi‐shot scan strategy for high‐resolution diffusion weighted MRI enabled by multiplexed sensitivity‐encoding (MUSE). Neuroimage. 2013;72:41‐47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86. Guhaniyogi S, Chu ML, Chang HC, Song AW, Chen NK. Motion immune diffusion imaging using augmented MUSE for high‐resolution multi‐shot EPI. Magn Reson Med. 2016;75:639‐652. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87. Mani M, Jacob M, Kelley D, Magnotta V. Multi‐shot sensitivity‐encoded diffusion data recovery using structured low‐rank matrix completion (MUSSELS). Magn Reson Med. 2017;78:494‐507. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88. Alliance QIB. QIBA profile: diffusion‐weighted magnetic resonance imaging (DWI). Profile Consensus (QIBA, 2019). RSNA (Radiological Society of North America); 2020. [Google Scholar]
- 89. Grandjean J, Desrosiers‐Gregoire G, Anckaerts C, et al. A consensus protocol for functional connectivity analysis in the rat brain. Nat Neurosci. 2023;26:673‐681. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90. Phoon CKL, Aristizábal O, Farhoud M, Turnbull DH, Wadghiri YZ. Mouse cardiovascular imaging. Curr Protoc. 2024;4:e1116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91. Schaeffer DJ, Liu C, Silva AC, Everling S. Magnetic resonance imaging of marmoset monkeys. ILAR J. 2020;61:274‐285. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92. Mannheim JG, Kara F, Doorduin J, et al. Standardization of small animal imaging—current status and future prospects. Mol Imaging Biol. 2018;20:716‐731. [DOI] [PubMed] [Google Scholar]
- 93. Saito S, Ueda J. Preclinical magnetic resonance imaging and spectroscopy in the fields of radiological technology, medical physics, and radiology. Radiol Phys Technol. 2024;17:47‐59. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94. Bertalan G, Boehm‐Sturm P, Schreyer S, et al. The influence of body temperature on tissue stiffness, blood perfusion, and water diffusion in the mouse brain. Acta Biomater. 2019;96:412‐420. [DOI] [PubMed] [Google Scholar]
- 95. Holz M, Heil SR, Sacco A. Temperature‐dependent self‐diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements. Phys Chem Chem Phys. 2000;2:4740‐4742. [Google Scholar]
- 96. Tremoleda JL, Macholl S, Sosabowski JK. Anesthesia and monitoring of animals during MRI studies. Methods Mol Biol 2018;1718:423–439, Springer New York. [DOI] [PubMed] [Google Scholar]
- 97. Gakuba C, Gaberel T, Goursaud S, et al. General anesthesia inhibits the activity of the “Glymphatic system.”. Theranostics. 2018;8:710‐722. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98. Lindhardt TB, Skoven CS, Bordoni L, Østergaard L, Liang Z, Hansen B. Anesthesia‐related brain microstructure modulations detected by diffusion magnetic resonance imaging. NMR Biomed. 2024;37:e5033. [DOI] [PubMed] [Google Scholar]
- 99. Zhao G, Han H, Yang J, et al. Brain interstitial fluid drainage and extracellular space affected by inhalational isoflurane: in comparison with intravenous sedative dexmedetomidine and pentobarbital sodium. Sci China Life Sci. 2020;63:1363‐1379. [DOI] [PubMed] [Google Scholar]
- 100. Abe Y, Tsurugizawa T, Le Bihan D. Water diffusion closely reveals neural activity status in rat brain loci affected by anesthesia. PLoS Biol. 2017;15:e2001494. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101. Grandjean J, Schroeter A, Batata I, Rudin M. Optimization of anesthesia protocol for resting‐state fMRI in mice based on differential effects of anesthetics on functional connectivity patterns. Neuroimage. 2014;102:838‐847. [DOI] [PubMed] [Google Scholar]
- 102. Steiner AR, Rousseau‐Blass F, Schroeter A, Hartnack S, Bettschart‐Wolfensberger R. Systematic review: anesthetic protocols and management as confounders in rodent blood oxygen level dependent functional magnetic resonance imaging (BOLD fMRI)‐part B: effects of anesthetic agents, doses and timing. Animals (Basel). 2021;11:199. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103. Yacoub E, Grier MD, Auerbach EJ, et al. Ultra‐high field (10.5 T) resting state fMRI in the macaque. Neuroimage. 2020;223:117349. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 104. Autio JA, Zhu Q, Li X, et al. Minimal specifications for non‐human primate MRI: challenges in standardizing and harmonizing data collection. Neuroimage. 2021;236:118082. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105. Lanzer P, Barta C, Botvinick EH, Wiesendanger HU, Modin G, Higgins CB. ECG‐synchronized cardiac MR imaging: method and evaluation. Radiology. 1985;155:681‐686. [DOI] [PubMed] [Google Scholar]
- 106. Lewis CE, Prato FS, Drost DJ, Nicholson RL. Comparison of respiratory triggering and gating techniques for the removal of respiratory artifacts in MR imaging. Radiology. 1986;160:803‐810. [DOI] [PubMed] [Google Scholar]
- 107. Ehman RL, McNamara MT, Pallack M, Hricak H, Higgins CB. Magnetic resonance imaging with respiratory gating: techniques and advantages. AJR Am J Roentgenol. 1984;143:1175‐1182. [DOI] [PubMed] [Google Scholar]
- 108. Lenz GW, Haacke EM, White RD. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Imaging. 1989;7:445‐455. [DOI] [PubMed] [Google Scholar]
- 109. Cao J, Song HK, Yang H, et al. Respiratory motion mitigation and repeatability of two diffusion‐weighted MRI methods applied to a murine model of spontaneous pancreatic cancer. Tomography. 2021;7:66‐79. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110. Callaghan PT. Principles of Nuclear Magnetic Resonance Microscopy. Clarendon Press; 1993. [Google Scholar]
- 111. Stejskal EO, Tanner JE. Spin diffusion measurements: spin echoes in the presence of a time‐dependent field gradient. J Chem Phys. 1965;42:288‐292. [Google Scholar]
- 112. Merboldt KD, Hänicke W, Frahm J. Diffusion imaging using stimulated echoes. Magn Reson Med. 1991;19:233‐239. [DOI] [PubMed] [Google Scholar]
- 113. Lundell H, Alexander DC, Dyrby TB. High angular resolution diffusion imaging with stimulated echoes: compensation and correction in experiment design and analysis. NMR Biomed. 2014;27:918‐925. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114. Gore JC, Xu J, Colvin DC, Yankeelov TE, Parsons EC, Does MD. Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy. NMR Biomed. 2010;23:745‐756. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115. Cory DG, Garroway AN. Measurement of translational displacement probabilities by NMR: an indicator of compartmentation. Magn Reson Med. 1990;14:435‐444. [DOI] [PubMed] [Google Scholar]
- 116. Callaghan PT. Translational Dynamics and Magnetic Resonance: Principles of Pulsed Gradient Spin Echo NMR. OUP Oxford; 2011. [Google Scholar]
- 117. Ramanna S, Moss HG, McKinnon ET. Triple diffusion encoding MRI predicts intra‐axonal and extra‐axonal diffusion tensors in white matter. Magn Resonan. 2020;83:2209‐2220. doi: 10.1002/mrm.28084 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118. Topgaard D. Multidimensional diffusion MRI. J Magn Reson. 2017;275:98‐113. [DOI] [PubMed] [Google Scholar]
- 119. Cheng Y, Cory DG. Multiple scattering by NMR. J Am Chem Soc. 1999;121:7935‐7936. https://www.cheric.org/research/tech/periodicals/view.php?seq=324720 [Google Scholar]
- 120. Özarslan E. Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR. J Magn Reson. 2009;199:56‐67. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121. Paulsen JL, Özarslan E, Komlosh ME, Basser PJ, Song YQ. Detecting compartmental non‐Gaussian diffusion with symmetrized double‐PFG MRI. NMR Biomed. 2015;28:1550‐1556. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122. Nilsson M, van Westen D, Ståhlberg F, Sundgren PC, Lätt J. The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter. Magma. 2013;26:345‐370. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 123. Ning L, Nilsson M, Lasič S, Westin CF, Rathi Y. Cumulant expansions for measuring water exchange using diffusion MRI. J Chem Phys. 2018;148:074109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 124. Åslund I, Topgaard D. Determination of the self‐diffusion coefficient of intracellular water using PGSE NMR with variable gradient pulse length. J Magn Reson. 2009;201:250‐254. [DOI] [PubMed] [Google Scholar]
- 125. Westin CF, Knutsson H, Pasternak O, et al. Q‐space trajectory imaging for multidimensional diffusion MRI of the human brain. Neuroimage. 2016;135:345‐362. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126. Henriques RN, Palombo M, Jespersen SN, Shemesh N, Lundell H, Ianuş A. Double diffusion encoding and applications for biomedical imaging. J Neurosci Methods. 2021;348:108989. [DOI] [PubMed] [Google Scholar]
- 127. Tyszka JM, Frank LR. High‐field diffusion MR histology: image‐based correction of eddy‐current ghosts in diffusion‐weighted rapid acquisition with relaxation enhancement (DW‐RARE). Magn Reson Med. 2009;61:728‐733. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 128. Aggarwal M, Mori S, Shimogori T, Blackshaw S, Zhang J. Three‐dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain. Magn Reson Med. 2010;64:249‐261. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 129. Duyn JH, Yang Y, Frank JA, van der Veen JW. Simple correction method for k‐space trajectory deviations in MRI. J Magn Reson. 1998;132:150‐153. doi: 10.1006/jmre.1998.1396 [DOI] [PubMed] [Google Scholar]
- 130. Does MD, Parsons EC, Gore JC. Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med. 2003;49:206‐215. [DOI] [PubMed] [Google Scholar]
- 131. Aggarwal M, Smith MD, Calabresi PA. Diffusion‐time dependence of diffusional kurtosis in the mouse brain. Magn Reson Med. 2020;84:1564‐1578. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 132. Pyatigorskaya N, Le Bihan D, Reynaud O, Ciobanu L. Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortex. Magn Reson Med. 2014;72:492‐500. [DOI] [PubMed] [Google Scholar]
- 133. Wu D, Martin LJ, Northington FJ, Zhang J. Oscillating gradient diffusion MRI reveals unique microstructural information in normal and hypoxia‐ischemia injured mouse brains. Magn Reson Med. 2014;72:1366‐1374. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 134. Jespersen SN, Bjarkam CR, Nyengaard JR, et al. Neurite density from magnetic resonance diffusion measurements at ultrahigh field: comparison with light microscopy and electron microscopy. Neuroimage. 2010;49:205‐216. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 135. Sepehrband F, Alexander DC, Kurniawan ND, Reutens DC, Yang Z. Towards higher sensitivity and stability of axon diameter estimation with diffusion‐weighted MRI. NMR Biomed. 2016;29:293‐308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 136. Xu J, Li H, Harkins KD, et al. Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy. Neuroimage. 2014;103:10‐19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 137. Ianuş A, Jespersen SN, Serradas Duarte T, Alexander DC, Drobnjak I, Shemesh N. Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain. Neuroimage. 2018;183:934‐949. [DOI] [PubMed] [Google Scholar]
- 138. Lundell H, Nilsson M, Dyrby TB, et al. Multidimensional diffusion MRI with spectrally modulated gradients reveals unprecedented microstructural detail. Sci Rep. 2019;9:9026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 139. Alexander DC. A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure features. Magn Reson Med. 2008;60:439‐448. [DOI] [PubMed] [Google Scholar]
- 140. Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med. 1999;42:515‐525. doi: 10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q [DOI] [PubMed] [Google Scholar]
- 141. Jones DK. The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study. Magn Reson Med. 2004;51:807‐815. [DOI] [PubMed] [Google Scholar]
- 142. Jensen JH, Helpern JA, Ramani A, Lu H, Kaczynski K. Diffusional kurtosis imaging: the quantification of non‐gaussian water diffusion by means of magnetic resonance imaging. Magn Reson Med. 2005;53:1432‐1440. [DOI] [PubMed] [Google Scholar]
- 143. Chuhutin A, Hansen B, Jespersen SN. Precision and accuracy of diffusion kurtosis estimation and the influence of b‐value selection. NMR Biomed. 2017;30:e3777. doi: 10.1002/nbm.3777 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 144. Hansen B, Jespersen SN. Data for evaluation of fast kurtosis strategies, b‐value optimization and exploration of diffusion MRI contrast. Sci Data. 2016;3:160072. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 145. Hansen B, Lund TE, Sangill R, Jespersen SN. Experimentally and computationally fast method for estimation of a mean kurtosis. Magn Reson Med. 2013;69:1754‐1760. [DOI] [PubMed] [Google Scholar]
- 146. Hansen B, Lund TE, Sangill R, Stubbe E, Finsterbusch J, Jespersen SN. Experimental considerations for fast kurtosis imaging. Magn Reson Med. 2016;76:1455‐1468. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 147. Hansen B, Jespersen SN. Recent developments in fast kurtosis imaging. Front Phys. 2017;5:5. doi: 10.3389/fphy.2017.00040 29170738 [DOI] [Google Scholar]
- 148. Ambrosen KS, Eskildsen SF, Hinne M, et al. Validation of structural brain connectivity networks: the impact of scanning parameters. Neuroimage. 2020;204:116207. [DOI] [PubMed] [Google Scholar]
- 149. Schilling KG, Tax CMW, Rheault F, et al. Fiber tractography bundle segmentation depends on scanner effects, vendor effects, acquisition resolution, diffusion sampling scheme, diffusion sensitization, and bundle segmentation workflow. Neuroimage. 2021;242:118451. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 150. Neher PF, Descoteaux M, Houde JC, Stieltjes B, Maier‐Hein KH. Strengths and weaknesses of state of the art fiber tractography pipelines‐‐a comprehensive in‐vivo and phantom evaluation study using Tractometer. Med Image Anal. 2015;26:287‐305. [DOI] [PubMed] [Google Scholar]
- 151. Côté MA, Girard G, Boré A, Garyfallidis E, Houde JC, Descoteaux M. Tractometer: towards validation of tractography pipelines. Med Image Anal. 2013;17:844‐857. [DOI] [PubMed] [Google Scholar]
- 152. Shen K, Bezgin G, Schirner M, Ritter P, Everling S, McIntosh AR. A macaque connectome for large‐scale network simulations in TheVirtualBrain. Sci Data. 2019;6:123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 153. Daducci A, Canales‐Rodríguez EJ, Descoteaux M, et al. Quantitative comparison of reconstruction methods for intra‐voxel fiber recovery from diffusion MRI. IEEE Trans Med Imaging. 2014;33:384‐399. [DOI] [PubMed] [Google Scholar]
- 154. Girard G, Daducci A, Petit L, et al. AxTract: toward microstructure informed tractography. Hum Brain Mapp. 2017;38:5485‐5500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 155. Daducci A, Dal Palú A, Descoteaux M, Thiran JP. Microstructure informed Tractography: pitfalls and open challenges. Front Neurosci. 2016;10:247. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 156. Daducci A, Dal Palù A, Lemkaddem A, Thiran JP. COMMIT: convex optimization modeling for microstructure informed tractography. IEEE Trans Med Imaging. 2015;34:246‐257. [DOI] [PubMed] [Google Scholar]
- 157. Smith RE, Tournier JD, Calamante F, Connelly A. SIFT: spherical‐deconvolution informed filtering of tractograms. Neuroimage. 2013;67:298‐312. [DOI] [PubMed] [Google Scholar]
- 158. Smith RE, Tournier JD, Calamante F, Connelly A. SIFT2: enabling dense quantitative assessment of brain white matter connectivity using streamlines tractography. Neuroimage. 2015;119:338‐351. [DOI] [PubMed] [Google Scholar]
- 159. Pestilli F, Yeatman JD, Rokem A, Kay KN, Wandell BA. Evaluation and statistical inference for human connectomes. Nat Methods. 2014;11:1058‐1063. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 160. Wedeen VJ, Hagmann P, Tseng WYI, Reese TG, Weisskoff RM. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Magn Reson Med. 2005;54:1377‐1386. [DOI] [PubMed] [Google Scholar]
- 161. Leergaard TB, White NS, de Crespigny A, et al. Quantitative histological validation of diffusion MRI fiber orientation distributions in the rat brain. PLoS One. 2010;5:e8595. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162. Novikov DS, Fieremans E, Jespersen SN, Kiselev VG. Quantifying brain microstructure with diffusion MRI: theory and parameter estimation. NMR Biomed. 2019;32:e3998. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 163. Alexander DC, Dyrby TB, Nilsson M, Zhang H. Imaging brain microstructure with diffusion MRI: practicality and applications. NMR Biomed. 2019;32:e3841. [DOI] [PubMed] [Google Scholar]
- 164. Palombo M, Ianus A, Guerreri M, et al. SANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI. Neuroimage. 2020;215:116835. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165. Zhang J, Lemberskiy G, Moy L, Fieremans E, Novikov DS, Kim SG. Measurement of cellular‐interstitial water exchange time in tumors based on diffusion‐time‐dependent diffusional kurtosis imaging. NMR Biomed. 2021;34:e4496. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 166. Jelescu IO, de Skowronski A, Palombo M, Novikov DS. Neurite exchange imaging (NEXI): a minimal model of diffusion in gray matter with inter‐compartment water exchange. arXiv [physics.med‐ph]. August 2021. http://arxiv.org/abs/2108.06121 [DOI] [PMC free article] [PubMed]
- 167. Olesen JL, Østergaard L, Shemesh N, Jespersen SN. Diffusion time dependence, power‐law scaling, and exchange in gray matter. arXiv [physics.med‐ph]. August 2021. http://arxiv.org/abs/2108.09983 [DOI] [PMC free article] [PubMed]
- 168. Hill I, Palombo M, Santin M, et al. Machine learning based white matter models with permeability: an experimental study in cuprizone treated in‐vivo mouse model of axonal demyelination. Neuroimage. 2021;224:117425. [DOI] [PubMed] [Google Scholar]
- 169. Lasič S, Lundell H, Topgaard D, Dyrby TB. Effects of imaging gradients in sequences with varying longitudinal storage time‐case of diffusion exchange imaging. Magn Reson Med. 2018;79:2228‐2235. [DOI] [PubMed] [Google Scholar]
- 170. Cui Y, Dyvorne H, Besa C, Cooper N, Taouli B. IVIM diffusion‐weighted imaging of the liver at 3.0 T: comparison with 1.5 T. Eur J Radiol Open. 2015;2:123‐128. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 171. Zhou Z, Xu MJ, Gao B. Hepatocytes: a key cell type for innate immunity. Cell Mol Immunol. 2016;13:301‐315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 172. Behrens TEJ, Woolrich MW, Jenkinson M, et al. Characterization and propagation of uncertainty in diffusion‐weighted MR imaging. Magn Reson Med. 2003;50:1077‐1088. [DOI] [PubMed] [Google Scholar]
- 173. Vos SB, Tax CMW, Luijten PR, Ourselin S, Leemans A, Froeling M. The importance of correcting for signal drift in diffusion MRI. Magn Reson Med. 2017;77:285‐299. [DOI] [PubMed] [Google Scholar]
- 174. Malyarenko D, Galbán CJ, Londy FJ, et al. Multi‐system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice‐water phantom. J Magn Reson Imaging. 2013;37:1238‐1246. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 175. Holdsworth SJ, O'Halloran R, Setsompop K. The quest for high spatial resolution diffusion‐weighted imaging of the human brain in vivo. NMR Biomed. 2019;32:e4056. [DOI] [PubMed] [Google Scholar]
- 176. Figini M, Zucca I, Aquino D, et al. In vivo DTI tractography of the rat brain: an atlas of the main tracts in Paxinos space with histological comparison. Magn Reson Imaging. 2015;33:296‐303. [DOI] [PubMed] [Google Scholar]
- 177. Boretius S, Natt O, Watanabe T, et al. In vivo diffusion tensor mapping of the brain of squirrel monkey, rat, and mouse using single‐shot STEAM MRI. Magma. 2004;17:339‐347. [DOI] [PubMed] [Google Scholar]
- 178. Zhang J, Zhang X. Diffusion‐weighted imaging of the macaque brain using diffusion‐prepared turbo spin Echo in MRI. Appl Sci. 2021;11:12077. doi: 10.3390/app112412077 [DOI] [Google Scholar]
- 179. Ortiz‐Rios M, Balezeau F, Haag M, Schmid MC, Kaiser M. Dynamic reconfiguration of macaque brain networks during natural vision. Neuroimage. 2021;244:118615. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 180. Ventura‐Antunes L, Mota B, Herculano‐Houzel S. Different scaling of white matter volume, cortical connectivity, and gyrification across rodent and primate brains. Front Neuroanat. 2013;7:3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 181. Fieremans E, Lee HH. Physical and numerical phantoms for the validation of brain microstructural MRI: a cookbook. Neuroimage. 2018;182:39‐61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 182. Liao C, Bilgic B, Tian Q, et al. Distortion‐free, high‐isotropic‐resolution diffusion MRI with gSlider BUDA‐EPI and multicoil dynamic B shimming. Magn Reson Med. 2021;86:791‐803. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 183. Setsompop K, Fan Q, Stockmann J, et al. High‐resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: simultaneous multislice (gSlider‐SMS). Magn Reson Med. 2018;79:141‐151. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 184. Tian Q, Li Z, Fan Q, et al. SDnDTI: self‐supervised deep learning‐based denoising for diffusion tensor MRI. Neuroimage. 2022;253:119033. doi: 10.1016/j.neuroimage.2022.119033 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 185. Ning L, Setsompop K, Rathi Y. A Combined Compressed Sensing Super‐Resolution Diffusion and gSlider‐SMS Acquisition/Reconstruction for Rapid Sub‐Millimeter Whole‐Brain Diffusion Imaging . 2016.
- 186. Jiang X, Xu J, Gore JC. Mapping hepatocyte size in vivo using temporal diffusion spectroscopy MRI. Magn Reson Med. 2020;84:2671‐2683. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 187. Lamy J, Romain L, Ouhmich F. Dicomifier . 2021. doi: 10.5281/zenodo.4459178 [DOI]
- 188. Jeurissen B, Leemans A, Sijbers J. Automated correction of improperly rotated diffusion gradient orientations in diffusion weighted MRI. Med Image Anal. 2014;18:953‐962. [DOI] [PubMed] [Google Scholar]
- 189. Schilling KG, Yeh FC, Nath V, et al. A fiber coherence index for quality control of B‐table orientation in diffusion MRI scans. Magn Reson Imaging. 2019;58:82‐89. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 190. Veraart J, Novikov DS, Christiaens D, Ades‐Aron B, Sijbers J, Fieremans E. Denoising of diffusion MRI using random matrix theory. Neuroimage. 2016;142:394‐406. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 191. Kellner E, Dhital B, Kiselev VG, Reisert M. Gibbs‐ringing artifact removal based on local subvoxel‐shifts. Magn Reson Med. 2016;76:1574‐1581. [DOI] [PubMed] [Google Scholar]
- 192. Lee HH, Novikov DS, Fieremans E. Removal of partial Fourier‐induced Gibbs (RPG) ringing artifacts in MRI. Magn Reson Med. 2021;86:2733‐2750. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 193. Bautista T, O'Muircheartaigh J, Hajnal JV, Tournier JD. Removal of Gibbs ringing artefacts for 3D acquisitions using subvoxel shifts. Proceedings of the International Society for Magnetic Resonance in Medicine. Mira Smart Conference; 2021. https://archive.ismrm.org/2021/3535.html. [Google Scholar]
- 194. Andersson JLR, Sotiropoulos SN. An integrated approach to correction for off‐resonance effects and subject movement in diffusion MR imaging. Neuroimage. 2016;125:1063‐1078. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 195. Hansen CB, Nath V, Hainline AE, et al. Characterization and correlation of signal drift in diffusion weighted MRI. Magn Reson Imaging. 2019;57:133‐142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 196. Ades‐Aron B, Veraart J, Kochunov P, et al. Evaluation of the accuracy and precision of the diffusion parameter EStImation with Gibbs and NoisE removal pipeline. Neuroimage. 2018;183:532‐543. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 197. Cai LY, Yang Q, Hansen CB, et al. PreQual: an automated pipeline for integrated preprocessing and quality assurance of diffusion weighted MRI images. Magn Reson Med. 2021;86:456‐470. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 198. Tournier JD, Smith R, Raffelt D, et al. MRtrix3: a fast, flexible and open software framework for medical image processing and visualisation. Neuroimage. 2019;202:116137. [DOI] [PubMed] [Google Scholar]
- 199. Lohmeier J, Kaneko T, Hamm B, Makowski MR, Okano H. atlasBREX: automated template‐derived brain extraction in animal MRI. Sci Rep. 2019;9:12219. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 200. Liu Y, Unsal HS, Tao Y, Zhang N. Automatic brain extraction for rodent MRI images. Neuroinformatics. 2020;18:395‐406. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 201. Wang H, Yushkevich PA. Multi‐atlas segmentation with joint label fusion and corrective learning—an open source implementation. Front Neuroinform. 2013;7. doi: 10.3389/fninf.2013.00027 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 202. Chakravarty MM, Steadman P, van Eede MC, et al. Performing label‐fusion‐based segmentation using multiple automatically generated templates. Hum Brain Mapp. 2013;34:2635‐2654. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 203. Wang X, Li XH, Cho JW, et al. U‐net model for brain extraction: trained on humans for transfer to non‐human primates. Neuroimage. 2021;235:118001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 204. Hsu LM, Wang S, Walton L, Wang TWW, Lee SH, Shih YYI. 3D U‐net improves automatic brain extraction for isotropic rat brain magnetic resonance imaging data. Front Neurosci. 2021;15:801008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 205. Coupeau P, Fasquel JB, Mazerand E, Menei P, Montero‐Menei CN, Dinomais M. Patch‐based 3D U‐net and transfer learning for longitudinal piglet brain segmentation on MRI. Comput Methods Programs Biomed. 2022;214:106563. [DOI] [PubMed] [Google Scholar]
- 206. Manjón JV, Coupé P, Concha L, Buades A, Louis Collins D, Robles M. Diffusion weighted image Denoising using Overcomplete local PCA. PLoS One. 2013;8:e73021. doi: 10.1371/journal.pone.0073021 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 207. Henriques R, Ianuş A, Novello L, Jovicich J, Jespersen S, Shemesh N. Efficient PCA denoising of spatially correlated redundant MRI data. Imaging Neurosci. 2023;1:1‐26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 208. Moeller S, Pisharady PK, Ramanna S, et al. NOise reduction with DIstribution corrected (NORDIC) PCA in dMRI with complex‐valued parameter‐free locally low‐rank processing. Neuroimage. 2021;226:117539. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 209. Muckley MJ, Ades‐Aron B, Papaioannou A, et al. Training a neural network for Gibbs and noise removal in diffusion MRI. Magn Reson Med. 2021;85:413‐428. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 210. Veraart J, Fieremans E, Jelescu IO, Knoll F, Novikov DS. Gibbs ringing in diffusion MRI. Magn Reson Med. 2016;76:301‐314. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 211. Perrone D, Aelterman J, Pižurica A, Jeurissen B, Philips W, Leemans A. The effect of Gibbs ringing artifacts on measures derived from diffusion MRI. Neuroimage. 2015;120:441‐455. [DOI] [PubMed] [Google Scholar]
- 212. Smith SM, Jenkinson M, Woolrich MW, et al. Advances in functional and structural MR image analysis and implementation as FSL. Neuroimage. 2004;23:S208‐S219. [DOI] [PubMed] [Google Scholar]
- 213. Koay CG, Basser PJ. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson. 2006;179:317‐322. [DOI] [PubMed] [Google Scholar]
- 214. Ianuş A, Carvalho J, Fernandes FF, et al. Soma and Neurite density MRI (SANDI) of the in‐vivo mouse brain and comparison with the Allen brain atlas. Neuroimage. 2022;254:119135. [DOI] [PubMed] [Google Scholar]
- 215. Horsfield MA, Sala S, Neema M, et al. Rapid semi‐automatic segmentation of the spinal cord from magnetic resonance images: application in multiple sclerosis. Neuroimage. 2010;50:446‐455. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 216. De Leener B, Kadoury S, Cohen‐Adad J. Robust, accurate and fast automatic segmentation of the spinal cord. Neuroimage. 2014;98:528‐536. [DOI] [PubMed] [Google Scholar]
- 217. Gros C, De Leener B, Badji A, et al. Automatic segmentation of the spinal cord and intramedullary multiple sclerosis lesions with convolutional neural networks. Neuroimage. 2019;184:901‐915. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 218. De Leener B, Lévy S, Dupont SM, et al. SCT: spinal cord toolbox, an open‐source software for processing spinal cord MRI data. Neuroimage. 2017;145:24‐43. [DOI] [PubMed] [Google Scholar]
- 219. De Leener B, Taso M, Cohen‐Adad J, Callot V. Segmentation of the human spinal cord. Magma. 2016;29:125‐153. [DOI] [PubMed] [Google Scholar]
- 220. De Leener B, Mangeat G, Dupont S, et al. Topologically preserving straightening of spinal cord MRI. J Magn Reson Imaging. 2017;46:1209‐1219. doi: 10.1002/jmri.25622 [DOI] [PubMed] [Google Scholar]
- 221. Saliani A, Zaimi A, Nami H, Duval T, Stikov N, Cohen‐Adad J. Construction of a rat spinal cord atlas of axon morphometry. Neuroimage. 2019;202:116156. [DOI] [PubMed] [Google Scholar]
- 222. Cohen‐Adad J, Alonso‐Ortiz E, Abramovic M, et al. Open‐access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers. Sci Data. 2021;8:219. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 223. Nery F, Szczepankiewicz F, Kerkelä L, et al. In vivo demonstration of microscopic anisotropy in the human kidney using multidimensional diffusion MRI. Magn Reson Med. 2019;82:2160‐2168. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 224. Kjølby BF, Khan AR, Chuhutin A, et al. Fast diffusion kurtosis imaging of fibrotic mouse kidneys. NMR Biomed. 2016;29:1709‐1719. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 225. Zhang J, Zhang G, Morrison B, Mori S, Sheikh KA. Magnetic resonance imaging of mouse skeletal muscle to measure denervation atrophy. Exp Neurol. 2008;212:448‐457. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 226. Welsh CL, DiBella EVR, Hsu EW. Higher‐order motion‐compensation for in vivo cardiac diffusion tensor imaging in rats. IEEE Trans Med Imaging. 2015;34:1843‐1853. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 227. Reynaud O. Time‐dependent diffusion MRI in cancer: tissue modeling and applications. Front Phys. 2017;5. doi: 10.3389/fphy.2017.00058/full [DOI] [Google Scholar]
- 228. Lemberskiy G, Fieremans E, Veraart J, Deng FM, Rosenkrantz AB, Novikov DS. Characterization of prostate microstructure using water diffusion and NMR relaxation. Front Phys. 2018;6:6. doi: 10.3389/fphy.2018.00091 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 229. Immonen R, Smith G, Brady RD, et al. Harmonization of pipeline for preclinical multicenter MRI biomarker discovery in a rat model of post‐traumatic epileptogenesis. Epilepsy Res. 2019;150:46‐57. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 230. Jillings S, Morez J, Vidas‐Guscic N, et al. Multi‐tissue constrained spherical deconvolution in a murine brain. Proc Intl Soc Mag Reson Med. Vol 28. Mira Smart Conference; 2020:900. [Google Scholar]
- 231. Meola A, Comert A, Yeh FC, Stefaneanu L, Fernandez‐Miranda JC. The controversial existence of the human superior fronto‐occipital fasciculus: connectome‐based tractographic study with microdissection validation. Hum Brain Mapp. 2015;36:4964‐4971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 232. Thiebaut de Schotten M, Dell'Acqua F, Valabregue R, Catani M. Monkey to human comparative anatomy of the frontal lobe association tracts. Cortex. 2012;48:82‐96. [DOI] [PubMed] [Google Scholar]
- 233. Yeatman JD, Weiner KS, Pestilli F, Rokem A, Mezer A, Wandell BA. The vertical occipital fasciculus: a century of controversy resolved by in vivo measurements. Proc Natl Acad Sci U S A. 2014;111:E5214‐E5223. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 234. Warrington S, Bryant KL, Khrapitchev AA, et al. XTRACT ‐ standardised protocols for automated tractography in the human and macaque brain. Neuroimage. 2020;217:116923. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 235. Schilling KG, Gao Y, Stepniewska I, et al. The VALiDATe29 MRI based Multi‐Channel atlas of the squirrel monkey brain. Neuroinformatics. 2017;15:321‐331. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 236. Dodero L, Vascon S, Murino V, Bifone A, Gozzi A, Sona D. Automated multi‐subject fiber clustering of mouse brain using dominant sets. Front Neuroinform. 2014;8:87. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 237. Wasserthal J, Neher P, Maier‐Hein KH. TractSeg ‐ fast and accurate white matter tract segmentation. Neuroimage. 2018;183:239‐253. [DOI] [PubMed] [Google Scholar]
- 238. Wakana S, Caprihan A, Panzenboeck MM, et al. Reproducibility of quantitative tractography methods applied to cerebral white matter. Neuroimage. 2007;36:630‐644. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 239. Yeatman JD, Dougherty RF, Myall NJ, Wandell BA, Feldman HM. Tract profiles of white matter properties: automating fiber‐tract quantification. PLoS One. 2012;7:e49790. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 240. Smith SM, Jenkinson M, Johansen‐Berg H, et al. Tract‐based spatial statistics: voxelwise analysis of multi‐subject diffusion data. Neuroimage. 2006;31:1487‐1505. [DOI] [PubMed] [Google Scholar]
- 241. Yeh FC. Shape analysis of the human association pathways. Neuroimage. 2020;223:117329. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 242. Treuting PM, Dintzis SM, Montine KS. Comparative Anatomy and Histology: A Mouse, Rat, and Human Atlas. Academic Press; 2017. [Google Scholar]
- 243. Paxinos G, Halliday G, Watson C, Kassem MS. Atlas of the Developing Mouse Brain. Academic Press; 2020. [Google Scholar]
- 244. McLaren DG, Kosmatka KJ, Oakes TR, et al. A population‐average MRI‐based atlas collection of the rhesus macaque. Neuroimage. 2009;45:52‐59. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 245. Van Essen DC, Glasser MF, Dierker DL, Harwell J. Cortical parcellations of the macaque monkey analyzed on surface‐based atlases. Cereb Cortex. 2012;22:2227‐2240. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 246. Alexander DC, Barker GJ. Optimal imaging parameters for fiber‐orientation estimation in diffusion MRI. Neuroimage. 2005;27:357‐367. [DOI] [PubMed] [Google Scholar]
- 247. Jones R, Grisot G, Augustinack J, et al. Insight into the fundamental trade‐offs of diffusion MRI from polarization‐sensitive optical coherence tomography in ex vivo human brain. Neuroimage. 2020;214:116704. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 248. Schilling K, Gao Y, Janve V, Stepniewska I, Landman BA, Anderson AW. Can increased spatial resolution solve the crossing fiber problem for diffusion MRI? NMR Biomed. 2017;30:e3787. doi: 10.1002/nbm.3787 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 249. Maier‐Hein KH, Neher PF, Houde JC, et al. The challenge of mapping the human connectome based on diffusion tractography. Nat Commun. 2017;8:1349. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 250. Schilling KG, Tax CMW, Rheault F, et al. Prevalence of white matter pathways coming into a single white matter voxel orientation: the bottleneck issue in tractography. Hum Brain Mapp. 2021;43:1196‐1213. doi: 10.1002/hbm.25697 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 251. Reveley C, Seth AK, Pierpaoli C, et al. Superficial white matter fiber systems impede detection of long‐range cortical connections in diffusion MR tractography. Proc Natl Acad Sci U S A. 2015;112:E2820‐E2828. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 252. Aydogan DB, Jacobs R, Dulawa S, et al. When tractography meets tracer injections: a systematic study of trends and variation sources of diffusion‐based connectivity. Brain Struct Funct. 2018;223:2841‐2858. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 253. Bjerke IE, Øvsthus M, Andersson KA, et al. Navigating the murine brain: toward best practices for determining and documenting neuroanatomical locations in experimental studies. Front Neuroanat. 2018;12:82. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 254. Kleven H, Reiten I, Blixhavn CH, et al. A neuroscientist's guide to using murine brain atlases for efficient analysis and transparent reporting. Front Neuroinform. 2023;17:1154080. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 255. Wilkinson MD, Dumontier M, Aalbersberg IJJ, et al. The FAIR guiding principles for scientific data management and stewardship. Sci Data. 2016;3:160018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 256. Gorgolewski KJ, Auer T, Calhoun VD, et al. The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments. Sci Data. 2016;3:160044. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 257. Martone M, Goscinski W, Das S, et al. Call for community review of the brain imaging data structure – a standard for organizing and describing MRI data sets. F1000Res. 2018;7:1368. [Google Scholar]
- 258. Gholam J, Szczepankiewicz F, Tax CMW, et al. aDWI‐BIDS: an extension to the brain imaging data structure for advanced diffusion weighted imaging. arXiv [physics.med‐ph]. March 2021. http://arxiv.org/abs/2103.14485
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data S1: Supplementary Information.
Data Availability Statement
Data sharing is not applicable to this article as no new data were created or analyzed in this study.
