Table 7.
Predictive value of EEG combined with NSE for brain function prognosis in children with febrile seizures
Area under the curve (AUC) | Confidence interval (CI) | Cut-off | Sensitivity | Specificity | Youden index | |
---|---|---|---|---|---|---|
EEG | 0.745 | 0.644-0.847 | 0.5 | 82.35% | 66.67% | 49.02% |
NSE | 0.878 | 0.809-0.947 | 12.695 | 73.53% | 85.19% | 58.72% |
EEG+NSE | 0.951 | 0.901-1.000 | 0.60881 | 100.00% | 81.48% | 81.48% |
Note: EEG, electroencephalogram; NSE, neuron-specific enolase.