Skip to main content
. Author manuscript; available in PMC: 2026 Apr 1.
Published in final edited form as: Clin Biomech (Bristol). 2025 Mar 20;124:106493. doi: 10.1016/j.clinbiomech.2025.106493

Table 2.

Correlation between IOP and WS, elasticity, viscosity of optic nerve and optic nerve head as well as with age for both NTG vs. control.

Location Parameters NTG Control
r p-value Linear regression r p-value
Optic Nerve WS-100Hz −0.52 0.009 3.50–0.0845*IOP; R2 = 0.27 0.30 0.159
WS-150Hz −0.47 0.019 3.47 −0.0836*IOP; R2 = 0.23 0.38 0.063
WS-200Hz −0.50 0.012 3.61 −0.081*IOP; R2 = 0.25 0.24 0.268
Elasticity −0.59 0.002 13.2 −0.503*IOP; R2 = 0.35 0.30 0.412
Viscosity 0.11 0.600 x 0.11 0.621
Optic Nerve Head WS-100Hz −0.38 0.068 x 0.26 0.213
WS-150Hz −0.30 0.147 x 0.32 0.125
WS-200Hz −0.36 0.087 x 0.38 0.068
Elasticity 0.15 0.540 x 0.30 0.157
Viscosity −0.19 0.365 x 0.29 0.171