Skip to main content
Lippincott Open Access logoLink to Lippincott Open Access
. 2025 Mar 25;51(4):267–273. doi: 10.1097/j.jcrs.0000000000001600

Femtosecond laser-assisted customized corneal allogenic intrastromal ring segments in patients with keratoconus after intrastromal corneal ring segment explantation: prospective case series

Bianca N Susanna 1,✉, Adriana S Forseto 1, Aline S Moriyama 1, Marcony R Santhiago 1, Fernanda N Susanna 1,✉, Nicolas C Pereira 1
PMCID: PMC11980890  PMID: 39680687

Customized CAIRS in keratoconus patients with a history of ICRS extrusion leads to visual acuity improvement and keratometry reduction.

Abstract

Purpose:

To investigate the effectiveness and safety of customized femtosecond laser-assisted corneal allogenic intrastromal ring segment (CAIRS) implantation in keratoconus patients with a history of intrastromal corneal ring segment (ICRS) explantation.

Setting:

Sorocaba Eye Hospital (Hospital Oftalmológico de Sorocaba), Sorocaba, Brazil.

Design:

Prospective case series.

Methods:

8 keratoconus patients with stable disease and with a history of ICRS explantation at least 6 months before the the study were included. Patients were excluded if presenting any other ocular pathology. Customized CAIRS was produced and implanted using femtosecond laser LDV Z8. Patients were followed-up for 6 months.

Results:

The mean reduction of the maximum, mean, and steep central keratometry was 3.03 ± 1.35 diopters (D) (P = .01), 2.88 ± 2.51 D (P = .02), and 2.41 ± 2.72 D (P = .04), respectively. The mean spherical equivalent and refractive astigmatism reduced 6.28 ± 2.71 D (P = .01) and 1.62 ± 2.83 D (P = .16). All eyes, but 1 gained 2 or more lines of corrected distance visual acuity (CDVA). In addition, 5 patients achieved a CDVA of 20/40 or better. No intraoperative or postoperative complications were observed.

Conclusions:

Customized femtosecond laser-assisted CAIRS may be an effective and safe option for visual rehabilitation in keratoconus patients with previous ICRS explantation.


Intrastromal corneal ring segments (ICRSs) effectively treat keratoconus, reducing the corneal keratometry and irregularity, and enhancing visual acuity.1 However, some cases complicate with corneal infection, melting, neovascularization, perforation, and extrusion.2 A recent large multicenter case series showed that ICRS spontaneous extrusion is the second leading cause of explantation, with an overall rate of 1.58%.3 Previous reports found varying incidence from 2% to 30% of ICRS extrusion.4–6 ICRS complications are more common in atopic patients, in thin and extremely ectatic corneas, eccentric keratoconus, or with simultaneous corneal crosslinking (CXL) surgery.7

There is no consensus regarding the best visual rehabilitation practice after ICRS removal. The surgeon might wait for corneal stabilization to implant a new ICRS or do it simultaneously with explantation.8,9 Eventually, the scarring after ICRS extrusion leads to corneal thinning, needing to step up treatment to a penetrating/lamellar keratoplasty.10 Previous studies investigated the effect of simultaneously replacing extruded ICRS for corneal allogenic intrastromal ring segments (CAIRSs).11,12 They demonstrated that this procedure could restore premelting keratometry values and visual acuity.11,12 Once CAIRS is an allogenic tissue, it could present a lower risk of extrusion and other complications than the rigid synthetic segment.13

Studies with CAIRS as a primary treatment for keratoconus also demonstrated good refractive and tomographic results, with significant visual acuity improvement.13–15 However, there is currently no study investigating the role of CAIRS as a treatment for patients with keratoconus after ICRS extrusion and corneal healing. The cornea may take up to 3 months to stabilize after the surgical intervention, and planning a late and customized CAIRS implantation may yield more accurate outcomes.16

In this study, we aimed to investigate the effect of customized femtosecond laser-assisted CAIRS in keratoconus patients with at least 6 months of history of ICRS explantation. Here, we briefly describe our surgical technique.

METHODS

This prospective case series was conducted at the Sorocaba Eye Hospital (Hospital Oftalmológico de Sorocaba), Sorocaba, Brazil, from November 2022 through May 2023. We obtained institutional review board approval (protocol number 64752422.0.0000.0088) and informed consent for all patients and conducted the study per the tenets of the Declaration of Helsinki. Inclusion criteria were stable keratoconus patients with ICRS explantation at least 6 months before inclusion. The exclusion criteria were progressive keratoconus, other factors leading to impaired visual acuity, any ocular surgeries other than corneal crosslinking, and ICRS implantation/explantation. The minimum follow-up period was 6 months. We evaluated the patients preoperatively, then 1 day, 7 days, 3 months, and 6 months postoperatively. In each visit, we assessed corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA), spherical and cylindric refraction, corneal tomographic and aberrometric data (Galilei, Ziemer Ophthalmic Systems AG), and corneal and segment thickness and depth on anterior segment optical coherence tomography (AS-OCT, Solix, Optovue, Inc.).

Surgical Technique

We selected nonedematous donor cornea and mounted on an artificial anterior chamber. These corneas were stored in Optisol-GS (Bausch & Lomb, Inc.) or Eusol C (Alchimia srl) preservation medium and were considered suitable only for anterior lamellar keratoplasty because of low donor endothelial cell density (≤2000 cells/mm2). The donor epithelium was removed using 70% alcohol for 20 seconds and a wet micro sponge (Merocel, Beaver-Visitec International), followed by copious balanced saline solution irrigation of the cornea surface.

We produced the segments with LDV 8 femtosecond laser assistance (Ziemer Ophthalmic Systems AG). The thickness of the segment was 100% of the host's minimum stromal thickness at the implantation zone. We assessed the host stromal thickness preoperatively using AS-OCT with the “measurement tool,” which allowed us to exclude the epithelial thickness and measure the stromal thickness at the exact desired corneal diameter. The number of arcs and length were defined based on each case's refraction, visual acuity, topographic astigmatism, keratometry, asphericity, posterior elevation, and keratoconus morphological phenotype (Alfonso-Ferrara morphological classification).17 This will be further addressed in the “Discussion section.” The width was settled at 600 μm.

After proper asepsis and anesthesia, we prepared the tunnel with femtosecond assistance. The main incision was on the steep axis, and a second incision was at the end of the tunnel. The inner/outer diameters were 5.00/7.04 mm. The tunnel depth was 50% of the minimum stromal thickness at the implantation zone, which was based on the previous AS-OCT and rechecked with intraoperatory pachymetry. If the depth was coincident with the ICRS tunnel scar, then a new tunnel depth was made away from it. We inserted the segments manually using a Sinskey hook.

Statistical Analysis

We did statistical analyses with Stata, v. 16 (Statacorp LLC) and considered P values less than 0.05 statistically significant. We studied patient characteristics using descriptive statistics. Although the Shapiro-Wilk normality test pointed a normal distribution for our sample, we considered all data nonparametrical because of the small sample size. Clinical outcomes were compared before and after the procedure using the Wilcoxon signed-rank test.

RESULTS

In this study, we describe 8 cases of customized CAIRS in keratoconus patients with previous ICRS explantation. The mean age was 30.5 ± 6.3 years old (range, 24 to 42 years), and 6 patients (75%) were female. Preoperative thinnest tomographic pachymetry was 434 ± 63 μm (range, 286 to 485 μm). The mean time from ICRS extrusion to CAIRS implantation was 12 ± 2.8 months (range, 7 to 16 months). Two patients (cases 2 and 8) remained with 1 ICRS nasally. Details of each CAIRS are in Table 1. There were no intraoperative or postoperative complications.

Table 1.

CAIRS configurations and implantation characteristics

Characteristics Case 1 Case 2 Case 3 Case 4 Case 5 Case 6 Case 7 Case 8
Temporal CAIRS
Arc (degrees)/thickness (μm)
160/500 160/400 160/400 160/400 160/A300-400 160/500 160/400 160/A375-475
Nasal CAIRS
Arc (degrees)/thickness (μm)
140/400 x x 160/350 90/300 160/400 X NA
Tunnel depth (μm) 400 350 293 258 215 272 192 400
Tunnel incision (degrees) 110 75 40 80 30 115 15 90

A = asymmetric; CAIRS = corneal allogenic intrastromal ring segments; N = nasal; NA = not applicable (presence of ICRS); T = temporal; x = none

The preoperative and postoperative data of each patient's last follow-up are given in Table 2. The mean follow-up was 7.9 ± 2.6 months (range, 6 to 12). Table 3 presents preoperative and postoperative clinical results. The mean reduction of the maximum, mean, and steep central keratometry was 3.03 ± 1.35 diopters (D) (P = .01), 2.88 ± 2.51 D (P = .02), and 2.41 ± 2.72 D (P = .04), respectively. The mean spherical equivalent (SE) and refractive astigmatism reduced 6.28 ± 2.71 D (P = .01) and 1.62 ± 2.83 D (P = .16), respectively. There was no significant change in topographical/refractive astigmatism, in asphericity, total coma, and 5 mm total corneal aberration.

Table 2.

Preoperative and postoperative clinical characteristics of patients submitted to CAIRS implantation

Characteristics Case 1 (33 yo) Case 2 (42 yo) Case 3 (28 yo) Case 4 (33 yo) Case 5 (25 yo) Case 6 (34 yo) Case 7 (24 yo) Case 8 (24 yo)
Pre Post Pre Post Pre Post Pre Post Pre Post Pre Post Pre Post Pre Post
Spherical equivalent (D) −7.75 −3.00 −6.00 −3.75 −10.50 0 −9.75 −2.00 −10.00 −2.75 −11.00 −7.75 −11.00 −3.00 −9.25 −0.75
Spherical refraction (D) −5.75 −2.00 −3.50 −2.75 −8.00 +1.25 −6.75 −1.25 −8.00 −2.00 −11.0 −5.00 −8.00 −2.00 −8.00 +0.50
Refractive astigmatism (D) −4.00 −2.00 −4.75 −2.00 −5.00 −2.50 −6.00 −1.50 −4.00 −2.25 0 −3.50 −6.00 −2.00 −2.50 −2.50
CDVA (Snellen) 20/100 20/40 20/70 20/40 20/60 20/40 20/80 20/60 20/40 20/40 20/150 20/80 20/150 20/50 20/100 20/30
UDVA (Snellen) CF 2 m 20/100 20/200 20/70 CF 3 m 20/50 CF 1 m 20/150 20/200 20/60 CF 1 m CF 1 m CF 50 cm 20/100 CF 2 m 20/40
SimK (D) 50.29 45.53 51.50 50.83 54.52 53.12 47.20 45.99 52.54 46.34 47.55 46.06 53.40 47.89 51.01 47.19
K2 (D) 52.38 47.21 53.82 53.10 57.01 59.12 50.95 49.73 54.16 47.94 47.99 46.49 56.00 53.85 52.84 48.45
K1 (D) 48.19 43.86 49.18 48.56 54.52 51.13 43.45 42.25 50.93 44.74 47.12 45.63 50.80 41.92 49.17 45.92
Kmax (D) 54.67 50.74 58.79 56.92 65.92 64.01 55.97 51.75 56.38 51.76 51.07 49.26 57.56 56.06 57.54 53.22
Topographic astigmatism (D) 4.19 3.35 4.64 4.54 4.98 7.99 7.50 7.48 3.23 3.20 0.87 1.00 5.20 11.93 3.67 2.53
Asphericity 1.13 1.46 1.57 1.51 0.71 2.29 1.40 1.53 1.53 1.20 1.48 1.47 1.08 1.43 2.16 1.91
5 mm TCA (μm) 3.39 2.62 4.92 3.33 7.69 8.83 5.66 5.66 3.03 2.34 2.12 1.26 4.40 6.48 3.75 2.22
Total coma (μm) 1.52 1.66 2.53 2.12 4.01 3.64 2.82 2.49 1.13 1.17 1.52 0.74 1.17 1.78 2.90 1.94

CAIRS = corneal allogenic intrastromal ring segments; CF = counting finger; K1 = flat central keratometry; K2 = steep central keratometry; Kmax = maximum keratometry; SimK = simulated mean keratometry; TCA = total corneal aberration; yo = years old

Table 3.

Preoperative and postoperative visual, refractive, topographic, and aberrometric results

Variables (n = 8) Preop
Mean (SD)
Postop
Mean (SD)
Difference
Mean (SD)
P value
Kmax (D) 57.24 (4.22) 54.21 (4.72) −3.03 (1.35) .01*
SimK (D) 51.00 (2.61) 48.12 (3.29) −2.88 (2.51) .02*
K1 (D) 48.86 (2.70) 45.50 (3.11) −3.36 (2.95) .01*
K2 (D) 53.14 (2.84) 50.74 (4.31) −2.41 (2.72) .04*
Topographic astigmatism (D) 4.28 (1.89) 5.23 (3.63) +0.95 (2.65) .34
Total coma (μm) 2.2 (1.03) 1.94 (0.87) −0.26 (0.51) .19
5 mm TCA (μm) 4.21 (1.72) 4.09 (2.62) −0.12 (1.19) .78
Asphericity 1.49 (0.34) 1.68 (0.54) +0.19 (0.48) .30
Spherical equivalent (D) −9.41 (1.74) −3.12 (2.39) −6.28 (2.71) .01*
Spherical refraction (D) −7.37 (2.16) −1.97 (2.17) −5.41 (2.75) <.01*
Cylinder refraction (D) −4.03 (1.99) −2.41 (0.90) −1.62 (2.83) .16
UDVA (decimals) 0.03 (0.04) 0.26 (0.15) +0.22 (0.15) <.01*
CDVA (decimals) 0.26 (0.12) 0.46 (0.13) +0.19 (0.14) <.01*

(+) = increase; (−) = reduction; K1 = flattest central keratometry; K2 = steepest central keratometry; Kmax = maximum keratometry; SimK = simulated mean keratometry; TCA = total corneal aberration

*

Statistically significant

There was a significant improvement in both CDVA and UDVA by 2.75 ± 1.7 lines (range, 0 to 5) and 10 ± 5.0 lines (range, 0 to 15), respectively (Figure 1). All eyes, but 1, gained 2 or more lines of CDVA. Five patients achieved a CDVA of 20/40 or better.

Figure 1.

Figure 1.

Preoperative and postoperative change in CDVA and UDVA. The numbers on the top of the columns represent the total number of eyes with the respective change of Snellen lines of visual acuity.

Figure 2 shows the topographical comparison map, AS-OCT, and biomicroscopy photograph of case 8.

Figure 2.

Figure 2.

Case 8. A: 6-month postoperative anterior axial curvature map. B: Preoperative anterior axial curvature map. C: Differential anterior axial curvature map. D: 6-month follow-up biomicroscopy photograph. Temporal CAIRS (red arrow); nasal ICRS (yellow arrow). E: AS-OCT line. Temporal CAIRS (red arrow); nasal ICRS (yellow arrow). CAIRS = corneal allogenic intrastromal ring segments

DISCUSSION

This case series demonstrates that implanting customized CAIRS in keratoconus patients with a history of ICRS explantation may yield good functional outcomes with safety. This is an encouraging result because there has yet to be a consensus on the best approach after ICRS extrusion. These patients might have a higher risk for new extrusion due to thin or steep cornea or personal risk factors such as eye rubbing. Some authors advocate reimplanting ring segments simultaneously, while others prefer waiting at least 3 months for corneal stabilization. In some cases, the best option is corneal transplantation because of the low chances of satisfactory visual outcome with ICRS or the risk for new extrusion.18

With the advent of CAIRS, the allogenic tissue could be safer than the polymethacrylate of ICRS, with more long-term biocompatibility, permeability to oxygen, less extrusion, and stromal melting. None of the few studies published since the first article reported such complications. However, the longest follow-up was 18 months.13 Kozhaya et al. investigated eyes with anterior stromal necrosis secondary to ICRS and compared the effect of implanting CAIRS at the moment of ICRS explantation with explantation alone.19 They found increased minimal stromal thickness, and stabilization of both keratometry parameters and visual acuity in the group of simultaneous CAIRS implantation. They concluded that early exchange of ICRS for CAIRS in stromal necrosis confers better visual and topographic results than explantation alone.

In our study, we waited at least 7 months after ICRS explantation before proceeding with CAIRS. With this approach, we attempt the best surgical planning, once refractive stabilization may take at least 3 months in the corneal healing process.16

We customized the CAIRS for each case, varying length, thickness, and optic zone. We considered the Keraring nomogram, which includes keratoconus topography morphology and keratometry data, and we also looked at the posterior curvature, coma, asphericity, corneal pachymetry, and manifest refraction. Hence, we defined the length of each segment with the same rationale of ICRS; if we desired more applanation than regularization, we had segments with longer arches. If astigmatism or irregularity was predominant, we produced shorter arc segments. We produced segments with asymmetric thickness throughout their extent in cases with asymmetry in 2 meridians of the same axis (eg, with inferior curvature at least 5 D steeper than the superior curvature in the vertical meridian). This can be seen in cases 5 and 8 (Table 1 and Figure 2). CAIRS production using FSL offers the advantages of precision and reproducibility.20 However, total customization of CAIRS, including variable thickness within the segment, can also be achieved manually. This method has been previously demonstrated by Jacob et al.14

The decision on the segment thickness was based on Soosan Jacob's first article, describing a donor corneal full-thickness segment.13 We understand that, similar to ICRS, the thicker the segment, the greater the effect. However, we empirically rationalized that it would be safer to restrict the thickness to the host's thinnest stromal thickness at the implantation optical zone. Introducing thick tissue into a thin cornea with stromal scarring can increase the risk for intraoperative complications, such as surface breakthrough with instruments. Therefore, surgical maneuvers should be performed gently, and accessing tunnel depth with intraoperative OCT provides additional safety.

In this study, all but 1 patient (case 6) considerably improved the UDVA. Even maintaining the UDVA (counting finger at 1 m), her CDVA improved by 2 lines. This patient had one of the mildest applanation effects on simulated keratometry. It is challenging to determine an association effect between the parameters because of our small sample size. Previous studies suggested that the thicker the segment and the more superficial its implantation, the greater its effect.15 In case 6, the nasal 400 μm thickness segment was implanted at 272 μm depth, more superficial compared with other cases with better results. However, at the 6-month follow-up, the segment thickness measured with AS-OCT was only 281 μm, 30% thinner than the initial setting. In this study, we cannot conclude if there is a real thinning of the CAIRS due to its compression or rather a dehydration after being cut from an edematous cornea. The biomechanical behavior of the host cornea could also play a role, leading to less response of the donor cornea. In this matter, case 6 had previous CXL surgery and had older age, both affect corneal biomechanics and could reduce the CAIRS flattening effect.21–23

In our sample, CAIRS led to a significant improvement in the CDVA. All eyes, but 1 (case 5), gained 2 or more lines of CDVA. Even maintaining her preoperative CDVA (20/40), case 5 had a great improvement of the UDVA from 20/200 to 20/60, and reduction in spherical and cylindric refraction (Table 2).

At the last follow-up, 5 patients achieved CDVA of 20/40 or better, a functional visual acuity. The refractive SE mean reduction was 6.28 D (P < .01), and the spherical refraction reduced 5.41 D (P < .01). Interestingly, we noticed a discrepancy between topographic and refractive astigmatism changes. Although not statistically significant, mean refractive astigmatism reduced by 1.62 D (P = .15), while topographic astigmatism increased by 0.95 D (P = .34). Indeed, there was a more important change in the flattest K reading than in the steepest, explaining the astigmatism increase. In case 3, refractive astigmatism decreased from −6.00 to −2.50 D, while the topographic astigmatism increased by 2.99 D, leading to a topographic astigmatism of 7.99 D (despite UDVA of 20/50 Snellen chart). This discrepancy between topographic and refractive astigmatism may be related to an anterior surface irregularity.

The main limitation of our study is that we have a small sample with relatively short follow-up. However, we aimed to report early findings that can encourage further investigations. In addition, the literature indicates that ICRS extrusion typically occurs around 6 months after implantation.7 In our study, the follow-up period ranged from 6 to 12 months, and we did not observe any initial signs of the extrusion process, such as segment migration or overlying stromal thinning, in any of the cases.

This study is a consecutive prospective case series evaluating the short-term results of customized CAIRS in keratoconus patients with a history of ICRS explantation. To the author's knowledge, we are the first to report these findings. We demonstrate that CAIRS may yield good functional results with safety in a group of keratoconus patients with more limited treatment options. We encourage further investigation with bigger sample and longer follow-up time.

WHAT WAS KNOWN

  • Manually customized corneal allogenic intrastromal ring segments (CAIRSs) have shown efficacy in reducing keratometry and improving visual acuity as a primary treatment for keratoconus.

  • CAIRS implantation during ICRS explantation can prevent corneal melting and deterioration of visual acuity.

  • There remains a lack of consensus on the rehabilitation strategy for patients with keratoconus long-term after ICRS extrusion.

WHAT THIS PAPER ADDS

  • CAIRS can be entirely customized with femtosecond laser assistance.

  • CAIRS reduces refractive and keratometry measures and improves visual acuity in keratoconus patients with a history of ICRS extrusion.

Acknowledgments

Fabian Müller, from Ziemer Ophthalmic Systems AG, Port, Switzerland; Created the Software for the Laser system which enables personalized FEMTO CAIRS to be planned and cut. Guilherme Guerra and Ricardo Florez, from Adapt Produtos Oftalmologicos Ltda, São Paulo, Brazil; for managing technical issues related to the Ziemer Z8 femtossecond laser.

Footnotes

Disclosures: None of the other authors have any financial or proprietary interest in any material or method mentioned.

graphic file with name jcrs-51-267-g003.jpg

First author:

Bianca N. Susanna, MD

Department of Ophthalmology, Sorocaba Eye Hospital, Sorocaba Eye Bank, Sorocaba, University of São Paulo, São Paulo, Brazil

Contributor Information

Adriana S. Forseto, Email: forseto@uol.com.br.

Aline S. Moriyama, Email: aline_moriyama@yahoo.com.

Marcony R. Santhiago, Email: marconysanthiago@hotmail.com.

Fernanda N. Susanna, Email: fernanda.susanna@fm.usp.br.

Nicolas C. Pereira, Email: nicolascepe@gmail.com.

REFERENCES

  • 1.Giacomin NT, Mello GR, Medeiros CS, Kiliç A, Serpe CC, Almeida HG, Kara-Junior N, Santhiago MR. Intracorneal ring segments implantation for corneal ectasia. J Refract Surg. 2016;32(12):829–839. doi: 10.3928/1081597X-20160822-01 [DOI] [PubMed] [Google Scholar]
  • 2.Coskunseven E, Kymionis GD, Tsiklis NS, Atun S, Arslan E, Siganos CS, Jankov M, Pallikaris IG. Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus. Acta Ophthalmol. 2011;89(1):54–57. doi: 10.1111/J.1755-3768.2009.01605.X [DOI] [PubMed] [Google Scholar]
  • 3.D’Oria F, Abdelghany AA, Ledo N, Barraquer RI, Alio JL. Incidence and reasons for intrastromal corneal ring segment explantation. Am J Ophthalmol. 2021;222:351–358. doi: 10.1016/J.AJO.2020.09.041 [DOI] [PubMed] [Google Scholar]
  • 4.Kanellopoulos AJ, Pe LH, Perry HD, Donnenfeld ED. Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus: efficacy and complications. Cornea. 2006;25(1):29–33. doi: 10.1097/01.ICO.0000167883.63266.60 [DOI] [PubMed] [Google Scholar]
  • 5.Kwitko S, Severo NS. Ferrara intracorneal ring segments for keratoconus. J Cataract Refract Surg. 2004;30(4):812–820. doi: 10.1016/j.jcrs.2003.12.005 [DOI] [PubMed] [Google Scholar]
  • 6.Mounir A, Radwan G, Farouk MM, Mostafa EM. Femtosecond-assisted intracorneal ring segment complications in keratoconus: from novelty to expertise. Clin Ophthalmol. 2018;12:957–964. doi: 10.2147/OPTH.S166538 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Mounir A, Farouk MM, Abdellah MM, Mohamed Mostafa E. Extrusion of femtosecond laser-implanted intrastromal corneal ring segments in keratoconic eyes: prevalence, risk factors, and clinical outcomes. J Ophthalmol. 2020;2020:8704219. doi: 10.1155/2020/8704219 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Bali SJ, Chan C, Hodge C, Sutton G. Intracorneal ring segment reimplantation in keratectasia. Asia Pac J Ophthalmol. 2012;1(6):327–330. doi: 10.1097/APO.0B013E31826E1D30 [DOI] [PubMed] [Google Scholar]
  • 9.Alió JL, Piñero DP, Söğütlü E, Kubaloglu A. Implantation of new intracorneal ring segments after segment explantation for unsuccessful outcomes in eyes with keratoconus. J Cataract Refract Surg. 2010;36(8):1303–1310. doi: 10.1016/J.JCRS.2010.02.017 [DOI] [PubMed] [Google Scholar]
  • 10.Al-Habboubi HF, Martinez-Osorio H, Y Maktabi AM, Badawi AH, Aldosari FN, Khandekar R, Al-Swailem SA. Long-term outcomes and causes of intrastromal corneal ring segment explantation in a tertiary eye hospital. Saudi J Ophthalmol. 2022;36(1):64–69. doi: 10.4103/SJOPT.SJOPT_70_22 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Daoud RC, Sammouh FK, Baban TA, Warrak JE, Warrak EL. Allogenic corneal tissue transplantation in substitution for extruded intracorneal rings: a case series. J Fr Ophtalmol. 2019;42(10):1090–1093. doi: 10.1016/J.JFO.2019.05.028 [DOI] [PubMed] [Google Scholar]
  • 12.Jarade E, Issa M, Chanbour W, Warhekar P. Biologic stromal ring to manage stromal melting after intrastromal corneal ring segment implantation. J Cataract Refract Surg. 2019;45(9):1222–1225. doi: 10.1016/J.JCRS.2019.05.022 [DOI] [PubMed] [Google Scholar]
  • 13.Jacob S, Patel SR, Agarwal A, Ramalingam A, Saijimol AI, Raj JM. Corneal allogenic intrastromal ring segments (CAIRS) combined with corneal cross-linking for keratoconus. J Refract Surg. 2018;34(5):296–303. doi: 10.3928/1081597X-20180223-01 [DOI] [PubMed] [Google Scholar]
  • 14.Jacob S, Agarwal A, Awwad ST, Mazzotta C, Parashar P, Jambulingam S. Customized corneal allogenic intrastromal ring segments (CAIRS) for keratoconus with decentered asymmetric cone. Indian J Ophthalmol. 2023;71(12):3723–3729. doi: 10.4103/IJO.IJO_1988_23 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Bteich Y, Assaf JF, Mrad AA, Jacob S, Hafezi F, Awwad ST. Corneal allogenic intrastromal ring segments (CAIRS) for corneal ectasia: a comprehensive segmental tomography evaluation. J Refract Surg. 2023;39(11):767–776. doi: 10.3928/1081597X-20231011-01 [DOI] [PubMed] [Google Scholar]
  • 16.Asbell PA, Uçakhan ÖÖ, Abbott RL, Assil KA, Burris TE, Durrie DS, Lindstrom RL, Schanzlin DJ, Verity SM, Waring GO. Intrastomal corneal ring segments: reversibility of refractive effect. J Refract Surg. 2001;17(1):25–31. doi: 10.3928/1081-597X-20010101-03 [DOI] [PubMed] [Google Scholar]
  • 17.Barbara R, Barbara A, Castillo JH, Hanna R, Berkowitz E, Tiosano B. Keratoconus Expert Meeting, London, 2014. Int J Keratoconus Ectatic Corneal Dis. 2014;3(3):141–158. doi: 10.5005/IJKECD-3-3-141 [DOI] [Google Scholar]
  • 18.Chhadva P, Yesilirmak N, Cabot F, Yoo SH. Intrastromal corneal ring segment explantation in patients with keratoconus: causes, technique, and outcomes. J Refract Surg. 2015;31(6):392–397. doi: 10.3928/1081597X-20150521-05 [DOI] [PubMed] [Google Scholar]
  • 19.Kozhaya K, Mehanna CJ, Jacob S, Saad A, Jabbur NS, Awwad ST. Management of anterior stromal necrosis after polymethylmethacrylate ICRS: explantation versus exchange with corneal allogenic intrastromal ring segments. J Refract Surg. 2022;38(4):256–263. doi: 10.3928/1081597X-20220223-01 [DOI] [PubMed] [Google Scholar]
  • 20.Mechleb N, Flamant R, Panthier C, Ghazal W, Dubois M, Gatinel D, Saad A. Technique of corneal allogenic ring segment preparation using femtosecond laser: preclinical study on human corneal grafts. J Cataract Refract Surg. 2024;50(5):518–522. doi: 10.1097/J.JCRS.0000000000001399 [DOI] [PubMed] [Google Scholar]
  • 21.Coskunseven E, Jankov MR, Hafezi F, Atun S, Arslan E, Kymionis GD. Effect of treatment sequence in combined intrastromal corneal ringsand corneal collagen crosslinking for keratoconus. J Cataract Refract Surg. 2009;35(12):2084–2091. doi: 10.1016/J.JCRS.2009.07.008 [DOI] [PubMed] [Google Scholar]
  • 22.El-Khoury S, Abdelmassih Y, Amro M, Dirani A, Cherfan C, Jarade E. The effect of age on corneal topographic indices, keratometry and visual acuity after combined intrastromal corneal ring segment (ICRS) implantation and corneal crosslinking. Med Hypothesis Discov Innov Ophthalmol. 2020;9(2):135–142 [PMC free article] [PubMed] [Google Scholar]
  • 23.Salouti R, Khalili MR, Zamani M, Ghoreyshi M, Nowroozzadeh MH. Assessment of the changes in corneal biomechanical properties after collagen cross-linking in patients with keratoconus. J Curr Ophthalmol. 2019;31(3):262–267. doi: 10.1016/J.JOCO.2019.02.002 [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Cataract and Refractive Surgery are provided here courtesy of Wolters Kluwer Health

RESOURCES