Skip to main content
European Journal of Medical Research logoLink to European Journal of Medical Research
. 2025 Apr 15;30:290. doi: 10.1186/s40001-025-02488-5

Clinical effectiveness of Zirconia versus titanium dental implants in anterior region: an overview of systematic reviews

Saeed M Alqahtani 1, Saurabh Chaturvedi 1,2,, Mohammed Alkhurays 3, Mohammed Abdullah Al Mansoori 4, Vini Mehta 5, Mudita Chaturvedi 5
PMCID: PMC12001583  PMID: 40235013

Abstract

Background

Nowadays dental implants are commonly used and to fulfil esthetic demands, zirconia has been suggested as an implant material as an alternative to titanium. Many researchers and systematic reviews are documented on it, but the results have been often inconsistent. This overview of systematic reviews aimed to report on the factors that influence the clinical effectiveness of zirconia (Zi) versus titanium (Ti) dental implants in anterior region.

Methods

This overview of systematic reviews (Registration Number CRD42023396206) is in accordance with the Transparent Reporting of Systematic Reviews and Meta-analyses. PubMed, Cochrane, Scopus, Embase and Google Scholar databases were sourced for systematic review and meta-analyses. Joanna Briggs Institute (JBI) criteria and Measurement Tool to Assess systematic Reviews” (AMSTAR-2), evaluated the quality. The PICO-focused question of this overview of systematic reviews was “What are the various factors influencing the clinical performance of Zi versus Ti implants in the anterior area?”, Evaluations were assessed by two assessors. In case there was any uncertainty or dispute among the reviewers, the work was included for further screening. Using Cohen's kappa, the inter-reviewer reliability was evaluated.

Results

Six reviews were chosen from 57 suitable reviews for this data analysis. Although the survival and effectiveness rates backed titanium implants, there was no conclusive proof of marginal bone loss. Zirconium implants performed better in terms of aesthetics.

Conclusion

Clinical performance of zirconia could be considered at par with titanium implants in the anterior area. Titanium has exhibited greater mechanical performance but no significant difference between two recorded. In future, studies with improved design are needed to identify biological and technical factors that affect implant’s efficacy.

Novelty and relevance

This is the first overview of systematic reviews focusing specifically on the anterior region, evaluates both aesthetic and biomechanical performance of Zi and Ti Implants, offers detailed insight into material-specific advantages and limitations. In the present clinical scenario it addresses a critical gap by comparing the performance of Zi and Ti implants and evaluates patient-centred priorities, particularly in the highly visible anterior region.

Supplementary Information

The online version contains supplementary material available at 10.1186/s40001-025-02488-5.

Keywords: Aesthetics, Bone loss, Survival rate, Success rate, Systematic reviews

Introduction

A frequent and reliable method of restoring missing teeth is dental implants [1]. Studies have shown that they had higher success rate (ScR), with long-term ScR ranging from 90 to 98% over 10 years of use [2, 3]. ScR can vary depending on various factors, like patient bone quality, the placement of the implant, and the patient's overall oral hygiene [4]. Dental implants often use zirconium (Zi) and titanium (Ti). Both demonstrate good clinical performance, but there are some differences in their properties and how they perform in the oral environment [5].

Ti dental implants have been used for over 50 years and have a proven track record of success. They have a high ScR and are considered to be unsurpassed in implant materials used in dentistry [6]. Ti is biocompatible and highly resistant to corrosion and wear. It also has good osseointegration properties, which means that it can fuse with the surrounding bone tissue and create a strong bond [7]. Ti comprises of various purity degrees (grades I to IV). Following Ti as being frequently employed, apart from these, alloys of Ti, aluminum and vanadium are also utilized due to its durability and biocompatibility [811].

Zi dental implants are a newer option and have been gaining popularity in recent years. Zi is a ceramic material that is highly biocompatible and has excellent esthetic properties [12]. Zi implants have a white color that can blend in with the natural teeth, making them a good option for patients with thin or translucent gums. Zi is also highly resistant to corrosion and wear, making it a durable component in them [13].

Literature observes that Ti as well as Zi dental implants have high ScR. However, there are some differences in their performance in certain situations [1418]. Few studies have found that Zi implants may have a slightly higher risk of fracture compared to Ti implants, especially in areas of the mouth with high biting forces [1921]. Duan et al. reported that in Zi implants high failure chances due to their mechanical weakness [18] and Morena [22] concluded that. Ti dental implants have a better survival rate and less marginal bone loss than Zr dental implants after 1 year follow-up. Additionally, some research has suggested that Zi implants could show higher implant failure risk in early stages of osseointegration compared to Ti implants [16]. Advantage of Zi implants is that they are more aesthetically pleasing than Ti implants, especially in areas where the implant is visible [20]. Zi implants may also be a better option for patients who have allergies to metals or who had a higher probability of forming metal allergies [21].

Overview of systematic reviews can reach a broader area than regular systematic reviews or meta-analyses by comprehensively surveying the available high-quality evidence. Although comprehensive under certain conditions, they are meticulously designed analysis as potential comparative effectiveness stokes guidelines we suggest to apply and for an effective comprehensive strategy on a given topic. According to our knowledge, no published overview of systematic reviews among the general dentistry cohort has concisely examined the present situation and clinical usage of zirconia dental implants and compared their effectiveness with titanium counterparts. As the topic is broadly covered in the field of dentistry, such an overview of systematic reviews seems worthwhile to be carried out.

Dental implants made of titanium are currently the most frequently used fixtures in implantology and have proven their long-term clinical efficacy [23]. The main reasons for their success are attributed to excellent osseointegration and ability to endure occlusal loads. Despite that, concerns regarding potential esthetic limitations in the anterior region drove the exploration of metal-free materials, like zirconia, among researchers and clinicians [24]. Zirconium dioxide implants were originally designed as an alternative for patients allergic to titanium or concerned about sensitivity to metal. However, the given implants—alike their predecessors, ceramics and carbon implants of the past decades—posing a controversial alternative to titanium, due to relatively poor mechanical properties. As the demand for zirconia dental implants keeps growing and there is a proven interest in this topic, it seems important to summarize the available literature under the overview of systematic reviews that have the potential to guide clinicians towards the most appropriate solutions.

Overall, both Zi and Ti dental implants are feasible tooth replacement choices for patients. Though many evaluations have been published, no clear proof is available with respect to clinical performance of implant substances as it is dependent on variables such as general health, implant placement, and cosmetic preferences. This overview of systematic reviews aimed to compare clinical performance of Zi versus Ti dental implants in the anterior area.

Materials and methods

The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) 2020 statement was employed to execute our the overview of systematic reviews (SR), as it has widespread acceptance, comprehensive structure, and emphasis on transparency and rigor. This overview of systematic reviews was conducted in accordance with Cochrane Handbook for Systematic Reviews of Interventions. This overview of SRs was registered with International Prospective Register of Systematic Reviews (PROSPERO) (Registration Number CRD42023396206). The PRISMA 2020 statement was employed to ensure transparency and rigor in reporting, as recommended by Moher et al [25]. PRISMA provides a structured approach to documenting literature searches, inclusion criteria, and data synthesis, thereby minimizing bias and enhancing reproducibility.

  • Focused question

The PICO-focused question of this overview of systematic reviews was “What are various factors influencing the clinical performance of Zi versus Ti implants in the anterior area?”, focusing on:

P-Population: Healthy or diseased patients with dental implants in anterior region

I-Intervention: Zirconia or Zirconium oxide implant

C-Comparison: Titanium implant

Outcomes: Any relevant outcome of clinical performance but not limited to; implant survival rate (ISR), ScR, marginal bone loss (MBL), peri-implant soft tissue status, and biologic and functional complications of implants.

Data extraction was conducted using a pre-designed form based on the PICO framework (Population, Intervention, Comparison, Outcome). The PICO framework is a well-established approach in evidence-based medicine for structuring research questions and synthesizing data systematically [26].

  • Inclusion and exclusion criteria

The criteria for the study inclusion were as follows: Systematic reviews with or without meta-analysis evaluating the analyzed outcomes of Zi and Ti implants. The exclusion criteria were as follows: Systematic review of in vitro studies, systematic reviews of animal studies, studies focused on the implant–abutment interface, studies comparing titanium and zirconia abutments and it clinical effect. Other forms of studies such as randomized control studies, case reports, laboratory studies, uncontrolled trials, duplicate reviews, comments, and editorials were excluded. Studies not meeting the inclusion criteria were excluded.

  • Search Strategy

A comprehensive search of the literature was done from inception to January 15, 2025, including PubMed, Scopus, Embase and Google Scholar for systematic reviews with or without meta-analyses (MA).

There were three steps in the approach that were followed for gathering systematic data. Step 1: Two impartial reviewers evaluate and filter the data. Reviewers first examined the titles of the papers they had gathered, either electronically or manually. Step 2 comprised of examining the abstracts. The two reviewers then looked over the entire texts of the papers in step 3. In case there was any uncertainty or dispute among the reviewers, the work was included for further screening. The third evaluator then made final decision. The PRISMA 2020 Flow Diagram presented in Fig. 1 shows the method of data selection (represented in Supplementary table 1). Using Cohen's kappa, the Inter-reviewer reliability was evaluated. The K values were found for Google Scholar (K=0.82), Ebsco Host (K=0.81), and PubMed (K=0.82).

  • Screening method

Fig. 1.

Fig. 1

PRISMA flowchart for the process of study selection

Two independent reviewers (S.M.A and V.M.) scanned these databases using text terms and Medical Subject Headings (MeSH) terms in the absence of any language barriers. In the search algorithm, the following keywords were used (“Titanium”[Mesh] OR “Zirconium” OR “Zirconia oxide”] AND (“Dental implants” [Mesh] OR “Crowns” [Mesh] OR “Dental Prosthesis” [Mesh]).

Following the procedure set for data collection, the number of retrieved citations was noted, and duplicates were removed. The two reviewers (S.M.A. and V.M.) independently reviewed all the studies that were initially found through electronic searches. The full texts were then acquired and examined for potential inclusion and exclusion. Studies that failed to meet the requirements for inclusion were discarded. Any disagreements were resolved through discussion or by consultation of third reviewer (S.C.). The included articles were manually snowballed for any further SRs alone or without MA that might be significant. Contact with authors was done in case of missing or insufficient information.

  • Data extraction

Two assessors extracted pertinent data from selected studies separately with a pre-designed data gathering form, and any inconsistencies were sorted by deliberation among the assessors. Basic information of studies (study ID, title, authors,), participants, intervention, comparison, search details (search method, databases), range of studies selected, sources searched, type of studies selected, appraisal (appraisal rating, tool employed), results (list of outcomes, results of study), significance of review and heterogeneity were the major elements of the data extraction.

  • Quality assessment

For evaluating the methodological quality of this SR’s with or without MA, we used the JBI critical appraisal checklist for SRs [27]. There were 11 questions to guide appraisal of SR or MA. Every question was answered as “yes”(Y), “no”(N), or “unclear”(U). Not applicable “NA” was also an option. Scores were assigned for conformance to each of the 11 questions, with a min of 1 and a max of 11 indicating a well-conducted review. The two reviewers made decisions on research quality and eligibility, and any ambiguities were settled through discussion or by consultation of third reviewer (S.C.). The JBI critical appraisal checklist was utilized to evaluate the methodological quality of included systematic reviews (Table 1). This tool is widely recognized for its ability to assess the reliability and validity of evidence across various study designs, as highlighted by Munn et al. [28]

Table 1.

Risk of bias assessment by Joanna Briggs Institute (JBI) evaluation checklist

Elnayef_2017 [15] Comisso_2021 [14] Fernandes_2022 [16] Sales_2023 [17] Duan_2023 [18] Morena_2024 [22]
Is the review question clearly and explicitly stated? Y Y Y Y Y Y
Were the inclusion criteria appropriate for the review question? Y Y Y Y Y Y
Was the search strategy appropriate? Y Y Y Y Y Y
Were the sources and resources used to search for studies adequate? Y Y N Y Y Y
Were the criteria for appraising studies appropriate? Y Y Y U Y Y
Was critical appraisal conducted by two or more reviewers independently? Y Y Y U Y Y
Were there methods to minimize errors in data extraction? N Y Y Y Y Y
Were the methods used to combine studies appropriate? U Y Y U Y Y
Was the likelihood of publication bias assessed? N Y Y Y N U
Were recommendations for policy and/or practice supported by the reported data? N Y Y Y Y Y
Were the specific directives for new research appropriate? Y Y Y Y Y Y

Also, table 2 presents the appraisal tool “Measurement Tool to Assess systematic Reviews” (AMSTAR-2). AMSTAR 2 is a rating system that focuses on specific domains, encompassing seven essential domains and nine additional non-essential domains. Rather than producing a single total score, AMSTAR 2 assesses the overall quality by examining performance across both critical and non-critical domains, with each category receiving different levels of importance according to the established rating criteria, as previously used by Li et al. [29] Two reviewers, conducted an independent assessment of each study included in the review using the AMSTAR 2 online checklist. Any disagreements that arose during this process were resolved with the assistance of a third reviewer, who referenced the original AMSTAR 2 publication, its supplementary materials, and relevant sections. The critical and non-critical domains evaluated are presented in Table 2, with seven falling into critical criteria and nine into non-critical ones. The findings for all 16 domains were documented, with each response categorized as either “yes” or “no” based on AMSTAR 2 guidelines. If a more than 2 domains received a “no” response, it was deemed “low.”

Table 2.

Quality assessment of included SRMAs using AMSTAR 2

S.no. Domains (non-critical -NC/ critical-C) AMSTAR 2 checklist domains Elnayef_2017 [15] Comisso_2021 [14] Fernandes_2022 [16] Sales_2023 [17] Duan_2023 [18] Morena_2024 [22]
1 NC Did the research questions and inclusion criteria for the review include the components of PICO? Y Y Y Y Y Y
2 C Contain an explicit statement that the review methods were established prior to the conduct of the review and justify any significant deviations from the protocol N Y Y Y Y Y
3 NC Did the review authors explain their selection of the study designs for inclusion in the review? Y Y Y Y Y Y
4 C Did the review authors use a comprehensive literature search strategy? Y Y Y Y Y Y
5 NC Did the review authors perform study selection in duplicate? Y Y Y Y Y Y
6 NC Did the review authors perform data extraction in duplicate? Y Y Y Y Y Y
7 C Did the review authors provide a list of excluded studies and justify the exclusions? Y Y N N N Y
8 NC Did the review authors describe the included studies in adequate detail? Y Y Y Y Y Y
9 C Did the review authors use a satisfactory technique for assessing the risk of bias in individual studies that were included in the review? Y Y Y Y Y Y
10 NC Did the review authors report on the sources of funding for the studies included in the review? N N Y N N N
11 C If meta-analysis was performed did the review authors use appropriate methods for statistical combination of results? Y No meta-analysis conducted No meta-analysis conducted Y Y Y
12 NC If meta-analysis was performed, did the review authors assess the potential impact of risk of bias in individual studies on the results of the meta-analysis or other evidence synthesis Y No meta-analysis conducted No meta-analysis conducted Y Y Y
13 C Did the review authors account for risk of bias in individual studies when interpreting/ discussing the results of the review? Y No meta-analysis conducted No meta-analysis conducted Y Y Y
14 NC Did the review authors provide a satisfactory explanation for, and discussion of, any heterogeneity observed in the results of the review? Y Y N Y Y N
15 C If they performed quantitative synthesis did the review authors carry out an adequate investigation of publication bias (small study bias) and discuss its likely impact on the results of the review? Y N N N Y N
16 NC Did the review authors report any potential sources of conflict of interest, including any funding they received for conducting the review? Y Y Y Y Y Y
Overall assessment Low Low Critically low Low Low Critically low

Results

The flowchart of the process of selecting articles is as shown in Fig. 1. The original search in PubMed, Scopus, Embase and Google Scholar yielded 1669 studies. Following an evaluation of the duplicate records, 215 were removed and 1454 studies were chosen for screening. After examining the title, abstract, and inclusion/exclusion criteria, 1395 papers were excluded. A total of 59 full-text papers were reviewed for eligibility, with 53 of them being irrelevant. Ultimately, the overview of systematic reviews included six studies [1418, 22]. Thus, a total of 6 research articles from the selected reviews, were considered for the evaluation.

All included reviews explicitly mentioned the review subject in the title, abstract, or body. Average quality score of these selected systematic reviews was 9 ± 1.58. The research sources, evaluation standards, and independent appraisal were all suitable in 75% (4) of the reviews. In addition, techniques for reducing errors and publishing bias were not addressed in 25% (2) of the studies. For 50% (3) of the reviews, the techniques used to combine papers were suitable.(Table 1).

The critical appraisal of included studies using the AMSTAR2 method revealed that two [16, 22] of them had critically low levels of evidence, while the remaining four [14, 15, 17, 18] had low levels of evidence (Table 2). The critical areas of flaws were usually because of not providing the list of excluded studies (3/6), non-reporting of funding sources (5/6), and non-reporting of publication bias (3/8).

Database sources utilized in the selected reviews were minimum of 2 and maximum of 5. Tables 3 and 4 summarize basic and clinical characteristics of the selected reviews.

Table 3.

Baseline characteristics of systematic reviews

ID Study Participants Intervention Comparison Search details Sources searched Range of studies included Types of studies included Appraisal
Elnayef [15] Partially and fully edentulous patients Zirconia dental implant Titanium dental implant (edentulous jaw[MeSH terms]) OR jaw, edentulous, partially[MeSH terms]) OR edentulous mouth[MeSH terms]) AND dental implantation, endosseous[MeSH terms]) OR dental implant[MeSH terms]) OR dental implantation, endosseous[MeSH terms]) AND zirconium[MeSH terms]) OR zirconia[all terms] Filters: Clinical Trial; Humans; English MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Cochrane Oral Health Upto July 2015 Clinical trial Two reviewers designed and assessed the proposal for the present project to make sure the STROBE statement and PRISMA guidelines were followed to avoid risk of bias and provide a high level of evidence. The STROBE statement consists of a 22-item checklist that should be fulfilled in a systematic review. PRISMA consists of a 27-item checklist and a four-phase flow diagram. 35 The authors used the NOS to assess the risk of bias in nonrandomized studies. Cohen’s kappa coefficient was used to assess interrater agreement. The authors used the randomized clinical trial checklist of the Cochrane Center and the CONSORT to evaluate the quality of RCTs
Comisso [14] adult subjects partially edentulous in the upper-anterior sector Zirconia dental implant titanium dental implant (partially edentulous OR aesthetic sector OR upper maxilla OR upper anterior maxilla) AND (zirconia dental implants OR zirconium oxide OR dental implants) AND (titanium implants OR dental implants) AND (gingival index OR bleeding on probing OR peri-implant bleeding OR peri-implant health index OR peri-implant PD OR pink aesthetic score OR white aesthetic score) MEDLINE via Pub-Med and Cochrane Central until January 2020 experimental, epidemiological studies, quasi-experimental or analytical studies (cohort studies) and intervention (clinical trial, field trial, community trial) in humans

A judgment (high, low, or uncertain) was used to assess bias for specific aspects across five domains: Bias resulting from the randomization procedure; bias resulting from variations from planned interventions; bias resulting from incomplete outcome data; bias resulting from bias in outcome assessment; and bias resulting from preference in chosen reported result. When a trial is deemed to have a low risk of bias across all domains, it is often regarded as having a low risk of bias

Unclear if the test is decided to raise some concerns in at least one area for this result, but not to be at high risk of bias for any domain and High

Risk of preference if the study is judged to be at high risk of bias in at least one area for this result or the trial is decided to have some concerns for multiple domains in a way that substantially lowers confidence in the result

Fernandes [16] partially and fully edentulous patients zirconia or titanium-zirconium implants titanium implant ((“Dental Implants” (MeSH Terms)) OR (Dental Implant† (Supplementary Concept))) AND ((“Zirconium” (MeSH Terms)) OR (Zirconium Oxide (Supplementary Concept)) OR (Zirconia (Supplementary Concept)) OR (Yttria Stabilized Tetragonal Zirconia (Supplementary Concept)) OR (“Ceramics” (MeSH Terms))) MEDLINE/PubMed and Web of Science January 2010 and December 2020 RCTs

The randomization procedure, baseline-similar groups, blinded group assignment, random housing, blinded interventions, random and blinded outcome evaluation, dropout reporting, and other funding-related biases were all taken care of

One red box or two yellow boxes indicated the presence of bias for the particular study that was included. It could only be declared that there was no prejudice if every box was green

Sales [17] edentulous patients Zirconia dental implant titanium dental implant until march 2022 RCTs 2 independent reviewers assessed the study, none of the study had risk of bias
Duan [18] Partially and fully edentulous patients Zirconia dental implant Titanium dental implant

Cochrane Central Register of Controlled Trials (CENTRAL), Medline via Ovid, EMBASE,

and Web of Science were searched

From Inception to August 2022 RCTs

Two authors manually searched the reference lists of the included papers to find possible related studies

Using RevMan software, the Cochrane Risk of Bias Assessment Tool was used to assess the bias of the included RCTs. Due to substantial loss during follow-up or baseline incomparability between the control and experimental groups, two studies were deemed to have an elevated risk of bias. Furthermore, it was unclear whether this study had a bias risk

Morena [22] partially and fully edentulous patients Zirconium implants Titanium dental implant

Dental implants AND Zirconia implants OR zirconium implants OR

titanium implants OR zirconium oxide OR Yttria Stabilized

Tetragonal Zirconia

; Dental implants AND Zirconia implants OR zirconium implants OR

titanium implants OR zirconium oxide OR Yttria Stabilized

Tetragonal Zirconia

; (ALL = (Dental implants AND Zirconia implants OR zirconium

implants OR titanium implants OR zirconium oxide OR Yttria

Stabilized Tetragonal Zirconia)) AND ALL = (Randomized

Controlled Trial)

MEDLINE/PubMed and Web of Science, Scopus Last 10 years -upto April 2024

Randomized controlled trial (RCT)

studies, and exclusively clinical and human studies involving adult patients

Two independent authors (T.B. and D.M.) conducted the electronic search on three

databases: Medline/PubMed, Scopus, and Web of Science (WoS). In case of disagreement, a

tie-break was performed by a third author (G.V.O.F.). The PICO question guided the search

parameters, and search filters were applied

The quality of the conducted study was independently assessed by two authors (T.B

and D.M.). In the case of disagreement, a third author was consulted (G.V.O.F.). The risk

of bias in the considered RCTs was evaluated using a Cochrane risk-of-bias assessment

tool specifically designed for randomized trials (RoB2)

STROBE: Strengthening the Reporting of Observational studies in Epidemiology; MeSH: Medical Subject Headings; RCT: Randomized controlled trial

Table 4.

Clinical characteristics of systematic reviews

Study ID Appraisal instrument used Methods of analysis Outcomes assessed Results/findings Significance/direction Conclusion
Elnayef [15] Newcastle–Ottawa scale Estimates were obtained for a random effects model. For the solution of the MA, OR estimates are accompanied by 95% confidence intervals and the P value of the null effect of the type of implant factor (OR = 1). Graphical representation is made by means of a forest plot for OR and for the natural logarithm of the OR (making estimates symmetrical around 0 and favoring the adjustment to the normal). For analysis of MBL (continuous variable), the weighted mean difference was used as a measure of overall size effect. The significance level used in the analysis is 5% (α = .05). MBL was analyzed as a subject unit, and implant ScR and ISR were analyzed as an implant unit Primary outcomes are ISR and ScR; secondary outcomes are MBL and the influence of other possible confounding factors on ISR and ScR 3 studies were included in the quantitative synthesis and were meta-analyzed for the comparison of ISR between Zi and Ti implants, with Zi implants having an 89% greater risk of failure compared with Ti implants (OR = 1.89). There were no statistically significant differences (P = .968) in the ScR of Zi and Ti implants (odds ratio [OR] = 1.02; 95% confidence interval [CI], 0.47–2.20). MBL (± SD) for Zi implants was 0.89 ± 0.18 mm, which was greater than the MBL for Ti implants (mean difference = 0.14 mm). Also, ISR of Zi implants (91.5%) was significantly lower than that of Ti implants (OR = 1.89). Metaregression analysis revealed a similar ISR for one-piece versus two-piece implants. Similarly, no significant differences were found between immediate and delayed loading The estimated mean ISR for Zi implants was 74.8% (OR = 1.89; 95% CI, 1.00–3.56), which was statistically significantly lower than the mean ISR of 85.7% for Ti implants. The estimated mean ScR for Zi implants was 91.6% (two studies included) (OR = 1.02; 95% CI, 0.47–2.20), which was not statistically significantly different from the ScR for Ti implants (P = .968) The ISR of Zi implants was significantly lower than that for the commonly used Ti implants. However, for certain clinical conditions, such as a thin tissue biotype or in the highly esthetic anterior area, Zi implants may offer some benefit when compared with Ti implants
Comisso [14] other than RCT was assessed using the Newcastle–Ottawa Scale, RCT by Cochrane collaborations’ tool The articles were compared, and the mean values of the primary variables were directly grouped and analyzed using standardized mean difference (SMD) and 95% confidence intervals (CI). All analyses were performed with the IBM® SPSS® Statistics version 21.00 software. Statistical significance was defined for a value of p < 0.05 aesthetic score, white aesthetics score, the peri-implant, and crown index, BOP, PI, PD, radiographic MBL, papilla height, and ISR and ScR Different measures for oral hygiene (PI, BoP, PPD) and aesthetics (PAS, WAS, PCI), as well as, ISR and ScR had been compared between zirconium dioxide and titanium implants. Zirconium dioxide implants have shown improved aesthetic benefits in the PAS and WAS compared to conventional titanium implants. Zirconium dioxide implants have other clinical benefits compared to conventional titanium implants, showing less plaque accumulation and, therefore, less inflammation around the peri-implant mucosa. Zirconium dioxide implants have shown a lower PD and an ideal papilla crown proportion with increase in papillary height. For ISR and ScR not significant statistical differences were found between groups For ISR and ScR not significant statistical differences were found between groups Despite the optimal aesthetics, clinical and ISR results obtained in the review, more studies are needed to confirm these data
Fernandes [16] The Cochrane risk-of-bias tool for randomized trials version 2 (RoB 2) Clinical outcomes (ISR, ScR, MBL, PD, BOP, and osseointegration level) The follow-up periods ranged from 12 to 80 months, and the mean age was from 43.3 to 65.8 years old. The SR for Ti, TZ, and Zr implants ranged from 92.6% to 100%, 95.8% to 100%, and 87.5% to 91.25%, respectively; MBL for Ti, TZ, and Zr implants varied from -1.17 mm to -0.125 mm for Ti, -0.6 mm to -0.32 mm for TZ, and-0.25 mm to -1.38 mm for Zr. Studies showed a low incidence of mucositis and peri-implantitis; however, BoP for Zr was 16.43%, Ti ranged between 10 and 20%, and TZ from 10% to 13.8%. PD for Ti ranged from 1.6 mm to 3.05 mm, TZ was 3.12 mm (only one study), and Zr ranged from 2.21 mm to 2.6 mm Although two studies did not find a significant statistical difference between titanium and zirconia groups for implants loss, one other [25] concluded that Ti implants had a superior SR than Zr, in line with the literature, which showed a significant difference between them, Within the limitations of this systematic review and after carefully analyzing all the data, it was possible to conclude that all types of evaluated implants had similar results when analyzing tissue response and behavior, suggesting that Ti, Zr, and TZ implants all allow for a feasible and reliable treatment. However, TZ had a better result when compared with Ti and Zr for SR, MBL, and BoP, and the worst SR was found in the Zr implants group
Sales [17] 3235 studies were initially found in the researched databases. 03 randomized clinical trials were included in this SRMA. A total of 71 patients with 192 implants (87 titanium and 105 zirconia) were evaluated, showing an effectiveness of 87,4% and 78,1% respectively and there was no statistically significant difference in terms of ISR in the MA (P = 0.70; I2 = 0%). Still in the MA, there was no statistically significant difference between titanium and zirconia implants in relation to the pink esthetic score or BOP, however, a favorable difference was observed for titanium in relation to marginal MBL (P = 0.001; I2 = 0%). None of the studies evaluated had a low risk of bias Oral rehabilitation with zirconia implants showed no advantages over titanium in this systematic review. However, the small number of studies included and the uncertain risk of bias may raise doubts in this interpretation and the results should be analyzed with caution. New studies with greater methodological rigor, follow-up time and number of interventions should be performed to safely determine the indication for the use of zirconia implants
Duan [18]

Cochrane Risk of Bias Assessment

Tool via RevMan software (version 5.3, The Cochrane Collaboration, Copenhagen,

Denmark)

In the description, dichotomous variables were expressed as a proportion of all events. The risk ratio (RR) was used to compute the difference. The mean and standard deviation were used to represent continuous variables, and pooled mean difference (MD) was used to assess differences. Additionally, the P value and 95% confidence interval (CI) were computed

The Higgins I-squared statistic (I 2) and the Cochran Chi-square test were utilized to generate a Q-test that was used to identify statistical heterogeneity in this meta-analysis

The primary outcomes (O) were survival rate, success

rate, marginal bone loss (MBL), and probing pocket depth (PPD); secondary outcomes

included plaque index (PI), bleeding on probing (BOP), pink aesthetic score (PES), and

reasons for failure

From the six papers that were reviewed, a total of four studies were included. There was little chance of bias in the evaluation of two of the comparison studies. Compared to titanium implants, zirconium implants may have a significantly lower success rate (RR = 0.87, CI [0.78–0.98], P = 0.030, I2 = 0%) and a worse survival rate (RR = 0.91, CI [0.82–1.02], P = 0.100, I2 = 0%). Furthermore, no significant differences were seen between the zirconium and titanium implants concerning MBL, PPD, plaque index (PI), bleeding on probing (BOP), or pink esthetic score (PES) (MD =  − 0.07, CI [− 0.19–0.05], P = 0.250, I2 = 31% for PPD and MD = 0.25, CI [0.02–0.49], P = 0.033, I2 = 0% for MBL) The survival rate, PPD, BOP, PES, and success rates were all degraded to moderate, while the MBL and PI were extremely low. Limitations in the study's quality, inconsistent results, or imprecise study design all detracted from the evidence's grade. Zirconium implants are mechanically weak, failure rates may be higher
Morena [22]

Cochrane risk-of-bias assessment

tool specifically designed for randomized trials (RoB2)

The domains of the tool (RoB2)

included the randomization process, deviations from the intended interventions, missing

outcome data, outcome measurement, and selection of reported outcomes. The options to

qualify each item were as follows: (1) low risk; (2) some concern; and (3) high risk. In the

case of ≥ 2 “high risk”, the overall result will be “high risk”; with up to 2 “some concern”

present, a “low risk” will be found in the overall result

The primary outcomes observed were the implant survival rate, implant marginal

bone loss (MBL), and implant success rate. The secondary endpoints/outcomes were as

follows: bleeding on probing (BoP), plaque index (PI), pink esthetic score (PES), and reasons

for failure

Ti

implants had the highest percentage of successful implants after one year, and the effect of

the meta-analysis was 0.11 (95% CI [0.02; 0.20]), statistically significant (p < 0.05)

Regarding the success rate, it was better for Zr but with no statistical

difference (p > 0.05); bleeding on probing had slight differences between Ti with 0.34% ± 0.42 and Zr

with 0.26% ± 0.36 (p > 0.05); plaque score showed 0.46 ± 0.47 for Ti compared to 0.44 ± 0.49 for Zr

(p > 0.05); no statistically significant difference was observed for pink esthetic score (PES)

Statistically

significant results were found for survival rate, which favored Ti implants (77.6%) compared to Zr

(70.3%) (p < 0.05), and for marginal bone loss, which showed less loss in Ti implants (0.18 mm ± 0.47)

compared to 0.42 mm ± 0.40 in Zr at 12 months (p < 0.001)

Ti dental implants have a better survival rate and less

marginal bone loss than Zr dental implants after 1-year follow-up

Comisso study selected using Cochrane Central Register of Controlled trials and MEDLINE via Pub-Med [14]. Elnayef study inspected with MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and Cochrane Oral Health Group Trials Register [15]. Fernandes studys creened in MEDLINE/PubMed and Web of Science, whereas Sales study extracted from Medline, Central Cochrane, Scopus, LILACS and Google Scholar [16, 17]. Apart from these databases, to ensure comprehensive search, all the studies had performed manual search of the references from the included studies or the dental journal. Duration for which literature was screened was available in all the selected reviews. Comisso study and Fernandes study selected studies from 2010 to 2020 [14, 16]. Elnayef study included studies till 2015, Duan reported studies from 2014 to 2021 [18], Sales involved till 2022 [15, 17] and Morena 2014–2024 [22] (Table 3).

Both retrospective and prospective studies were part of the selected reviews. Randomized clinical trials (RCTs), Cohort and case series were evaluated. Fernandes study reviewed 7 RCTs, Sales study reviewed 3 RCTs, however, in Comisso study, out of 15 articles, 5 articles were prospective cohort studies, 3 articles retrospective cohorts, 2 retrospective case series, 2 RCTs and 3 prospective case series, whereas in Elnayef study, among the 21 articles, 5 prospective cohort studies, 8 prospective case series and 4 RCTs and 4 retrospective clinical studies, Duan study contained 4RCTs with 6 with six records [1418].

The participants in Comisso study were partially edentulous in the upper-anterior sextant, Elnayef study, Fernandes study and Sales study studied comprised of partial or completely edentulous healthy patients acquiring one or more implants. The intervention group in Comisso et al., Elnayef study and Sales study papers were Zi implants, whereas Fernandes study included Ti–Zi implants along with Zi implants. Comparator group in all the studies were Ti implants. The Duan study comprised of total of 109 participants with 248 implants with both Zi and Ti implants comparison [1418].

Among the outcome parameters assessed in these reviews, Comisso study mainly included aesthetic benefits along with clinical benefits such as white and pink aesthetic scores, peri-implant, crown indices, bleeding on probing (BOP) plaque index (PI), and probing depth (PD), MBL, papilla height, ISR and ScR; while Duan study included success rate, marginal bone loss (MBL), and probing pocket depth (PPD); secondary outcomes included plaque index (PI), bleeding on probing (BOP), pink aesthetic score (PES), and reasons for failure. The study design (S) of interest was randomized controlled trials (RCT) [1418].

Elnayef study considered clinical benefits that contained ISR, ScR and MBL [15]. Apart from these, confounding factors were also assessed. Whereas Fernandes, Duan and Sales study included clinical benefits similar to Elnayef study BOP, PD and confounding factors that is implant features and patient habits were also included by Fernandes study [1518].

Evaluation of quality of RCTs was done with Cochrane collaborations’ tool in all studies, and other than RCTs was done with Newcastle–Ottawa Scale [30]. The majority of the studies examined by Comisso study did not compare Ti implants to Zi implants, but rather examined the attributes of Zi dioxide implant [14]. Hence, the study design was not consistent. Duan included studies comparing the Zi and Ti implants. He reported that the success rates were downgraded to moderate, the survival rate, PPD, BOP, and PES were low, and the MBL and PI were very low. Eighteen of the selected articles in Elnayef review were discarded as they had no comparison between Zi implants and Ti implants [15].

Table 4 summarizes the major results (clinical aspect) of the systematic reviews. The number of papers that comprised those systematic reviews ranged from 3 to 21. There were 2020 participants in total from all the four reviews, as the gender and age differentiation were not available for Elnayef study and Sales study had 329 males and 339 females with an average 54.45 years of age, with a follow-up ranging between 12 and 84 months [1417]. Duan study had total of 109 subjects with 248 implants [18] and Morena study had 6 RCTs; 152 patients (90 males and 62 females) and 448 implants (267 Zi and 181 Ti).

Ti implants showed better ISR than Zi implants in 75% of reviews. According to current research, conventional all-Ti implants had a longer ISR, whereas all-Zi implants have a short ISR. Elnayef study concluded that ISR of Zi was considerably lower than Ti [15]. Comisso study found a statistically insignificant variation between the two categories [14]. Regardless of the follow-up time, all trials examined by Fernandes et al. resulted in higher ISR with Ti compared to Zi [16]. According to Sales study Ti has a higher ISR percentage than Zi [17]. While Sales' total ISR was poor, compared to other systematic reviews [17].

Our findings indicated that systematic studies primarily led to Ti implants showing greater ScR than Zi implants. Elnayef study conducted a comprehensive analysis and discovered a statistically insignificant difference for Zi and Ti implants ScR [15]. Morena et al. [22] reported in their review that Ti dental implants have a better survival rate and less marginal bone loss than Zr dental implants after 1-year follow-up. Fernandes study and Sales study both found similar findings in their comprehensive reviews [16, 17]. In comparison, a study by Comisso study found Zi to be superior to Ti, but the difference was statistically negligible [14]. However, in terms of aesthetics, both Zi and Ti were similar, in few studies’ Zi was better than Ti. Ti implants were found to be superior in terms of peripheral MBL in 75% of reviews. Elnayef reported higher MBL for Zi [15]. In Comisso study, no conclusive evidence is obtained regarding MBL [14]. MBL of Ti and Zi implants remained constant in follow-ups of the papers reviewed by Fernandes study but, all the study had a short follow-up time [16]. Significant difference in MBL was reported by sales study that favoured Ti implants [17]. As an outcome, no definitive evidence pertaining the MBL was obtained in the present comprehensive analysis.

Discussion

With the growing number of recently published systematic reviews, an evaluation of these reviews is an essential next step in providing a high-level evidence base for clinical practice. This overview of systematic reviews was conducted to summarize the findings of systematic reviews and meta-analyses investigating clinical endpoints of zirconia dental implants. This is the first comprehensive review of this type which compared the efficacy of Zi and Ti dental implants in the anterior area. By conducting an overview of systematic reviews, we would like to less the bias and variance in the adopted literature sources and evidence. This motivation is consistent with what Ioannidis et al. noted for evidence-based medicine: observable associations do not identify causal ones, overwhelmingly, suggests that surprising and challenging results often suffer from the high bias and the low-positive prediction value. By this limitation, we searched electronically and manually and could retrieve only 4 articles based on inclusion and exclusion criteria. This caused a smaller sample size. Still, this could show clinical efficacy of Zi and Ti dental implants in the anterior area.

The results of this overview of systematic reviews demonstrate that zirconia implants offer a viable treatment modality for replacing missing teeth in the anterior region. Notably, zirconia implants exhibit similar marginal bone loss to titanium implants for a single restoration with good patient satisfaction, sufficient survival and success rates, and comparable prevalence of peri-implant diseases compared to titanium implants [31]. An important point to underscore is that zirconia implants were more often associated with mechanical and technical complications compared to titanium implants. This overview of systematic reviews revealed a longer treatment time and possibly greater prosthodontic complications with zirconia implants despite no significant difference in implant survival between the two materials.

A study from Linkevicius et al., 2015 was excluded in the present study as the review considered only soft tissue biotypes [32]. Another systematic review by Cao et al., 2019 was also excluded as it was focused on the implant–abutment interaction specifically, the survival rate of titanium implants with zirconia abutments and clinical trials reporting the effects of implants with zirconia abutments [33].

Comisso study identified 1109 papers, after removing duplicates 1104 were screened, of which 633 were evaluated as suitable, but after full text screening only 15 were chosen for the final analysis [14]. Elnayef study identified 193 studies, 117 were screened, and 58 were found eligible, out of which 21 were eligible for analysis [15]. Fernandes study identified 415 records, but 217 were duplicates, so 198 were screened for eligibility and 7 were eligible and included for analysis [16]. Sales study identified 3235 articles,and eliminated 3211 were eliminated at the screening stage, 24 articles were assessed for eligibility, and 3 RCTs were considered for analysis [17].

In paper by Comisso study Zi dioxide implants had higher ScR and ISR, ranging 50% to 100% which could be because heterogenic studies in all reviews or a variation of the time for estimating the ScR and ISR [14]. Elnayef study found Zi implants ScR was 91.6 percent [15]. There were no significant variations about efficacy of Zi and Ti implants. Even though Zi implants do not have as much history as Ti implants. Dental implants made of Ti have an exceptionally high ScR (96.4%) over 10 years, in contrast to 87% and 100% ISR from the latest literature on Zi implants, where post evaluation period ranged from one to eight years [34].

Analysis in Elnayef review revealed the mean ISR for Zi ones was 74.8% (OR = 1.89; 95% CI 1.00–3.56), substantially lower than mean ISR for Ti implants (85.7%) [15]. Zi implants have an 89% higher failure rate than Ti implants. Following a mean post op period of 42.37 months, Zi implants had a 91.5% ISR and a 91.6% ScR, according to the Elnayef study MA [15]. After 12 and 21 months, Andreiotelli study demonstrated a ISR of 98% and 84%, respectively [35]. In Fernandes review, ISR for Zi was 87.5–91.2%, for Ti-Zi 95.8–100%, and for Ti 92.6–100% [16]. Ti implants outperformed Zi implants in terms of ISR. Ti-Zi implants have a similar ISR to Ti implants but a higher ISR than Zi implants. Ti-Zi implants were taken into consideration since they are a mixture of both of the materials that were researched and typically consist of 85% Ti and 15% Zi, which enables a direct comparison. These findings need to be supported by research conducted over extended time periods with extensive follow-ups. According to studies, Ti implants have ISR of over 95% after 10 years; therefore, Ti is preferred as the primary implant material [3638]. In Sales review, ISR of Ti (87.4%) was better than Zi (78.1%), however, with a statistically insignificant variance [17]. One potential explanation for the paradox is the mechanical weakness of Zi implants. Narrow implants have worse ISR than standard-diameter implants [39]. However, the increased rate of failure could be attributed to the research approach instead of the material.

Survival rate is a fundamental parameter for the evaluation of the clinical performance and acceptance of different implant biomaterials. In our overview of systematic reviews, survival rate ranged from 65.0 to 100.0% for Zirconia implants and 90.0 to 100.0% for Titanium implants. This result indicates that both Titanium and Zirconia implants have high stability in the anterior part of the dental arch after a 1–5 years follow-up period. Good survival rate is an essential standard to evaluate the clinical use of Zirconia implants, which could decrease concerns due to the premium price of the material. The Duan reported the ISR of Zi implants as 92.77, 98.58, and 86.38% at one, two and five follow-up years, respectively, while the success rate was 84.89, 80.78, and 66.38%, respectively [18].

There is a visible display of the metal components due to MBL and minor recession of tissue [40]. However, it is stated that it was related to the cementation [14, 4143]. Radiographic bone loss is not clearly reported by Comisso study but overall clinical benefits support Zi [14]. In Elnayef study analysis, statistically noteworthy difference for the marginal bone loss for Zi implants (0.89 ± 0.18 mm), more compared to MBL for Ti implants (mean difference = 0.14 mm) was reported [15]. In Fernandes review, MBL for Ti ranged between 0.125–1.17, for Zi 0.25–1.38 and for Ti-Zi 0.32–0.60 [16]. Koller's research exhibited the highest MBL for Ti, which might be due to the longer duration of analysis and the method of restoration [44]. MBL of Ti and Zi implants remained constant postoperatively. Trials were noted to have shorter postoperative durations. Even though the MBL for Ti-Zi implants was similar to Ti and Zi, It ought to be mentioned that only a limited number of Ti-Zi ones were tested, which may make it difficult to draw definitive conclusions [16]. In Sales review, favorable difference was seen in Ti with respect to MBL [17]. The meta-analysis by Morena et al. [22] reported an effect size of − 0.61 (95% CI [− 0.83; − 0.39]), which was statistically significant (p < 0.001), indicating that MBL outcomes were notably lower in titanium implants than in zirconium implants across the studies reviewed. Additionally, Cochran’s Q value was found to be p = 0.59 and I [2] = 0%, leading to the conclusion that there was no heterogeneity among the studies regarding this parameter.

Zirconia is an esthetic alternative to titanium for dental implants [45]. Zirconia dental implants have shown similar clinical outcomes to titanium implants in terms of aesthetics, plaque control, and peri-implant bone level. A recent meta-analysis stated that survival rates for short Zr implants were lower than long ones but these differences were not statistically significant [46]. The success rate of Zr implants is 95 to 97%. The Morena et [22]al stated that the success of Ti implants after one year was statistically significant compared to Zi implants in the analyzed studies. Based on the results, Cochran’s Q (p = 0.77) and I2 = 0%, there was homogeneity among studies for this parameter in their review. The prevalence (12.92%) of technical complications associated with Zr implants is comparable to or lower than those for Ti implants, while biological complications are primarily caused by peri-implantitis and seem to be higher (14.1%) compared to 5 to 10% for Ti implants [47]. Most of the technical complications are screw loosening, abutment fractures, and ceramic veneer chipping. Other authors found higher technical and biological complications for Zr implants, including fracture of implant body, higher inflammation grades, and mechanical complications compared with Ti implants. Titanium implants demonstrated superior survival and success rates in most studies, underscoring their well-documented mechanical reliability and osseointegration properties [16, 22]. Despite these strengths, titanium’s esthetic limitations and potential for metal allergies necessitate exploring alternatives like zirconia. The higher failure rates and increased risk of mechanical complications with zirconia implants, as reported in the included studies [16], emphasize the need for caution when selecting zirconia for load-bearing or high-biting-force regions. In Comisso review [14], different research has found that Ti implants had lower values for pink, white aesthetics, and the peri-implant and crown index [4850]. Zi implants have a superior colour perception than Ti implants, but the distinction is only noticeable in thinner, soft tissue biotypes [35, 49]. In the selected studies, different indices are reported for the aesthetic outcome. This shows the esthetic assessment’s complexity in the reviews. In vitro experiments have revealed that the texture of the implant material has a significant impact on the cells' adherence [51]. Also, it is speculated that PD around implants could be reduced if the cells adhere better [32]. Sales study reported statistically insignificant difference for pink aesthetic score [17].

Morena et al. emphasized the exceptional aesthetic qualities of zirconia implants, especially when used in cases involving thin or translucent gum types. The color of zirconia closely resembles that of natural teeth, which significantly lowers the chances of visible metal near the front of the mouth. This characteristic is vital for individuals who place a great emphasis on visual appeal, particularly in situations with noticeable smiles [18, 22]. Furthermore, zirconia is known for its biocompatibility, making it an attractive option for patients who might have sensitivities or allergies to metallic materials, thus expanding its accessibility to a larger patient base. Nevertheless, these advantages come with the necessity to consider the mechanical drawbacks of zirconia, particularly its lower resistance to fractures when subjected to significant biting forces [9]. Clinicians must also keep in mind the specific techniques required when utilizing zirconia implants. Due to its brittle composition, careful surgical and prosthetic methods are essential to reduce the likelihood of fractures occurring during installation or use.

Due to lesser affinity of the Zi dioxide surface, there was less plaque buildup, allowing for a reduced likelihood of inflammation and infections [14, 52]. Researchers discovered that Zi implants had less bacterial attachment than Ti implants, that could result in less inflammation, eventually, in a lesser cases of mucositis, peri-implantitis, or both [53]. But in Elnayef study, due to study heterogeneity, peri-implant parameters like BOP, PI, and PDs could not be statistically assessed [15]. As reported in Fernandes review, mucositis and peri-implantitis was neither reported nor noticed in the two investigations [6, 15, 53]. Three other studies did not investigate if mucositis was present [44, 5457]. Only two investigations looked for mucositis: Ioannidis study found 10 Ti implants and 8 Ti-Zi implants afflicted, and Siddiqi study found no implants impacted [57, 58]. Five researchers looked at peri-implantitis. Koller study removed 1 Ti implant owing to peri-implantitis, whereas Al-Nawas study and Müller study removed 1 Ti and one Ti-Zi implant [44, 57, 58]. Ioannidis study reported two Ti-Zi implants with peri-implantitis, however, Siddiqi study reported no afflicted implants [57, 58]. Zi implants have a lesser bacterial affinity than Ti implants do when compared to the same conditions, also, consequently a lower occurrence of mucositis [59]. In addition, research that did not assess the occurrence of mucositis noted some limitations in the information obtained. Similar conclusions have been documented for peri-implantitis involving Ti and Zi implants in Fernandes review [16]. As reported by Pjetursson study in 2012, new surface technologies, materials, micro and macro designs, and significantly recognising variables impacting MBL and peri-implantitis, resulted in a sharp rise in Ti implant longevity (up to 97.2% after 5 years) [60]. Smoking was linked with significantly greater failure rates i.e. ISR, ScR and MBL [61]. However, patient habits were not reviewed in any of the included reviews.

The evidences regarding marginal bone level (MBL) do not provide definitive support for one type of implant material over the other. Even though the Titanium implants generally display slightly lower MBL, which may be attributed to their longer duration of use and improved surface treatments. This slight edge could also be the result of significant advancements in titanium implant surface modifications that enhance osseointegration and reduce bone remodeling. On the other hand, zirconia implants, although similar in MBL, have a notable advantage concerning peri-implant health due to their smoother surface and reduced bacterial attraction [62, 63]. These characteristics may help diminish plaque buildup and the associated risks of peri-implantitis and mucositis. Clinical evidence indicates that zirconia implants are associated with lower levels of inflammatory markers [16, 22], suggesting they may be more supportive of soft tissue health in specific situations. Nonetheless, the limited evidence on the long-term effects of zirconia implants on peri-implant health signifies the necessity for further investigation. Additionally, factors related to patients, including oral hygiene, smoking habits, and systemic health conditions, play a crucial role in MBL and peri-implant health [14]. Although zirconia implants may offer resistance to bacterial colonization, inadequate patient adherence to maintenance procedures could diminish these advantages. Therefore, educating patients and ensuring regular follow-up visits are essential for achieving optimal outcomes.

Fernandes study reviewed the failed implants throughout the follow-up period [16]. There were in total 24 Ti (8.48%), 1 Ti-Zi (1.03%), and 44 Zi (26.03%) implants reported. However, none of the other reviews taken this feature into assessment in their review. As the sample s less, they could not conclude if Ti, Ti-Zi and Zi variants had greater, similar or lower BOP. However, PD of Ti, Ti-Zi and Zi implants, on the other hand, appeared to be similar. Sales study, reported Ti and Zi showed statistically insignificant variations for BOP [17]. Height of the papilla was assessed only by Comisso study who reported an increase in height for Zi implants [14].

This current review finds statistically insignificant variations between Zi and Ti as implant materials with respect to ISR, SR, MBL and aesthetics. It is not feasible to make a conclusive analysis because of the wide range of studies. More trials are needed for assessing design impact and surface characterization of implant material on therapeutic efficacy and to uncover all the technical as well as biological variables that influence implant effectiveness and user contentment. However, clinical practitioners should consider both feasible, reliable, and cosmetic effectiveness when selecting implants.

Clinical performance of dental implants relies on several factors, like the patient's overall health, the clinician’s ability placing implants, and the patient's willingness to follow post-operative care instructions.

Limitations of the study

This overview of systematic reviews is subject to several limitations that warrant careful consideration. Firstly, the systematic reviews incorporated in this analysis display significant variability in terms of study designs, participant populations, and assessed outcomes, leading to a notable heterogeneity among the selected studies. Variations in inclusion criteria, techniques for implant placement, follow-up durations, and outcome metrics may have influenced the results and interpretations of this overview of systematic reviews.

Consequently, the findings necessitate cautious interpretation in light of this heterogeneity. Another noteworthy limitation is the relatively limited number of high-quality systematic reviews that conformed to the inclusion criteria. Despite an exhaustive search process, only a small subset of reviews was found eligible for this analysis, which could constrain the robustness and comprehensiveness of the overall findings. Additionally, the exclusion of non-English studies might result in the omission of pertinent research, thereby introducing potential language bias into the review.

A further concern arises from the predominantly short follow-up periods characterizing many of the included reviews, which may inadequately reflect the long-term performance dynamics of zirconia and titanium implants. Comprehensive long-term data concerning implant survival rates, marginal bone loss, and peri-implant health are critical to facilitate a more definitive comparison between these two materials. Moreover, a significant proportion of the studies examined in the included reviews failed to distinguish between various implant systems, designs, and surface treatments, all of which could substantially impact clinical outcomes.

Additionally, inconsistencies in the reporting of specific outcomes, such as peri-implant soft tissue health and patient satisfaction, were evident across the assessed reviews. This variability hinders the capacity to arrive at conclusive judgments regarding the overall clinical performance of zirconia as opposed to titanium implants. Furthermore, the absence of standardized criteria for aesthetic assessment complicates the interpretation of aesthetic outcomes, thereby limiting the thorough evaluation of this dimension in the review process.

Ultimately, the methodological robustness of the systematic reviews included in this analysis showed considerable variation. Certain reviews exhibited a heightened risk of bias, primarily attributable to insufficient transparency regarding their appraisal methods, the processes employed for data extraction, and the strategies implemented for synthesizing studies. This inconsistency in methodological rigor could have influenced the overall reliability of the findings articulated in this overview of systematic reviews.

Conclusion

This overview of systematic reviews concluded that –

  • The clinical performance of zirconia (Zi) implants is comparable to titanium (Ti) implants in the anterior area, with no significant difference recorded between the two.

  • Titanium implants demonstrate greater mechanical performance than zirconia; however, most studies do not report a significant difference in the frequency of mechanical failures.

  • Marginal bone loss is not significantly influenced by the implant material.

  • Decision-making should consider the benefits and drawbacks of each material, based on individual requirements and clinical scenarios.

This overview of systematic reviews provides valuable insights for clinical decision-making, considering patient-specific factors such as: Aesthetic priorities; Biocompatibility requirements; Functional demands. Potential applications of these findings include: Customized treatment planning; Development of patient education tools; Material advancements and design improvements.

In future, studies with improved design are needed to identify biological and technical factors that affect implant’s efficacy. The long-term studies including biomechanical analysis with patient-centric outcomes on aesthetic evaluations, biological responses, cost-effectiveness associated with advanced surface treatments and coatings for both zirconia and titanium implants that could yield details into improving osseointegration, reducing bacterial adhesion, and long-term clinically beneficial results.

Supplementary Information

Acknowledgements

The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University for funding this work through Large Research Project under grant number RGP2/251/45.

Author contributions

S.M..A, S.C. and V.M. performed conceptualization, methodology, software, validation, formal analysis, writing—original draft preparation, writing—review and editing, supervision and funding acquisition. S.M..A, S.C., M.A., M.A.A.M., V.M. and M.C. were involved in conceptualization, methodology, software, validation, formal analysis, writing—review and editing, and funding acquisition. All authors have read and approved the final version of the manuscript.”

Funding

The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University for funding this work through Large Research Project under grant number RGP2/251/45.

Data availability

No datasets were generated or analysed during the current study.

Declarations

Ethics approval and consent to participate

Not Applicable.

Consent for publication

Not Applicable.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Guillaume B. Dental implants: a review. Morphologie. 2016;100:189–98. [DOI] [PubMed] [Google Scholar]
  • 2.Raikar S, et al. Factors affecting the survival rate of dental implants: a retrospective study. J Int Soc Prev Comm Dent. 2017. 10.4103/jispcd.JISPCD_380_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Tricio J, Laohapand P, van Steenberghe D, Quirynen M, Naert I. Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method. Int J Oral Maxillofac Implants. 1995;10:43–9. [PubMed] [Google Scholar]
  • 4.Nelson C. Factors affecting the success of dental implants. In: Turkyilmaz I, editor. Implant dentistry—a rapidly evolving practice. London: InTech; 2011. [Google Scholar]
  • 5.Osman RB, Swain MV. A critical review of dental implant materials with an emphasis on titanium versus Zirconia. Materials (Basel). 2015;8:932–58. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Osman RB, Swain MV, Atieh M, Ma S, Duncan W. Ceramic implants (Y-TZP): Are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial. Clin Oral Implant Res. 2014. 10.1111/clr.12272. [DOI] [PubMed] [Google Scholar]
  • 7.Sidambe AT. Biocompatibility of advanced manufactured titanium implants-a review. Materials. 2014. 10.3390/ma7128168. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Le Guéhennec L, Soueidan A, Layrolle P, Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater. 2007. 10.1016/j.dental.2006.06.025. [DOI] [PubMed] [Google Scholar]
  • 9.Depprich R, et al. Current findings regarding zirconia implants. Clin Implant Dent Relat Res. 2014. 10.1111/j.1708-8208.2012.00454.x. [DOI] [PubMed] [Google Scholar]
  • 10.Smith DC, et al. Systemic metal ion levels in dental implant patients. Int J Oral Maxillofac Implants. 1997;12:828–34. [PubMed] [Google Scholar]
  • 11.Sykaras N, Iacopino AM, Marker VA, Triplett RG, Woody RD. Implant materials, designs, and surface topographies: their effect on osseointegration. A literature review. Int J Oral Maxillofac Implant. 2000;15:675–90. [PubMed] [Google Scholar]
  • 12.Parmigiani-Izquierdo JM, Cabaña-Muñoz ME, Merino JJ, Sánchez-Pérez A. Zirconia implants and peek restorations for the replacement of upper molars. Int J Implant Dent. 2017. 10.1186/s40729-016-0062-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Chen YW, Moussi J, Drury JL, Wataha JC. Zirconia in biomedical applications. Exp Rev Med Devices. 2016. 10.1080/17434440.2016.1230017. [DOI] [PubMed] [Google Scholar]
  • 14.Comisso I, Arias-Herrera S, Gupta S. Zirconium dioxide implants as an alternative to titanium: a systematic review. J Clin Exp Dent. 2021. 10.4317/jced.58063. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Elnayef B, et al. Zirconia implants as an alternative to titanium: a systematic review and meta-analysis. Int J Oral Maxillofac Implant. 2017. 10.11607/jomi.5223. [DOI] [PubMed] [Google Scholar]
  • 16.Fernandes PRE, et al. Clinical performance comparing titanium and titanium-zirconium or zirconia dental implants: a systematic review of randomized controlled trials. Dent J. 2022. 10.3390/dj10050083. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.da Hora Sales PH, et al. Do zirconia dental implants present better clinical results than titanium dental implants? A systematic review and meta-analysis. J Stomatol Oral Maxillofac Surg. 2023. 10.1016/j.jormas.2022.10.023. [DOI] [PubMed] [Google Scholar]
  • 18.Duan C, et al. Clinical performance of zirconium implants compared to titanium implants: a systematic review and meta-analysis of randomized controlled trials. PeerJ. 2023. 10.7717/peerj.15010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Bethke A, et al. Fracture resistance of zirconia oral implants in vitro: a systematic review and meta-analysis. Materials. 2020. 10.3390/ma13030562. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Haugen HJ, Chen H. Is there a better biomaterial for dental implants than titanium?—a review and meta-study analysis. J Funct Biomater. 2022. 10.3390/JFB13020046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Sicilia A, et al. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implant Res. 2008. 10.1111/j.1600-0501.2008.01544.x. [DOI] [PubMed] [Google Scholar]
  • 22.Morena D, et al. Comparative clinical behavior of zirconia versus titanium dental implants: a systematic review and meta-analysis of randomized controlled trials. J Clin Med. 2024;13:4488. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Fiorillo L, et al. Endosseous dental implant materials and clinical outcomes of different alloys: a systematic review. Materials. 2022. 10.3390/ma15051979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Rousseau N, et al. Local tissue effects and peri-implant bone healing induced by implant surface treatment: an in vivo study in the sheep. J Periodontal Res. 2021. 10.1111/jre.12878. [DOI] [PubMed] [Google Scholar]
  • 25.Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6: e1000097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Richardson WS, Wilson MC, Nishikawa J, Hayward RS. The well-built clinical question: a key to evidence-based decisions. ACP J Club. 1995;123:A12–3. [PubMed] [Google Scholar]
  • 27.Aromataris E, Fernandez R, Godfrey CM, Holly C, Khalil H, Tungpunkom P. Summarizing systematic reviews: methodological development, conduct and reporting of an umbrella review approach. Int J Evid Based Healthc 2015;13(3):132–40. 10.1097/XEB.0000000000000055. [DOI] [PubMed] [Google Scholar]
  • 28.Munn Z, Tufanaru C, Aromataris E. JBI’s systematic reviews. AJN Am J Nurs. 2014;114:49–54. [DOI] [PubMed] [Google Scholar]
  • 29.Li L, et al. AMSTAR 2 appraisal of systematic reviews and meta-analyses in the field of heart failure from high-impact journals. Syst Rev. 2022;11:147. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010. 10.1007/s10654-010-9491-z. [DOI] [PubMed] [Google Scholar]
  • 31.Attard L, et al. Mechanical factors implicated in zirconia implant fracture placed within the anterior region—a systematic review. Dent J. 2022. 10.3390/dj10020022. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Linkevicius T, Vaitelis J. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: A systematic review and meta-analysis. Clin Oral Implant Res. 2015. 10.1111/clr.12631. [DOI] [PubMed] [Google Scholar]
  • 33.Cao Y, Yu C, Wu Y, Li L, Li C. Long-term survival and peri-implant health of titanium implants with zirconia abutments: a systematic review and meta-analysis. J Prosthodont. 2019. 10.1111/jopr.13097. [DOI] [PubMed] [Google Scholar]
  • 34.Lorusso F, et al. Scientific trends in clinical research on zirconia dental implants: a bibliometric review. Materials. 2020. 10.3390/ma13235534. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Andreiotelli M, Wenz HJ, Kohal RJ. Are ceramic implants a viable alternative to titanium implants? A systematic literature review. Clin Oral Implant Res. 2009. 10.1111/j.1600-0501.2009.01785.x. [DOI] [PubMed] [Google Scholar]
  • 36.Buser D, Sennerby L, De Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000. 2017. 10.1111/prd.12185. [DOI] [PubMed] [Google Scholar]
  • 37.Brånemark PI, et al. Intra-osseous anchorage of dental prostheses: I. experimental studies. Scand J Plast Reconstr Surg Hand Surg. 1969. 10.3109/02844316909036699. [DOI] [PubMed] [Google Scholar]
  • 38.Schroeder A, Sutter F, Ledermann PD, Stich H. Current experience with the ITI double hollow cylinder implant type K. Internationales team für orale Implantologie. Schweiz Monatsschr Zahnmed. 1984;94:503–10. [PubMed] [Google Scholar]
  • 39.Ortega-Oller I, et al. The influence of implant diameter on its survival: a meta-analysis based on prospective clinical trials. J Periodontol. 2014. 10.1902/jop.2013.130043. [DOI] [PubMed] [Google Scholar]
  • 40.Özkurt Z, Kazazoǧlu E. Zirconia dental implants: a literature review. J Oral Implantol. 2011. 10.1563/AAID-JOI-D-09-00079. [DOI] [PubMed] [Google Scholar]
  • 41.De la Rosa M, Rodríguez A, Sierra K, Mendoza G, Chambrone L. Predictors of peri-implant bone loss during long-term maintenance of patients treated with 10-mm implants and single crown restorations. Int J Oral Maxillofac Implant. 2013. 10.11607/jomi.3066. [DOI] [PubMed] [Google Scholar]
  • 42.Staubli N, Walter C, Schmidt JC, Weiger R, Zitzmann NU. Excess cement and the risk of peri-implant disease—a systematic review. Clin Oral Implant Res. 2017. 10.1111/clr.12954. [DOI] [PubMed] [Google Scholar]
  • 43.Rodriguez AE, Monzavi M, Yokoyama CL, Nowzari H. Zirconia dental implants: a clinical and radiographic evaluation. J Esthet Restor Dentist. 2018. 10.1111/jerd.12414. [DOI] [PubMed] [Google Scholar]
  • 44.Koller M, et al. Two-piece zirconia versus titanium implants after 80 months: clinical outcomes from a prospective randomized pilot trial. Clin Oral Implants Res. 2020. 10.1111/clr.13576. [DOI] [PubMed] [Google Scholar]
  • 45.Hosseini M, Worsaae N, Gotfredsen K. A 5 year randomized controlled trial comparing zirconia-based versus metal-based implant-supported single-tooth restorations in the premolar region. Clin Oral Implant Res. 2022. 10.1111/clr.13960. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Raffa ML, Nguyen VH, Hernigou P, Flouzat-Lachaniette CH, Haiat G. Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio. J Orthop Res. 2021. 10.1002/jor.24840. [DOI] [PubMed] [Google Scholar]
  • 47.ElHoussiney AG, et al. Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis. Clin Cosmet Investig Dentist. 2018. 10.2147/CCIDE.S143910. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Beekmans D, Beekmans B, Cune M. Pink and white esthetics of a new zirconia implant: a 6 month to 8 year follow-up. Int J Periodontic Restor Dent. 2017. 10.11607/prd.2705. [DOI] [PubMed] [Google Scholar]
  • 49.Belser UC, et al. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4 year follow-up using pink and white esthetic scores. J Periodontol. 2009. 10.1902/jop.2009.080435. [DOI] [PubMed] [Google Scholar]
  • 50.van Brakel R, et al. The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues. Clin Oral Implant Res. 2011. 10.1111/j.1600-0501.2010.02082.x. [DOI] [PubMed] [Google Scholar]
  • 51.Nothdurft FP, et al. Differential behavior of fibroblasts and epithelial cells on structured implant abutment materials: a comparison of materials and surface topographies. Clin Implant Dent Relat Res. 2015. 10.1111/cid.12253. [DOI] [PubMed] [Google Scholar]
  • 52.Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004. 10.1902/jop.2004.75.2.292. [DOI] [PubMed] [Google Scholar]
  • 53.Rimondini L, Cerroni L, Carrassi A, Torricelli P. Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study. Int J Oral Maxillofac Implant. 2002;17:793–8. [PubMed] [Google Scholar]
  • 54.Tolentino L, et al. One-year follow-up of titanium/zirconium alloy X commercially pure titanium narrow-diameter implants placed in the molar region of the mandible: a randomized controlled trial. Clin Oral Implant Res. 2016. 10.1111/clr.12561. [DOI] [PubMed] [Google Scholar]
  • 55.Al-Nawas B, et al. A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period. Clin Implant Dent Relat Res. 2012. 10.1111/j.1708-8208.2010.00324.x. [DOI] [PubMed] [Google Scholar]
  • 56.Müller F, et al. Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: Five-year results from a double-blind, randomized controlled trial. BMC Oral Health. 2015. 10.1186/s12903-015-0107-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Ioannidis A, et al. Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3 year results of a randomized controlled clinical study. J Clin Periodontol. 2015. 10.1111/jcpe.12468. [DOI] [PubMed] [Google Scholar]
  • 58.Siddiqi A, Kieser JA, De Silva RK, Thomson WM, Duncan WJ. Soft and hard tissue response to zirconia versus titanium one-piece implants placed in alveolar and palatal sites: a randomized control trial. Clin Implant Dent Relat Res. 2015. 10.1111/cid.12159. [DOI] [PubMed] [Google Scholar]
  • 59.Cionca N, Hashim D, Mombelli A. Zirconia dental implants: where are we now, and where are we heading? Periodontol 2000. 2017. 10.1111/prd.12180. [DOI] [PubMed] [Google Scholar]
  • 60.Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implant Res. 2012. 10.1111/j.1600-0501.2012.02546.x. [DOI] [PubMed] [Google Scholar]
  • 61.Alfadda SA. Current evidence on dental implants outcomes in smokers and nonsmokers: A systematic review and meta-analysis. J Oral Implantol. 2018. 10.1563/aaid-joi-D-17-00313. [DOI] [PubMed] [Google Scholar]
  • 62.Luthra S, Sirana P, Pasricha N, Issar G, Singla N. Comparison of the effect of zirconia and titanium abutments on peri-implant hard and soft tissues. J Indian Prosthodont Soc. 2024. 10.4103/jips.jips_201_23. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Tang K, et al. The integration of peri-implant soft tissues around zirconia abutments: challenges and strategies. Bioact Mater. 2023. 10.1016/j.bioactmat.2023.04.009. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

No datasets were generated or analysed during the current study.


Articles from European Journal of Medical Research are provided here courtesy of BMC

RESOURCES