Significance
Research blending climate models with physiological data has projected that large geographical areas may soon experience heat stress exceeding limits for human thermoregulation. Modeled thermoregulatory limits were derived from laboratory research using thermal-step protocols. Despite the growing popularity of this technique, its principal assumption—that core temperature inflection during stepped increases in heat or humidity demarcates thermoregulatory upper limits—has not been validated. By exposing participants for 9 h to conditions just above or below the core temperature inflection point, we found that thermal-step protocols effectively identify the conditions above which thermoregulation is impossible. Our findings provide critical support for heat stress projections incorporating empirical tolerance limits. We also provide data characterizing physiological strain during prolonged, uncompensable heat exposure.
Keywords: heat wave, extreme heat, heat survivability, thermoregulatory compensability, critical environmental limits
Abstract
Recent projections suggest that large geographical areas will soon experience heat and humidity exceeding limits for human thermoregulation. The survivability limits modeled in that research were based on laboratory studies suggesting that humans cannot effectively thermoregulate in wet bulb temperatures (Twb) above 26 to 31 °C, values considerably lower than the widely publicized theoretical threshold of 35 °C. The newly proposed empirical limits were derived from the Twb corresponding to the core temperature inflection point in participants exposed to stepped increases in air temperature or relative humidity in a climate-controlled chamber. Despite the increasing use of these thermal-step protocols, their validity has not been established. We used a humidity-step protocol to estimate the Twb threshold for core temperature inflection in 12 volunteers. To determine whether this threshold truly demarcates the Twb above which thermoregulation is impossible, each participant was subsequently exposed to Twb above (~33.7 °C, Tabove) and below (~30.9 °C, Tbelow) their respective inflection point (~32.3 °C, Twb) for up to 9 h (in random order). Core temperature rose continuously in Tabove. It was projected that core temperatures associated with heat stroke (40.2 °C) would occur within 10 h. While Tbelow was also uncompensable, the core temperature rate of rise was considerably lower than in Tabove such that it would take >24 h to reach 40.2 °C. Our study supports thermal-step protocols as an effective technique for evaluating survivability limits for heat exposure and provides a direct assessment of the limits of human thermoregulation.
There is mounting concern that climate change may soon render large areas of the planet uninhabitable (1). Recent research suggests that, even at 1.5 °C of global average warming, certain regions (primarily in the Global South) will occasionally see conditions so hot and humid that they breach the limits of human survivability (2, 3). Growing recognition of the thinning safety margin between experienced heat extremes and the limits of human heat tolerance has motivated the incorporation of data on thermoregulation and other physiological impacts into weather and climate models (2–6). Coming years will see such models contributing to the development of health-centric warming projections and adaptation efforts for protecting at-risk populations.
Tolerating prolonged exposures to high temperatures is primarily dependent on the ability of the thermoregulatory system to maintain body core temperature within the relatively narrow limits required for normal physiological function (7). In heat-exposed persons, heat gain from the environment and metabolism initially exceeds the rate of skin-environment heat loss, which causes heat to be stored within the body and its temperature to rise (7, 8). Elevated body temperatures trigger autonomically mediated elevations in skin blood flow and sweating to facilitate heat dissipation via dry (radiation and convection) and evaporative mechanisms. Sweating and skin blood flow increase until the rate of heat gain is compensated by heat loss and body temperature stabilizes. If, however, the achievable rate of heat dissipation is insufficient to offset heat gain, conditions are uncompensable and body core temperature rises unchecked (7, 8). How long an exposed individual can survive uncompensable heat exposure is determined by the magnitude of the disparity between heat gain and the maximal achievable rate of heat loss (Definitions in the Materials and Methods provides a summary of different classifications of uncompensable heat stress).
In 2010, Sherwood and Huber (9) placed the absolute environmental upper limit for thermoregulatory compensability at a wet bulb temperature (Twb) of 35 °C. They reasoned that, above this threshold, the physical laws governing heat and moisture transfer preclude sufficient skin-environment heat loss to offset basal metabolic heat production and, as a consequence, even resting persons would develop heat stroke within 6 h of sustained exposure (9). The 35 °C Twb limit has since been widely publicized in both the academic literature and news media (10–13). However, in 2023, Vecellio et al. (2) argued that the true limit for thermoregulatory compensability likely occurs at 26 to 31 °C Twb. In contrast to the theoretical 35 °C Twb threshold, Vecellio et al. (2) based their assessments on estimated empirical limits derived from laboratory studies (14, 15). Under current planetary warming, Twb exceeding empirical limits will be experienced in large areas of the globe by 2100, mostly in the Global South (2). Incorporating these limits into climate modeling resulted in an ~4,100-fold greater elevation in projected uncompensable heat stress with 2 °C global warming compared to the 35 °C Twb threshold (~86,000 vs. ~21 annual person-hours) (2). Empirical compensability limits have also been used in modeling by Powis et al. (3), who estimated an increasing frequency of days exceeding thermoregulatory upper limits globally, with some areas in the Global South experiencing ≥20 d of uncompensable heat annually under 2 to 3.5 °C global warming. More recently, Fan and McColl (6) used empirical compensability limits to validate their energy balance model projecting increasing uncompensable heat stress for farmers and other outdoor workers.
The empirical thermoregulatory compensability limits incorporated into recent climate modeling (2, 3, 6) were identified in the Penn State Human Environmental Age Thresholds (PSU HEAT) project, an extensive and ongoing series of laboratory experiments employing thermal-step protocols (14–16). In thermal-step protocols, resting or lightly exercising participants are exposed to rapidly stepped increases in air temperature (Ta) or relative humidity (rh) in a climate-controlled chamber [e.g., 2% rh every 5 min at 39 °C Ta (17)]. Core temperature is initially stable (or rises slightly) but undergoes an abrupt and rapid increase as exposure becomes more severe. The Twb (or other index of heat stress) at this inflection point is taken as the individual limit of thermoregulatory compensability. The key advantage of thermal-step protocols is that their short duration (typically 1 to 2 h) facilitates assessments of large numbers of participants through a wide range of environmental conditions. Because of this, there is a rapidly growing body of literature in which these protocols have been used to estimate heat tolerance limits and how they are influenced by ambient conditions (e.g., Ta-rh combinations) (14–16), personal characteristics (e.g., age, sex, morphology, fitness) (17–22) and heat-related interventions (e.g., cooling garments, electric fan use, acclimatization, sunscreen) (23–28).
The ability of thermal-step protocols to identify the limits of thermoregulation and prolonged heat tolerance is dependent on the assumption that core temperature inflection corresponds to the conditions above which thermoregulatory compensation is impossible. However, the validity of this assumption has not been clearly established. In an early paper, Belding and Kamon (29) reported that “[rectal temperature] equilibrium was delayed [and] sometimes was not reached even after the full 2 h” in males exercising in conditions slightly above (~0.3 °C Twb) their predicted compensability threshold. That thermal equilibrium is delayed but may eventually be achieved in conditions above the core temperature inflection point is consistent with earlier interpretations by Lind (30), whose work motivated the development of thermal-step protocols (29, 31). Lind (30) observed that whole-body sweat rate at the point of rectal temperature inflection (termed the limits of the prescriptive zone) is far below the physiological maximum and instead suggested that the increase in core temperature in hotter conditions serves to maintain an internal thermal gradient for sufficient core-to-skin heat transfer. Core temperature increasing but ultimately stabilizing in conditions above the inflection point is also supported by observations in other mammalian species (32). Moreover, we recently demonstrated that, in compensable conditions, equilibrium core temperature is proportional to air temperature (33) but is not achieved until 4 to 6 h into exposure (34). These findings suggest that the sustained rise in core temperature observed above the inflection point during stepped increases in Ta or rh (15) may be due to the short step duration (~5 to 10 min), rather than compensability limits being exceeded. That is, the rapid increases in Twb employed in thermal-step protocols may not allow for thermal equilibrium, even if conditions are compensable.
Empirical heat tolerance limits derived using thermal-step protocols are being incorporated into climate modeling (2, 3, 6), which may have widespread implications for climate adaptation. There is, however, a critical lack of data supporting the principal assumption underpinning this technique. In this prospectively registered study (ClinicalTrials.gov identifier: NCT05963529) we determined the validity of a thermal-step protocol for identifying the upper limit of thermoregulatory compensability. Specifically, we evaluated whether the core temperature inflection point during stepped increases in ambient rh truly demarcates the environmental conditions above which thermoregulation is impossible by characterizing rectal temperature responses in 12 volunteers (Table 1) exposed to conditions just above and just below this threshold for up to 9 h (Fig. 1). Not only did this design allow us to validate the central assumption of thermal-step protocols, but the prolonged exposure also permitted direct characterization of human physiological responses to severe heat stress.
Table 1.
Participant characteristics
| All participants (n = 12) | |
|---|---|
| Age, years | 28 (25 to 32) |
| Sex | |
| Females | 3 (25%) |
| Males | 9 (75%) |
| Height, cm | 179 (167 to 183) |
| Body mass, kg | 80.2 (73.9 to 91.2) |
| Body mass index, kg/m2 | 26.2 (22.9 to 30.4) |
| Body surface area, m2 | 2.0 (1.8 to 2.2) |
| Body fat percentage, % | 20.8 (17.8 to 27.4) |
| Peak aerobic power (V̇O2peak), mL/min/kg | 50.9 (41.8 to 54.5) |
| Systolic blood pressure, mm Hg | 119 (112 to 121) |
| Diastolic blood pressure, mm Hg | 79 (76 to 81) |
Values are median and IQR or no. participants (%). Body mass index calculated as weight in kilograms divided by the square of height in meters, body surface area calculated according to the Du Bois equation (35), body fat percentage estimated via bioelectric impedance analysis, peak aerobic power measured via automated metabolic gas analysis during incremental exercise test to volitional fatigue on a treadmill ergometer (36).
Fig. 1.
Example of the (A) humidity-step protocol for estimating the wet bulb temperature (Twb) limit for thermoregulatory compensability and (B) subsequent exposures to Twb above and below the empirically estimated limit for a single participant. rh, relative humidity.
Results
Identifying Critical Wet Bulb Limits for Thermal Compensation.
Participants first completed a resting humidity-step protocol to estimate their environmental limits for compensability (Fig. 1A). Participants were seated seminude in a climate-controlled chamber regulated to 42 °C air temperature (Ta) with 28% rh (26.8 °C Twb). After a 70-min equilibrium period, rh was increased 3% every 10 min to 70% (36.8 °C Twb). The inflection point for esophageal temperature (and other physiological variables: rectal temperature, skin temperature, and heart rate) was later determined by a blinded analyst (described in Materials and Methods). The limit for thermal compensation was taken as the esophageal temperature inflection, which occurred at a median [interquartile range (IQR)] of 32.3 (31.9 to 32.6) °C Twb (42 °C Ta with ~51% rh).
Core Temperature Inflection as an Estimate of Thermoregulatory Compensability Limits.
On return visits to the laboratory, participants were exposed to conditions ~1.3 °C Twb above (Tabove) and below (Tbelow) their individual Twb limit estimated in the step protocol (Fig. 1B). The Twb was 33.7 (33.4 to 33.9) °C in Tabove and 30.9 (30.6 to 31.1) °C in Tbelow (42 °C Ta with ~57% rh and ~45% rh, respectively). Participants also completed a mild control condition (17.7 °C Twb; 28 °C Ta with 35% rh). The order of conditions was randomized. Exposure continued until 9 h elapsed, rectal temperature surpassed 39.2 °C, or the participant experienced adverse heat-related symptoms and/or requested to withdraw.
Rectal temperature responses for each participant are shown in Fig. 2A. The projected rate of rise in rectal temperature was positive at end-exposure in both Tabove and Tbelow but was statistically significantly greater in Tabove (Fig. 2B). Eight participants did not complete Tabove due to rectal temperature exceeding 39.2 °C and/or experiencing adverse heat-related symptoms (e.g., nausea, dizziness). One participant withdrew from Tbelow due to headache (rectal temperature of 38.5 °C). A log rank test comparing Kaplan–Meier curves demonstrated a higher probability of early exposure termination in Tabove compared to Tbelow (Fig. 2C). No participants withdrew from the control condition. Bootstrap analysis indicated it would take an average of 9.8 [bootstrap 95% CI: 8.3, 11.6] hours of sustained exposure for rectal temperature to exceed 40.2 °C, an approximate threshold for heat stroke (7, 15), in Tabove and 35.2 [22.0, 61.0] hours in Tbelow (Fig. 2D).
Fig. 2.

Individual rectal temperature traces (A) and projected end-exposure rectal temperature rate of rise (B) during the above (Tabove) and below (Tbelow) wet bulb limit conditions and control. Summary for each condition is mean with SD (light bars) and 95% CIs (dark bars). Between-condition differences are mean [95% CI]. (C) Kaplan–Meier curves showing participant withdrawal in Tabove and Tbelow. (D) Distribution of bootstrap estimates for the average projected time to 0.2 °C rectal temperature, an approximate threshold for heat stroke (15, 37). Summary data are bootstrap mean [95% CI].
Analyses of rectal temperature responses in Fig. 2 indicate that thermal compensation was not achieved in Tabove or Tbelow (though the rate of increase and risk of heat stroke was elevated considerably in the former). This interpretation is consistent with and supported by the rate of change in mean skin temperature and heart rate, which were also positive at end-exposure in Tabove and Tbelow but not control (Fig. 3 A and B).
Fig. 3.

Projected end-exposure rate of increase in mean skin temperature (A) and heart rate (B) during the above (Tabove) and below (Tbelow) wet bulb limit conditions and control. Summary for each condition is mean with SD (light bars) and 95% CIs (dark bars). Between-condition differences are mean [95% CI]. bpm, beats per min.
Quantifying the Magnitude of Physiological Heat Strain.
To provide more information on the magnitude of thermal and cardiovascular strain experienced, we compared body temperature and heart rate responses as well as whole-body sweat rate and fluid loss between exposure conditions. Measured or projected rectal temperature, mean skin temperature, and heart rate, following 9 h of exposure were statistically significantly elevated in Tabove compared to Tbelow, and in Tbelow compared to control (Fig. 4 A–C). Sweat rate was elevated in Tabove compared to Tbelow and in both these conditions compared to control (Fig. 4D). Despite elevated sweat rates, provided fluid was sufficient at keeping nude mass loss below 2% pre-exposure body mass [median (IQR): 0.9 (0.6 to 1.3)% and 1.0 (0.7 to 1.3)% body mass loss, in Tabove and Tbelow, respectively], the threshold at which alterations in thermoregulatory function become apparent (38).
Fig. 4.

Rectal temperature (A), mean skin temperature (B), heart rate (C), and whole-body sweat rate (D) responses during the above (Tabove) and below (Tbelow) wet bulb limit conditions and control. For panels (A–C) data represent those measured at end-exposure (circles) or projected from rate of change at the point of exposure termination (diamonds). For panel (D), sweat rates were calculated from changes in body mass, fluid consumption, and urination between hours 4 and 6 (diamonds still denote participants terminating exposure early). Summary for each condition is mean with SD (light bars) and 95% CI (dark bars). Between-condition differences are mean [95% CI]. bpm, beats per min.
Discussion and Implications
A humidity-step protocol effectively identified the Twb above which thermoregulation is not possible in humans. In conditions hotter than the estimated Twb limit for thermoregulatory compensability, the body temperatures and heart rates of exposed volunteers rose rapidly and unabated; it was projected that core temperatures associated with heat stroke (40.2 °C) would occur within 10 h of sustained exposure (Figs. 2 and 3). Our study validates the central assumption of thermal-step protocols. In doing so, we also provide critical support for recent research coupling empirically estimated compensability limits and climate modeling to project how climate change will impact global exposures to uncompensable heat stress (2, 3). Not only is the planet getting hotter and more humid, the safety margin between experienced heat extremes and the limits of human heat tolerance is thinner than previously thought (1).
The upper limit for thermoregulatory compensability occurred at a Twb of ~32 °C (42 °C Ta with ~51% rh) in our participants. At this same air temperature, the limit estimated in the PSU HEAT study under the minimal physical activity condition was 27 °C Twb (42 °C Ta with ~40% rh) (14). The discrepancy between these values likely stems from our participants being exposed at rest whereas the PSU HEAT participants performed loadless cycling, resulting in a higher rate of metabolic heat generation. Previous studies by Wolf et al. (20) and Ravanelli et al. (24) have produced compensability limits in unacclimated, resting individuals consistent with our findings (31 to 34 °C Twb). Our data also fall within the range of temperatures in which compensability is not possible for resting persons but body temperatures associated with heat stroke would take more than 6 h to develop, as estimated with the biophysical model developed by Vanos et al. (4). Rather than estimating survivability limits empirically like thermal-step protocols, biophysical models employ mathematical equations describing body-environment heat exchange with key inputs derived from laboratory studies. These rational models allow for rapid evaluation of how variations in ambient conditions or other factors (e.g., personal characteristics, heat interventions) modify upper limits for thermoregulation. However, model outputs are highly sensitive to the choice of physiological inputs, particularly those defining the behavior of the sweating response (e.g., sweating efficiency, maximum sweat rate) (39). Based on our finding that thermal-step protocols provide a valid estimation of the upper limits of human thermoregulation, empirical compensability limits should be employed in climate modeling or other applications whenever available.
While exposure to Twb above the core temperature inflection point was uncompensable, our data are less clear as to whether conditions were compensable just below this threshold. Body temperatures and heart rate increased progressively in Tbelow. However, the rate of rise in this condition was considerably slower than in Tabove such that it would require >24 h of sustained exposure for heat stroke to develop (Figs. 2 and 3). It is therefore possible that thermal-step protocols slightly overestimate the limits of thermoregulatory compensability. A potential explanation is the short step length employed (5 to 10 min) (14–16). Heat gained at the skin is transferred to the body core through convective exchange via the blood and conduction between adjacent tissues (40, 41). Internal heat flux is not instantaneous, and in some circumstances, changes in environmental heat stress are not fully reflected in the deep body tissues until after a considerable length of time. For example, we have shown that it can take 4 to 6 h for stable core temperature to be reestablished in resting persons moved from thermoneutral to simulated heat wave conditions (33, 34). A delay of this magnitude is unlikely to be relevant for thermal-step protocols given the more gradual increases in ambient heat stress. Many protocols also incorporate physical activity (14–16), increasing heat generation and blood flow, thereby speeding internal heat distribution (8, 40).
Our findings support thermal-step protocols as an effective method for identifying the environmental conditions above which heat stroke develops rapidly. Estimated empirical limits from research employing thermal-step protocols should be used to further expand climate modeling to a wider range of populations, as research in this area has only considered limits estimated in healthy young adults (2, 3). Estimated compensability limits for older adults, who are at elevated risk of heat stroke and other heat-related injuries due to age-related declines in thermoregulatory function (37), are available (16, 17) but have yet to be incorporated into climate models. Work is also needed to determine compensability limits in other at-risk groups like persons with health conditions increasing physiological strain and heat vulnerability (e.g., diabetes) (37) and in persons in the Global South. Although the most severe rises in humid heat are expected to occur in South Asia and Africa (2), residents are likely more acclimatized to heat compared to individuals from the Global North, where most studies on empirical compensability limits (and thermal physiology more generally) have been conducted.
Future research and modeling should also consider that, even in compensable conditions, prolonged heat exposure can increase physiological strain and the risk of numerous adverse health effects (7, 42). It is often assumed that core temperature remains at near basal levels until conditions become uncompensable (4, 5). This assumption may stem, at least in part, from the typical development of hyperthermia observed during thermal-step protocols whereby core temperature is initially stable until the compensability limit is exceeded (14–16). However, potentially concerning physiological heat strain can be experienced in conditions below core temperature inflection. Even though it was projected that it would take >24 h of sustained exposure for heat stroke to develop in Tbelow (~30.9 °C Twb), core temperature and heart rate were still elevated 0.9 [0.5, 1.2] °C and 41 [29, 53] beats per min from the control condition after 9 h of exposure (Fig. 4). Moreover, clinically meaningful elevations in thermal and cardiovascular strain leading to reduced autonomic function and adverse symptoms have been observed in older adults during prolonged but compensable exposure to Twb as low as 22 to 26 °C (33, 34).
It is important to recognize that elevations in physiological strain are required to support thermoregulation. If heat stress is compensable, thermoregulatory adjustments will reestablish a balance between heat gain and heat loss. However, the new steady-state thermal equilibrium must operate at body temperatures above basal levels to ensure sufficient skin-environment heat transfer and sweat rate (which is activated by elevated body temperatures in a negative feedback loop) (7, 30). An increase in heart rate is also necessary to offset reductions in peripheral resistance (secondary to cutaneous vasodilation) and support maintenance of arterial blood pressure and organ perfusion (37). This strain, while less severe than that occurring during uncompensable heat stress, may still precipitate acute injury (7). Temperature-related mortality begins to rise well before conditions approach limits of thermal tolerance (43) and only 9 to 37% of heat wave mortality results from heat stroke (44). Most heat-related deaths are instead due to cardiovascular and renal injury (7, 37). While these indirect and cascading effects are harder to quantify, developing robust climate-health models requires we consider that whether empirical (2, 3), rational (4–6), or theoretical (9), estimated limits for thermoregulatory compensability only capture the point at which conditions become too severe for prolonged tolerance. The risk of injury may still be significant below this point, especially for heat-vulnerable groups (7).
The primary limitation of our study was that due to the time and resource-intensive nature of conducting daylong exposures in climate-controlled chambers, we were only able to directly validate the central assumption of thermal-step protocols under a single Ta-rh combination. Relatedly, we were not able to evaluate whether this assumption held in heat-vulnerable or regularly exposed groups (e.g., older adults) (16, 17) or more heat-acclimatized persons (e.g., those residing in the Global South), or if it was sensitive to variation in participant characteristics or the use of heat-interventions (e.g., electric fans, cooling garments) (17–28). It should be considered, however, that all that is required for our findings to generalize to different ambient conditions and populations is that the relationship between core temperature inflection and the limit of thermoregulatory compensability is not altered in those contexts—a point that is also inherently assumed in other research using thermal-step protocols. Some support for this notion was provided by Cottle et al. (45) who showed high day-to-day reliability of thermal-step protocols across a wide range of ambient conditions and that the same core temperature inflection point was identified regardless of whether air temperature or humidity was ramped (with the other variable held constant). Regardless, the validity of thermal-step protocols for estimating thermoregulatory compensability limits should be confirmed under a greater range of ambient conditions and with more diverse participants, particularly individuals residing in the Global South, where the most extreme increases in humid-heat are expected (2, 3). Not only could such research be used to refine climate health projections, but direct measurements of physiological responses (and their associated uncertainty) in uncompensable conditions could be used to refine inputs for “biophysical” models (39).
By exposing participants to conditions just above and just below the thermal-step protocol-estimated core temperature inflection point, we demonstrated that this technique accurately identified the limits of human thermoregulation. Our findings support thermal-step protocols as an effective and, given their short duration, efficient method for evaluating the limits of human thermoregulation. Expanding estimated tolerance limits to a greater number of populations and contexts and subsequent incorporation into climate models is needed to further the development of health-centric warming projections and adaptation strategies for protecting heat-vulnerable groups.
Materials and Methods
Definitions.
There are several different terms used in the literature to describe and classify the severity of heat exposure. “Thermoregulation” refers to the physiological processes through which body temperature is regulated. During heat stress, the thermoregulatory system augments heat loss by increasing skin blood flow and sweating in a bid to offset the rate of heat gained from metabolism and the environment (if air temperature exceeds skin temperature). “Thermoregulatory compensation” occurs when the generated rate of heat loss is sufficient to offset the rate of heat gain. “Compensable heat stress” refers to conditions in which the rate of heat gain can be balanced by the rate of heat loss (i.e., thermoregulatory compensation is possible). “Uncompensable heat stress” conditions are those in which the required rate of heat loss exceeds that allowable. Note that uncompensable heat stress may result from increases in heat gain (e.g., heat exposure or physical activity) or reductions in skin-environment heat transfer (e.g., increased humidity, insulated/impermeable clothing, age-related reductions in sweating) (7). “Environmental upper limits for thermoregulatory compensability” therefore refer to the combinations of air temperature and humidity (and other variables, e.g., sun exposure, airflow) demarcating the border between compensable and uncompensable heat stress. Multiple definitions and variations of compensability limits have been developed (mostly based on severity). For example, Sherwood and Huber (9) used the term “adaptability limit” to describe the physically bound upper limit above which skin-environment heat exchange via sweat evaporation is not possible. More recently, Vanos et al. (4) used the term “survivability limit” to describe uncompensable conditions so severe that body temperatures associated with heat stroke would be reached within 6 h. They also coined the term “livability limit” to define conditions above which thermoregulatory compensation is not possible when performing common tasks associated with daily living (ranging from desk work to moving heavy objects) (4). Throughout this paper, we use the more general terms “limits for thermoregulatory compensability” or, equivalently, “limits for thermoregulation.”
Ethical Approval.
This study was approved by the University of Ottawa Health Sciences and Science Research Ethics Board (H-03-21-6731) and was prospectively registered (ClinicalTrials.gov identifier: NCT05963529). Testing was conducted at the Human and Environmental Physiology Research Unit of the University of Ottawa (ON, Canada) from July to September, 2023 (inclusive). Ottawa has a Warm Summer Continental Climate (Köppen Climate Subtype Dfb).
Participants and Sample Size Determination.
Prospective participants were eligible if they were nonsmoking, spoke English or French, and were able to provide informed consent. Exclusion criteria included physical restriction or current use of medications judged by the participant or investigators to make participation inadvisable. For the female participants, we did not restrict testing to a specific menstrual cycle or pill-taking phase if taking oral hormonal contraceptives.
An a priori power analysis indicated that a sample size of 12 was sufficient to detect a >0.05 °C/h between-condition difference in the rate of core temperature rise with 89% power (α = 0.05) above the estimated wet bulb limit for thermal compensation (described below) compared to the below limit and control conditions (rate of change in the latter two conditions was assumed to be identical). The modeled SD for the rate of core temperature change, 0.06 °C/h, was estimated from our recent study in which young adults were exposed to 40 °C Ta with 9% rh for 9 h (34, 46). The within-subject correlation was assumed to be 0.6. The “Superpower” R package was used for the sample size simulation (2,000 iterations) (47).
Experimental Procedures.
Enrolled participants completed one preliminary and four experimental sessions. Experimental sessions included a humidity-step protocol followed by three fixed-condition exposures (Fig. 1). The humidity-step was always completed first. The order of the three fixed-condition trials was randomized according to a key produced in Microsoft® Excel®. All experimental sessions were separated by at least 4 d. Participants were instructed to avoid strenuous physical activity and alcohol for 24 h and to eat a light meal 2 h before each laboratory session. They were also asked to consume a minimum of 500 mL of water the night before and morning of each session to ensure adequate hydration. A urine sample collected upon arrival to the laboratory was used to confirm adequate hydration [urine specific gravity <1.025; Reichert TS 400 total solids refractometer, Reichert (48)]. Minimal clothing was worn for all sessions (sandals and shorts; women also wore a sports bra or light shirt).
Preliminary Screening.
During the preliminary session, participants were familiarized with all procedures and measurements and completed the Canadian Society for Exercise Physiology Get Active Questionnaire and the American Heart Association Pre-Participation Screening Questionnaire to assess their eligibility to participate (described above). After completing the forms, arterial blood pressure was taken via automated oscillometry of the brachial artery. Descriptive anthropomorphic data were then collected. Body height and mass were determined via a stadiometer (model 2391, Detecto) and a digital weighing terminal (model CBU150X, Mettler Toledo Inc.). These measurements were later used to calculate body mass index and body surface area (35). Body fat percentage was estimated with bioelectrical impedance analysis (MC-780U PLUS, Tanita). Peak aerobic power was determined via automated metabolic gas analysis (Medgraphics Ultima, MGC Diagnostics) during an incremental exercise test to volitional fatigue on a treadmill ergometer (36).
Humidity-Step Protocol.
The purpose of the humidity-step protocol was to estimate the Twb limit for thermoregulatory compensation for each participant (i.e., the hottest conditions in which the rate of heat gain from metabolism can be compensated for by heat loss from the skin such that heat balance and stable core temperature is achieved). This protocol was based on the PSU HEAT project and similar studies in which the environmental limits of compensability were estimated in resting participants (10–13, 23, 24). Participants completed the humidity-step protocol in groups of 2 to 3. All humidity-step protocols commenced between 11:00 and 14:00. Upon arrival at the laboratory, participants changed into trial attire, provided a urine sample for evaluation of hydration status (described above) and inserted a general-purpose thermocouple temperature probe for the continuous measurement of rectal temperature. Following a measurement of nude body mass, participants were instrumented with a heart rate monitor and 4 digital skin temperature sensors on the chest, bicep, thigh, and calf of the left side of the body (see Outcome measurement and data processing below for more details).
Participants then entered a climate-controlled chamber regulated to 42 °C and 28% rh and were seated (slightly reclined) on a chair made of breathable fabric (Ergo High Back Camp Chair, Bass Pro Shops). Participants rested under these conditions for a 60-min equilibrium period. During this period, final instrumentation was completed, including insertion of a general-purpose thermocouple probe by a laboratory-technician for the measurement of esophageal temperature. Following the equilibrium period, 10 min of data was collected at 42 °C and 28% rh. Humidity was then increased 3% every 10 min until rh in the chamber reached 70% (Table 2). No fluid was provided throughout the exposure (except for during esophageal probe insertion, described below). Participants were provided with water and/or a commercial sports drink before leaving the laboratory. Esophageal temperature and chamber ambient conditions were extracted and used to estimate the Twb limit for thermoregulatory compensability for each participant (see Outcome measurements and data processing for more details).
Table 2.
Environmental conditions for the humidity-step protocol
| Stage timing | Humidity and vapor pressure | Temperatures (°C) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Stage | Start | End | rh % | P kPa | P mm Hg | Air (Ta) | Dewpoint (Tdp) | Wet bulb (Twb) | WBGT |
| 0 | 00:00 | 01:10 | 28 | 2.30 | 17.2 | 42.0 | 19.7 | 26.8 | 31.4 |
| 1 | 01:10 | 01:20 | 31 | 2.54 | 19.1 | 42.0 | 21.4 | 27.7 | 32.0 |
| 2 | 01:20 | 01:30 | 34 | 2.79 | 20.9 | 42.0 | 22.9 | 28.6 | 32.6 |
| 3 | 01:30 | 01:40 | 37 | 3.03 | 22.8 | 42.0 | 24.3 | 29.4 | 33.2 |
| 4 | 01:40 | 01:50 | 40 | 3.28 | 24.6 | 42.0 | 25.6 | 30.2 | 33.7 |
| 5 | 01:50 | 02:00 | 43 | 3.53 | 26.4 | 42.0 | 26.8 | 31.0 | 34.3 |
| 6 | 02:00 | 02:10 | 46 | 3.77 | 28.3 | 42.0 | 28.0 | 31.7 | 34.8 |
| 7 | 02:10 | 02:20 | 49 | 4.02 | 30.1 | 42.0 | 29.1 | 32.4 | 35.3 |
| 8 | 02:20 | 02:30 | 52 | 4.26 | 32.0 | 42.0 | 30.1 | 33.1 | 35.7 |
| 9 | 02:30 | 02:40 | 55 | 4.51 | 33.8 | 42.0 | 31.1 | 33.7 | 36.2 |
| 10 | 02:40 | 02:50 | 58 | 4.76 | 35.7 | 42.0 | 32.0 | 34.4 | 36.7 |
| 11 | 02:50 | 03:00 | 61 | 5.00 | 37.5 | 42.0 | 32.9 | 35.0 | 37.1 |
| 12 | 03:00 | 03:10 | 64 | 5.25 | 39.4 | 42.0 | 33.8 | 35.6 | 37.5 |
| 13 | 03:10 | 03:20 | 67 | 5.49 | 41.2 | 42.0 | 34.6 | 36.2 | 37.9 |
| 14 | 03:20 | 03:30 | 70 | 5.74 | 43.1 | 42.0 | 35.4 | 36.8 | 38.3 |
rh, relative humidity; P, pressure; WBGT, wet bulb globe temperature.
Fixed-Condition Exposures.
On three separate randomized days following the humidity-step protocol, participants completed “fixed-condition” exposures. The purpose of these exposures was to evaluate and compare the rate of change in core temperature in conditions above and below each participant’s estimated environmental upper limit for thermoregulatory compensability, which was taken as the 5-min average Twb immediately prior to the esophageal temperature inflection point during the humidity-step protocol (14, 15, 23, 24). Participants completed these exposures in groups of 3 determined based on their inflection point in the humidity-step protocol. For example, the 3 participants whose esophageal temperature inflected at the lowest rh completed their fixed-condition exposures together, as did those with the highest inflection points and so on. The three conditions were as follows: 1) 42 °C with rh >5% above the estimated compensability limit (Tabove); 2) 42 °C with rh >5% below the estimated compensability limit (Tbelow); and 3) 28 °C with 35% rh (control). Determination of the exact rh for Tabove and Tbelow is described in Outcome measurements and data processing. The control condition was included to account for any natural fluctuations in core temperature (e.g., due to circadian rhythm). Ambient conditions for the control were chosen to lie within the thermoneutral zone for seminude individuals (49) and are also consistent with the range of ambient conditions for comfortable mean skin temperature (50, 51).
All fixed-condition exposures commenced between 08:00 and 09:00. Upon arrival at the laboratory, participants changed into trial attire, provided a urine sample for evaluation of hydration status (described above) and inserted a rectal thermocouple. Following a measurement of nude body mass, participants were instrumented with a heart rate monitor and 4 digital skin temperature sensors on the chest, bicep, thigh, and calf of the left side of the body (see Outcome measurements and data processing).
Participants then entered the climate chamber and were seated (slightly reclined) on a chair made of breathable fabric (Ergo High Back Camp Chair, Bass Pro Shops), where they rested for up to 9 h. For Tabove and Tbelow, the chamber was initially regulated to 42 °C and 28% rh. Participants rested under these conditions for a 60 min equilibrium period. Following an additional 10 min at 42 °C and 28% rh, rh was increased in 3% increments until the target humidity for that group/condition was reached. Humidity was then held at this level for the remainder of the 9 h. The control exposure was conducted similarly to Tabove and Tbelow except the chamber was kept at 28 °C and 35% rh for the entire exposure period.
For the first 6-h of the fixed-condition exposures, participants were provided 35 °C tap water in Tabove and Tbelow and room temperature water in the control condition. Participants were instructed to drink to thirst, with the goal of maintaining body mass near pre-exposure levels. To this end, body mass was measured every 2 h and participants were encouraged (by the investigators) to drink more if required. Participants were also provided with a standardized lunch (2× Cliff Bars®, ~500 kcal) between hours 2.5 and 3.5 of exposure. At the 6th hour of exposure, participants consumed a volume of water equivalent to 1.5 times their estimated hourly sweat rate over the preceding 2 h. Thereafter, an esophageal temperature probe was inserted while participants sipped additional water through a straw. At this point, water consumption ceased until the end of exposure to ensure accurate and stable esophageal temperature measurements.
For all conditions, participants remained in the climate-controlled chamber until rectal temperature surpassed 39.2 °C, the participant experienced adverse heat-related symptoms, requested to withdraw, or 9 h elapsed. Participants were provided with water and/or a commercial sports drink before leaving the laboratory.
Outcome Measurements and Data Processing.
Esophageal and rectal temperatures were measured using general-purpose thermocouple temperature probes (Mon-a-therm General Purpose Temperature Probe, Mallinckrodt Medical Inc.). The rectal probe was situated ~12 cm past the anal sphincter. Core temperature data were collected at a sampling frequency of 1 kHz using a data acquisition module (Power Lab, model PL3516, ADInstruments) and simultaneously displayed and recorded on a desktop computer using LabChart 8 Pro (ADInstruments). Data were downsampled to a 15 s sampling interval prior to analysis. Skin temperature was assessed every min using digital temperature sensors (DS1922L Thermochron, OnSolution Pty Ltd) affixed to four body regions using double-sided adhesives and medical tape. Mean skin temperature was calculated according to the weightings: 30% chest, 30% bicep, 20% thigh, and 20% calf (52). Heart rate was recorded at 1-s intervals using a Polar M400 monitor (Polar Electro Oy, Finland).
Esophageal, rectal, and mean skin temperatures and heart rate data from the humidity-step protocol were converted to min averages and exported as a series of figures (four per participant). Similar to previous reports (14, 15, 20), the inflection point for each variable was identified visually by manually plotting 2 lines, one starting 20 to 40 min prior to the approximate inflection point and the other starting 20 to 40 min after, with the point of intersection denoting the inflection point. The analyst was blinded to participant id, ambient humidity, and the physiological variable under analysis. This was achieved by removing the y-axis title and text from the figures and normalizing the range of each variable. The x-axis showing exposure time was also arbitrarily shifted so the analyst could not determine the inflection point based on the exposure timing.
Ambient rh in the 5 min preceding the inflection of esophageal temperature was taken as the limit for thermoregulatory compensability and used to determine the target humidity (and wet bulb temperature) for Tabove and Tbelow. The esophageal temperature inflection point was chosen over that of rectal temperature given the former responds more rapidly to changes in heat stress (34, 40).
Using the reliability data provided by Cottle et al. (45), we estimated the SE of the measurement of core (rectal) temperature inflection using the “SimplyAgree” package for R (53). From the estimated SE of the measurement, we calculated the individual minimal detectable difference using previously described equations (54, 55):
where MDD is the meaningful detectable difference (at the 95% confidence level), and SEM is the SE of the measurement (both in °C Twb).
Conditions for Tabove and Tbelow were then calculated as the Twb at esophageal temperature inflection ± the MDD (1.3 °C), converted to rh at 42 °C Ta. This ensured that the fixed-condition exposures for each participant were outside the measurement error associated with the humidity-step protocol. Since participants completed the fixed-condition exposures in groups of 3, the target rh for Tabove was set to the value (estimated wet bulb limit + 1.3 °C) for the participant with the highest inflection point among the group while the target for Tbelow was set to the value for the participant with the lowest inflection point. As a result, participants completed Tabove and Tbelow at rh 5.2 to 6.7% higher and 4.8 to 6.4% lower, respectively, than that corresponding to the esophageal temperature inflection point in the step protocol.
For the fixed-condition exposures, body temperatures and heart rate data were converted to min averages and smoothed using Friedman’s Super Smoother (56) using the “stats” package in base R.
In the fixed-condition exposures, participant nude body mass was measured to an accuracy of 10 g using a high-performance digital weighing terminal (model CBU150X, Mettler Toledo Inc) throughout the protocol (i.e., hours 0 [nude and instrumented], 2, 4, 6 [instrumented], and 9 or end-exposure [instrumented and nude]). Sweat rate was estimated as the change in body mass between hours 4 and 6, adjusted for fluid consumption and, if applicable, urination. Net fluid losses through sweat and urine were quantified as the change in nude body mass and presented as a percentage change from baseline values (corrected for consumed food).
Statistical Analyses.
Statistical analyses were conducted using R statistical software (Version 4.3.2). Data visualizations were created with “ggplot2” (57).
Autoregressive integrated moving average (ARIMA) analysis via the R package “fable” (58) was used to estimate the rate of change in rectal temperature, mean skin temperature, and heart rate at end-exposure (Fig. 2). End exposure for each participant was taken at trial termination (i.e., due to rectal temperature exceeding 39.2 °C, the participant experiencing adverse heat-related symptoms and/or requesting to withdraw, or 9 h elapsing). The hourly rate of change in these variables was then compared between conditions using linear mixed effects models fit via the “lme4” package (59) with a fixed effect for condition and a random intercept for participant id to account for the crossover design. Similar models were used to compare rectal temperatures, mean skin temperature, and heart rates at hour 9, and sweat rates between hours 4 and 6. For participants terminating before hour 9, data were projected out to 9 h from the point of termination using the ARIMA-estimated end-exposure change rate. Homoskedasticity and normality of residuals (fixed and random effects) were evaluated via visual inspection of diagnostic plots (60). A two-sided P < 0.050 was considered statistically significant. Between-condition comparisons were evaluated with the “marginaleffects” package (61) and presented as means and 95% CI.
The Kaplan–Meier curves (Fig. 2C) were produced using the R packages “survival” (62) and “survminer” (63). A log-rank test was used to compare the curves. For the bootstrap analysis (Fig. 2D), a sample size of 12 participants was drawn with replacement from the original dataset. The projected increase in rectal temperature was determined as described above and used to calculate the time it would take core temperature to rise from the group mean at hour 4 to 40.2 °C, an approximate threshold for heat stroke (15, 37). The projected time from the 4-h point was chosen since rectal temperature undergoes a rapid increase from the start of exposure and then a more gradual increase thereafter; the early transient period lasts ~4 to 6 h (34, 46). To account for this period, 3 h were added to the projected rectal time (effectively removing the equilibrium period). This process was repeated 5,000 times to derive the distributions of bootstrap estimates.
Rectal temperature was analyzed in place of esophageal temperature as the primary outcome since only 7 participants passed the 6 h point at which the esophageal temperature probe was inserted in Tabove and, of these participants, only 5 remained exposed for long enough for the rate of change in esophageal temperature to stabilize (e.g., after artifacts from water consumption during probe insertion). A Bland–Altman analysis (accounting for the nested data structure) using the “SimplyAgree” package (53) revealed good overall agreement between the esophageal and rectal temperature rate of change (Fig. 5).
Fig. 5.
Agreement between end-exposure rate of change in rectal temperature and esophageal temperature during the above (Tabove) and below (Tbelow) wet bulb limit conditions and control. The overall mean bias (dotted horizontal line) and upper and lower limits of agreement (upper and lower dashed lines) are also shown. LOA, limit of agreement.
Acknowledgments
This study was supported by the Natural Sciences and Engineering Research Council of Canada (NSERC; RGPIN-2020-03891, held by G.P.K.), Mitacs (IT27812 and IT30924, held by GPK) and the Human and Environmental Physiology Research Unit (provided by GPK). We thank Drs. Sean Notley, Nathalie Kirby, Aaron Bach, and Aaron Caldwell for their valuable input on trial design and interpretation. Our acknowledgement does not imply their endorsement.
Author contributions
R.D.M. developed the research question; R.D.M., F.K.O., and G.P.K. designed research; R.D.M., F.K.O., B.J.R., E.J.T., K.E.W., R.C.H.-M., T.E., and J.J.M. performed research; R.D.M., F.K.O., B.J.R., and E.J.T. analyzed data; F.K.O., B.J.R., E.J.T., K.E.W., R.C.H.-M., T.E., J.J.M., and G.P.K. revised manuscript for important intellectual content; R.D.M. wrote the paper; and G.P.K. provided administrative support.
Competing interests
The authors declare no competing interest.
Footnotes
This article is a PNAS Direct Submission.
Data, Materials, and Software Availability
Anonymized .csv file data are available at: https://github.com/robdmeade/uoramp (64).
References
- 1.Sherwood S. C., Ramsay E. E., Closer limits to human tolerance of global heat. Proc. Natl. Acad. Sci. U.S.A. 120, e2316003120 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Vecellio D. J., Kong Q., Kenney W. L., Huber M., Greatly enhanced risk to humans as a consequence of empirically determined lower moist heat stress tolerance. Proc. Natl. Acad. Sci. U.S.A. 120, e2305427120 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Powis C. M., et al. , Observational and model evidence together support wide-spread exposure to noncompensable heat under continued global warming. Sci. Adv. 9, eadg9297 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Vanos J., et al. , A physiological approach for assessing human survivability and liveability to heat in a changing climate. Nat. Commun. 14, 7653 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Guzman-Echavarria G., Middel A., Vecellio D. J., Vanos J., The development of an adaptive heat stress compensability classification applied to the United States. Int. J. Biometeorol., 10.1007/s00484-024-02766-7 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Fan Y., McColl K. A., Widespread outdoor exposure to uncompensable heat stress with warming. Commun. Earth Environ. 5, 1–13 (2024). [Google Scholar]
- 7.Meade R. D., et al. , Human heat resilience in a warming climate: Biophysical and physiological underpinnings of heat vulnerability and personal cooling strategies. One Earth 7, 1343–1350 (2024). [Google Scholar]
- 8.Kenny G. P., Jay O., Thermometry, calorimetry, and mean body temperature during heat stress. Compr. Physiol. 3, 1689–1719 (2013). [DOI] [PubMed] [Google Scholar]
- 9.Sherwood S. C., Huber M., An adaptability limit to climate change due to heat stress. Proc. Natl. Acad. Sci. U.S.A. 107, 9552–9555 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Pal J. S., Eltahir E. A., Future temperature in southwest Asia projected to exceed a threshold for human adaptability. Nat. Clim. Change 6, 197–200 (2016). [Google Scholar]
- 11.Henson B., “Heat and humidity near the survivability threshold: It’s already happening”. Weather Underground (2020). https://www.wunderground.com/cat6/heat-and-humidity-near-the-survivability-threshold-its-already-happening. Accessed 2 October 2024.
- 12.NASA Science Editorial Team, Too Hot to Handle: How Climate Change May Make Some Places Too Hot to Live (National Aeronautics and Space Administration NASA, 2022). [Google Scholar]
- 13.Economist The, The increasing frequency of fatal wet-bulb temperatures: Unbearable levels of heat and humidity pose an ever greater problem. The Economist (2022). https://www.economist.com/the-economist-explains/2022/05/13/the-increasing-frequency-of-fatal-wet-bulb-temperatures. Accessed 2 October 2024.
- 14.Wolf S. T., Cottle R. M., Vecellio D. J., Kenney W. L., Critical environmental limits for young, healthy adults (PSU HEAT Project). J. Appl. Physiol. 132, 327–333 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Cottle R. M., Lichter Z. S., Vecellio D. J., Wolf S. T., Kenney W. L., Core temperature responses to compensable versus uncompensable heat stress in young adults (PSU HEAT Project). J. Appl. Physiol. 133, 1011–1018 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Wolf S. T., Cottle R. M., Fisher K. G., Vecellio D. J., Kenney W. L., Heat stress vulnerability and critical environmental limits for older adults. Commun. Earth Environ. 4, 486 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Daanen H. A. M., et al. , Sex differences in thermophysiological responses of elderly to low-intensity exercise during uncompensable heat strain. Eur. J. Appl. Physiol. 124, 2451–2459 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Cottle R. M., Fisher K. G., Leach O. K., Wolf S. T., Kenney W. L., Critical environmental core temperature limits and heart rate thresholds across the adult age span (PSU HEAT Project). J. Appl. Physiol. 137, 145–153 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Wolf S. T., Havenith G., Kenney W. L., Relatively minor influence of individual characteristics on critical wet-bulb globe temperature (WBGT) limits during light activity in young adults (PSU HEAT Project). J. Appl. Physiol. 134, 1216–1223 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Wolf S. T., Folkerts M. A., Cottle R. M., Daanen H. A. M., Kenney W. L., Metabolism- and sex-dependent critical WBGT limits at rest and during exercise in the heat. Am. J. Physiol. Regul. Integr. Comp. Physiol. 321, R295–R302 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Leach O. K., Cottle R. M., Fisher K. G., Wolf S. T., Kenney W. L., Sex differences in heat stress vulnerability among middle-aged and older adults (PSU HEAT Project). Am. J. Physiol. Regul. Integr. Comp. Physiol. 327, R320–R327 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Bernard T. E., Ashley C. D., Wolf S. T., Kenney W. L., Core temperature and heart rate at the upper limit of the prescriptive zone. Physiol. Rep. 11, e15812 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Gagnon D., et al. , Age modulates physiological responses during fan use under extreme heat and humidity. Med. Sci. Sports Exerc. 49, 2333–2342 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Ravanelli N. M., Hodder S. G., Havenith G., Jay O., Heart rate and body temperature responses to extreme heat and humidity with and without electric fans. JAMA 313, 724–725 (2015). [DOI] [PubMed] [Google Scholar]
- 25.Ravanelli N., Coombs G. B., Imbeault P., Jay O., Maximum skin wettedness after aerobic training with and without heat acclimation. Med. Sci. Sports Exerc. 50, 299–307 (2018). [DOI] [PubMed] [Google Scholar]
- 26.Fisher K. G., Cottle R. M., Kenney W. L., Wolf S. T., Sunscreen does not alter sweating responses or critical environmental limits in young adults (PSU HEAT project). J. Appl. Physiol. 136, 322–329 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Bach A. J., Borg D. N., Minett G. M., Maley M. J., Stewart I. B., Biophysical, psychrometric and physiological limits for continuous liquid and air-based personal cooling systems in working men: A case for amending ASTM2300-10 (2016). Saf. Sci. 132, 104980 (2020). [Google Scholar]
- 28.Bernard T. E., et al. , Distribution of upper limit of the prescriptive zone values for acclimatized and unacclimatized individuals. J. Appl. Physiol. 135, 601–608 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Belding H. S., Kamon E., Evaporative coefficients for prediction of safe limits in prolonged exposures to work under hot conditions. Fed. Proc. 32, 1598–1601 (1973). [PubMed] [Google Scholar]
- 30.Lind A. R., A physiological criterion for setting thermal environmental limits for everyday work. J. Appl. Physiol. 18, 51–56 (1963). [DOI] [PubMed] [Google Scholar]
- 31.Wolf S. T., Vecellio D. J., Kenney W. L., Adverse heat-health outcomes and critical environmental limits (Pennsylvania State University Human Environmental Age Thresholds project). Am. J. Hum. Biol. 35, e23801 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Mitchell D., et al. , Revisiting concepts of thermal physiology: Predicting responses of mammals to climate change. J. Anim. Ecol. 87, 956–973 (2018). [DOI] [PubMed] [Google Scholar]
- 33.Meade R. D., et al. , Effects of daylong exposure to indoor overheating on thermal and cardiovascular strain in older adults: A randomized crossover trial. Environ. Health Perspect. 132, 27003 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Meade R. D., Notley S. R., Kenny G. P., Time to reach equilibrium deep body temperatures in young and older adults resting in the heat: A descriptive secondary analysis. Am. J. Physiol. Regul. Integr. Comp. Physiol. 327, R369–R377 (2024). [DOI] [PubMed] [Google Scholar]
- 35.Du Bois D., A formula to estimate the approximate surface area if height and weight be known. Nutrition 5, 303–313 (1989). [PubMed] [Google Scholar]
- 36.Canadian Society for Exercise Physiology, CSEP-PATH (Canadian Society for Exercise Physiology Ontario, Canada, 2013). [Google Scholar]
- 37.Meade R. D., et al. , Physiological factors characterizing heat-vulnerable older adults: A narrative review. Environ. Int. 144, 105909 (2020). [DOI] [PubMed] [Google Scholar]
- 38.Kenefick R. W., Cheuvront S. N., Physiological adjustments to hypohydration: Impact on thermoregulation. Auton. Neurosci. 196, 47–51 (2016). [DOI] [PubMed] [Google Scholar]
- 39.Meade R. D., Notley S. R., Kirby N. V., Kenny G. P., A critical review of the effectiveness of electric fans as a personal cooling intervention in hot weather and heatwaves. Lancet Planet Health 8, e256–e269 (2024). [DOI] [PubMed] [Google Scholar]
- 40.Taylor N. A., Tipton M. J., Kenny G. P., Considerations for the measurement of core, skin and mean body temperatures. J. Therm. Biol. 46, 72–101 (2014). [DOI] [PubMed] [Google Scholar]
- 41.Notley S. R., Mitchell D., Taylor N. A. S., A century of exercise physiology: Concepts that ignited the study of human thermoregulation. Part 2: Physiological measurements. Eur. J. Appl. Physiol. 123, 2587–2685 (2023). [DOI] [PubMed] [Google Scholar]
- 42.Loughnan M. E., Nicholls N., Tapper N. J., When the heat is on: Threshold temperatures for AMI admissions to hospital in Melbourne Australia. Appl. Geogr. 30, 63–69 (2010). [Google Scholar]
- 43.Gasparrini A., et al. , Mortality risk attributable to high and low ambient temperature: A multicountry observational study. Lancet 386, 369–375 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Bouchama A., et al. , Classic and exertional heatstroke. Nat. Rev. Dis. Primers 8, 8 (2022). [DOI] [PubMed] [Google Scholar]
- 45.Cottle R. M., Wolf S. T., Lichter Z. S., Kenney W. L., Validity and reliability of a protocol to establish human critical environmental limits (PSU HEAT Project). J. Appl. Physiol. 132, 334–339 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Meade R. D., et al. , Physiological responses to 9 hours of heat exposure in young and older adults. Part I: Body temperature and hemodynamic regulation. J. Appl. Physiol. 135, 673–687 (2023). [DOI] [PubMed] [Google Scholar]
- 47.Lakens D., Caldwell A. R., Simulation-based power analysis for factorial analysis of variance designs. Adv. Meth. Pract. Psychol. Sci. 4, 2515245920951503 (2021). [Google Scholar]
- 48.Kenefick R. W., Cheuvront S. N., Hydration for recreational sport and physical activity. Nutr. Rev. 70 (suppl. 2), S137–S142 (2012). [DOI] [PubMed] [Google Scholar]
- 49.Kingma B. R., Frijns A. J., Schellen L., van Marken Lichtenbelt W. D., Beyond the classic thermoneutral zone. Temperature (Austin) 1, 142–149 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Liu W., Lian Z., Deng Q., Use of mean skin temperature in evaluation of individual thermal comfort for a person in a sleeping posture under steady thermal environment. Indoor Built Environ. 24, 489–499 (2015). [Google Scholar]
- 51.Gagge A. P., Stolwijk J. A., Hardy J. D., Comfort and thermal sensations and associated physiological responses at various ambient temperatures. Environ. Res. 1, 1–20 (1967). [DOI] [PubMed] [Google Scholar]
- 52.Ramanathan N. L., A new weighting system for mean surface temperature of the human body. J. Appl. Physiol. 19, 531–533 (1964). [DOI] [PubMed] [Google Scholar]
- 53.Caldwell A. R., SimplyAgree: An R package and jamovi module for simplifying agreement and reliability analyses. J. Open Source Softw. 7, 4148 (2022). [Google Scholar]
- 54.Matheson G. J., We need to talk about reliability: Making better use of test-retest studies for study design and interpretation. PeerJ 7, e6918 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Nunnally J. C., Psychometric Theory (McGraw-Hill Book Company, New York, 1978). [Google Scholar]
- 56.Friedman J., A Variable Span Smoother (SLAC National Accelerator Lab, Menlo Park, CA, 1984). [Google Scholar]
- 57.Wickham H., ggplot2. Wiley Int. Rev.: Comput. Stat. 3, 180–185 (2011). [Google Scholar]
- 58.O’Hara-Wild M., Hyndman R., Wang E., fable: Forecasting Models for Tidy Time Series (R package version 0.3.3, 2023). https://cran.r-project.org/web/packages/fable/fable.pdf. Accessed 15 November 2023.
- 59.Bates D., Mächler M., Bolker B., Walker S., Fitting linear mixed-effects models using lme4. J. Stat. Softw. 67, 1–48 (2015). [Google Scholar]
- 60.Lüdecke D., Ben-Shachar M. S., Patil I., Waggoner P., Makowski D., performance: An R package for assessment, comparison and testing of statistical models. J. Open Source Softw. 6, 3139 (2021). [Google Scholar]
- 61.Arel-Bundock V., marginaleffects: Predictions, Comparisons, Slopes, Marginal Means, and Hypothesis Tests (R package version 0.16.0, 2023). https://cran.r-project.org/web/packages/marginaleffects/marginaleffects.pdf. Accessed 15 November 2023.
- 62.Collett D., Modelling Survival Data in Medical Research (Chapman and Hall/CRC, 2023). [Google Scholar]
- 63.Kassambara A., Kosinski M., Biecek P., survminer: Drawing Survival Curves Using “ggplot2” (R package version 0.4.9, 2023). https://cran.r-project.org/web/packages/survminer/survminer.pdf. Accessed 15 November 2023.
- 64.Meade R. D., uoramp. GitHub. https://github.com/robdmeade/uoramp. Deposited 12 March 2025.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Anonymized .csv file data are available at: https://github.com/robdmeade/uoramp (64).